CS Paper Radar

A$^3$PreCore: Robust Rigid Registration for Native FLAIR-Space Brain-Mask Transfer

Elmira Mirzabeigi, Zahra Khalilzad, Taylor Snowden-Richardson, Jesus Eduardo Lugo Arce, Jodie R. Gawryluk, Brian R. Christie, Jocelyn Faubert

cs.CV eess.IV ·submitted 2026-10-14 17:48 UTC · v1
unusual

Abstract

Reliable brain-mask transfer into native fluid-attenuated inversion recovery (FLAIR) space can fail when T1-to-FLAIR rigid registration is unstable. We developed A$^3$PreCore, a six-degree-of-freedom rigid-registration strategy that aligns the full bias-corrected T1-weighted image to native FLAIR using normalized mutual information while preserving the established T1-space anatomical mask. We also introduced extended quantitative quality control (E-QC), which characterizes mask extent, field-of-view-relative position, FLAIR intensity support, boundary support, inferior morphology, and pairwise geometric disagreement. In 78 participants with paired T1-weighted and FLAIR imaging, A$^3$PreCore was compared with fsl_anat and the Brain Extraction Tool (BET). Gross rigid-body misregistration occurred in 21/78 fsl_anat outputs (26.9%) and 0/78 A$^3$PreCore outputs (exact two-sided McNemar p=9.54 x 10^-7). Among 57 participants without gross fsl_anat misregistration, A$^3$PreCore preserved close agreement (median Dice=0.993; median paired Delta NMI=-0.00007, p=0.429). A$^3$PreCore remained broadly concordant with BET (median Dice=0.955), with less inferior and extracranial extension in representative comparisons. Method-blinded neuroscientists ranked A$^3$PreCore first in 35/40 participants (87.5%). E-QC additionally exposed severe orientation-related disagreement not evident from global descriptors or centroid displacement alone. These findings support A$^3$PreCore as a robust native-FLAIR brain-mask transfer strategy and E-QC as a complementary framework for multidimensional mask characterization and participant-specific geometric quality control.

Closest papers

Nearest neighbours by meaning across the whole index.

Learning Where to Trust: Reliability-Guided Expert Routing and Velocity Gating for 3D Deformable Registration

cs.AI cs.CV ·2026-10-27 ·Chenyu Guo, Wenjie Dai, Yiqian Chang, Zhiyuan Zhang, Yunfan Wei +4 more
hot direction similarity 0.56
Abstract

Deformable image registration relies on accurate anatomical correspondences. However, explicitly coupling local matching reliability with spatial context selection and deformation update strength remains insufficiently explored in learning-based registration. This challenge is particularly pronounced in homogeneous, weakly textured, and severely deformed regions, where ambiguous matches may induce erroneous deformation updates. We propose ReliMorph, a reliability-routed symmetric framework for 3D deformable registration that couples correspondence assessment with spatial context selection and update strength.Local correlation distributions characterize correspondence ambiguity using shared anatomical features with modality-specific adaptation. These reliability cues guide spatial expert fusion and gate residual velocities during coarse-to-fine refinement. Updated inverse-inconsistency feedback guides routing and gating at finer pyramid levels. To our knowledge, ReliMorph is the first 3D deformable registration framework to jointly condition spatial expert routing and residual velocity gating on correspondence reliability. Extensive experiments demonstrate that ReliMorph consistently outperforms competing methods in anatomical overlap, highlighting its effectiveness across unimodal and multimodal registration tasks.

0.20

The Right Prior for the Right Deformation: Rethinking Continuous Deformable Image Registration

cs.CV ·2026-08-17 ·Hengjie Liu, Chushu Shen, Dan Ruan, Ke Sheng
code/data similarity 0.56
Abstract

Deformable image registration models implicitly encode deformation priors through their parametrization and optimization. In this work, we conduct a validation study on continuous registration methods to examine how these implicit priors affect performance across different registration tasks. Classic B-Spline transformations impose locality, smoothness, and scale through their control-point structure, whereas recent INR-based methods impose different priors through neural parameterization and optimization. We compare INR-Dense (IDIR), which directly models a dense displacement field using a SIREN-based INR; INR-BSCP (SINR), which predicts B-Spline control points with an INR; D-BSCP, which directly optimizes single-scale B-Spline control points; and MR-D-BSCP, which adds a multiresolution coarse-to-fine scheme. Experiments on inter-subject brain MR registration (OASIS) and intra-subject exhale-to-inhale lung CT registration (DIR-LAB 4DCT) reveal different behavior across deformation regimes. On OASIS, where deformations are moderate but locally complex, D-BSCP matches or slightly outperforms INR-BSCP, suggesting that the B-Spline parameterization accounts for much of INR-BSCP's effectiveness. On DIR-LAB 4DCT, where respiratory motion is larger and more coherent, single-scale B-Spline methods (D-BSCP and INR-BSCP) are less suitable, while INR-Dense and MR-D-BSCP are more effective. Across both tasks, MR-D-BSCP achieves the best performance among the tested continuous parameterizations. These findings highlight that registration accuracy depends strongly on matching the induced deformation prior to the target motion pattern, and support prior-deformation matching as a practical design principle for medical image registration. Our code will be available at https://github.com/HengjieLiu/RightPriorDIR.

0.44

Architectural and Regularization Components in Deep Learning Medical Image Registration: Systematic Ablation Study

cs.CV cs.LG ·2026-08-23 ·Nabira Rashid
similarity 0.54
Abstract · 15 pages, 1 figure

Deep learning registration methods routinely stack two kinds of enhancement on a base network: architectural additions such as affine pre-alignment stages, and training-objective additions such as regularization losses. Papers tend to adopt both at once, so it is unclear which is doing the work. I ran a controlled ablation to separate them. Using the OASIS brain MRI dataset (394 training subjects, 20 test subjects), I trained four variants of the same registration pipeline: a baseline 3D U-Net with basic similarity losses, the same U-Net with a full regularization suite, an affine-plus-deformable architecture with basic losses, and the affine architecture with the full suite. I evaluated registration accuracy (MSE, NCC, SSIM), deformation quality (Jacobian determinant preservation, displacement statistics, an anatomical plausibility score), and computational cost. Regularization alone accounted for most of the gain: a 21.3% relative gain on the MSE-improvement metric (1.78% to 2.16%, P<.001) and a 21.8% relative gain in NCC improvement, while cutting maximum deformation from 53.1 to 0.51 units, a 99.0% reduction, at essentially no computational cost (-0.06% inference time). The combined model produced the largest accuracy gain, 25.8% (1.78% to 2.24%), and raised anatomical plausibility from 0.596 to 0.930, at a moderate +9.8% inference-time cost. Gradient correlation rose from 0.742 at baseline to 0.980 for the fully enhanced model. All enhanced variants reached sub-voxel accuracy under plausible deformation constraints. Regularization losses are the primary driver in this setting, delivering the accuracy gains and almost all of the deformation control for free at inference time, while the affine architecture adds a smaller complementary benefit at acceptable cost. The 99% reduction in unrealistic deformations addresses a known barrier to clinical deployment.

0.24

Anatomically Faithful Artifact Suppression in SENSE Accelerated Brain MRI

eess.IV cs.CV ·2026-09-18 ·Changjing Chai, Bin Huang, Libo Xu, Jian Zhou, Boyang Pan +3 more
similarity 0.54
Abstract · 18 pages of main text, 2 pages of appendix, 6 figures, and 6 tables (including 2 appendix tables)

Background: Four-fold accelerated sensitivity encoding (SENSE4) can shorten brain MRI acquisition time but may amplify noise and result in residual aliasing artifacts after conventional reconstruction. Purpose: To evaluate whether an image-domain refinement framework can improve the quality of SENSE4 brain MRI while preserving anatomical information for quantitative measurements. Methods: In this prospective paired study, 80 participants underwent fully sampled and four-fold accelerated SENSE T1-weighted MRI. We developed an Anatomy-aware Residual Attention Network (ART-Net) to refine accelerated reconstructions through generalized self-attention and correlation-based residual artifact regularization. Participant-level splitting yielded training, validation, and independent test cohort (45/5/30 participants). The independent test cohort underwent quantitative, segmentation-based, and blinded radiologist assessments of image quality and anatomical preservation. Results: ART-Net demonstrated highly competitive reconstruction performance, achieving the highest peak signal-to-noise ratio (31.03 +/- 2.88 dB) and structural similarity index (0.963 +/- 0.022) among evaluated methods. It also demonstrated improved anatomical fidelity, with numerically highest Dice coefficients for medial temporal structures relevant to atrophy assessment (0.8824 +/- 0.0827) and whole-brain regions (0.8857 +/- 0.0885). Moreover, ART-Net improved gradient fidelity, regional contrast preservation, and radiologist-rated structural quality. Conclusion: ART-Net improved agreement between SENSE4 and fully sampled T1-weighted images in a single-center, held-out test cohort while maintaining segmentation-derived anatomical measurements. These findings suggest that ART-Net may support accelerated brain MRI by improving image fidelity and enabling reliable downstream anatomical analysis.

0.23

FlexiMIND: Combined Pretrained Vision Features and Local Structure for Training-Free Deformable Medical Image Registration

cs.CV physics.med-ph ·2026-10-25 ·Mojtaba Safari, Mingzhe Hu, Shansong Wang, Suyang Xi, Joshua Lorenz +4 more
code/data similarity 0.54
Abstract

Objective. Deformable image registration remains challenging because corresponding anatomy may exhibit different intensity relationships. Hand-crafted modality-robust descriptors such as Modality-Independent Neighborhood Descriptor with Self-Similarity Context (MIND-SSC) and features from pretrained vision encoders provide distinct representations for correspondence estimation, but how they should be combined remains unclear. We investigate whether tighter integration improves registration over a sequential, scale-separated design. Approach. We introduce FlexiMIND, a training-free and label-free two-stage framework in which frozen FlexiCT-2D encoder features establish contextual correspondence and MIND-SSC refines the deformation within ConvexAdam. Five alternative feature-coupling strategies were evaluated under a protocol across CT-CT (DIR-Lab 4DCT 4DCT, 10 cases), MR-MR (ACDC, 50 patients), and MR-CT (Learn2Reg Abdomen MR-CT, 8 pairs) registration. Performance was assessed using target registration error (TRE), Dice similarity coefficient (Dice), SDlogJ, and local folding. Main results. FlexiMIND achieved a TRE of 1.27 mm on DIR-Lab 4DCT, a DSC of 0.807 on ACDC, and an organ-averaged DSC of 0.825 on Abdomen MR-CT. Across 15 coupling-strategy dataset comparisons, only four outperformed the reference method, with a maximum absolute improvement of 0.0043 in Dice, whereas degradation reached 20.6 % in TRE and 37.9 % in Dice. Changes in registration accuracy were closely associated with changes in deformation-field regularity, and strategies that better preserved regularity generally remained closest to the reference performance. Landmark-level analysis showed that the pretrained encoder stage primarily reduced large correspondence errors rather than uniformly improving local precision. Code is available upon acceptance at https://github.com/mosaf/FlexiMIND.

0.24

Meta-Initialization of Implicit Neural Representations to Accelerate Deformable Medical Image Registration

cs.CV cs.LG ·2026-10-27 ·Marat O. Zinovev, Dmitry V. Sorokin
published similarity 0.53
Abstract · 14 pages, 5 figures, 2 tables. English-language author version of a paper presented at GraphiCon 2026, Saint Petersburg, Russia, 22-24 Septe…

Implicit neural representation (INR) methods for deformable medical image registration require the network parameters to be optimized for each new image pair, making adaptation speed a practical limitation. This work investigates whether early adaptation can be accelerated using an initialization learned from a collection of previously solved registration tasks. We examine two schemes: Reptile meta-initialization and STRAINER transfer of the shared component of a coordinate network. KAN-IDIR is used as the base INR displacement-field model. Experiments are conducted on OASIS-1, with 364 consecutive pairs used for training and 49 pairs for test-time adaptation. Registration quality is evaluated using mean Dice and HD95, together with the fraction of voxels with a negative Jacobian determinant at iteration 1500. In the configurations studied, both schemes yield higher Dice and lower HD95 at early iterations than random initialization. Reptile numerically outperforms STRAINER under a small iteration budget, although their pretraining budgets are not matched. As the number of iterations increases, the differences between the schemes shrink. STRAINER pretraining takes 39-40 minutes, compared with 44.98 hours for Reptile.

0.28

Is Deformable Image Registration Ready for Brain Metastasis Reirradiation Dose Accumulation? A Longitudinal MRI Benchmark of Registration Accuracy

eess.IV cs.CV ·2026-08-27 ·Hengjie Liu, Manju Sharma, Xinyi Fu, Di Xu, Ke Sheng
benchmark similarity 0.53
Abstract

Dose accumulation is increasingly important in adaptive radiation therapy and reirradiation, but its clinical validity depends on the performance of deformable image registration (DIR). Reirradiation of brain metastases (BMs) with stereotactic radiosurgery (SRS) provides a controlled but clinically meaningful DIR test case: intra-subject brain deformation is usually limited after rigid alignment, yet recurrent lesions can undergo substantial local shape and volume changes that rigid registration cannot capture and can affect dose accumulation. We benchmarked a wide range of learning-based and optimization-based DIR methods on 87 manually screened longitudinal contrast-enhanced T1-weighted MRI lesion pairs from an institutional BM SRS retreatment cohort. Learning-based methods pretrained on healthy-brain MRI were evaluated zero-shot and after instance-specific optimization (ISO) or tumor-proximity target-specific optimization (TSO). Registration was assessed using lesion overlap (Dice), surface distance metrics (HD95 and sASD), target-volume recovery, and runtime and memory. Pretrained learning-based methods showed variable zero-shot performance, while ISO/TSO improved all tested learning-based families. However, optimization-based methods remained the best-performing approach while maintaining reasonable runtime. These findings suggest that even state-of-the-art DIR methods do not yet provide sufficiently accurate and consistent registration for unmonitored use in brain metastasis reirradiation dose accumulation. Because accurate registration is a prerequisite for deformable dose accumulation, clinical application will require case-level quality control and direct assessment of how registration uncertainty affects downstream dose metrics.

0.21

VariaFlow: Uncertainty-Aware Flow Matching for Unsupervised Anomaly Detection

cs.CV ·2026-10-30 ·Arnela Hadzic, Martin Urschler, Cosmin I. Bercea
published similarity 0.53
Abstract · Accepted for WACV 2027

Reconstruction-based anomaly detection no longer fails at reconstruction. Generative models produce high-quality pseudo-healthy reconstructions, and the remaining difficulty is the step of scoring residuals. The residual between a scan and its reconstruction has two indistinguishable sources, genuine pathology and the anatomical variation that separates one healthy brain from another. Scoring against a single reconstruction treats both as anomalous, inflating false positives where healthy anatomy varies most while small or subtle lesions are lost in the surrounding reconstruction error. We identify the missing quantity as the predictive variance, how much a healthy reconstruction can vary at each location. We introduce VariaFlow, which estimates this variance from an ensemble of mask-guided restorations under an unconditional flow matching prior, each started from a different noise initialization, and which normalizes the residual by the resulting standard deviation. Few-step flow matching keeps the ensemble computationally affordable, and restoring at two spatial scales captures lesions of different size. Across three brain MRI datasets spanning stroke and tumor, VariaFlow is trained once on healthy anatomy and generalizes across all three, attaining the highest AUROC (0.94, 0.80, 0.78) on each and the highest AUPRC on both cross-domain datasets, exceeding the strongest baseline by 37% and 50%. Under domain shift, the same baseline drops by up to 52% in AUPRC, whereas VariaFlow stays more stable and achieves the best small-lesion Dice on all three datasets.

0.29