CS Paper Radar

Radiomics-Based Thyroid Nodule Classification with Label-Conditional Conformal Prediction

Laura Testa, Pierpaolo Brutti, Umberto Ferraro Petrillo

eess.IV cs.CVstat.AP ·submitted 2026-10-09 11:01 UTC · v1
published

Abstract

Thyroid nodule malignancy assessment relies on ultrasound imaging, yet current risk stratification systems suffer from substantial interobserver variability, contributing to a high rate of unnecessary biopsies. We propose a radiomics-based framework combining quantitative feature extraction via PyRadiomics with a Generalized Additive Model (GAM) classifier, selected among six candidates for its favorable trade-off between discriminative performance and interpretability. To complement point predictions with uncertainty estimates, Cross-Conformal Prediction with label-conditional guarantees is applied, flagging ambiguous cases for clinical review rather than forcing a binary decision. Experiments are conducted on TN5000, a publicly available ultrasound dataset of thyroid nodules. After Spearman correlation filtering, 36 features are retained and the GAM achieves an AUC of $0.89$, a sensitivity of $0.83$, and a specificity of $0.82$ on the validation set. At a significance level $ε=0.09$, selected to ensure empirical coverage guarantees on both classes, 63\% of nodules on the test set receive a certain (i.e., single-label) prediction, with conditional precision of $0.94$ for certain malignant and conditional Negative Predictive Value (NPV) of $0.73$ for certain benign cases, while the remaining 37\% are referred to the clinician.

Comment
Accepted at the CIBB 2026 conference (https://cibb2026.teralab.ai/)

Closest papers

Nearest neighbours by meaning across the whole index.

Learning to Measure and Diagnose: A Clinical-Dictionary Radiomic Bottleneck Model for Thyroid Nodule Classification

cs.CV ·2026-10-21 ·Guibin Zhang, Weier Luo, Lei Cao
code/data similarity 0.78
Abstract · 9 pages, 2 figures, 2 tables

Thyroid ultrasound supports the assessment of nodule malignancy, but classification predictions often lack evidence linked to familiar clinical descriptions. Radiomics provides explicitly defined measurements that can support such explanations through a clinical dictionary. However, using these measurements as interpretable evidence requires reliable estimation from ultrasound images and preservation of measurement fidelity when optimizing classification performance. We propose a clinical-dictionary radiomic bottleneck model for thyroid nodule classification. Within this model, Family-Aware Radiomic Learning (FARL) estimates measurements with balanced supervision across feature families. Fidelity-Guided Bottleneck Modeling (FGBM) constructs a fixed bottleneck, followed by joint optimization of measurement estimation and classification under fidelity guidance. Decision evidence decomposition then traces feature contributions through a linear classifier and organizes them by clinical dictionary categories. Experiments on ThyroidXL and TN3K show competitive classification performance, while case studies illustrate feature contributions for benign and malignant nodules. These findings indicate interpretable classification with inspectable quantitative evidence informed by clinical knowledge. Code is available online.

0.23

CMCNet: Aligning Ultrasound Image Embeddings with Textual TI-RADS Representations for Fine-Grained Thyroid Classification

cs.CV cs.AI ·2026-08-14 ·Bingxin Yu, Xueli Wang, Jerry Zhou, Wenyan Wang, Li Wen +4 more
datasetcode/data similarity 0.65
Abstract

Ultrasound is the primary imaging modality for assessing thyroid nodules, and the ACR TI-RADS framework standardizes diagnosis through five ultrasound feature categories that are aggregated into five risk levels (TR1-TR5). Although widely adopted in clinical practice, most deep learning approaches focus on binary malignancy classification, while multi-class prediction and explicit utilization of feature-level supervision remain underexplored, largely due to limited annotated data. In this study, we introduce the STN dataset of 600 thyroid nodules with paired transverse and longitudinal ultrasound images, bounding box annotations, and complete labels for all five TI-RADS feature categories. Following the clinical decision process, we investigate how structured feature information can guide representation learning during training while requiring only images at inference. We demonstrate that text embeddings derived from standardized feature descriptions form a stable surrogate representation for TI-RADS risk levels. Based on this observation, we propose CMCNet, which aligns image embeddings to fixed textual embeddings via a Center-Margin Contrastive Loss that simultaneously promotes intra-class compactness and inter-class separation. Experimental results show that this embedding alignment strategy is more data-efficient and robust than direct multitask learning, and consistently outperforms InfoNCE, center loss, a strong multitask baseline, and a VQA-style multimodal model, particularly in imbalanced settings. The dataset is freely available at doi: 10.5281/zenodo.19125693 and the source code is available at: https://www.healthinformaticslab.org/supp/.

0.20

Auditable agentic AI for evidence-grounded thyroid ultrasound diagnosis and reporting

cs.AI cs.CV ·2026-08-12 ·Haifan Gong, Shiyu Chen, Bodong Wang, Yuqi Wang, Shijie Wang +9 more
similarity 0.65
Abstract · Under review

Thyroid ultrasound diagnosis requires coordinated lesion localization, measurement, risk stratification and reporting, yet most AI systems address these tasks in isolation and provide limited support for clinical review. We present ThyroidXAgent, a clinician-interactive agentic AI system that coordinates specialized diagnostic tools and stores their outputs as an auditable case-level evidence record. The system was developed using OpenThyroidDB, a multicentre, multitask resource integrating approximately 0.3 million ultrasound images and 24,000 paired reports, and was evaluated on 28,458 non-overlapping test cases, including 8,721 cases from 35 centres in the private NHC-MISD-TUS cohort. Across heterogeneous datasets, ThyroidXAgent achieved a mean Dice score of 87.21 percent for nodule segmentation and a mean AUROC of 0.9466 for benign-malignant classification. The same workflow supported lymph-node metastasis prediction and follicular versus papillary thyroid carcinoma classification, with AUROCs of 0.864 and 0.805, respectively. For report generation, evidence-grounded assembly outperformed multimodal language-model baselines across three cohorts. ThyClinScore, a lesion-level clinical semantic metric introduced here, showed the strongest correlation with a location-aware language-model judge. ThyroidXAgent improved physician classification accuracy, increased report diagnostic consistency from 70.3 percent to 86.2 percent, and reduced segmentation and reporting time by 35.9 percent and 27.4 percent, respectively. These findings support auditable, clinician-correctable agentic AI for thyroid ultrasound diagnosis and reporting.

0.06

TAM-Chain: Multi-Scale Thyroid Cytology Classification via Absorbing Markov Chains and Shannon Entropy Uncertainty Quantification for False-Negative Suppression and Domain-Shift Adaptation

cs.LG cs.CV ·2026-09-23 ·Hai Pham Ngoc
similarity 0.64
Abstract

Background & Problem: Thyroid Fine-Needle Aspiration Biopsy (FNAB) cytology based on the Bethesda System plays a pivotal role in early thyroid cancer detection; however, deep learning approaches face substantial challenges regarding high false-negative rates and overconfidence under clinical domain shift. Methods: In this study, we propose TAM-Chain, a multi-scale (10x, 20x, 40x) thyroid cytology classification framework leveraging Absorbing Markov Chain theory combined with Shannon Entropy-based Uncertainty Quantification. The framework dynamically models multi-magnification feature extraction as an absorbing stochastic process, enabling optimal stopping criteria and a human-in-the-loop referral mechanism to strictly suppress critical diagnostic errors. Results: Extensive evaluation on an internal test set (N = 235) demonstrates a Macro F1 score of 0.9741 with an absolute False-Negative Rate (FNR) of 0.00%. On an independent external validation set (N = 1015) presenting severe domain shift, TAM-Chain maintains superior stability and classification performance (Macro F1 = 0.7026) by adaptively adjusting the expected stopping step and triggering specialist referrals, significantly outperforming single-magnification baselines. Conclusion: The TAM-Chain framework proves to be a highly effective, safe, and adaptable solution for digital pathology workflows, successfully harmonizing automated diagnostic efficiency with stringent biological safety.

0.23

Radiomics--Foundation Fusion for Interpretable RCC Classification: Internal Benchmarking and Exploratory External Transfer

cs.CV ·2026-09-22 ·Yuan Liang, Fangyijie Wang, Kathleen M. Curran, Guénolé Silvestre, Sourav Bhattacharjee +1 more
published similarity 0.63
Abstract · Accepted for an oral presentation at CaPTion 2026, a MICCAI 2026 workshop. 11 pages, 3 figures

Accurate preoperative subtype classification of renal cell carcinoma (RCC) from contrast-enhanced CT remains clinically challenging because clear cell RCC (ccRCC) and non-clear cell RCC often show overlapping imaging appearances. This study evaluates whether foundation representations reduce reliance on handcrafted radiomics, or whether radiomics remains complementary for interpretable tumour characterisation. We compared radiomics, conventional CNN features, MedicalNet-pretrained features, MedVAE representations, and fusion variants for binary ccRCC classification on KiTS23, reporting area under the receiver operating characteristic curve (AUC) with bootstrap confidence intervals and average precision (AP) as a complementary class-imbalance-sensitive metric. We further assessed branch-removal ablation, TCGA/AIMI external transfer, and interpretability using radiomics permutation importance and gate-level analysis. Internally, 3D MedVAE gated fusion achieved the best performance, with an AUC of 82.7% and AP of 92.2%. On the external TCGA cohort, the same model achieved an AUC of 79.5% and AP of 98.9%, although specificity remains uncertain because only two external non-ccRCC cases were available. Gate analysis showed a radiomics-dominant fusion regime, suggesting that foundation representations acted as case-dependent refinement signals rather than replacements for structured tumour descriptors. These findings support radiomics as a complementary and clinically interpretable component of CT-based RCC characterisation in the foundation-model era.

0.42

Beyond Discrimination: Evaluating Probability Calibration in Radiomics-Image Fusion for Renal Cell Carcinoma Classification

eess.IV cs.AIcs.CVq-bio.QM ·2026-10-09 ·Yuan Liang, Morgan May, Abraham Campbell, Sourav Bhattacharjee, Simon Caton +1 more
top venue similarity 0.63
Abstract · 12 pages. 1 figure. Accepted at the 2026 Irish Conference on Artificial Intelligence and Cognitive Science (AICS 2026). Proceedings forthcom…

Reliable probability estimates are important for the clinical interpretation of machine-learning classifiers, yet radiomics--image fusion models for renal cell carcinoma (RCC) are commonly evaluated primarily by discrimination. Using 396 patients from the KiTS23 dataset, we evaluated whether adding radiomics to four image-model families improved probabilistic performance in addition to discrimination. Seventeen individual models and four probability-average ensembles were assessed using discrimination, probability calibration, and proper scoring measures. Across 12 matched image-only versus fusion comparisons, AUC and AP improved in all 12, while Brier score and negative log likelihood (NLL) improved in 11 of 12 and expected calibration error (ECE) in eight of 12. The 3D MedVAE gated-fusion model achieved the strongest overall individual-model profile. Probability averaging across concatenation, cross-attention, and gated fusion produced favourable point estimates across all five primary metrics relative to image-only models in all four families, although paired-bootstrap support was stronger for Brier score and NLL than for ECE. These findings show that radiomics--image fusion can improve probabilistic prediction quality beyond discrimination, while calibration behaviour varies across image architectures and fusion strategies. We show that our proposed probability-average ensemble models improve discrimination and calibration simultaneously across all architectures in the study.

0.38

A Concept-informed Interpretable Artificial Intelligence Framework for Breast Ultrasound Diagnosis

cs.CV ·2026-10-12 ·Shengzhou Zhong, Ziying Wang, Liang Li, Lihua Yan, Shuochun Chen +12 more
code/data similarity 0.63
Abstract · 31 pages, 17 figures, 4 tables

Most existing artificial intelligence systems for breast ultrasound rely primarily on image-driven prediction, with limited incorporation of the knowledge from the Breast Imaging Reporting and Data System (BI-RADS) and the intermediate assessment processes underlying radiologists' workflow, thereby constraining their interpretability and alignment with clinical practice. We curated, to our knowledge, the largest multicenter collection of breast ultrasound images paired with structured BI-RADS descriptors, comprising 9,941 patients across 20 independent datasets. Across 14 testing datasets, IBUS demonstrated consistent generalization performance across different clinical centers and imaging conditions. Incorporating BI-RADS descriptors enabled fine-grained risk stratification, while cross-checking predicted BI-RADS grades against malignancy probabilities identified internally discordant predictions that may warrant additional clinical review. In a reader study involving eight radiologists, IBUS assistance increased diagnostic sensitivity among both junior and senior readers, with the potential of guiding radiologists to make targeted revision in risk stratification. Overall, IBUS exhibits its potential as a second-stage decision-support system that complements radiologists by providing additional risk estimates and interpretable evidence for diagnostically challenging cases. The demo video of IBUS platform is publicly available at https://github.com/zsz1997/IBUS.

0.30

RadFusion: Towards Threshold-Controllable Radiology Report Generation

cs.AI cs.CLcs.CV ·2026-08-11 ·Ying Jin, Noel C. F. Codella, John Corring, Mu Wei, Dinei Florencio +1 more
similarity 0.61
Abstract

Automated radiology report generation is advancing rapidly in response to the shortage of radiologists, yet unlike a perception model, existing generation models offer no control over the sensitivity-specificity trade-off of their diagnostic content. Such control is essential because clinical scenarios diverge: emergency triage prioritizes sensitivity to reduce missed findings, whereas confirmatory interpretation emphasizes specificity to limit unnecessary interventions. A single fixed report can neither adapt to these scenarios nor support the ROC-based validation widely expected for regulatory clearance. We introduce RadFusion, a framework that equips report generation with threshold controllability. Our method fuses a multi-label classifier, which provides per-disease confidence scores, with a VQA-based report generator, which describes medical findings in detail; an LLM then rewrites the report so that its stated diagnoses follow the classifier's decisions at the selected threshold while staying grounded in the generator's descriptions. On MIMIC-CXR, the performance of RadFusion conforms to the classifier's ROC curve: sweeping the threshold and mapping the reports back to class labels reproduces the classifier's validated ROC performance. This conformance makes generated reports quantitatively evaluable through ROC analysis, strengthening the case for regulatory clearance, and enables operating-point selection that matches report behavior to clinical context. Moreover, combining the two model types improves diagnostic accuracy over uncontrolled generation: sensitivity increases by 6.9% at matched specificity, and specificity by 20.7% at matched sensitivity. These results show that RadFusion makes report generation clinically adaptable, quantitatively verifiable, and diagnostically more reliable.

0.04