CS Paper Radar

3D Reconstruction from Arthroscopic Images using NeRF: a preliminary in-silico study

Hermine Kitio Tsamo, Agathe Yvinou, Daniel Pizarro, Samad Barri Khojasteh, Alexandre Tronchot, Antoine Ferreira, Eric Stindel, Aziliz Guezou-Philippe, Guillaume Dardenne

eess.IV ·submitted 2026-09-30 07:51 UTC · v1
published

Abstract

In knee arthroscopy surgery, accurate registration between preoperative and intraoperative anatomy is a critical step for patient-specific navigation. Achieving an accurate registration requires a reliable 3D reconstruction of the joint during surgery. Preoperative 3D models can be obtained from patient imaging through segmentation and reconstruction, but generating an intraoperative 3D representation remains particularly challenging. Arthroscopic imaging suffers from a limited field of view, low surface texture, and strong specular reflections, which make conventional feature-based 3D reconstruction methods unreliable. In this work, we investigate the application of MIS-NeRF (Minimally-Invasive Surgery Neural Radiance Fields) for reconstructing intraoperative knee 3D models from monocular arthroscopic images. The approach is evaluated on six simulated arthroscopic acquisitions representing six patient-specific knee 3D models. Both qualitative and quantitative results are presented to assess the reconstruction quality. The reconstructed knee 3D models were evaluated through their rendered images, achieving PSNR (Peak Signal-to-Noise Ratio) of 31.88 $\pm$ 2.82, SSIM (Structural Similarity Index) of 0.98 $\pm$ 0.004 and LPIPS (Learned Perceptual Image Patch Similarity) of 0.017 $\pm$ 0.006. These preliminary results suggest the feasibility of NeRF-based reconstruction in the challenging context of arthroscopy and may represent a promising step toward accurate in-silico preoperative-to-intraoperative 3D registration for computer-assisted orthopedic surgery. Further, validation on real arthroscopic data will be necessary to assess clinical applicability.

Journal ref
International Society for Computer Assisted Orthopaedic Surgery (CAOS), Jun 2026, Matusyama, Japan

Closest papers

Nearest neighbours by meaning across the whole index.

Automated ACL Footprint Identification Using 3D Deep Learning

cs.CV ·2026-08-18 ·Ruida Cheng, Gabriel Gibson, Ali Uneri, Frances T. Sheehan, Barry Boden
similarity 0.60
Abstract · 10 pages, 5 figures

One of the most common reasons for anterior cruciate ligament (ACL) reconstruction failure is femoral tunnel malpositioning (ACL footprint center and tunnel orientation). Such failures may lead to the development of meniscal pathology and osteoarthritis. Accurate ACL femoral footprint identification is therefore essential for precise tunnel placement, restoration of the native knee joint mechanics, post-surgical knee joint health and prevention of graft failure. Recent advances in artificial intelligence (AI) bring new opportunities to improve image-guided orthopedic surgery. However, at present, existing AI research focuses primarily on ACL segmentation and rupture classification based on pre- and post-operative magnetic resonance (MR) images. Identification of the ACL footprint center using deep learning methods has not been thoroughly researched. Thus, the purpose of this study is to explore 3D deep learning models for ACL femoral footprint identification directly from 3D MR images. Two comprehensive 3D deep learning architectures were developed: a 3D graph convolutional neural network-based geometric model applied to 3D femoral meshes; and a 3D landmark-enhanced identification model based on 3D MR images. A total of 4883 right and 3087 left knee image sets were used from a publicly available database. Eighty percent (80%) were applied to model generation, and twenty percent (20%) were preserved for model testing. Both models achieved excellent performance; however, the image-based method outperformed the model-based method (average error of 2.1mm vs 2.8 mm). Thus, 3D deep learning provides a feasible clinical approach for ACL footprint localization and has the potential to improve ACL reconstruction footprint accuracy.

0.38

A Joint 2D-3D Statistical Shape Model for Orthopedic Reconstruction

cs.CV ·2026-09-08 ·Florence Dell'Aniello Picard, Pranav Poudel, Nairouz Shehata, Frédéric Lavoie, Herve Lombaert
publishedcode/data similarity 0.60
Abstract · Accepted to MICCAI Workshop on Shape in Medical Imaging (ShapeMI)

Three-dimensional femoral reconstruction from radiographs supports surgical planning, implant sizing, and post-operative follow-up, but remains ill-posed as X-ray projections discard depth information. Existing methods often incorporate a 3D statistical shape model (SSM) as a shape prior to guide reconstructions toward anatomically plausible shapes, relying on iterative 3D-to-2D projection matching. Yet, these approaches are computationally expensive and constrain their SSM to a single dimensionality, leaving the statistical relationship between 2D observations and 3D geometry largely unexploited and unexplored. We instead propose a joint 2D-3D SSM that explicitly captures the co-variation between 2D and 3D segmentations in a shared latent space. During training, 2D and 3D segmentations are registered to a common 3D template and its corresponding 2D projections, and the resulting stationary velocity fields are jointly decomposed using principal component analysis (PCA). This joint modeling allows the 2D-to-3D mapping to be learned directly from data rather than computing correspondences at inference time. For unseen subjects, the 3D shape is recovered directly by lifting the 2D latent coordinates to the 3D PCA subspace, thereby eliminating the need for iterative 3D-to-2D projection. Experiments on NMDID demonstrate that the proposed joint 2D-3D SSM outperforms a widely-used 3D-only SSM baseline while achieving inference approximately 4 times faster, at under 3 seconds per subject. The code is available at: https://github.com/florence-dellaniello-picard/joint2d3d-ssm.

0.42

Multi-Stage NeRF for Efficient 3D Coronary Artery Reconstruction from Two Narrow-Angle Angiographic Projections

cs.CG cs.CV ·2026-09-14 ·Deyu Meng, Mojtaba Lashgari, Yiying Wang, Abhirup Banerjee
top venue similarity 0.59
Abstract · 11 pages, 2 figures

X-ray coronary angiography is the clinical gold standard for coronary artery disease during real-time cardiac interventions, but provides only 2D projections of inherently 3D vessels. Existing learning-based 2D-to-3D reconstruction methods typically require wide angular coverage or multiple views, assumptions that are rarely satisfied in routine practice where only two projections with narrow angular separation are available. To address these challenges, we propose NeCA++, a multi-stage self-supervised neural radiance field (NeRF) framework tailored to clinically realistic acquisition constraints. The framework decomposes reconstruction into two stages that progressively refine spatial support and representation capacity. In the first stage, a coarse 3D representation of the vasculature is reconstructed, restricting the subsequent optimisation to regions with a higher likelihood of vessel presence, termed an active region. Afterward reconstruction is restricted to this region while higher-resolution representations are progressively activated to recover fine vascular details. This multi-stage strategy focuses learning on anatomically plausible regions, mitigates gradient dilution under extreme sparsity, and stabilises global topology before recovering fine vascular branches. Furthermore, two vessel-specific regularisations are introduced: a ray-aligned constraint to reduce projection-induced ambiguity, and a bimodal density penalty to enable early vessel-background separation. Extensive experiments across three datasets (ImageCAS, ASOCA, and Synthetic RCA) and four angular configurations demonstrate consistent superiority over state-of-the-art baselines, particularly under clinically realistic narrow-angle settings, while achieving reconstruction within 58 seconds per case.

0.29

EndoPrior-GS: Dynamic Endoscopic Reconstruction with a Joint Texture Prior

cs.CV ·2026-09-29 ·Jiaqi Huang, Shidong Wang, Tong Xin, Kabita Adhikari
publishedbenchmarkcode/data similarity 0.59
Abstract · Accepted at ACCV 2026. Code: https://github.com/jiaqi-huang-77/EndoPrior-GS

Dynamic endoscopic reconstruction is fundamental to robotic surgery and computer-assisted interventions. While 3D Gaussian Splatting (3DGS) realises real-time rendering, its application to deformable intraoperative environments remains constrained by spurious geometry and varying illuminations. To address these limitations, we introduce EndoPrior-GS, a novel pipeline that explicitly couples frame-extracted vision heuristics and estimated depth maps. EndoPrior-GS derives a joint texture prior from a tool-filtered valid tissue mask, a non-specular photometric filter, and anatomical structural salience, yielding a probability map that guides primitive initialisation and subsequent density control. The prior is further extended to the temporal domain through a texture-aware term that dynamically weighs pairwise primitive contributions during training. We conduct extensive experiments on benchmark datasets EndoNeRF and SCARED, and the obtained results show that our method EndoPrior-GS reduces Flow Error by 27.7% and 25.8% over the representative approaches while preserving competitive rendering quality and real-time rendering speed. Our project website is available at https://jiaqi-huang-77.github.io/EndoPrior-GS/.

0.37

Zero-Shot Monocular Depth Estimation for Visual Perception in Lower-Limb Prostheses

cs.CV ·2026-10-26 ·Ishi Vijayvergiya, Marc Hölle, Youssef Dawoud, Amir El-Ghoussani, Michele De Vita +3 more
publishedbenchmarkdatasetcode/data similarity 0.58
Abstract · Accepted at IEEE International Conference on Integrated Systems in Medical Technologies 2026

Monocular depth estimation has advanced rapidly with the development of foundation models that demonstrate strong zero-shot generalisation across diverse visual domains. However, the applicability of these models to visual perception for lower-limb prosthetics remains largely unexplored. Reliable depth perception is particularly important for prosthesis users, who often experience significant challenges when navigating stairs, uneven terrain, and other complex environments. To address this gap, we introduce the Lower-Limb Prosthesis (LP) dataset, a benchmark designed to evaluate depth perception from an emulated knee-level prosthetic viewpoint. Using this dataset, we evaluate four state-of-the-art monocular depth estimation foundation models. Our results provide the first systematic benchmark of monocular depth estimation performance from a prosthetic viewpoint, while highlighting both the challenges and the potential of deploying foundation models in prosthetic perception systems. The code and dataset are available at https://github.com/Ishivijay/lp_dataset.

0.27

MV-dVRK: A Multi-Viewpoint Benchmark for Spatial Surgical Perception

cs.CV cs.RO ·2026-09-02 ·Guido Caccianiga, Sergey Prokudin, Yutong Chen, Bernard Javot, Rachael L'Orsa +7 more
benchmark similarity 0.58
Abstract

Large-scale training and refined optimization techniques have greatly improved sparse multi-view 3D reconstruction. Despite their relevance to surgery, such methods have never before been rigorously evaluated on real endoscopic images. Current clinical telerobots deploy a single stereo camera inside the patient, making multi-viewpoint data extremely rare. This paper presents MV-dVRK, the first ex-vivo surgical dataset to combine multiple exposure-synchronized stereo viewpoints with accurate surface geometry and camera poses. The static subset of the benchmark provides dense SfM reference geometry, validated against an industrial 3D scanner, together with ground-truth camera poses and sparse-view test sets. We use MV-dVRK to systematically compare zero-shot monocular, stereo, multi-stereo, and multi-view 3D reconstruction methods as the number of viewpoints increases. With two endoscopes, multi-stereo reconstruction achieves the highest coverage. With a third viewpoint, optimization-based multi-view methods perform best, covering 67% of ground-truth surface points within a 1 mm tolerance and recovering highly accurate relative camera poses. By contrast, feed-forward foundation models cover only 43% of the ground-truth surface in the same setting. MV-dVRK also includes ten dynamic sequences spanning multiple surgical tasks, with increasing kinematic complexity and tissue deformation, providing a basis for future research in multi-viewpoint surgical perception. The project is available at: https://mv-dvrk.is.mpg.de.

0.33

KneePreM: Towards 3D Knee MRI Foundation Models via Large-Scale Unlabeled Pretraining and Label-Efficient Fine-Tuning

cs.CV ·2026-09-25 ·Xinxin Wang, Liam Hazan, Jing Li, Simona Rabinovici-Cohen, Xiaojuan Li +1 more
similarity 0.58
Abstract

Background: Large volumes of unlabeled knee MRI scans are available across repositories but remain insufficiently leveraged. We developed KneePreM, a knee-specific 3D self-supervised model, and evaluated transfer and label efficiency for classification and segmentation. Methods: A 3D U-Net masked autoencoder was pretrained on 19,011 unlabeled Osteoarthritis Initiative (OAI) MRI series from 4,791 participants. Downstream fine-tuning used full and reduced training sets for fastMRI+ two-label classification (1,172 examinations), Arthroscopic Partial Meniscectomy (APM) eight-target classification (1,716 examinations), SKM-TEA segmentation (155 examinations), and APM segmentation (25 examinations). Baselines were random initialization and SuPreM. Deployment workflow was implemented with a Model Context Protocol interface. Evaluation metrics included balanced accuracy, F1 score, ROC AUC, PR AUC, and Dice score. Statistical analysis used bootstrap confidence intervals and paired bootstrap tests for classification and Wilcoxon signed-rank tests for segmentation. Results: KneePreM achieved higher full-data macro ROC AUC than both baselines for fastMRI+ and APM (all p < .001). For fastMRI+ classification, KneePreM achieved a ROC AUC of 0.722 using 50% of the training data, exceeding both full-data baselines. In APM classification, KneePreM reached a ROC AUC of 0.740 with 70% of the data, matching the full-data random baseline and outperforming SuPreM. For SKM-TEA segmentation, its 70%-data Dice of 0.838 exceeded the full-data random baseline (0.835) and both same-budget comparators. In APM segmentation, its 75%-data Dice of 0.746 exceeded the full-data random baseline (0.731) and both same-budget comparators. Conclusion: KneePreM improves transfer performance and label efficiency across knee MRI classification and segmentation tasks, particularly when labeled training data are limited.

0.34

THA-Flow Generative Model: Prosthesis Geometry Prediction from Preoperative CT

cs.CV ·2026-08-26 ·Yiping Wang, Jie Li, Jingyu Shen, Liao Wang
similarity 0.58
Abstract · 17 pages, 7 figures, 2 tables

Preoperative planning for total hip arthroplasty (THA) is commonly framed as selecting a single prosthesis configuration and placement for a patient's osseous anatomy. In practice, however, the same anatomy may admit several clinically reasonable solutions, making planning inherently a one-to-many problem that is better represented by a conditional probability distribution. We present THA-Flow, a conditional flow-matching model that generates three-dimensional prosthesis geometry directly from preoperative CT. Separate AutoencoderKL models compress preoperative bone anatomy and prosthesis geometry, while a three-dimensional UNet learns a rectified flow from Gaussian noise to the prosthesis latent space under spatial bone conditioning and optional structured prosthesis parameters. The retrospective cohort comprised 1,355 hips from 1,149 patients undergoing primary THA. Following rigid registration of postoperative CT to preoperative CT, the actual postoperative prostheses were transformed independently according to the pelvic and femoral registrations and represented as a dual-channel truncated signed distance field. The prosthesis autoencoder achieved a peak signal-to-noise ratio of 47.11 dB and a structural similarity index of 0.9964 on the validation set. Complete acetabular and femoral geometries were generated across seven major stem models representing 93.4% of the cohort. Repeated bone-conditioned sampling preserved component position, alignment, and the principal bone-prosthesis interfaces while allowing limited local geometric variation. To our knowledge, THA-Flow represents the first application of generative AI to three-dimensional surgical planning for THA.

0.28