CS Paper Radar

CHILD: Human-in-the-Loop OOD Detection for Safe Clinical Deployment

Jinlun Ye, Kaiyue Lu, Runhe Lai, Xinhua Lu, Jia-Xin Zhuang, Ruixuan Wang

cs.CV ·submitted 2026-09-07 08:16 UTC · v1
top venuecode/data

Abstract

Out-of-distribution (OOD) detection is critical for safe deployment of medical AI systems. Recently, test-time adaptation (TTA) has emerged as a new paradigm for OOD detection, automatically adjusting detector behavior during deployment. However, such automatic adaptation mechanisms may raise safety concerns in safety-critical clinical environments. While physician oversight can mitigate these risks, it is resource-intensive and must be judiciously allocated. To reconcile safety with efficiency, we propose CHILD, a training-free framework designed to enhance streaming OOD detection via sparse human feedback. Operating under strict budget constraints, CHILD employs an adaptive risk-aware sample selection mechanism to pinpoint only the most decision-uncertain samples for review. Crucially, it maximizes the utility of this sparse feedback through a retrieval-based score calibration module, which refines model predictions using a compact feature cache without any parameter updates. Extensive experiments on four medical benchmarks demonstrate that CHILD turns limited supervision into significant reliability gains: with a sparse feedback budget of only 5%, it reduces the average FPR95 from 72.63% to 60.26% and improves AUROC from 75.53% to 81.85%, consistently outperforming state-of-the-art baselines. Our code is publicly available at https://github.com/figec/CHILD.

Comment
11 pages. Accepted at MICCAI 2026

Closest papers

Nearest neighbours by meaning across the whole index.

ActiveMedAgent: Cost-Aware Trajectory Learning for Multimodal Medical Diagnosis

cs.LG cs.AIcs.CLcs.CV+1 ·2026-10-08 ·Weiwei Ma, Xiaobing Yu, Peijie Qiu, Jin Yang, Zhaoqi An +3 more
top venue similarity 0.64
Abstract · EMNLP 2026

Clinical diagnosis is inherently sequential: clinicians escalate from cheap to costly tests only when additional evidence is expected to resolve diagnostic uncertainty. We present ActiveMedAgent, a framework that brings this cost-aware sequential logic to multimodal medical AI. Given a frozen, API-accessed vision-language model, ActiveMedAgent tracks probability distributions over candidate diagnoses and scores each acquisition by its per-step diagnostic utility minus cost. A lightweight MLP controller is then trained offline on these scored trajectories, learning when to request additional evidence and when to commit. Across three commonly used benchmarks, trajectory-based policy learning consistently outperforms both unguided acquisition and full-modality baselines. Notably, we identify an information overload effect. In 175 cases, the agent produces a correct diagnosis with fewer channels while the full-modality baseline fails, showing that learning what to omit can be as important as learning what to acquire.

0.37

AutoAdapt: Reliable Few-Shot Adaptation under Clinical Distribution Shifts

cs.CV ·2026-10-08 ·Song Wang, Jie Peng, Davis Hobley, Zachary Plotkin, Tianlong Chen
similarity 0.63
Abstract

Large pretrained clinical models provide a practical way to reuse learned prior knowledge across hospitals by adapting models to them. In practice, a target hospital may only have a small labeled patient cohort, a setting commonly referred to as few-shot adaptation. This requires making multiple decisions, such as which pretrained model to adapt, how much of the model to update, and which patients to use. Nevertheless, this process faces two primary challenges. First, the best adaptation strategy varies across clinical tasks. Second, evaluating and comparing candidate strategies becomes unreliable due to the small patient cohort. In this work, we introduce AutoAdapt with two core designs to deal with these challenges. The Adapter defines an extensible space of adaptation recipes, and the Automator forms a weighted recipe combination from evidence within the adaptation patients. We propose a reliability rule to ensure that only the most effective strategy on most available patients will be selected. These selected strategies then form a combination for effective few-shot adaptation. We conduct extensive experiments across critical care, emergency care, and diagnostic datasets, and the results show that AutoAdapt consistently achieves state-of-the-art performance using only a few patients for adaptation.

0.18

Operation-aware Multimodal Clinical Decision Support System for ICU Discharge Risk Assessment

cs.LG ·2026-11-09 ·Guoqing Zhang, Rafik Hadfi, Takayuki Ito
benchmarkcode/data similarity 0.62
Abstract · 14 pages, 2 figures. Code available at https://github.com/KuoChing-cmd/ClinicalNoteAgent/

Unplanned 30-day intensive care unit (ICU) readmission is a critical benchmark for evaluating healthcare quality. Most predictive models assume readmission risk depends solely on a patient's individual pathophysiological state, ignoring hospital operational context and resource capacity. In practice, discharge decisions are dynamic trade-offs between patient stability and bed turnover pressures. To address this gap, we develop an Operation-aware Multimodal Clinical Decision Support System (CDSS) for ICU discharge risk assessment. The system combines multi-agent collaborative extraction with self-evolving retrieval-augmented generation (RAG) to eliminate template noise from progress notes, while constructing departmental workload indicators alongside admission flow features, continuous vital signs, and sparse medical codes (ICD/DRG). Addressing severe class imbalance (about 10.5% readmissions) and alarm fatigue, we implement data normalization, class reweighting, and decision-threshold calibration. In 20 independent runs across 20,000 ICU stays from MIMIC-III, empirical findings demonstrate that: vital signs alone have limited predictive capacity under real-world class imbalance (PR-AUC of 0.1387 +/- 0.0086); directly concatenating raw text embeddings degrades decision tree performance (XGBoost and LightGBM PR-AUC drop to 0.3893 and 0.4030); whereas an end-to-end multimodal fine-tuning architecture (Transformer E2E FineTune) utilizing layer-wise parameter freezing and differential learning rates reverses text negative transfer, achieving the highest AUROC of 0.8288 +/- 0.0110, PR-AUC of 0.4373 +/- 0.0310, and F1-Score of 0.4757 +/- 0.0196. Operational indicators supply independent risk signals, laying an engineering foundation for high-utility clinical decision support tools.

0.37

Less Is More in the Long Tail: Stage-Adaptive Sample Selection for Annotation-Efficient Dense Prediction

cs.CV ·2026-09-22 ·Xiaofei Du, Lei Zhang, Shuyu Yan, Manning Wang, Zhijian Song
similarity 0.61
Abstract

Deep learning performance generally improves with increasing training data, yet this scaling is fundamentally constrained by annotation cost in large-scale dense prediction tasks with long-tailed category distributions, where pixel- or voxel-level annotation is prohibitively expensive. We propose SASS (Stage-Adaptive Sample Selection), a stage-adaptive data-selection framework for pool-based active learning in long-tailed dense prediction. SASS combines three components: label-free self-supervised gradient scoring, prior-guided category rebalancing with validation-driven feedback, and stage-adaptive acquisition aligned with model training dynamics. This design avoids candidate ground-truth masks during gradient scoring while making acquisition responsive to long-tail imbalance and evolving representations. We evaluate SASS on a multimodal 3D medical segmentation testbed comprising over 100,000 samples spanning 108 anatomical structures. SASS recovers 98.3% of full-dataset performance with a 40% training-pool annotation budget, outperforming BADGE by 5.1 percentage points. Moreover, SASS exhibits a statistically supported less-is-more pattern, surpassing full-dataset training at the Hard-group level and, at the structure level, for the pancreas and gallbladder. More broadly, SASS shows that annotation-efficient learning depends not only on which samples are selected, but also on how the annotation budget is distributed across categories and when model-derived scores begin to guide selection.

0.18

RECAST: Recent & Context-Aware Sampling for Test-Time Adaptation in Streaming Biosignals

cs.AI ·2026-08-28 ·Yong-Yeon Jo, Junho Song, Joon-myoung Kwon
benchmark similarity 0.61
Abstract

Streaming biosignals vary across subjects and drift over time, so population-trained models lose accuracy during long-term monitoring. Test-time adaptation (TTA) enables online personalization by updating the model on incoming samples. But in a stream, a basic question is left open: \emph{which samples should drive each update?} Using all buffered samples blurs the update with irrelevant segments. Using only the latest segment makes the update noisy and unstable. The most useful samples are recent, aligned with the current physiological state, and reliable enough to learn from. We propose \textbf{RECAST} (REcent \& Context-Aware Sampling for TTA), a lightweight sampling module for buffered TTA frameworks. RECAST builds each adaptation batch from three signals: temporal recency, contextual similarity, and predictive reliability. It changes only which samples are used, leaving the model and the training objective unchanged. On two blood-pressure datasets, RECAST improves estimation accuracy and trend tracking over baselines and ablations. The per-patient gains are statistically significant on both datasets, with broad improvement on the regular benchmark and gains concentrated on the hardest patients in the emergency-department setting. RECAST stays practical, adding only sub-second latency per segment on a single GPU and CPU core.

0.18

Careful Judge: Safe and Efficient Human-AI Collaborative Decision Making

cs.AI stat.MLcs.LG ·2026-10-06 ·Chenyu Zhang, Rachel Luo, Boyi Li, Anjali Parashar, Marco Pavone +1 more
similarity 0.60
Abstract

In human-AI collaborative decision making, human review can prevent unsafe AI decisions, but each human judgment is costly. Treating human intervention after AI abstention as a one-off fallback misses the opportunity to improve future AI decisions for greater automation, yet AI adaptively learning from selectively queried human feedback breaks safety guardrails calibrated for old models. We approach this challenge with CARE---calibrated adaptive rectification and escalation---an end-to-end pipeline that combines AI models and human reviewers to guarantee safe, human-aligned decisions, while continuously learning from human feedback to achieve greater automation with fewer human queries. CARE is principled, general, modular, and works with any black-box AI model. Our novel adaptive calibration module guarantees risk control at every time step for any rectification module. We further show how CARE improves query efficiency when the AI model is well trained and the human-AI misalignment has a clear structure. Experiments on four safety-critical real-world datasets spanning driving, language, and robotics demonstrate that CARE achieves human-aligned decisions while reducing human queries by 25-81% relative to baselines.

0.23

CF-NODE: Counterfactual Spatial Node Intervention for Test-Time Adaptation Under Domain Shift, Evaluated Across Five Diabetic Retinopathy Datasets

cs.LG cs.CV ·2026-10-15 ·Sabarish G, Deepak Parashar
similarity 0.60
Abstract

Automated fundus-based diabetic retinopathy (DR) grading can substantially expand screening capacity, but source-trained models degrade sharply across different cameras, clinics, and patient populations. Existing test-time adaptation methods depend on entropy minimization or target information accumulated from image batches and streams. These mechanisms can reinforce confidently incorrect predictions and break down when clinical images arrive independently. We introduce CF-NODE, a novel counterfactual test-time adaptation framework for cross- domain DR grading. Instead of trusting prediction confidence or estimating a target distribution, CF-NODE asks how each prediction responds under a controlled intervention on the evidence supporting it. CF-NODE ranks internal spatial nodes using model-derived attention, feature magnitude, and node-set similarity, progressively attenuates the highest-ranked nodes, and uses the stability of the resulting expected-grade response to apply a bounded calibration of the predicted grade distribution. The framework is fully frozen and adapts every image independently using only geometric views and a fixed source-derived prior, requiring no target-derived information or model updates. We evaluate CF-NODE on five external DR datasets under repeated-seed evaluation against TENT, EATA, SAR, and T3A. CF-NODE outperforms all four methods with statistically significant improvements over the second-best method, improves AUC on every target domain, and attains the highest average AUC and macro-F1, delivering stronger grade discrimination together with more balanced recognition across DR severity levels. These results demonstrate that counterfactual intervention sensitivity provides consistent and deployment-ready domain robustness for single-image clinical inference.

0.21

Improving Calibration of Black-Box Radiology AI Using Test-Time Augmentation

cs.LG cs.HC ·2026-09-24 ·Nathan Le, Magdalini Paschali, Arogya Koirala, Andrew Johnston, Zhongnan Fang +3 more
publishedcode/data similarity 0.60
Abstract · 11 pages, 3 figures, 1 table. Accepted at the MICCAI 2026 Workshop on Uncertainty for Safe Utilization of Machine Learning in Medical Imagin…

Radiology AI systems increasingly inform clinical decisions such as triage, follow-up imaging, and treatment planning. For these decisions to be made safely, model outputs must be well calibrated, meaning predicted probabilities accurately reflect true risk. Many standard techniques for improving calibration, such as MC Dropout and Deep Ensembles, require access to model parameters or retraining. However, proprietary clinical AI systems operate as black boxes, preventing access to the model's internals. To that end, we propose a model-agnostic framework for improving calibration of black-box models using clinically grounded test-time augmentation (TTA). Our framework applies geometric and physics-inspired 3D CT perturbations and learns probability-level aggregation strategies without access to model internals or the original training data. Across pulmonary embolism and intracranial hemorrhage detection tasks, DualTTA achieved the strongest overall calibration among TTA methods, reducing the Expected Calibration Error by 54% (0.239 -> 0.109) and 43% (0.051 -> 0.029), respectively, while requiring only input-output access. Additionally, DualTTA outperformed uncertainty estimation techniques that require access to model internals, such as Temperature Scaling, MC Dropout, and Deep Ensembles, in most calibration metrics. These results demonstrate that learned TTA aggregation can improve the calibration of clinical AI systems, providing a practical approach for improving the reliability of black-box medical AI.

0.45