CS Paper Radar

SA-Profile: Automated Sulcus Angle Profiling from Super-Resolution MRI

Michael Wehrli, Leo Widmer, Edwin Li, Noel Fiechter, Lorenzo Pettinari, Sidaty El Hadramy, Carol C. Hasler, Philippe C. Cattin

cs.CV cs.AI ·submitted 2026-09-09 13:01 UTC · v1
publishedcode/data

Abstract

Trochlear dysplasia (TD) is an abnormality of the femoral trochlea associated with anterior knee pain and patellar instability. The sulcus angle (SA) is used to assess trochlear morphology, but it is typically measured on a single axial MR slice with no clear guidance on which to select, making it sensitive to slice selection and landmark placement. We propose an automatic framework for continuous SA profiling from super-resolved MR volumes. Clinically acquired axial, coronal, and sagittal MR scans are combined using implicit neural representations to reconstruct a high-resolution volume. SA measurements are computed across the trochlear region using two landmark detection U-Net models. The approach was evaluated on the public fastMRI dataset and a small in-house cohort of patients with TD. Compared with conventional manual single-slice SA measurements, the proposed automated method yielded a mean absolute error of 11.6$^\circ$ while providing continuous characterization of trochlear morphology. Population-level analysis demonstrated distinct mean SA profiles between the public cohort and the in-house TD cohort, highlighting the potential of profile-based assessment to characterize TD. By reducing reliance on a single manually selected axial slice, the proposed framework extends conventional SA assessment to a continuous profile-based description of trochlear morphology without additional imaging, while remaining conceptually linked to current clinical assessment. Further validation is required. The code is available: https://github.com/wehrlimi/SA_Profile.

Comment
Accepted at MICCAI endorsed Event MICAD 2026

Closest papers

Nearest neighbours by meaning across the whole index.

A4-MR: Abnormality Aware Anatomical Alignment for MR

cs.CV ·2026-10-09 ·Noel D'souza, Zhijian Yang, Nishank Singla, Pranay Doshi, Krisztian Koos +13 more
similarity 0.65
Abstract

Recent advances in large-scale foundation models have enabled strong generalization across a wide range of clinical and research tasks in magnetic resonance imaging (MRI). However, existing vision-language MRI models remain limited in anatomy-specific localization and pathology-aware representation, particularly in real-world settings. We introduce A4-MR, a 3D vision-language foundation model trained on approximately 50,000 MRI studies comprising 491,000 series, roughly half of which are paired with radiology reports. A4-MR is designed to: (1) learn anatomy localization through large-scale pretraining with noisy labels; (2) align image and text representations at the anatomical level; and (3) learn distinct representations of healthy and abnormal anatomy. Across a diverse set of downstream tasks, A4-MR outperforms existing foundation models, including a +1.7 AUROC improvement over MedSigLIP for abnormality detection. Using a frozen encoder, A4-MR also surpasses an end-to-end task-specific MedNeXt model for knee segmentation by +1.4 Dice and performs comparably to the best task-specific model for abdominal organ segmentation on AMOS, within 0.4 Dice. Finally, without anatomical prompts, A4-MR localizes 3D anatomy comparably to MedSAM2 provided with ground-truth bounding boxes. Together, these results demonstrate that anatomy-level multimodal alignment and abnormality-aware representation learning can enable a single MRI foundation model to support localization, segmentation, and pathology-related tasks.

0.12

Knee3DVLM: Dual-Sequence Full-Volume Vision-Language Modeling for Comprehensive Knee MRI Assessment

cs.CV cs.AI ·2026-10-06 ·Maryam Baizhigitova, Andrew Seohwan Yu, Po-Hao Chen, Naveen Subhas, Sixu Chen +5 more
similarity 0.63
Abstract · 11 pages, 2 figures, 5 tables

Vision-language models (VLMs) are increasingly being applied to three-dimensional medical imaging, but their application to knee MRI remains limited, particularly for interpreting the complementary sequences used in clinical practice. We introduce Knee3DVLM, a sequence-aware VLM that uses full-volume DESS and fluid-sensitive TSE MRI to predict 57 anatomically resolved binary diagnostic targets derived from the MRI Osteoarthritis Knee Score (MOAKS) for structured reporting. We evaluated DESS-only, TSE-only, and paired DESS-TSE configurations using subject-disjoint Osteoarthritis Initiative partitions. In a held-out cohort of 1,074 examinations, the fused model achieved 72.98% average accuracy, 71.17% balanced accuracy, 78.96% mean ROC-AUC, and 78.74% macro ROC-AUC, the highest values among the three configurations. In a secondary multiclass analysis aligned with the released 3DReasonKnee cohort, Knee3DVLM was numerically higher than the strongest reported 3DReasonKnee configuration across five pathology categories. These findings support dual-sequence full-volume modeling for comprehensive knee MRI assessment.

0.23

Reliability assessment and multicenter clinical application of magnetic resonance methods for knee cartilage quantification

eess.IV q-bio.QM ·2026-09-08 ·Binbin Yang, Yongmei Jian, Chenglei Liu, Rui Huang, Hongda Shao +8 more
similarity 0.62
Abstract · 57 pages, including supporting information and a graphical abstract; 5 main figures, 7 supplementary figures, 3 main tables, and 6 supplemen…

Background: This study evaluated interreader agreement and longitudinal performance of MRI methods for knee cartilage volume, thickness, and defect-area quantification. Methods: AI-presegmented masks from 1,189 phase III examinations underwent independent correction by two readers and adjudication. Cartilage volume, three-dimensional ray-tracing thickness (3D-RT), and ray-based defect area (3D-RBA), defined by a 1.5-mm thickness threshold, were calculated. Agreement was assessed using segmentation metrics, intraclass correlation coefficients (ICCs), repeated-measures Bland-Altman analysis, and minimal detectable change at 95% confidence (MDC95). The 3D-RBA framework was evaluated in 120 digital-phantom experiments from 40 participants. Longitudinal analyses included 374 participants, alternative-method comparisons included 65, and retrospective phase II analysis included 24 participants with four visits. Results: Overall AI-to-adjudicated-mask Dice was 0.964 +/- 0.029. Interreader ICCs for volume, thickness, and defect area were 0.956, 0.904, and 0.932; corresponding MDC95 values were 1,596.9 mm^3, 0.227 mm, and 147.4 mm^2. Geometric mean absolute percentage error for defect area was 5.62%, with spatial Dice of 0.961. In 374 participants, volume changes correlated positively with thickness changes (rho=0.431) and negatively with defect-area changes (rho=-0.221). Within-participant phase II correlations followed the same directions in both groups. Conclusions: The workflow demonstrated good interreader agreement. Controlled geometric results and longitudinal associations supported the feasibility of threshold-based defect-area estimation. Volume, thickness, and defect area provide complementary measures of cartilage structure.

0.37

KneePreM: Towards 3D Knee MRI Foundation Models via Large-Scale Unlabeled Pretraining and Label-Efficient Fine-Tuning

cs.CV ·2026-09-25 ·Xinxin Wang, Liam Hazan, Jing Li, Simona Rabinovici-Cohen, Xiaojuan Li +1 more
similarity 0.59
Abstract

Background: Large volumes of unlabeled knee MRI scans are available across repositories but remain insufficiently leveraged. We developed KneePreM, a knee-specific 3D self-supervised model, and evaluated transfer and label efficiency for classification and segmentation. Methods: A 3D U-Net masked autoencoder was pretrained on 19,011 unlabeled Osteoarthritis Initiative (OAI) MRI series from 4,791 participants. Downstream fine-tuning used full and reduced training sets for fastMRI+ two-label classification (1,172 examinations), Arthroscopic Partial Meniscectomy (APM) eight-target classification (1,716 examinations), SKM-TEA segmentation (155 examinations), and APM segmentation (25 examinations). Baselines were random initialization and SuPreM. Deployment workflow was implemented with a Model Context Protocol interface. Evaluation metrics included balanced accuracy, F1 score, ROC AUC, PR AUC, and Dice score. Statistical analysis used bootstrap confidence intervals and paired bootstrap tests for classification and Wilcoxon signed-rank tests for segmentation. Results: KneePreM achieved higher full-data macro ROC AUC than both baselines for fastMRI+ and APM (all p < .001). For fastMRI+ classification, KneePreM achieved a ROC AUC of 0.722 using 50% of the training data, exceeding both full-data baselines. In APM classification, KneePreM reached a ROC AUC of 0.740 with 70% of the data, matching the full-data random baseline and outperforming SuPreM. For SKM-TEA segmentation, its 70%-data Dice of 0.838 exceeded the full-data random baseline (0.835) and both same-budget comparators. In APM segmentation, its 75%-data Dice of 0.746 exceeded the full-data random baseline (0.731) and both same-budget comparators. Conclusion: KneePreM improves transfer performance and label efficiency across knee MRI classification and segmentation tasks, particularly when labeled training data are limited.

0.34

Report-Derived Labels, an Image Teacher and the Gap to Expert Labels in Knee MRI: An Analysis of One Entry to the RSNA 2026 Knee Abnormality Detection Challenge

eess.IV ·2026-10-28 ·Soheil Kooklan
benchmarkcode/data similarity 0.58
Abstract · 24 pages, 10 figures, 14 tables. Code: https://github.com/soheilkooklan/rsna-knee-report-labels

In the RSNA 2026 Knee Abnormality Detection challenge, 58 of 4,407 training studies have expert labels for 12 findings, and the rest have only a radiology report. We compare training targets built from a language-model reading of the reports and from a public image model against two references: the expert labels and the 39,248 study-finding cells that the reports state as present or absent. The report labels and the out-of-fold predictions of the image model reach similar agreement with the expert labels (macro AUC 0.892 and 0.896) but fail on different findings. The report is better for ligament tears and patellofemoral osteoarthritis, which it never calls present when the experts do not; the image model is better for effusion, Baker's cyst, contusion, and synovitis, where the reports call the finding absent, leave it out, or call it present more often than the experts. Their equal mixture reaches 0.927 (gain over the report labels 0.035, 95% interval 0.019 to 0.052), also after removing the studies whose knee side was handled inconsistently. We did not observe a model-level gain from this better target: a 2.5D ResNet50 trained on the report labels alone scored 0.877 on the private leaderboard, after the deadline, against 0.872 for the same model trained on the mixture, and the out-of-fold advantage of the mixture is confounded by a change of code and by possible leakage through the image model's folds. A scanner prevalence prior raised agreement with the reports but not with the experts, so a report-derived reference can reward reporting habits. A rank correction for co-occurring findings gave small out-of-fold gains and no visible leaderboard effect. Our entry, a forked public ensemble with that correction, was displayed at rank 582 of 6,299 on the private leaderboard (0.943, a score shared by 287 teams). All results are exploratory; none of the models is meant for clinical use.

0.41

Flexible Multi-Stack Super-Resolution of Clinical Brain MRI Using Hetero-Orientation Variational Encoding: Expert Reader Evaluation in a Nigerian Cohort

cs.CV ·2026-11-16 ·Kabir Hamzah Muhammad, Lorena Garcia-Foncillas Macias, Soumya Snigdha Kundu, Emily Guilhem, Jon Cleary +8 more
code/data similarity 0.58
Abstract · 27 pages, 14 figures

High-resolution brain MRI is important for neuroradiological assessment, yet routine clinical protocols often rely on fast, anisotropic 2D acquisitions, particularly in resource-constrained settings. These acquisitions may differ in orientation, alignment and anatomical coverage, resulting in partially overlapping image stacks. Existing learning-based super-resolution methods typically rely on single, under-constrained inputs or fixed multi-stack configurations with idealised acquisition geometry. We introduce MS-HVED, a sequence-agnostic framework for flexible multi-stack brain MRI super-resolution. Available axial, coronal and sagittal stacks are independently encoded into multi-scale Gaussian posteriors and fused using a field-of-view-aware Product-of-Gaussians formulation that limits contributions from unsupported regions. Physics-informed domain randomisation simulates heterogeneous clinical acquisition conditions, including obliqueness, partial coverage and imaging artefacts. MS-HVED achieved competitive or superior reconstruction fidelity across synthetic benchmarks and improved downstream tissue segmentation relative to low-resolution inputs. To assess generalisation beyond the training cohorts, we performed external clinical validation on 30 routine brain MRI examinations from a Nigerian cohort, representing an under-represented population in medical imaging research. These examinations formed the largest component of a blinded reader study involving 44 real cases and seven expert neuroradiologists. In the Nigerian cohort, MS-HVED was preferred over the supervised baseline for overall image quality in 187 of 210 paired assessments. Across all clinical cohorts, MS-HVED achieved higher overall-quality scores with all available inputs (5.93 vs. 4.49, p<.001), with the preference persisting when axial or coronal inputs were omitted (p<.001). Code at github.com/cai4cai/ms-hved

0.52

Targeted Deep Regression - Initial Applications in Whole-Body Water-Fat MRI in UK Biobank

cs.CV cs.LG ·2026-10-26 ·Filip Marttala, Taro Langner, Johan Öfverstedt, Nouman Ahmad, Håkan Ahlström +2 more
similarity 0.58
Abstract · 16 pages, 8 figures

UK Biobank is a British clinical study which, in addition to large amounts of medical data collected, plans to include detailed Magnetic Resonance Imaging (MRI) examina- tions from 100,000 participants. The image data can be analyzed for example by auto- mated analysis with neural networks for image segmentation or classification to expand the collection of image-derived phenotypes for medical research. In this work, we pro- pose, present and evaluate a methodology that uses image-based regression to estimate numerical properties from the collected neck-to-knee water-fat MRI scans. It applies a ResNet50-style network to 2D multi-channel collages that represent targeted and study- specific anatomical sub-regions from the MRI scan. The targeted sub-region sampling is achieved by propagating manually defined subregions from a reference scan to the other >30,000 analyzed scans using image registration. The resulting collages can be compact while retaining high-resolution, for example by providing multiple slices of kidney tissue for a kidney volume regression network. This approach also enables group-wise saliency analysis that highlight image and anatomical regions used by the network for the pre- dictions. The method was applied for the regression endpoints of kidney volume, heart volume, and age. Predictive performance was found between R2 = 0.731-0.984 and the group-wise saliency maps were found to highlight medically relevant regions. We con- clude that the method can be used to standardize and restrict the information presented to a deep regression analysis pipeline, increasing information density and opening up a wide range of future medical inference studies.

0.24

Automated ACL Footprint Identification Using 3D Deep Learning

cs.CV ·2026-08-18 ·Ruida Cheng, Gabriel Gibson, Ali Uneri, Frances T. Sheehan, Barry Boden
similarity 0.58
Abstract · 10 pages, 5 figures

One of the most common reasons for anterior cruciate ligament (ACL) reconstruction failure is femoral tunnel malpositioning (ACL footprint center and tunnel orientation). Such failures may lead to the development of meniscal pathology and osteoarthritis. Accurate ACL femoral footprint identification is therefore essential for precise tunnel placement, restoration of the native knee joint mechanics, post-surgical knee joint health and prevention of graft failure. Recent advances in artificial intelligence (AI) bring new opportunities to improve image-guided orthopedic surgery. However, at present, existing AI research focuses primarily on ACL segmentation and rupture classification based on pre- and post-operative magnetic resonance (MR) images. Identification of the ACL footprint center using deep learning methods has not been thoroughly researched. Thus, the purpose of this study is to explore 3D deep learning models for ACL femoral footprint identification directly from 3D MR images. Two comprehensive 3D deep learning architectures were developed: a 3D graph convolutional neural network-based geometric model applied to 3D femoral meshes; and a 3D landmark-enhanced identification model based on 3D MR images. A total of 4883 right and 3087 left knee image sets were used from a publicly available database. Eighty percent (80%) were applied to model generation, and twenty percent (20%) were preserved for model testing. Both models achieved excellent performance; however, the image-based method outperformed the model-based method (average error of 2.1mm vs 2.8 mm). Thus, 3D deep learning provides a feasible clinical approach for ACL footprint localization and has the potential to improve ACL reconstruction footprint accuracy.

0.38