CS Paper Radar

RetinaSC: Retinal Semantic Communication Framework for Diabetic Retinopathy Detection

Avani Shinod, Rangineni Rushitha, Asqeem Nas, Anirban Bhowal, Shikha Baghel

eess.SP ·submitted 2026-10-13 17:52 UTC · v1

Abstract

This paper presents a lightweight semantic com- munication framework for diabetic retinopathy (DR) grading from fundus images pertaining specifically to the APTOS2019 dataset. The framework includes semantic encoder designed using ResNet34, U-Net, MobileNetV2, and EfficientNet-B0 architectures. Further, the trained models are used to train the same framework for IDRiD dataset using transfer learning approach. Such a framework will enable the telemedicine sector in the early detection of DR and prevent total blindness. The results reveal that for APTOS, task-oriented semantic systems can achieve satisfactory robust performance (more than 0.8 weighted F1 score for ResNet34 and EfficientNet-B0) across different channels. In particular, considering the trade-off between complexity, latency, throughput, and F1 score, MobileNetV2 is the best model with weighted F1 score of 0.76-0.78 for both task and reconstruction- oriented modules and end-to-end latency of only 8.162 ms.

Closest papers

Nearest neighbours by meaning across the whole index.

ORViT-DR: Ordinally-Robust Hybrid ViT for Low-Resolution Diabetic Retinopathy Grading

eess.IV cs.CV ·2026-08-16 ·Soumit Kumar Kundu, Nabil Ashab, Bidhan Biswas, Shahadat Hossain Sohag, Saif Mahmud Parvez +2 more
published similarity 0.69
Abstract · Accepted at ECCT 2026

Diabetic retinopathy (DR) is one of the main causes of impaired vision. A good and reliable automated grading system can make the screening process safer and more accurate. Because DR stages progress gradually, the task of grading disease severity naturally follows an ordinal structure in which neighboring classes share similar visual characteristics. In this study, ORViT-DR, a hybrid deep learning framework, is designed to improve DR grading from low-resolution retinal images. The proposed approach combines convolutional feature extraction with transformer-based global context modeling through a pre-trained ViT-Hybrid backbone, which integrates BiT-ResNetv2 with a Vision Transformer architecture. The approach is tested on the RetinaMNIST subset of the MedMNISTv2 dataset, which contains 28x28 retinal fundus images annotated with five levels of disease severity. To promote stable training and better feature learning, the training strategy applies progressive layer unfreezing, layer-wise learning rate decay, exponential moving average (EMA) parameter updates, and ensemble-based prediction during inference. Experimental results on the official RetinaMNIST test set show that the proposed method achieves 57.00% classification accuracy, along with a quadratic weighted kappa score of 0.5963 and a macro-F1 score of 0.4293. These results suggest that hybrid CNN-Transformer architectures can provide effective representations for ordinal retinal image analysis.

0.19

Explainable Diabetic Retinopathy Classification Using Vision Foundation Models

cs.CV cs.LG ·2026-08-28 ·Abhishek Verma, Anila Krishna, Abhishek Gajanan Bankar, Juan Miguel Lopez Alcaraz
code/data similarity 0.69
Abstract · 17 pages, 4 figures, source code under https://github.com/UOLMDA26/retinopathy_vision_foundational

Diabetic retinopathy (DR) is a leading cause of preventable blindness, and automated screening must be both accurate and trustworthy. We study an explainable DR classification framework built on vision foundation models and three transfer learning strategies. Three backbones, DINOv2, CLIP, and Vision Transformer (ViT), were adapted by full fine-tuning, linear probing, and Low-Rank Adaptation (LoRA). Models were trained and internally evaluated on the ODIR dataset and externally evaluated on APTOS to assess generalization. DINOv2-LoRA achieved the highest internal AUROC (0.758), whereas DINOv2 and ViT full fine-tuning achieved the highest external AUROC (0.920). Probability calibration was assessed with reliability analysis after isotonic regression. For explainability, Grad-CAM and HiResCAM maps were compared with expert-annotated lesion masks from the IDRiD dataset using Dice, Intersection over Union (IoU), and Pointing Game metrics. The results show that foundation models, particularly DINOv2, provide strong predictive performance, and that LoRA is a parameter-efficient alternative to full fine-tuning. Spatial overlap between explanation maps and annotated lesions was limited (mean Dice of about 0.13 for the combined lesion mask), which highlights the value of quantitatively testing whether model attention corresponds to clinically relevant retinal lesions.

0.23

LightHybridNet: A Lightweight Hybrid Deep Learning Framework for Efficient Multi-Label Ophthalmic Disease Classification in Imbalanced Fundus Images

eess.IV ·2026-10-14 ·Hem Raj Dadral Najam Ul Hasan, Naveed Ejaz, Muhammad Aslam Jarwar
similarity 0.67
Abstract

Eye diseases are a major global cause of blindness and vision impairment, highlighting the need for accurate and early diagnosis to prevent further deterioration. Despite advances in medical imaging, classifying retinal diseases from fundus images remains challenging due to the complexity and subtlety of visual features. This study aims to develop and validate LightHybridNet, a novel lightweight hybrid deep learning framework, to improve the classification of eye diseases from fundus images. The model incorporates architectural features, such as depthwise separable convolutions and compound scaling mechanisms, to enhance diagnostic accuracy and robustness. To validate the model, the ODIR-5K dataset, comprising 8 disease categories, was used. To enhance image quality, pre-processing approaches were applied, including histogram equalisation, colour space conversion, and contrast adjustment, resulting in high-resolution images. Furthermore, image augmentation was employed to increase the dataset size, thereby improving the model's ability to generalise during training. The hybrid architecture helps the model concentrate on relevant image regions while capturing and integrating details at different scales, significantly improving classification performance. To evaluate its effectiveness, the model was compared with transfer-learning models. The results show that LightHybridNet outperforms the baselines, achieving a weighted F1-score of 91.51%, a macro AUC of 98.26%, and a Cohen's Kappa of 90.14% on the validation set. Furthermore, model interpretability was enhanced using explainable AI methods, including Grad-CAM, to identify and emphasise features influencing the decision-making process. LightHybridNet represents a promising advancement in automated ocular disease detection, offering improved diagnostic reliability for clinical use.

0.20

FOCUS: Benchmarking Retinal Model Generalization from Foundation Vision Encoders to Multimodal LLMs

cs.CV cs.AI ·2026-09-27 ·David Restrepo, Chenwei Wu, Luis Filipe Nakayama, Miguel L. Martins, Stergios Christodoulidis +2 more
top venuebenchmarkdatasetcode/data similarity 0.67
Abstract · Accepted at NeurIPS 2026, Evaluations & Datasets Track. Interactive benchmark dashboard: https://huggingface.co/spaces/dsrestrepo/FOCUS-Reti…

Progress in AI-based retinal image analysis has accelerated with the adoption of foundation models, yet evaluating their real-world reliability remains challenging. Performance reported on a single dataset does not capture how models behave under dataset shift, across clinical definitions, or for different patient subgroups. This limitation is particularly critical in medical imaging, where robustness, calibration, and fairness are essential for safe deployment. We introduce FOCUS (Foundation Ophthalmic Cross-Dataset Understanding under Shift), a cross-dataset benchmark evaluating retinal fundus models across vision-only encoder models (VM), vision-language dual-encoder models (VLM), and multimodal large language models (MLLM). FOCUS harmonizes binary diabetic retinopathy, referable diabetic retinopathy, and glaucomatous optic neuropathy tasks across ten public datasets spanning diverse geographies, acquisition conditions, and label protocols. The benchmark evaluates models through a unified analysis layer that measures ranking performance, calibration, subgroup disparities, and image-quality robustness. We present a large-scale evaluation covering 532 base configurations and 228 MLLM configurations adapted via LoRA fine-tuning. Results show no model family consistently dominates across tasks and datasets: general VM encoders achieve the strongest average ranking performance, medical MLLMs are competitive but variable, and dual-encoder VLMs benefit substantially from lightweight adaptation. Fine-tuning improves in-domain performance but exhibits heterogeneous transfer to external datasets, particularly in calibration. FOCUS provides a practical framework and public benchmark to assess generalization, reliability, and robustness beyond single-dataset leaderboards.

0.52

From Canon to Nikon: Camera Domain Shift and Potential Equity Implications in Retinal AI

cs.CV cs.CY ·2026-10-21 ·Lisa Y. W. Tang
similarity 0.65
Abstract

Diabetic retinopathy is a leading cause of preventable blindness, yet access to regular screening remains limited worldwide. AI offers a scalable approach, but its performance can be sensitive to image quality and acquisition conditions. In a Brazilian cohort of 8,524 patients, retinal images acquired with the Nikon NF5050 were more than twice as likely to have inadequate image quality compared with those acquired with the Canon CR-2, despite refurbished Canon systems costing more than twice as much as Nikon systems. This potential cost-quality trade-off highlights an important consideration for the reliability of AI systems deployed across heterogeneous imaging systems. Using a frozen pretrained retinal foundation model, we systematically evaluate whether camera-associated performance differences persist across 12 retinal disease classification tasks, four input resolutions, and five downstream classifiers. We find that camera-associated performance differences vary substantially across tasks, and that neither higher input resolution nor classifier choice consistently mitigates cross-camera variation. These findings identify camera platform as a potentially overlooked source of performance variability, with implications for the safety and reliability of retinal AI when deployed across heterogeneous imaging systems. We release all source code, evaluation scripts, and per-task results on GitHub to support reproducible benchmarking.

0.24

CAMEL: Cross-Architecture Masked Embedding Learning for Ultra-Lightweight Retinal Foundation Models

cs.LG cs.AIcs.CV ·2026-10-29 ·Andre Guarnier De Mitri, Giovani Decico Lucafo, Miller Matheus Lima Anacleto Rocha, Diego Furtado Silva
similarity 0.65
Abstract · 8 pages, 6 figures, pre-print

Recent progress in deep learning has substantially advanced automated grading of ophthalmologic pathologies, supported by large annotated datasets and improved representation learning. However, a significant gap remains between state-of-the-art performance and clinical scalability. In particular, foundation models have reshaped image-based medical screening and diagnosis. These large-scale architectures trained on extensive datasets learn rich, generalizable feature representations that can be adapted to a wide range of downstream tasks. In ophthalmology, RETFound, one of the most relevant foundation models for retinal images, performs strongly across classification, segmentation, and risk prediction tasks. Despite their effectiveness, foundation models are often computationally prohibitive, hindering their deployment in real-world clinical environments where hardware constraints and latency are critical. To bridge this gap, we introduce CAMEL (Cross-Architecture Masked Embedding Learning), a novel cross-architecture distillation framework that uses an asymmetric masking strategy during embedding learning to effectively transfer knowledge from massive teacher foundation models to compact, lightweight student models. Our experimental evaluation across four datasets shows that CAMEL preserves accuracy while drastically reducing computational complexity, enabling lightweight yet highly accurate models suitable for resource-limited clinical settings.

0.21

Lesion-Aware Explainable AI for Diabetic Retinopathy Grading from Fundus Images

cs.CV cs.AI ·2026-11-14 ·Truong Thinh Nguyen, Hai Phong Nguyen, Truong Thanh Hung Nguyen, Giang Son Tran, Hung Cao
similarity 0.64
Abstract · 12 pages, 6 figures, 9 tables. Truong Thinh Nguyen and Hai Phong Nguyen contributed equally. Corresponding author: Truong Thinh Nguyen

Post-hoc explanations of deep-learning models for diabetic retinopathy (DR) grading are difficult to trust because different attribution methods highlight different retinal regions for the same image, and a visually plausible heatmap does not show that the highlighted pixels drive the prediction. We propose the Consensus-Calibrated Explanation Map (CCEM), which fuses Grad-CAM++, Ada-SISE, and SmoothGrad Integrated Gradients (SG-IG) using image-specific weights derived from annotation-free reliability cues: deletion sensitivity, inter-method agreement, compactness, retinal containment, and peak structure. CCEM explains a frozen ordinal grader, an EfficientNet-B7 with CBAM and a scalar regression head, pre-trained on EyePACS 2015 in Stage 1 and fine-tuned on APTOS 2019 in Stage 2 with quadratic weighted kappa (QWK)-optimized thresholds; it reaches a QWK of 0.920 on the hidden Kaggle test set and 0.559 on the external MAPLES-DR cohort. Explanations are evaluated on MAPLES-DR, 198 MESSIDOR images with expert pixel-level lesion annotations that are never used for training, threshold fitting, or fusion. On the 193 images with annotated lesions, CCEM obtains the highest Soft Pointing Game score (69.61%; 95% CI 63.7-75.3), defined as the ratio of the strongest lesion-supported saliency to the global map maximum rather than a lesion detection rate, together with the lowest deletion AUC (0.570) and the best deletion-insertion balance (0.115); each gain is significant against the strongest single explainer on paired tests. Annotation-free, per-image reliability weighting therefore turns three disagreeing explainers into one map whose peak evidence is more lesion-supported and more faithful to the model than that of any single explainer.

0.13

Interpretable Fundus Image Classification via Ring-Based Retinal Vasculature Features

cs.CV stat.ML ·2026-08-25 ·Xiaoyan Li, Shixin Xu, Arvind Gupta, Huaxiong Huang
similarity 0.62
Abstract

Retinal fundus photography is widely used for screening and monitoring ocular diseases, but many modern classification pipelines rely on deep latent representations and provide limited interpretability. This study develops an interpretable fundus image classification framework based on a ring-structured representation of the retinal vasculature centered on the optic disc. The method quantifies vessel geometry, color appearance, oxygenation-related vascular appearance, and vessel--background entropy within concentric retinal regions. These physiologically motivated descriptors are derived from vessel masks, image intensities, and optical-density measurements and aggregated across rings to capture spatial variation in vascular properties. Using only quantitative vascular descriptors, the proposed method achieved strong classification performance across three public fundus datasets. On HRF, it achieved 91.1\% accuracy using automatically generated vessel masks, matching RETFound, a vision transformer pretrained on large-scale retinal fundus image data, under the same evaluation setting. Additional analyses suggest that pretrained image models are sensitive to acquisition-related spatial cues, including fundus scale and retinal position within the field of view, as well as broader non-vessel image characteristics. This framework may support interpretable disease classification, quantitative retinal phenotyping, and retinal biomarker discovery without requiring large task-specific training datasets.

0.44