CS Paper Radar

Reliability assessment and multicenter clinical application of magnetic resonance methods for knee cartilage quantification

Binbin Yang, Yongmei Jian, Chenglei Liu, Rui Huang, Hongda Shao, Linjun Tong, Yuanjing Xu, Jingshu Wu, Chengzhang He, Suting Peng, Ming Xiao, Yinan Chen, Qi Duan

eess.IV q-bio.QM ·submitted 2026-09-08 00:49 UTC · v2

Abstract

Background: This study evaluated interreader agreement and longitudinal performance of MRI methods for knee cartilage volume, thickness, and defect-area quantification. Methods: AI-presegmented masks from 1,189 phase III examinations underwent independent correction by two readers and adjudication. Cartilage volume, three-dimensional ray-tracing thickness (3D-RT), and ray-based defect area (3D-RBA), defined by a 1.5-mm thickness threshold, were calculated. Agreement was assessed using segmentation metrics, intraclass correlation coefficients (ICCs), repeated-measures Bland-Altman analysis, and minimal detectable change at 95% confidence (MDC95). The 3D-RBA framework was evaluated in 120 digital-phantom experiments from 40 participants. Longitudinal analyses included 374 participants, alternative-method comparisons included 65, and retrospective phase II analysis included 24 participants with four visits. Results: Overall AI-to-adjudicated-mask Dice was 0.964 +/- 0.029. Interreader ICCs for volume, thickness, and defect area were 0.956, 0.904, and 0.932; corresponding MDC95 values were 1,596.9 mm^3, 0.227 mm, and 147.4 mm^2. Geometric mean absolute percentage error for defect area was 5.62%, with spatial Dice of 0.961. In 374 participants, volume changes correlated positively with thickness changes (rho=0.431) and negatively with defect-area changes (rho=-0.221). Within-participant phase II correlations followed the same directions in both groups. Conclusions: The workflow demonstrated good interreader agreement. Controlled geometric results and longitudinal associations supported the feasibility of threshold-based defect-area estimation. Volume, thickness, and defect area provide complementary measures of cartilage structure.

Comment
57 pages, including supporting information and a graphical abstract; 5 main figures, 7 supplementary figures, 3 main tables, and 6 supplementary tables

Closest papers

Nearest neighbours by meaning across the whole index.

SA-Profile: Automated Sulcus Angle Profiling from Super-Resolution MRI

cs.CV cs.AI ·2026-09-09 ·Michael Wehrli, Leo Widmer, Edwin Li, Noel Fiechter, Lorenzo Pettinari +3 more
publishedcode/data similarity 0.62
Abstract · Accepted at MICCAI endorsed Event MICAD 2026

Trochlear dysplasia (TD) is an abnormality of the femoral trochlea associated with anterior knee pain and patellar instability. The sulcus angle (SA) is used to assess trochlear morphology, but it is typically measured on a single axial MR slice with no clear guidance on which to select, making it sensitive to slice selection and landmark placement. We propose an automatic framework for continuous SA profiling from super-resolved MR volumes. Clinically acquired axial, coronal, and sagittal MR scans are combined using implicit neural representations to reconstruct a high-resolution volume. SA measurements are computed across the trochlear region using two landmark detection U-Net models. The approach was evaluated on the public fastMRI dataset and a small in-house cohort of patients with TD. Compared with conventional manual single-slice SA measurements, the proposed automated method yielded a mean absolute error of 11.6$^\circ$ while providing continuous characterization of trochlear morphology. Population-level analysis demonstrated distinct mean SA profiles between the public cohort and the in-house TD cohort, highlighting the potential of profile-based assessment to characterize TD. By reducing reliance on a single manually selected axial slice, the proposed framework extends conventional SA assessment to a continuous profile-based description of trochlear morphology without additional imaging, while remaining conceptually linked to current clinical assessment. Further validation is required. The code is available: https://github.com/wehrlimi/SA_Profile.

0.57

Knee3DVLM: Dual-Sequence Full-Volume Vision-Language Modeling for Comprehensive Knee MRI Assessment

cs.CV cs.AI ·2026-10-06 ·Maryam Baizhigitova, Andrew Seohwan Yu, Po-Hao Chen, Naveen Subhas, Sixu Chen +5 more
similarity 0.61
Abstract · 11 pages, 2 figures, 5 tables

Vision-language models (VLMs) are increasingly being applied to three-dimensional medical imaging, but their application to knee MRI remains limited, particularly for interpreting the complementary sequences used in clinical practice. We introduce Knee3DVLM, a sequence-aware VLM that uses full-volume DESS and fluid-sensitive TSE MRI to predict 57 anatomically resolved binary diagnostic targets derived from the MRI Osteoarthritis Knee Score (MOAKS) for structured reporting. We evaluated DESS-only, TSE-only, and paired DESS-TSE configurations using subject-disjoint Osteoarthritis Initiative partitions. In a held-out cohort of 1,074 examinations, the fused model achieved 72.98% average accuracy, 71.17% balanced accuracy, 78.96% mean ROC-AUC, and 78.74% macro ROC-AUC, the highest values among the three configurations. In a secondary multiclass analysis aligned with the released 3DReasonKnee cohort, Knee3DVLM was numerically higher than the strongest reported 3DReasonKnee configuration across five pathology categories. These findings support dual-sequence full-volume modeling for comprehensive knee MRI assessment.

0.23

Report-Derived Labels, an Image Teacher and the Gap to Expert Labels in Knee MRI: An Analysis of One Entry to the RSNA 2026 Knee Abnormality Detection Challenge

eess.IV ·2026-10-28 ·Soheil Kooklan
benchmarkcode/data similarity 0.59
Abstract · 24 pages, 10 figures, 14 tables. Code: https://github.com/soheilkooklan/rsna-knee-report-labels

In the RSNA 2026 Knee Abnormality Detection challenge, 58 of 4,407 training studies have expert labels for 12 findings, and the rest have only a radiology report. We compare training targets built from a language-model reading of the reports and from a public image model against two references: the expert labels and the 39,248 study-finding cells that the reports state as present or absent. The report labels and the out-of-fold predictions of the image model reach similar agreement with the expert labels (macro AUC 0.892 and 0.896) but fail on different findings. The report is better for ligament tears and patellofemoral osteoarthritis, which it never calls present when the experts do not; the image model is better for effusion, Baker's cyst, contusion, and synovitis, where the reports call the finding absent, leave it out, or call it present more often than the experts. Their equal mixture reaches 0.927 (gain over the report labels 0.035, 95% interval 0.019 to 0.052), also after removing the studies whose knee side was handled inconsistently. We did not observe a model-level gain from this better target: a 2.5D ResNet50 trained on the report labels alone scored 0.877 on the private leaderboard, after the deadline, against 0.872 for the same model trained on the mixture, and the out-of-fold advantage of the mixture is confounded by a change of code and by possible leakage through the image model's folds. A scanner prevalence prior raised agreement with the reports but not with the experts, so a report-derived reference can reward reporting habits. A rank correction for co-occurring findings gave small out-of-fold gains and no visible leaderboard effect. Our entry, a forked public ensemble with that correction, was displayed at rank 582 of 6,299 on the private leaderboard (0.943, a score shared by 287 teams). All results are exploratory; none of the models is meant for clinical use.

0.41

3D Reconstruction from Arthroscopic Images using NeRF: a preliminary in-silico study

eess.IV ·2026-09-30 ·Hermine Kitio Tsamo, Agathe Yvinou, Daniel Pizarro, Samad Barri Khojasteh, Alexandre Tronchot +4 more
published similarity 0.58
Abstract

In knee arthroscopy surgery, accurate registration between preoperative and intraoperative anatomy is a critical step for patient-specific navigation. Achieving an accurate registration requires a reliable 3D reconstruction of the joint during surgery. Preoperative 3D models can be obtained from patient imaging through segmentation and reconstruction, but generating an intraoperative 3D representation remains particularly challenging. Arthroscopic imaging suffers from a limited field of view, low surface texture, and strong specular reflections, which make conventional feature-based 3D reconstruction methods unreliable. In this work, we investigate the application of MIS-NeRF (Minimally-Invasive Surgery Neural Radiance Fields) for reconstructing intraoperative knee 3D models from monocular arthroscopic images. The approach is evaluated on six simulated arthroscopic acquisitions representing six patient-specific knee 3D models. Both qualitative and quantitative results are presented to assess the reconstruction quality. The reconstructed knee 3D models were evaluated through their rendered images, achieving PSNR (Peak Signal-to-Noise Ratio) of 31.88 $\pm$ 2.82, SSIM (Structural Similarity Index) of 0.98 $\pm$ 0.004 and LPIPS (Learned Perceptual Image Patch Similarity) of 0.017 $\pm$ 0.006. These preliminary results suggest the feasibility of NeRF-based reconstruction in the challenging context of arthroscopy and may represent a promising step toward accurate in-silico preoperative-to-intraoperative 3D registration for computer-assisted orthopedic surgery. Further, validation on real arthroscopic data will be necessary to assess clinical applicability.

0.37

Multitask Conditional Generative Adversarial Network Enables Automatic Whole Knee Cartilage and Menisci Segmentation and Reliable $T_{1ρ}$ and $T_2$ Quantification Without High-Resolution Morphological Images

cs.CV eess.IV ·2026-10-05 ·Ahmed Tahseen Minhaz, Richard Lartey, Zhiyuan Zhang, Jeehun Kim, Kunio Nakamura +6 more
similarity 0.56
Abstract

Early osteoarthritis detection through quantitative MRI (qMRI) requires accurate cartilage and meniscus segmentation, traditionally necessitating time-consuming, costly 3D high-resolution Double Echo Steady-State (DESS) MRI scans. This study developed a multi-task conditional generative adversarial network (MT-cGAN) to simultaneously synthesize DESS-like images and segment tissues directly from qMRI echo images. This retrospective study evaluated 508 knee MRI volumes from 361 subjects (mean age: $40.4 \pm 12.2$ years; 179 female) across three cohorts. Ground truth segmentation masks were generated from DESS images using a pretrained model with manual correction, and $T_{1ρ}$ and $T_2$ maps were computed from magnetization-prepared angle-modulated partitioned $k$-space spoiled gradient echo snapshots (MAPSS) echo images. MT-cGAN was trained to jointly synthesize DESS-like images and segment cartilage and meniscus directly from echo images. Model performance was evaluated using Dice score for segmentation accuracy and coefficient of variation (CV) for $T_{1ρ}$ and $T_2$ quantification. MT-cGAN achieved the highest segmentation performance, mean Dice score 0.84 (range: 0.80--0.86) across all cartilage and meniscus compartments and significantly outperformed the state-of-the-art conditional GAN model with transfer learning (mean Dice, 0.82; $p < 0.001$, Wilcoxon signed-rank test). For relaxometry quantification, MT-cGAN demonstrated the highest consistency with the reference DESS protocol, yielding the lowest CV ($T_{1ρ}$: 1.84%, $T_2$: 1.81%). The proposed MT-cGAN accurately segmented cartilage and menisci while providing reliable $T_{1ρ}$ and $T_2$ quantification directly from echo images. By eliminating the need for separate morphological DESS scans, this workflow reduces required scan times to facilitate the clinical translation of qMRI.

0.22

Automated ACL Footprint Identification Using 3D Deep Learning

cs.CV ·2026-08-18 ·Ruida Cheng, Gabriel Gibson, Ali Uneri, Frances T. Sheehan, Barry Boden
similarity 0.56
Abstract · 10 pages, 5 figures

One of the most common reasons for anterior cruciate ligament (ACL) reconstruction failure is femoral tunnel malpositioning (ACL footprint center and tunnel orientation). Such failures may lead to the development of meniscal pathology and osteoarthritis. Accurate ACL femoral footprint identification is therefore essential for precise tunnel placement, restoration of the native knee joint mechanics, post-surgical knee joint health and prevention of graft failure. Recent advances in artificial intelligence (AI) bring new opportunities to improve image-guided orthopedic surgery. However, at present, existing AI research focuses primarily on ACL segmentation and rupture classification based on pre- and post-operative magnetic resonance (MR) images. Identification of the ACL footprint center using deep learning methods has not been thoroughly researched. Thus, the purpose of this study is to explore 3D deep learning models for ACL femoral footprint identification directly from 3D MR images. Two comprehensive 3D deep learning architectures were developed: a 3D graph convolutional neural network-based geometric model applied to 3D femoral meshes; and a 3D landmark-enhanced identification model based on 3D MR images. A total of 4883 right and 3087 left knee image sets were used from a publicly available database. Eighty percent (80%) were applied to model generation, and twenty percent (20%) were preserved for model testing. Both models achieved excellent performance; however, the image-based method outperformed the model-based method (average error of 2.1mm vs 2.8 mm). Thus, 3D deep learning provides a feasible clinical approach for ACL footprint localization and has the potential to improve ACL reconstruction footprint accuracy.

0.38

KneePreM: Towards 3D Knee MRI Foundation Models via Large-Scale Unlabeled Pretraining and Label-Efficient Fine-Tuning

cs.CV ·2026-09-25 ·Xinxin Wang, Liam Hazan, Jing Li, Simona Rabinovici-Cohen, Xiaojuan Li +1 more
similarity 0.55
Abstract

Background: Large volumes of unlabeled knee MRI scans are available across repositories but remain insufficiently leveraged. We developed KneePreM, a knee-specific 3D self-supervised model, and evaluated transfer and label efficiency for classification and segmentation. Methods: A 3D U-Net masked autoencoder was pretrained on 19,011 unlabeled Osteoarthritis Initiative (OAI) MRI series from 4,791 participants. Downstream fine-tuning used full and reduced training sets for fastMRI+ two-label classification (1,172 examinations), Arthroscopic Partial Meniscectomy (APM) eight-target classification (1,716 examinations), SKM-TEA segmentation (155 examinations), and APM segmentation (25 examinations). Baselines were random initialization and SuPreM. Deployment workflow was implemented with a Model Context Protocol interface. Evaluation metrics included balanced accuracy, F1 score, ROC AUC, PR AUC, and Dice score. Statistical analysis used bootstrap confidence intervals and paired bootstrap tests for classification and Wilcoxon signed-rank tests for segmentation. Results: KneePreM achieved higher full-data macro ROC AUC than both baselines for fastMRI+ and APM (all p < .001). For fastMRI+ classification, KneePreM achieved a ROC AUC of 0.722 using 50% of the training data, exceeding both full-data baselines. In APM classification, KneePreM reached a ROC AUC of 0.740 with 70% of the data, matching the full-data random baseline and outperforming SuPreM. For SKM-TEA segmentation, its 70%-data Dice of 0.838 exceeded the full-data random baseline (0.835) and both same-budget comparators. In APM segmentation, its 75%-data Dice of 0.746 exceeded the full-data random baseline (0.731) and both same-budget comparators. Conclusion: KneePreM improves transfer performance and label efficiency across knee MRI classification and segmentation tasks, particularly when labeled training data are limited.

0.34

A4-MR: Abnormality Aware Anatomical Alignment for MR

cs.CV ·2026-10-09 ·Noel D'souza, Zhijian Yang, Nishank Singla, Pranay Doshi, Krisztian Koos +13 more
similarity 0.55
Abstract

Recent advances in large-scale foundation models have enabled strong generalization across a wide range of clinical and research tasks in magnetic resonance imaging (MRI). However, existing vision-language MRI models remain limited in anatomy-specific localization and pathology-aware representation, particularly in real-world settings. We introduce A4-MR, a 3D vision-language foundation model trained on approximately 50,000 MRI studies comprising 491,000 series, roughly half of which are paired with radiology reports. A4-MR is designed to: (1) learn anatomy localization through large-scale pretraining with noisy labels; (2) align image and text representations at the anatomical level; and (3) learn distinct representations of healthy and abnormal anatomy. Across a diverse set of downstream tasks, A4-MR outperforms existing foundation models, including a +1.7 AUROC improvement over MedSigLIP for abnormality detection. Using a frozen encoder, A4-MR also surpasses an end-to-end task-specific MedNeXt model for knee segmentation by +1.4 Dice and performs comparably to the best task-specific model for abdominal organ segmentation on AMOS, within 0.4 Dice. Finally, without anatomical prompts, A4-MR localizes 3D anatomy comparably to MedSAM2 provided with ground-truth bounding boxes. Together, these results demonstrate that anatomy-level multimodal alignment and abnormality-aware representation learning can enable a single MRI foundation model to support localization, segmentation, and pathology-related tasks.

0.12