CS Paper Radar

PGDM-MRSRGAN: Physics-Guided Degradation Model with an SRGAN Framework for Magnetic Resonance Image Super-Resolution: Applications in Low-Field MRI

Yashwant Kurmi, Charlotte R. Sappo, Sai Abitha Srinivas, Selin D. Kandemir, Malvika Viswanathan, Zhongliang Zu

eess.IV physics.med-ph ·submitted 2026-09-24 18:24 UTC · v1

Abstract

Magnetic Resonance Imaging (MRI) often suffers from low signal-to-noise ratio (SNR) and limited spatial resolution, which compromise clinical precision. This study aims to address these challenges by developing a physics-guided degradation model (PGDM) and a novel deep learning framework, Magnetic Resonance Super-Resolution GAN Imaging (MRSRGAN), for improved super-resolution reconstruction of MRI images. The proposed approach consists of two stages: (1) a physics-guided degradation model that simulates low-field MRI conditions by incorporating artifacts such as blur, B0 inhomogeneity, chemical shift effects, down-sampling, and noise to generate paired low-resolution (LR) and high-resolution (HR) training datasets; and (2) an MRSRGAN-based reconstruction network utilizing a hybrid loss function, including modified spectral angle mapper (MSAM) and sharpened ground truth images based on de-convolution of slice profile-based kernels to restore high-SNR and high-resolution images. Experimental validation demonstrates that the proposed method achieves superior spatial resolution, enhanced SNR, improved peak signal-to-noise ratio (PSNR), higher structural similarity index (SSIM), reduced MSAM error, and better non-reference image quality evaluation (NIQE) metrics. Furthermore, it effectively reduces artifacts and demonstrates robustness on real MRI datasets. The MRSRGAN framework, guided by the physics-informed degradation model, provides a significant improvement in MRI image quality, enhancing spatial resolution and diagnostic accuracy. Its demonstrated robustness and effectiveness on real MRI datasets highlight its potential to resolution enhancement for precise diagnostic imaging.

Comment
28 pages, 10 figures, 5 supporting information tables

Closest papers

Nearest neighbours by meaning across the whole index.

Physics-informed denoising method for image reconstruction in quantitative low-field MRI

eess.IV ·2026-09-11 ·Catarina Redshaw Kranich, Claudia Prieto, Christoph Kolbitsch, Felix Frederik Zimmermann
similarity 0.65
Abstract

Low-field magnetic resonance imaging (MRI) is becoming increasingly important for medical imaging because it can reduce healthcare costs while ensuring high diagnostic output. Nevertheless, quantitative imaging in low-field MRI faces challenges, such as low signal-to-noise ratio and long scan durations. Deep learning approaches have been proposed for image reconstruction to overcome these challenges. Still, deep learning often requires large high-quality training datasets which are usually not available for low-field applications. Here we propose a modular unrolled end-to-end deep learning method for the denoised reconstruction of quantitative parameter maps directly from k-space data for low-field MRI. It consists of three sub-networks that are iteratively applied. They are used for the regularization of the quantitative parameter estimation, as well as for the signal estimation that is based on simulated signal curves. It generalises well and can be applied to different field strengths and even different quantitative MR sequences without the need for new training data. We applied the presented method to noisy data of knees acquired at 0.55 T for the reconstruction of $T_2$-maps and compared it to other classical and deep learning methods. We also applied the proposed approach to $T_1$-mapping of knees at 72 mT and $T_2$-mapping of brains at 0.6 T. The presented approach outperforms the other reconstruction methods with a median difference below 4 ms to the ground truth $T_2$-map. Even though the network was trained with $T_2$-maps acquired at 0.55 T, it successfully denoised data acquired at different field strengths, sequences, and of different anatomies. As a result, the proposed network and its underlying method offer an efficient and flexible solution to denoise low-field MR data and make quantitative low-field MRI a feasible diagnostic tool for clinical applications.

0.13

MRI Super-Resolution with RCDM/WaveMix and Task-Aware Segmentation

cs.CV ·2026-09-30 ·Kavitha Viswanathan, Harsh Choudhary, Amit Sethi
similarity 0.64
Abstract

Super-resolution and quality enhancement of 1.5\,T brain MRI are normally validated with image-fidelity metrics, although their purpose is to improve downstream analysis. We study whether enhancement improves tissue segmentation, and for which segmenters. We propose an unpaired, physics-guided training pipeline for a lightweight ($\le$2.5\,M parameter) recurrent convolutional enhancer: a six-module stochastic 1.5\,T degradation operator, a residual adversarial network that adds scanner-specific texture without moving anatomy, and a cycle-consistent objective with an anti-identity penalty that rules out the copy solution. We then train U-Net, Swin-UNet and wavelet token-mixing segmenters \citep{jeevan2023wavemix} from scratch on either raw or enhanced 1.5\,T images of the same subjects, using identical labels and subject-level splits, for three enhancer variants and two datasets. On ABIDE (41 held-out subjects, FreeSurfer labels) enhancement significantly improves the wavelet segmenter (mean Dice $+0.014$, Wilcoxon $p=3.5\times10^{-5}$; CSF $+0.018$, grey matter $+0.013$), significantly degrades the U-Net ($-0.008$, $p=5.1\times10^{-4}$) and leaves Swin-UNet unchanged. On IXI, whose labels come from FSL-FAST, enhancement lowers Dice for all nine pairings, almost entirely through CSF; we trace this to spatially implausible CSF voxels in the labels that penalise smoother predictions. Enhancement of low-field MRI should therefore be validated per downstream model and against reliable labels.

0.14

Consistency Models for Fast MRI Reconstruction Using Regularization by Denoising

eess.IV cs.AIcs.CVcs.LG+1 ·2026-08-20 ·Merve Gülle, Junno Yun, Yaşar Utku Alçalar, Mehmet Akçakaya
code/data similarity 0.63
Abstract

Diffusion models (DMs) have emerged as powerful generative priors for MRI reconstruction with promising results. Yet DM-based methods require extensive iterative refinement, limiting their practical deployment. Consistency models (CMs) provide a compelling alternative, aiming to map out the diffusion trajectory in a single pass, enabling faster generation. In this work, we propose CM-RED, a novel MRI reconstruction method that integrates a pretrained CM into the regularization by denoising (RED) scheme. Our method builds on accelerated proximal gradient RED (RED-APG), and further incorporates controlled noise injection during the update steps to enhance generative diversity and accelerate convergence. Extensive experiments on the fastMRI knee and brain datasets demonstrate that CM-RED achieves high-quality reconstructions across multiple anatomies, contrast weights, acceleration factors, and undersampling patterns, using only 4 network function evaluations (NFEs). The proposed method consistently outperforms existing DM- and CM-based approaches in both quantitative metrics and visual fidelity, and exhibits strong robustness to hyperparameter variations, highlighting CM-RED as an efficient and effective generative framework for accelerated MRI reconstruction. The source code and pretrained models are publicly available at https://github.com/MerveGulle/CM-RED.

0.31

GAN-Diff : Coupling Pretrained WGAN-GP Features with Conditional Diffusion U-Nets

cs.CV cs.AIcs.LG ·2026-08-23 ·Saif Ahmed, Asadullah Hil Galib, S. M. Riaz Rahman Antu, Ahmed Faizul Haque Dhrubo, Souvik Pramanik +3 more
similarity 0.63
Abstract · 7 pages, 10 figures, 4 tables

Generative adversarial networks (GANs) can provide efficient image generation, while diffusion models offer high-quality image restoration but require iterative sampling. This paper presents a hybrid GAN-guided diffusion framework that uses a pretrained Wasserstein GAN with gradient penalty (WGAN-GP) as a feature prior for conditional diffusion-based image restoration. Intermediate features from the frozen WGAN-GP generator are incorporated into a diffusion U-Net through cross-attention and remain fixed during the DDIM sampling process. The framework is evaluated on two restoration tasks, Gaussian denoising and 2Xsuper-resolution, using CelebA face images. During development, several sources of instability were identified and addressed, including adversarial learning-rate imbalance, inappropriate diffusion initialization, excessive corruption, and insufficient parameter averaging. The resulting framework consistently improves the quality of both degraded and low-resolution images. In particular, it improves denoising performance by 4.40 dB in PSNR and super-resolution performance by 3.70 dB over their respective input baselines. These results demonstrate the potential of a frozen GAN feature prior to guide diffusion models toward stable and effective image restoration.

0.16

Prior-Guided Implicit Neural Representations for Single-Subject Diffusion MRI Super-Resolution

eess.IV cs.CV ·2026-09-01 ·Abdulkader Ghandoura, Marsil Zakour, William Consagra, Yogesh Rathi
publishedcode/data similarity 0.63
Abstract · Accepted at the British Machine Vision Conference (BMVC) 2026. 16 pages, 5 figures, 2 tables. Project page: https://abdulkaderghandoura.gith…

Resolving complex fiber geometries in brain white matter requires high-resolution diffusion MRI at the cost of long acquisition times. This leads many clinical protocols to opt for low-resolution scans, making downstream microstructure estimation and tractography challenging. Implicit neural representations (INRs) can model the diffusion signal continuously, enabling native single-subject super-resolution by querying the network at arbitrary spatial coordinates, yet existing methods often suffer from long training times and lack a mechanism to incorporate anatomical priors to regularize super-resolution by constraining the space of plausible reconstructions. To address these limitations, we propose a novel transfer-learning framework that pre-trains an INR on a high-resolution template and then adapts it to subject-specific scans via registration and fine-tuning. For $4\times$ through-plane super-resolution from 5 mm to 1.25 mm on Human Connectome Project (HCP) data, our method reduces NRMSE by 36-49% and increases FSIM by 24-43% over a recent baseline with $6\times$ faster training, outperforming competing INR-based methods across both image quality and domain-specific metrics. Code is available on the project page at https://abdulkaderghandoura.github.io/research/msc-thesis/ .

0.80

Coarse-to-Fine 3D MRI Reconstruction via Resolution-Agnostic Neural Operators

eess.IV cs.CV ·2026-11-11 ·Jiayun Wang, Ram Daftari, Weijie Gan, Valentin Duruisseaux, Ruibo Wang +3 more
published similarity 0.63
Abstract · NeurIPS 2026

Deep-learning-based 3D MRI reconstruction is limited in practice by the GPU memory and compute cost of full-volume training; 3D acquisitions are thus most often reconstructed by 2D models applied slice-by-slice and then stacked, which ignores through-plane (stacking-axis) structure. We reconstruct in full 3D and ask whether a model can be trained at low resolution (fast and memory-feasible) yet deployed at higher resolution. This coarse-to-fine strategy needs reliable cross-resolution performance, but standard networks are resolution-specific and degrade substantially when evaluated outside the training setting. We therefore use resolution-agnostic neural operators (NOs) and propose KIR-NO (k-space-to-Image Reconstruction Neural Operator), a discretization-agnostic framework for accelerated 3D MRI reconstruction. KIR-NO is trained with full backpropagation on low-resolution volumes and applied zero-shot to higher-resolution volumes at inference. Its core building block is a 3D neural operator based on discrete-continuous convolutions: convolutional filters are parameterized in a continuous basis and sampled at arbitrary voxel resolutions while preserving the local inductive bias of convolution. KIR-NO integrates these learned operators with physics-based consistency: a k-space neural-operator head first refines the undersampled Fourier measurements, and image-space neural-operator cascades then refine the reconstruction through interleaved data-consistency updates. Across 3D knee and brain MRI benchmarks, KIR-NO improves over classical and CNN baselines: it improves over a state-of-the-art 3D CNN by 2.2 dB PSNR at half resolution under 4x acceleration on SKM-TEA, with gains persisting at 8x and 16x. These results show that resolution-agnostic operators make coarse-to-fine 3D MRI reconstruction - cheap low-resolution training with high-resolution deployment - practical across anatomies.

0.27

Motion Artifact-Aware Self-Supervised Representation Learning for 3D Brain MRI Motion Artifact Reduction

cs.CV physics.med-ph ·2026-08-10 ·Mojtaba Safari, Shansong Wang, Zach Eidex, Matthew Goette, Tonghe Wang +2 more
top venue similarity 0.62
Abstract

Patient motion remains a source of image degradation in brain MRI, leading to signal loss, blurring, and geometric distortion that compromise quantitative analysis. Existing deep learning methods for motion correction typically rely on paired clean-corrupted data or k-space acquisitions, which are rarely available in clinical settings. We propose SSRL-MAR, a motion artifact-aware unpaired representation learning framework for motion artifact reduction that requires neither paired training data nor explicit motion labels. SSRL-MAR employed a three-stage training strategy: (1) contrastive learning on 3D patches to extract motion representations by contrasting clean and synthetically corrupted images, (2) a motion artifact-aware synthesis network to generate motion artifacts from clean scans, and (3) a motion artifact-aware generator to restore clean volumes using the learned degrader for self-supervised supervision. On in-silico dataset, SSRL-MAR achieved PSNR 23.81dB, SSIM 91.55%, and NMSE 0.79%. On in-vivo MR-ART dataset, the pretrained model reduced motion distortion, and unsupervised domain adaptation further improved anatomical fidelity. Against a source-only supervised model trained on the same simulated pairs, SSRL-MAR improved PSNR by up to 2.0 dB on MR-ART after unsupervised domain adaptation, and remained within 0.25-0.47 dB of an oracle supervised model that requires real paired data unavailable in practice. At the milder motion level, volumetric error in structures such as the corpus callosum and ventricular system decreased by more than 50%, confirming improved neuroanatomical consistency. These results indicate that SSRL-MAR provides a robust and scalable image-domain solution for 3D brain MRI motion correction, enabling reliable structural quantification in large-scale neuroimaging studies without requiring prospectively acquired pairs or acquisition-specific calibration.

0.29

Beyond MSE: Rician Likelihood Denoising for Self-Supervised Cardiac $T2$ and $T1ρ$ MRI

eess.IV cs.CV ·2026-09-24 ·Nicholas A. Jacobs, Jason Mendes, Ravi Ranjan, Edward DiBella, Shireen Elhabian
similarity 0.62
Abstract · Made minor spelling and punctuation corrections

Magnetic resonance imaging involves an inherent trade-off among spatial resolution, acquisition time, and noise. This trade-off contributes to long scan times and high cost. Deep learning has improved image denoising, but cardiac MRI remains difficult because high-resolution, rapid acquisitions generally lack corresponding low-noise ground truth. Self-supervised denoising offers a potential solution by learning from noisy image pairs or even single noisy acquisitions. However, we show that Noise2Void-style blind-spot denoising, which uses a mean squared error (MSE) loss and assumes zero-mean, independent and identically distributed (i.i.d.) noise, is poorly suited to MR magnitude images. When applied to short-axis $T2$-weighted and $T1ρ$-weighted cardiac MRI with synthetic Rician noise, it produces biased denoised images and biased parametric maps of $T2$ and $T1ρ$. To address this limitation, we formulate self-supervised denoising as maximum likelihood estimation under a known Rician noise model. This yields unbiased denoisers that are competitive with supervised baselines.

0.22