CS Paper Radar

A4-MR: Abnormality Aware Anatomical Alignment for MR

Noel D'souza, Zhijian Yang, Nishank Singla, Pranay Doshi, Krisztian Koos, Fei Tan, Bruno Nunes, Laszlo Rusko, Bernadett Kolozsvari, Eszter Sabo, Emanuele Valeriano, Hugh Pemberton, Vikash Gupta, Seyed Iman Zare Estakhraji, Marc Lebel, Farzin Haddadpour, Taha Kass-Hout, Erhan Bas

cs.CV ·submitted 2026-10-09 06:10 UTC · v2

Abstract

Recent advances in large-scale foundation models have enabled strong generalization across a wide range of clinical and research tasks in magnetic resonance imaging (MRI). However, existing vision-language MRI models remain limited in anatomy-specific localization and pathology-aware representation, particularly in real-world settings. We introduce A4-MR, a 3D vision-language foundation model trained on approximately 50,000 MRI studies comprising 491,000 series, roughly half of which are paired with radiology reports. A4-MR is designed to: (1) learn anatomy localization through large-scale pretraining with noisy labels; (2) align image and text representations at the anatomical level; and (3) learn distinct representations of healthy and abnormal anatomy. Across a diverse set of downstream tasks, A4-MR outperforms existing foundation models, including a +1.7 AUROC improvement over MedSigLIP for abnormality detection. Using a frozen encoder, A4-MR also surpasses an end-to-end task-specific MedNeXt model for knee segmentation by +1.4 Dice and performs comparably to the best task-specific model for abdominal organ segmentation on AMOS, within 0.4 Dice. Finally, without anatomical prompts, A4-MR localizes 3D anatomy comparably to MedSAM2 provided with ground-truth bounding boxes. Together, these results demonstrate that anatomy-level multimodal alignment and abnormality-aware representation learning can enable a single MRI foundation model to support localization, segmentation, and pathology-related tasks.

Closest papers

Nearest neighbours by meaning across the whole index.

Knee3DVLM: Dual-Sequence Full-Volume Vision-Language Modeling for Comprehensive Knee MRI Assessment

cs.CV cs.AI ·2026-10-06 ·Maryam Baizhigitova, Andrew Seohwan Yu, Po-Hao Chen, Naveen Subhas, Sixu Chen +5 more
similarity 0.73
Abstract · 11 pages, 2 figures, 5 tables

Vision-language models (VLMs) are increasingly being applied to three-dimensional medical imaging, but their application to knee MRI remains limited, particularly for interpreting the complementary sequences used in clinical practice. We introduce Knee3DVLM, a sequence-aware VLM that uses full-volume DESS and fluid-sensitive TSE MRI to predict 57 anatomically resolved binary diagnostic targets derived from the MRI Osteoarthritis Knee Score (MOAKS) for structured reporting. We evaluated DESS-only, TSE-only, and paired DESS-TSE configurations using subject-disjoint Osteoarthritis Initiative partitions. In a held-out cohort of 1,074 examinations, the fused model achieved 72.98% average accuracy, 71.17% balanced accuracy, 78.96% mean ROC-AUC, and 78.74% macro ROC-AUC, the highest values among the three configurations. In a secondary multiclass analysis aligned with the released 3DReasonKnee cohort, Knee3DVLM was numerically higher than the strongest reported 3DReasonKnee configuration across five pathology categories. These findings support dual-sequence full-volume modeling for comprehensive knee MRI assessment.

0.23

KneePreM: Towards 3D Knee MRI Foundation Models via Large-Scale Unlabeled Pretraining and Label-Efficient Fine-Tuning

cs.CV ·2026-09-25 ·Xinxin Wang, Liam Hazan, Jing Li, Simona Rabinovici-Cohen, Xiaojuan Li +1 more
similarity 0.69
Abstract

Background: Large volumes of unlabeled knee MRI scans are available across repositories but remain insufficiently leveraged. We developed KneePreM, a knee-specific 3D self-supervised model, and evaluated transfer and label efficiency for classification and segmentation. Methods: A 3D U-Net masked autoencoder was pretrained on 19,011 unlabeled Osteoarthritis Initiative (OAI) MRI series from 4,791 participants. Downstream fine-tuning used full and reduced training sets for fastMRI+ two-label classification (1,172 examinations), Arthroscopic Partial Meniscectomy (APM) eight-target classification (1,716 examinations), SKM-TEA segmentation (155 examinations), and APM segmentation (25 examinations). Baselines were random initialization and SuPreM. Deployment workflow was implemented with a Model Context Protocol interface. Evaluation metrics included balanced accuracy, F1 score, ROC AUC, PR AUC, and Dice score. Statistical analysis used bootstrap confidence intervals and paired bootstrap tests for classification and Wilcoxon signed-rank tests for segmentation. Results: KneePreM achieved higher full-data macro ROC AUC than both baselines for fastMRI+ and APM (all p < .001). For fastMRI+ classification, KneePreM achieved a ROC AUC of 0.722 using 50% of the training data, exceeding both full-data baselines. In APM classification, KneePreM reached a ROC AUC of 0.740 with 70% of the data, matching the full-data random baseline and outperforming SuPreM. For SKM-TEA segmentation, its 70%-data Dice of 0.838 exceeded the full-data random baseline (0.835) and both same-budget comparators. In APM segmentation, its 75%-data Dice of 0.746 exceeded the full-data random baseline (0.731) and both same-budget comparators. Conclusion: KneePreM improves transfer performance and label efficiency across knee MRI classification and segmentation tasks, particularly when labeled training data are limited.

0.34

Mr3D-VL: A generalist vision language foundation model for Multiparametric 3D Magnetic Resonance Imaging

cs.CV cs.AI ·2026-08-13 ·Zhi Qiao, Xintong Wu, Yichu He, Feng Shi
similarity 0.69
Abstract

Multi-parametric magnetic resonance imaging (mpMRI) is a cornerstone for brain tumor diagnosis and treatment, yet current AI models face critical limitations: their lack of natural language interaction and interpretability impedes spatial information integration and cross-modal reasoning required clinically. Key challenges arise from significant physical meaning differences across modalities, spatial misalignment due to scan intervals, and the need for complex multi-feature interpretation in tasks like glioma grading. While visual-language models (VLMs) show promise in cross-modal understanding, existing methods focus mainly on 2D image modeling, neglecting direct perception of 3D volumetric space. Although 3D VLMs have been proposed for report generation and feature alignment in 3D CT imaging, mpMRI applications demand collaborative inference across multiple imaging modalities-a requirement unmet by current solutions. To address this, we introduce Mr3D-VL, a dedicated visual-language foundation model for multi-parametric 3D MRI. With 4 billion parameters, it employs an unsupervised pre-trained shared 3D encoder and 4D rotational positional embedding for dual modality-spatial integration. Its cross-modal projection layer uses a multi-resolution feature implantation strategy to enhance feature perception across resolutions. Experimental results show significant improvements over existing 4B/7B/30B domain-specific and general-purpose models in text generation tasks, achieving a BERTScore of 0.856 for report generation, with question-answering accuracy at 0.713 and multiple-choice accuracy at 0.912.

0.04

Continual pretraining Prostate MRI ViT Encoder for task alignment

cs.CV cs.LG ·2026-10-14 ·Bilal A. Sidiqi, Yipei Wang, Shaheer U. Saeed, Shiqi Huang, Daniel C. Alexander +1 more
published similarity 0.67
Abstract · ISBI Conference 2026

Building foundation models for MRI has emerged as a promising direction for advancing medical image analysis and improving accessibility of task specific models. Existing approaches primarily focus on effective pretraining strategies and evaluating their performance across diverse downstream tasks. While these methods show performance gains, limited attention has been given to understanding task alignment between pretraining and downstream objectives. Unlike language models, where the two stages are naturally aligned, such alignment is less evident in vision based applications. Motivated by this gap, we explore continual pretraining. Specifically, continually pretraining a pretrained ViT encoder using Low-Rank Adaptation (LoRA) on a prostate segmentation task to enhance task alignment and downstream performance. We further perform layer-wise representational analysis using Centered Kernel Alignment (CKA) to assess representational shifts and their correlation with task outcomes. Our experiments show improved performance in 3 of 6 downstream tasks and comparable results in the others. Our Feature analysis reveals that, for segmentation tasks, continually pretrained encoder features exhibit greater similarity to those of the finetuned encoder than the original pretrained encoder, correlating with observed performance gains.

0.55

Multimodal AI in Healthcare: Review of Vision-Language Foundation Models for Real-World Medical Applications

cs.CV ·2026-11-15 ·Taha Razzaq, Murtaza Taj, Asim Iqbal
published similarity 0.66
Abstract · 20 Pages, 3 figures, 3 Tables

The emergence of foundation models has marked a transformative shift in AI, enabling robust generalization across diverse downstream tasks through putative zero-shot learning. Large Language Models and Vision Language Models have demonstrated strong capabilities in tasks such as image interpretation, report generation, and question answering by effectively learning from multimodal data-images paired with associated text often with minimal supervision. In the healthcare domain, this ability to align visual and textual information reduces the reliance on extensive manual annotations, as models can leverage existing clinical reports and imaging data to learn meaningful representations. This integration holds promise for improving diagnostic support, treatment planning, and overall patient care, even in data constrained settings. In this review, we provide a definitive taxonomy of the medical VLM landscape, tracing the evolution from early Contrastive Alignment and Generative MLLMs to the cutting edge frontiers of Dense Pixel Grounding, Sparse Mixture-of-Experts (MoE), and Reasoning Incentivized (RL) architectures. We critically examine the "medical bottleneck" identifying the persistent challenges of data scarcity, the "hallucination" risks in generative diagnostics, the computational strain of 3D volumetric processing, and the lack of standardized, clinically grounded evaluation metrics.

0.45

SA-Profile: Automated Sulcus Angle Profiling from Super-Resolution MRI

cs.CV cs.AI ·2026-09-09 ·Michael Wehrli, Leo Widmer, Edwin Li, Noel Fiechter, Lorenzo Pettinari +3 more
publishedcode/data similarity 0.65
Abstract · Accepted at MICCAI endorsed Event MICAD 2026

Trochlear dysplasia (TD) is an abnormality of the femoral trochlea associated with anterior knee pain and patellar instability. The sulcus angle (SA) is used to assess trochlear morphology, but it is typically measured on a single axial MR slice with no clear guidance on which to select, making it sensitive to slice selection and landmark placement. We propose an automatic framework for continuous SA profiling from super-resolved MR volumes. Clinically acquired axial, coronal, and sagittal MR scans are combined using implicit neural representations to reconstruct a high-resolution volume. SA measurements are computed across the trochlear region using two landmark detection U-Net models. The approach was evaluated on the public fastMRI dataset and a small in-house cohort of patients with TD. Compared with conventional manual single-slice SA measurements, the proposed automated method yielded a mean absolute error of 11.6$^\circ$ while providing continuous characterization of trochlear morphology. Population-level analysis demonstrated distinct mean SA profiles between the public cohort and the in-house TD cohort, highlighting the potential of profile-based assessment to characterize TD. By reducing reliance on a single manually selected axial slice, the proposed framework extends conventional SA assessment to a continuous profile-based description of trochlear morphology without additional imaging, while remaining conceptually linked to current clinical assessment. Further validation is required. The code is available: https://github.com/wehrlimi/SA_Profile.

0.57

Report-Derived Labels, an Image Teacher and the Gap to Expert Labels in Knee MRI: An Analysis of One Entry to the RSNA 2026 Knee Abnormality Detection Challenge

eess.IV ·2026-10-28 ·Soheil Kooklan
benchmarkcode/data similarity 0.65
Abstract · 24 pages, 10 figures, 14 tables. Code: https://github.com/soheilkooklan/rsna-knee-report-labels

In the RSNA 2026 Knee Abnormality Detection challenge, 58 of 4,407 training studies have expert labels for 12 findings, and the rest have only a radiology report. We compare training targets built from a language-model reading of the reports and from a public image model against two references: the expert labels and the 39,248 study-finding cells that the reports state as present or absent. The report labels and the out-of-fold predictions of the image model reach similar agreement with the expert labels (macro AUC 0.892 and 0.896) but fail on different findings. The report is better for ligament tears and patellofemoral osteoarthritis, which it never calls present when the experts do not; the image model is better for effusion, Baker's cyst, contusion, and synovitis, where the reports call the finding absent, leave it out, or call it present more often than the experts. Their equal mixture reaches 0.927 (gain over the report labels 0.035, 95% interval 0.019 to 0.052), also after removing the studies whose knee side was handled inconsistently. We did not observe a model-level gain from this better target: a 2.5D ResNet50 trained on the report labels alone scored 0.877 on the private leaderboard, after the deadline, against 0.872 for the same model trained on the mixture, and the out-of-fold advantage of the mixture is confounded by a change of code and by possible leakage through the image model's folds. A scanner prevalence prior raised agreement with the reports but not with the experts, so a report-derived reference can reward reporting habits. A rank correction for co-occurring findings gave small out-of-fold gains and no visible leaderboard effect. Our entry, a forked public ensemble with that correction, was displayed at rank 582 of 6,299 on the private leaderboard (0.943, a score shared by 287 teams). All results are exploratory; none of the models is meant for clinical use.

0.41

Lumen: Parameter-Efficient Alignment of Pretrained Vision and Language Encoders for Zero-Shot Computational Pathology

cs.CV ·2026-09-15 ·Kiarash Tajbakhsh, Abdelrahman Faqieh, Michael Jopiti, Javier Garcia-Baroja, Philipp Zens +7 more
similarity 0.64
Abstract

Pathology vision-language models are commonly built by pretraining or fine-tuning large encoders on paired image-caption data. We asked whether a pathology vision-language model can instead be assembled by parameter-efficient alignment of frozen unimodal foundation models, leaving their pretrained representations untouched. Here we present Lumen, which aligns frozen Virchow2 and BioMedBERT backbones using rank-4 adapters and projection heads, training only 0.40% of the total parameters on the public QUILT-1M corpus. Across nine public zero-shot patch benchmarks, Lumen achieved the highest mean chance-corrected balanced accuracy, 0.546 versus 0.461 for the strongest baseline (paired difference 0.086, 95% CI 0.042-0.136). On lymph-node metastasis detection, Lumen reached an AUROC of 0.964 (95% CI 0.956-0.971) on 4,214 held-out internal slides and 0.955 (95% CI 0.942-0.966) on 2,368 slides across nine external cohorts and six organs. At the internally calibrated threshold, it outperformed all vision-language baselines, with a balanced accuracy of 0.909 (95% CI 0.896-0.923) internally and 0.915 (95% CI 0.902-0.929) externally. Lumen performed competitively across the evaluations, with the exception of cross-modal retrieval, where it ranked third behind CONCH and PathGen-L/14. Fully fine-tuning both encoders gave Lumen no consistent benefit over low-rank adaptation, although it improved retrieval. Aligning frozen unimodal foundation models therefore yields strong and transferable performance at patch and slide level while training only a small fraction of the parameters.

0.15