CS Paper Radar

Provable Method of Moments for Cryo-EM

Amnon Balanov, Tamir Bendory, Dan Edidin, Josh Katz, Shay Kreymer, Nir Sharon

eess.SP math.NA ·submitted 2026-10-13 07:45 UTC · v1

Abstract

We study the recovery of a three-dimensional volume in single-particle cryo-electron microscopy (cryo-EM) from noisy tomographic projections acquired at unknown viewing rotations, drawn independently and uniformly from $\mathrm{SO}(3)$. We show that, in a spherical-shell representation satisfying an explicit shell-separation condition, the first three moments generically determine the underlying real volume up to its intrinsic global $\mathrm{O}(3)$ ambiguity. The proof is constructive and yields a frequency-marching procedure that successively recovers the volume. Consequently, consistent recovery in the high-noise regime has sample complexity $n=ω(σ^6)$, where $n$ is the number of observations and $σ^2$ is the noise variance. Numerical experiments validate the constructive recovery scheme under finite sampling and additive noise, and indicate that direct third-moment optimization can succeed beyond the structural assumptions required by the constructive proof.

Closest papers

Nearest neighbours by meaning across the whole index.

Image Moment Estimation for Crowded Datasets

eess.IV q-bio.QM ·2026-10-16 ·Andy Zhang, Oscar Mickelin, Amit Singer
similarity 0.64
Abstract · 29 pages, 11 figures

Single-particle cryogenic electron microscopy (cryo-EM) is an imaging technique capable of reconstructing high-resolution three-dimensional (3D) structure of biological macromolecules from a set of noisy projection images taken at random viewing directions. The mathematical model for cryo-EM images typically assumes that each image contains exactly one particle, which is centered at the origin. However, many experimental datasets contain particle images which include multiple particles: one central particle and a few crowding particles. This deviation from the model leads to inaccurate estimation of image statistics, such as the low-order image moments. To account for this, we propose a method to estimate image moments while correcting for the effect of crowding particles. This method can be run directly from a set of cryo-EM micrographs with picked particles, and we demonstrate its efficacy on a wide array of synthetic data.

0.35

Reconstruction-Aware Cryo-EM Particle Picking

cs.CV q-bio.BM ·2026-08-28 ·Riku Itsuji, Yuanhao Wang, Xingjian Li, Seonghui Min, Hideo Saito +1 more
similarity 0.55
Abstract

Cryo-electron microscopy (cryo-EM) determines the structures of proteins and macromolecular assemblies at near-atomic resolution, and the final 3D reconstruction depends on extracting a clean particle stack from noisy micrographs. This extraction decomposes into three sub-tasks, namely particle picking, contamination removal, and 2D class selection. Each of them, however, is trained and evaluated in isolation, and none is optimized for the reconstruction. We instead integrate the three sub-tasks into a single pipeline posed against downstream reconstruction quality. We instantiate the pipeline with a state-of-the-art component for each sub-task, CryoTransformer picking permissively, MicrographCleaner masking contamination, and CryoSift selecting 2D classes by a continuous quality score, and close the loop with a fine-tuning step that returns the surviving particles to the picker. The pipeline achieves a better 3D resolution than every picker we compare. We also show that the best 2D F1 is not the best resolution, so particle selection is better treated as one reconstruction-aware pipeline judged by the map it delivers.

0.23

ARCHER: Amortized cross-specimen pose estimation for cryo-electron microscopy

cs.LG math-phq-bio.BMq-bio.QM ·2026-08-22 ·Nhan D. Nguyen, Bao Pham
published similarity 0.55
Abstract · 28 pages, 15 figures

Single-particle cryo-electron microscopy (cryo-EM) pose estimation is traditionally solved anew for each dataset, where iterative refinement is done from scratch while the estimator learns to store the molecule in its weights. In this work, we show that pose inference is a generalizable, specimen-agnostic operation when conditioned explicitly on a reference volume. We introduce ARCHER, an amortized contrastive classifier that models the pose posterior over a discrete rotation grid. Trained across a variety of protein structures, it operates zero-shot without retraining per structure. This transferability is grounded in Fourier-space information mechanics, where all specimen dependence is captured by the reference structure's power spectrum and spatial extent. ARCHER achieves a median angular error of 5.0° on 100 held-out test structures and 2.5° on experimental particles, matching dedicated estimators within 0.16 Å in 3D reconstruction. Crucially, downstream conformational signal is preserved. The leading conformational coordinate correlates at 0.97 with deposited benchmarks, faithfully reconstructing free-energy basins and mobile domains. These results overall demonstrate that cryo-EM pose estimation can be generalized across different structures.

0.41

BeST: Beta splatted tomography for direct reconstruction from coherent imaging measurements

eess.IV math-phphysics.data-an ·2026-11-13 ·Johannes Gruen, Philipp Paetzold, Andreas Schropp, Aknur Karabay, Shahin Sepanlou +10 more
similarity 0.53
Abstract

Conventional coherent X-ray tomography requires the phase of each projection to be reconstructed with high fidelity. However, individual reconstructed projections might be flawed, e.g. due to positioning errors, yielding inconsistent tomographic reconstructions. By directly coupling phase retrieval and tomography, consistency is enforced through a common object volume. But reconstructing a full volume demands substantial computational resources. To reduce this demand, we introduce Beta Splatted Tomography (BeST), which represents the common object volume using compactly supported beta primitives with closed-form analytical projections, enabling efficient reconstruction directly from coherent scattering images. This representation substantially reduces the number of optimizable parameters compared to a voxel grid. We demonstrate BeST on experimental datasets from hard X-ray near-field holography and far-field ptychography measurements. In both cases, the joint technique improves reconstruction quality compared to two-step methods.

0.21

Statistical Analysis of the Structure from Noise Phenomenon in Generalized Procrustes Problems

cs.IT math.ST ·2026-11-10 ·Jiayang Yin, Shuyang Ling
unusual similarity 0.52
Abstract · 21 pages, 4 figures, 1 table

In cryo-electron microscopy (cryo-EM), observations are highly noisy, and scientists often use reference templates to guide matching, alignment, and averaging to reconstruct the molecular structure. However, these procedures can produce an output resembling the template even when the observations contain only noise, a phenomenon known as Einstein from noise (EfN). This phenomenon has attracted attention in statistics, where simplified observation models involving group actions have been studied to understand the resulting model bias. Characterizing the bias in the full cryo-EM pipeline remains challenging. We study template matching and averaging in the generalized orthogonal Procrustes problem, which provides an analytically tractable setting involving continuous orthogonal group action and lower-dimensional projections of ordered point clouds. We show that, for pure Gaussian noise, the mean of the aligned-and-averaged estimator admits the same left and right singular-vector bases as the template but its singular values may be distorted. This identifies the subspace structure imposed by the template even in the absence of signal. We characterize the singular values and bound their distortion, establish finite-sample operator-norm bounds, and give sufficient sample sizes for the population mean to dominate random fluctuations. In fact, this bias still exists under weak signals: when the template rank is at least the observation dimension, the change from the pure-noise mean is $O(η^2)$ in signal amplitude $η$. Our results provide an explicit characterization of model bias in a registration problem motivated by cryo-EM and show why averaging more observations can stabilize structure imposed by the template without removing the bias.

0.30

MPISuperRes-PnP: A Super-Resolution Zero-Shot Plug-and-Play Reconstruction Algorithm for Magnetic Particle Imaging

cs.CV ·2026-08-10 ·Vladyslav Gapyak, Thomas März, Andreas Weinmann
published similarity 0.50
Abstract · 19 pages, 8 tables

Magnetic Particle Imaging (MPI) is an emerging medical imaging modality. MPI is based on the non-linear response of magnetic nanoparticles to an applied magnetic field and avoids ionizing radiation. The measured signal is the voltage induced in receive coils by the particles' response. Reconstructing the particle concentration from the signal constitutes the imaging task. Even using state-of-the-art measurement-based reconstruction, the associated spatial grid is very coarse, hence super-resolution (SR) techniques are important. In this work, we propose an approach for SR in MPI inspired by energy minimization. Different methods have been proposed for SR in MPI, ranging from upscaling of the associated system matrix to interpolation of the reconstruction. Here we incorporate SR into the reconstruction task via an energy minimization formulation. Following the plug-and-play approach to energy minimization we derive a splitting scheme and a SR method for MPI where the arising Gaussian denoising task is treated with a pre-trained learned Gaussian denoiser in a zero-shot fashion. This way, we incorporate benefits of deep learning without training and avoid the need of training data. Further, we provide a quantitative and qualitative evaluation of the proposed method. Hyper-parameter are selected via an extended parameter search. The found parameters are applied for reconstruction on real data. We show the applicability of our method on synthetic and on real data (MPIData: EquilibriumModelWithAnisotropy and 2D-OpenMPI Data). The proposed method employs a deep-learning denoiser without training -- thus it does not require presently scarcely available MPI training data. The denoiser behaves conservatively, i.e., no hallucination artifacts were observed. The SR approach is generic such that it can be applied in future MPI contexts involving different regularizers or different imaging tasks.

0.28

TopoFuse: Topology-Aware Tri-Planar Fusion for 3D Cryo-Electron Tomography Segmentation

cs.CV ·2026-08-31 ·Rohit Kumar Salla, Neelesh Gupta, Xingjian Li, Min Xu
top venueunusual similarity 0.49
Abstract

Automated segmentation of cryo-electron tomograms routinely produces masks that are voxel-accurate but topologically broken: membranes fragment, organelles merge into one another, and enclosed cavities collapse. Existing topology-aware losses reduce these violations but cannot eliminate them, because topology is encouraged through gradient pressure rather than structurally enforced. We introduce TopoFuse, which reframes topology as a differentiable projection operator rather than a loss penalty. At each forward pass, the projection operator $\mathrm{Proj}_T$ (a PH-guided sparse edit) identifies the critical voxels responsible for topological violations via bottleneck matching and applies sparse edits to satisfy a specified topology target (diagram feature counts and lifetime budgets) for dimensions $d \in \{0,2\}$. If the projection converges, the output satisfies those constraints on the downsampled grid ($s=2$); when it does not, a repair certificate exposes this explicitly, enabling downstream filtering. A topology prior head predicts the correction target directly from input features, removing any dependence on ground-truth topology at inference. Across three cryo-ET benchmarks, TopoFuse reduces Betti number error by 54% over the strongest soft-loss baseline ($p < 0.001$), improves Dice by 4.6 points, and edits only 3.1% of voxels to achieve this.

0.44

Fold'EM: Direct atomic structure inference from Cryo-EM particles

cs.AI q-bio.BM ·2026-10-01 ·Advaith Maddipatla, Märt-Erik Mäeots, Marco Pegoraro, Nikolaus Dräger, Roberto Covino +3 more
similarity 0.49
Abstract

Single-particle cryo-electron microscopy (cryo-EM) has become a widely adopted technique for biomolecular structure determination. The conventional cryo-EM computational pipeline first combines many particle images to reconstruct an electrostatic potential (ESP) map and then fits an atomic model to the recovered map. Density reconstruction has high sample complexity, requiring large numbers of particle images and making structure determination high-cost and low-throughput, particularly for heterogeneous samples. Downstream atomic model building, in turn, becomes increasingly difficult as the resolution of the reconstructed map deteriorates. Protein structure prediction models provide strong sequence-derived priors on atomic structure, and experiment-guided approaches can use these priors to recover structures consistent with experimental measurements. Yet, in cryo-EM, such priors are typically integrated only after density reconstruction during atomic model fitting. We introduce Fold'EM, an inference-time framework that combines priors from protein generative models directly with cryo-EM particle images to determine atomic models from a small number of single particle images, bypassing both intermediate density reconstruction and downstream model building against the reconstructed map. Across synthetic and experimental cryo-EM datasets, Fold'EM recovers accurate atomic structures both with known particle orientations and in an ab-initio setting where orientations are inferred jointly with structure. In heterogeneous datasets, Fold'EM further resolves distinct conformational states from mixed particle populations without separately reconstructing a density map and building an atomic model for each state. We believe these results open new avenues for structure determination in the low-sample regime and for characterizing low-population conformational states directly from cryo-EM particles.

0.16