CS Paper Radar

RECAST: Recent & Context-Aware Sampling for Test-Time Adaptation in Streaming Biosignals

Yong-Yeon Jo, Junho Song, Joon-myoung Kwon

cs.AI ·submitted 2026-08-28 12:35 UTC · v1
benchmark

Abstract

Streaming biosignals vary across subjects and drift over time, so population-trained models lose accuracy during long-term monitoring. Test-time adaptation (TTA) enables online personalization by updating the model on incoming samples. But in a stream, a basic question is left open: \emph{which samples should drive each update?} Using all buffered samples blurs the update with irrelevant segments. Using only the latest segment makes the update noisy and unstable. The most useful samples are recent, aligned with the current physiological state, and reliable enough to learn from. We propose \textbf{RECAST} (REcent \& Context-Aware Sampling for TTA), a lightweight sampling module for buffered TTA frameworks. RECAST builds each adaptation batch from three signals: temporal recency, contextual similarity, and predictive reliability. It changes only which samples are used, leaving the model and the training objective unchanged. On two blood-pressure datasets, RECAST improves estimation accuracy and trend tracking over baselines and ablations. The per-patient gains are statistically significant on both datasets, with broad improvement on the regular benchmark and gains concentrated on the hardest patients in the emergency-department setting. RECAST stays practical, adding only sub-second latency per segment on a single GPU and CPU core.

Closest papers

Nearest neighbours by meaning across the whole index.

TSPFN: A Temporal Tabular Foundation Model for Physiological Time Series Classification

cs.LG cs.CV ·2026-08-31 ·Jérémie Stym-Popper, Clément Rambour, Federica Granese, Nicolas Thome, Olivier Bernard
publishedcode/data similarity 0.67
Abstract · Accepted at STACOM 2026 (MICCAI Workshop). 10 pages, 3 figures

Designing models that generalize effectively in low- to medium-data regimes remains a primary challenge in medical machine learning, particularly for physiological time-series classification. While tabular foundation models such as TabPFN offer an attractive alternative to conventional fine-tuning through in-context learning, they are not designed to capture the temporal dependencies inherent to physiological signals. ~In this paper, we introduce TSPFN, a foundation model that redesigns TabPFN's architecture for time series data. TSPFN integrates structured temporal representations and positional embeddings to capture intra-sample temporal and channel dependencies. To fully leverage its spatio-temporal design, the model is pretrained on 140,000 real-world physiological time series across multiple medical domains. This yields a unified, generalizable framework capable of learning the specificities of medical time series. Experiments across diverse physiological benchmarks demonstrate that TSPFN consistently outperforms standard tabular baselines and TabPFN, and achieves superior cross-domain generalization compared to specialized deep time-series models. All our experiments, ablation studies, and pre-processing scheme are publicly available at https://github.com/Jeremstym/TSPFN

0.48

Test-Time Adaptation for ECG Classification via SQI-Gated Self-Training and Beat-Rhythm Consistency

cs.LG ·2026-08-24 ·Wenhan Jiang, Zhipeng Deng, Jiale Zhou, Haolin Wang, Yafei Ou +1 more
top venue similarity 0.65
Abstract · Accepted at MICCAI 2026

Deep learning models for electrocardiogram (ECG) classification often suffer from significant performance degradation when deployed in unseen domains due to shifts in acquisition devices and patient populations. Test-time adaptation (TTA) offers a practical solution by adapting models using only unlabeled data at inference time. However, existing TTA methods often underperform on ECG tasks, since naive online updates ignore the hierarchical beat-rhythm structure of cardiac cycles and are vulnerable to signal artifacts, which leads to unstable adaptation and model drift. We propose BeatRhythm-TTA, an ECG-tailored TTA framework that explicitly accounts for ECG's noisy observations and structured beat-rhythm semantics under domain shift. First, to handle pervasive ECG artifacts, we introduce a Signal Quality Index (SQI)-gated adaptation scheme that selectively filters out low-quality signals to prevent harmful updates. Second, to leverage ECG's beat-rhythm semantics, we enforce dual-level consistency so the model preserves beat morphology and rhythm dynamics while adapting to shifted acquisition conditions. Extensive experiments on multi-label ECG diagnosis across three adaptation protocols, using PTB-XL as the source domain and CPSC2018/Georgia as two target domains, demonstrate the effectiveness of our method, yielding an average +2.70% relative improvement in Macro-F1 over the best competing method.

0.55

PPG-Bench: A Unified Benchmark for PPG Foundation Models

cs.LG ·2026-10-09 ·Arvasu Kulkarni, Mahir Jain, Aditya Ray Mishra, Sandeep Singh, Siddharth Panwar
benchmarkcode/data similarity 0.63
Abstract

Photoplethysmography (PPG) is increasingly recorded by wearable and clinical devices at enormous scale, and a growing number of PPG foundation models (FMs) have been developed to compute reusable representations for various downstream tasks. These models are difficult to compare: different evaluations use different datasets, task definitions, preprocessing, downstream heads, hyperparameter tuning, and baselines. We present PPG-Bench, a unifying open-source benchmark evaluating five public PPG FMs across nine open-access datasets and 26 tasks spanning cardiovascular state estimation, activity, sleep, screening, and identification. We evaluate models under four downstream regimes of increasing adaptability (linear probing, random forests, frozen MLP probes, and end-to-end finetuning), with model-specific hyperparameter optimization and subject-disjoint cross-validation. We also evaluate against three controls: random/constant baseline, a deterministic pulse-rate-variability (PRV) feature set, and a generic time-series FM (MOMENT). Across all 68 task-regime combinations, 35.3% show no meaningful FM advantage over the random/constant baseline, and in 83.8% no PPG-specific FM outperforms both PRV and MOMENT. We also find that added downstream head capacity generally improves performance, but can cause significant degradation if the model is performing at chance/constant level. Current PPG FMs therefore cannot yet claim to provide generalised and transferrable representations of PPG signals, and future evaluation in this field should include checks against simple, non-learned controls. Code for the benchmark and instructions to evaluate more models can be found here - https://github.com/mannas-ai/ppg-bench.

0.31

Represent, Then Generate: Multimodal-Conditioned Time-Series Generation under Irregular Missingness

cs.LG ·2026-08-12 ·Haochen Zhang, Jiaheng Guo, Yu-Chao Huang, Nicholas Konz, Tianlong Chen
similarity 0.63
Abstract · 17 pages, 5 figures

Continuous physiological time series underpin modern clinical monitoring, yet many of the most informative signals are invasive, expensive, or simply unavailable for a given patient. Conditional generation offers a remedy: an absent signal can be synthesized from co-recorded signals and routine clinical variables. Existing generators, however, are built around a single conditioning modality and degrade when forced to handle the heterogeneous, irregularly missing mix of time-variant signals and static covariates seen in practice. We propose ReCoGen (Represent Conditions, then Generate), a two-stage framework that decouples multimodal condition representation from target generation. Stage I trains one masked autoencoder per modality, distilling each time-variant condition into a compact and missingness-tolerant token sequence. Stage II trains a flow-matching generator that fuses these tokens with static conditions to synthesize the target signal. Across three physiological benchmarks, including continuous glucose monitoring on AI-READI and arterial blood pressure generation on MIMIC-III and MIMIC-IV, ReCoGen attains the best downstream utility on all sixteen (dataset, task, metric) settings, surpassing six representative conditional generators; on thirteen of them its utility also reaches or exceeds the utility measured on the real signal, a reference we read as an approximate anchor rather than a ceiling. Ablations trace the gains to the conditioning path: learnable cross-attention over the frozen per-modality encoders, and a dual token-plus-AdaLN route for the static conditions. ReCoGen thus turns routinely collected signals into informative surrogates for invasive or unavailable ones, a step toward less invasive, lower-cost continuous clinical monitoring.

0.10

Sequence Composition in EHR Foundation Model Pretraining

cs.LG ·2026-10-12 ·Joshua Placidi, Inigo Stibbe, Alfred J. Balston, Marek Rei, A. Aldo Faisal
position similarity 0.63
Abstract · 26 pages, 11 figures, 10 tables

Autoregressive electronic health record (EHR) foundation models predict the next event token in patient trajectories: sequences of structured medical events. A typical pretraining strategy is to concatenate all trajectories into a global stream and sample token windows from it. This gives patients with longer sequences more training exposure and allows tokens to attend across patient boundaries. We argue that these choices create a misalignment between pretraining and downstream clinical tasks. To explore this, we investigate how the composition of pretraining sequences affects clinical prediction performance. Using the global-stream approach as a baseline, we propose alternative sequence composition methods that control how patient trajectories contribute to pretraining sequences. Across four MIMIC-IV v2.2 tasks, our best method improves macro AUROC, AUPRC, F1, and balanced accuracy, with relative gains of 9.3% in F1 and 2.7% in AUPRC under a fixed training recipe. We find that these gains generalize across four additional evaluation settings, including the INSPIRE and eICU-CRD datasets, with improvements in macro AUROC, AUPRC, and F1 score. Our results show that simply changing how EHR data are presented to the model during pretraining can improve downstream performance, without changing the model or collecting additional data.

0.18

TimeOmni-Live: Continuous & Live Time Series Understanding with Long-Term Memory

cs.LG ·2026-11-06 ·Tong Guan, Alexander Chemeris, Yiqing Guo, Warren Jin, Zhao Li +2 more
similarity 0.62
Abstract

Existing time series language models predominantly follow an offline, one-shot paradigm: they process fixed-length inputs independently and do not retain past states. This static approach fundamentally misaligns with the continuous nature of real-world streaming applications and fails to maintain the historical context necessary for cross-window reasoning. To bridge this gap, we introduce Continuous & Live Time Series Understanding (CL-TSU), a novel paradigm that shifts the focus toward maintaining a persistent, stateful understanding over open-ended data streams. To systematically evaluate this paradigm, we present LiveTS-Suite, the first comprehensive data suite tailored for CL-TSU, supporting data generation, model training, and systematic evaluation across 18 tasks spanning six core capabilities. It comprises over 5K streams totaling 2.2B timesteps, annotated with 15K specific response events. We further design an evaluation protocol that jointly assesses response timeliness, content accuracy, and computational efficiency. Building on this foundation, we propose TimeOmni-Live, the first live time series understanding model. It integrates a hybrid time series encoding for natively temporal input, a stream-persistent hybrid memory mechanism to effectively preserve exact historical evidence and long-term task states, and an elastic stream-inference synchronization strategy to reduce processing lag. Evaluations show that TimeOmni-Live establishes a strong baseline for CL-TSU, outperforming frontier LLMs (90.0 vs. 79.3 for Opus 5) with only 4B parameters and achieving 206$\times$ lower p95 latency than its backbone. Deployment on a Jetson edge device further shows its ability to support real-time continuous temporal understanding locally at the edge.

0.04

CoMedBench: A Multi-Source Benchmark of Synthetic Medical Data Fidelity and Downstream Utility

cs.LG ·2026-08-13 ·Akanta Das, Farhad Al-Amin Dipto, Mrinmoy Sarkar Anto, David Rehkopf, Ayin Vala +1 more
benchmark similarity 0.61
Abstract

Access to clinical data is essential for developing reliable healthcare machine learning systems, but direct use of electronic health records is constrained by privacy regulation, institutional review, data-use agreements, and the risk of re-identification. Synthetic data promises a practical alternative: it can preserve useful statistical and clinical structure while reducing exposure of sensitive patient records. Prior studies often evaluate a single generator, one dataset, or a narrow downstream task, making it difficult to know when synthetic data can support model development and when it fails to preserve task-critical signal. We introduce CoMedBench, a reproducible benchmark that evaluates a family of generators under a common clinical-validity framework and one shared training and evaluation engine, spanning static tabular and temporal downstream tasks on established critical-care datasets. In total the benchmark spans 37 dataset-task pairs across two modalities consists of 20 static tabular and 17 temporal ICU time-series-drawn from seven public data sources: three intensive-care databases (MIMIC-III, MIMIC-IV, and eICU) together with the UCI Machine Learning Repository, the CDC BRFSS diabetes cohort (2015), NHANES (1999-2014), and the pycox survival datasets (GBSG and METABRIC). The benchmark evaluates both statistical fidelity and task utility by comparing models trained and tested across real and synthetic data. In these settings, synthetic training data preserves most of the downstream signal: on tabular tasks the reference generator CoMed-CTGAN retains a mean AUROC utility (the synthetic-to-real performance ratio) of 90.6%, rising to 97.3% for the strongest generator, CoMed-TVAE. Temporal ICU tasks are harder and more generator-sensitive: CoMed-CTGAN retains 81.6% (AUROC) and only 64.0% under the imbalance-sensitive AUPRC, whereas CoMed-TVAE still retains ~95% (AUROC).

0.04

CHILD: Human-in-the-Loop OOD Detection for Safe Clinical Deployment

cs.CV ·2026-09-07 ·Jinlun Ye, Kaiyue Lu, Runhe Lai, Xinhua Lu, Jia-Xin Zhuang +1 more
top venuecode/data similarity 0.61
Abstract · 11 pages. Accepted at MICCAI 2026

Out-of-distribution (OOD) detection is critical for safe deployment of medical AI systems. Recently, test-time adaptation (TTA) has emerged as a new paradigm for OOD detection, automatically adjusting detector behavior during deployment. However, such automatic adaptation mechanisms may raise safety concerns in safety-critical clinical environments. While physician oversight can mitigate these risks, it is resource-intensive and must be judiciously allocated. To reconcile safety with efficiency, we propose CHILD, a training-free framework designed to enhance streaming OOD detection via sparse human feedback. Operating under strict budget constraints, CHILD employs an adaptive risk-aware sample selection mechanism to pinpoint only the most decision-uncertain samples for review. Crucially, it maximizes the utility of this sparse feedback through a retrieval-based score calibration module, which refines model predictions using a compact feature cache without any parameter updates. Extensive experiments on four medical benchmarks demonstrate that CHILD turns limited supervision into significant reliability gains: with a sparse feedback budget of only 5%, it reduces the average FPR95 from 72.63% to 60.26% and improves AUROC from 75.53% to 81.85%, consistently outperforming state-of-the-art baselines. Our code is publicly available at https://github.com/figec/CHILD.

0.66