CS Paper Radar

MPISuperRes-PnP: A Super-Resolution Zero-Shot Plug-and-Play Reconstruction Algorithm for Magnetic Particle Imaging

Vladyslav Gapyak, Thomas März, Andreas Weinmann

cs.CV ·submitted 2026-08-10 14:47 UTC · v1
published

Abstract

Magnetic Particle Imaging (MPI) is an emerging medical imaging modality. MPI is based on the non-linear response of magnetic nanoparticles to an applied magnetic field and avoids ionizing radiation. The measured signal is the voltage induced in receive coils by the particles' response. Reconstructing the particle concentration from the signal constitutes the imaging task. Even using state-of-the-art measurement-based reconstruction, the associated spatial grid is very coarse, hence super-resolution (SR) techniques are important. In this work, we propose an approach for SR in MPI inspired by energy minimization. Different methods have been proposed for SR in MPI, ranging from upscaling of the associated system matrix to interpolation of the reconstruction. Here we incorporate SR into the reconstruction task via an energy minimization formulation. Following the plug-and-play approach to energy minimization we derive a splitting scheme and a SR method for MPI where the arising Gaussian denoising task is treated with a pre-trained learned Gaussian denoiser in a zero-shot fashion. This way, we incorporate benefits of deep learning without training and avoid the need of training data. Further, we provide a quantitative and qualitative evaluation of the proposed method. Hyper-parameter are selected via an extended parameter search. The found parameters are applied for reconstruction on real data. We show the applicability of our method on synthetic and on real data (MPIData: EquilibriumModelWithAnisotropy and 2D-OpenMPI Data). The proposed method employs a deep-learning denoiser without training -- thus it does not require presently scarcely available MPI training data. The denoiser behaves conservatively, i.e., no hallucination artifacts were observed. The SR approach is generic such that it can be applied in future MPI contexts involving different regularizers or different imaging tasks.

Comment
19 pages, 8 tables

Closest papers

Nearest neighbours by meaning across the whole index.

Cascaded Posterior Sampling With Diffusion Priors for highly Accelerated MRI

eess.IV ·2026-10-25 ·Jyothi Rikhab Chand, Sahil Murtaza, Patrick Nicholas Nowak, Mathews Jacob
similarity 0.58
Abstract

Diffusion models are powerful priors for inverse problems, including accelerated MRI. However, modeling the distribution of high-resolution images requires large networks with high computational cost. We propose a posterior sampling framework that uses cascaded diffusion models as multiscale priors. Conditioned on a coarse image, the distribution of fine-scale detail is local and well conditioned, and it can therefore be captured by a small network. Similarly, a small unconditional network is sufficient to represent low-resolution images, and it is used to recover the coarse image from the k-space center. This estimate then conditions the high-resolution prior, which is combined with all measurements to recover the final image. Both priors are trained on images alone, so they apply to any sampling pattern, and data consistency remains linear at every scale. In multi-coil brain MRI, the proposed method improves on the best single-scale diffusion baseline by 4-6 dB in PSNR at 15x acceleration, while each of its separately trained networks is about 10x smaller. The gain grows as the problem becomes more ill-posed, and ablations show that it arises from informative low-resolution conditioning.

0.06

Harnessing Magnitude-Only and Complex Measurements for Improved Dynamic MRI Reconstruction with Learned Priors

eess.IV cs.AIcs.CVcs.LG+1 ·2026-08-18 ·Mahdi Saberi, Yaşar Utku Alçalar, Merve Gülle, Chetan Shenoy, Mehmet Akçakaya
top venue similarity 0.57
Abstract · To appear in IEEE TBME

MRI reconstruction methods for undersampled k-space data naturally utilize complex-valued measurements. Parallel developments in sparse phase retrieval have shown that magnitude-only measurements may provide complementary information for signal recovery. However, their use in MRI reconstruction remains largely unexplored, due to lack of practical settings where informative magnitude measurements can be obtained without additional scan time. In this work, we investigate the use of auxiliary k-space magnitude information for accelerated steady-state dynamic MRI reconstruction, and demonstrate strong consistency of k-space magnitudes across time-frames. Building on this observation, we propose $\mathbb{C}+\text{Mag}$, a magnitude-informed physics-driven deep learning reconstruction method. The proposed method employs an ADMM-based unrolling framework with a novel magnitude-aware data-fidelity formulation, where quadratically smoothed optimization and momentum-based updates are introduced to address the non-differentiability and non-convexity of the magnitude constraints. Experiments on retrospectively undersampled cine MRI and phase-contrast flow MRI datasets, as well as prospectively undersampled real-time cine MRI acquisitions, demonstrate improved artifact suppression, sharper anatomical recovery, and better preservation of phase information compared to conventional PD-DL methods, which is further supported through blinded expert reader evaluations.

0.44

Complex Domain Inverse Problem Formulation for 4D Flow MRI Super-Resolution

eess.IV ·2026-10-24 ·Aurélien de Turenne, Denis Kouamé
similarity 0.57
Abstract · 5 pages

Four-dimensional flow magnetic resonance imaging measures blood velocity fields in three dimensions throughout the cardiac cycle and is increasingly used to assess hemodynamics. However, these measurements are limited by low signal-to-noise ratios and limited spatial resolution, which can compromise their accuracy and reliability. To address these limitations, we investigate the feasibility of spatial resolution enhancement through a complex-domain inverse problem formulation inspired by MRI acquisition principles. Three inversion methods are evaluated: a closed-form approach (FSR), a Plug-and-Play alternating direction method of multipliers (PnP-ADMM), and a pretrained network that takes the forward operator as input (RAM). On simulated data, all three methods outperform 4DFlowNet at x2 and x4 super-resolution factors. On aortic phantom data at x2 super-resolution, PnP-ADMM and RAM achieve lower root-mean-square error than 4DFlowNet in almost all cases. These results highlight the potential of the proposed formulation and support further development and validation.

0.25

Physics-informed denoising method for image reconstruction in quantitative low-field MRI

eess.IV ·2026-09-11 ·Catarina Redshaw Kranich, Claudia Prieto, Christoph Kolbitsch, Felix Frederik Zimmermann
similarity 0.56
Abstract

Low-field magnetic resonance imaging (MRI) is becoming increasingly important for medical imaging because it can reduce healthcare costs while ensuring high diagnostic output. Nevertheless, quantitative imaging in low-field MRI faces challenges, such as low signal-to-noise ratio and long scan durations. Deep learning approaches have been proposed for image reconstruction to overcome these challenges. Still, deep learning often requires large high-quality training datasets which are usually not available for low-field applications. Here we propose a modular unrolled end-to-end deep learning method for the denoised reconstruction of quantitative parameter maps directly from k-space data for low-field MRI. It consists of three sub-networks that are iteratively applied. They are used for the regularization of the quantitative parameter estimation, as well as for the signal estimation that is based on simulated signal curves. It generalises well and can be applied to different field strengths and even different quantitative MR sequences without the need for new training data. We applied the presented method to noisy data of knees acquired at 0.55 T for the reconstruction of $T_2$-maps and compared it to other classical and deep learning methods. We also applied the proposed approach to $T_1$-mapping of knees at 72 mT and $T_2$-mapping of brains at 0.6 T. The presented approach outperforms the other reconstruction methods with a median difference below 4 ms to the ground truth $T_2$-map. Even though the network was trained with $T_2$-maps acquired at 0.55 T, it successfully denoised data acquired at different field strengths, sequences, and of different anatomies. As a result, the proposed network and its underlying method offer an efficient and flexible solution to denoise low-field MR data and make quantitative low-field MRI a feasible diagnostic tool for clinical applications.

0.13

PGDM-MRSRGAN: Physics-Guided Degradation Model with an SRGAN Framework for Magnetic Resonance Image Super-Resolution: Applications in Low-Field MRI

eess.IV physics.med-ph ·2026-09-24 ·Yashwant Kurmi, Charlotte R. Sappo, Sai Abitha Srinivas, Selin D. Kandemir, Malvika Viswanathan +1 more
similarity 0.56
Abstract · 28 pages, 10 figures, 5 supporting information tables

Magnetic Resonance Imaging (MRI) often suffers from low signal-to-noise ratio (SNR) and limited spatial resolution, which compromise clinical precision. This study aims to address these challenges by developing a physics-guided degradation model (PGDM) and a novel deep learning framework, Magnetic Resonance Super-Resolution GAN Imaging (MRSRGAN), for improved super-resolution reconstruction of MRI images. The proposed approach consists of two stages: (1) a physics-guided degradation model that simulates low-field MRI conditions by incorporating artifacts such as blur, B0 inhomogeneity, chemical shift effects, down-sampling, and noise to generate paired low-resolution (LR) and high-resolution (HR) training datasets; and (2) an MRSRGAN-based reconstruction network utilizing a hybrid loss function, including modified spectral angle mapper (MSAM) and sharpened ground truth images based on de-convolution of slice profile-based kernels to restore high-SNR and high-resolution images. Experimental validation demonstrates that the proposed method achieves superior spatial resolution, enhanced SNR, improved peak signal-to-noise ratio (PSNR), higher structural similarity index (SSIM), reduced MSAM error, and better non-reference image quality evaluation (NIQE) metrics. Furthermore, it effectively reduces artifacts and demonstrates robustness on real MRI datasets. The MRSRGAN framework, guided by the physics-informed degradation model, provides a significant improvement in MRI image quality, enhancing spatial resolution and diagnostic accuracy. Its demonstrated robustness and effectiveness on real MRI datasets highlight its potential to resolution enhancement for precise diagnostic imaging.

0.27

Tissue-Mixture Entropy-Weighted Reconstruction for Partial-Volume-Aware Brain MRI Super-Resolution

cs.CV ·2026-08-27 ·Xiao Tong, Wenyun Yang, Ziheng Zhang, Jingzhi Han, Zhaochu Luo +1 more
similarity 0.55
Abstract · 17 pages, 6 figures, 8 tables

Background and Objectives: Full-image objectives in brain magnetic resonance imaging (MRI) super-resolution (SR) can underweight tissue-transition regions affected by the partial-volume effect (PVE), as these regions occupy a small fraction of the image. Binary boundaries further provide only a discrete approximation of continuous tissue mixtures within a voxel. Methods: We propose Anatomy-Guided Gaussian-Parameter Warping with PVE-Balanced Reconstruction (AGW-PBR), combining a low-resolution (LR)-only reconstruction backbone with a PVE-aware training objective. The backbone uses LR-derived anatomical guidance, soft latent assignment, and bounded residual warping. Quality-controlled tissue fractions are converted into tissue-mixture entropy to spatially weight reconstruction within validated PVE support. PVE sidecars are used only during training, while inference requires only the LR image. Downstream utility is further evaluated through zero-shot transfer to whole-tumor segmentation on BraTS2023. Results: AGW-PBR improves reconstruction across 2x and 4x SR on IXI and achieves the lowest normalized gradient-vector reconstruction error at both CSF--GM and GM--WM interfaces at 4x. Ablation studies verify the contributions of PVE-aware weighting and soft latent assignment. The PVE-free AGW backbone also maintains strong performance on fastMRI. On BraTS2023, AGW-PBR achieves competitive whole-tumor Dice and the lowest HD95 under direct zero-shot transfer. Conclusions:AGW-PBR improves brain MRI SR while preserving tissue-transition information relevant to downstream analysis. The results support tissue-mixture entropy as an effective supervision signal for partial-volume-aware MRI reconstruction.

0.35

MedGSSR: Generalizable Medical Image Super-Resolution 3D Reconstruction via Hierarchical Feed-forward Gaussian Splatting

eess.IV cs.CEcs.CVq-bio.QM ·2026-09-06 ·Chengkai Wang, Luoyu Hong, Yiting Zhao, Jiamin Wang, Xiang Feng +5 more
top venue similarity 0.55
Abstract · ECCV 2026

High-resolution volumetric medical imaging is critical for clinical diagnosis, yet acquisition is often limited by scanner hardware, scan time, and for CT, radiation dose. Medical 3D Super-Resolution (Med3DSR) offers a computational alternative, but existing methods commonly rely on per-subject optimization, pretrained priors, or coordinate-based implicit representations, which compromise anatomical fidelity and limit efficiency. To address these limitations, we present MedGSSR, a fully end-to-end feed-forward framework that represents volumes as an explicit 3D Gaussian field for Med3DSR. Unlike coordinate-based implicit functions, our explicit 3D Gaussian representation naturally enhances signal continuity and local high-frequency fidelity. Specifically, MedGSSR explicitly decouples the reconstruction process into coarse-grained structural preservation and fine-grained textural refinement through the proposed Pyramid Anatomical Encoder and a Hierarchical Gaussian Projector. To support arbitrary-scale super-resolution, we introduce sub-voxel Gaussian decomposition and a Differentiable Gaussian Voxelizer that directly queries the continuous 3D intensity field, reducing discretization artifacts. Extensive experiments on MRI and CT benchmarks demonstrate that MedGSSR significantly outperforms state-of-the-art methods. Notably, our framework exhibits robust generalizability across unseen datasets without requiring per-subject optimization, enabling fast inference and high-fidelity volumetric super-resolution in practical clinical settings. Our project webpage, including code, is at https://william2ai.github.io/medgssr

0.47

UMPIRE-Net: Unrolled Magnitude-Phase Regularization Network for Accelerated MRI

eess.IV cs.CVeess.SPphysics.med-ph ·2026-08-14 ·Mahdi Saberi, Toygan Kiliç, Mehmet Akçakaya
code/data similarity 0.54
Abstract · IEEE International Workshop on Machine Learning for Signal Processing (MLSP)

MRI reconstruction from undersampled k-space measurements is an ill-posed inverse problem. Physics-driven deep learning (PD-DL) methods have shown strong performance for this task by combining the MRI forward model with learned image regularization within algorithm-unrolling frameworks. However, most existing PD-DL methods reconstruct complex-valued images directly, thereby implicitly coupling magnitude and phase within a single learned representation. This coupled regularization may be suboptimal in reconstruction settings where accurate phase modeling plays an important role, such as partial Fourier (PF) imaging, where recovery of the omitted asymmetric k-space measurements depends on the underlying image phase. In such scenarios, explicit modeling of magnitude and phase as separate components may reduce the reliance on externally estimated or predefined phase information. To this end, we propose UMPIRE-Net (Unrolled Magnitude-Phase In REgularization Network), a PD-DL method that introduces separate learned regularizers for magnitude and phase components, together with a novel data-fidelity formulation that enforces measurements consistency. We evaluate UMPIRE-Net for accelerated MRI with PF across different datasets and acceleration factors. Experimental results demonstrate that our proposed method improves reconstruction quality compared with a conventional complex-valued PD-DL baseline, yielding sharper images and reduced artifacts. Code available at: https://github.com/MahdiSaberii/UMPIRE-Net

0.59