Abstract

Dose accumulation is increasingly important in adaptive radiation therapy and reirradiation, but its clinical validity depends on the performance of deformable image registration (DIR). Reirradiation of brain metastases (BMs) with stereotactic radiosurgery (SRS) provides a controlled but clinically meaningful DIR test case: intra-subject brain deformation is usually limited after rigid alignment, yet recurrent lesions can undergo substantial local shape and volume changes that rigid registration cannot capture and can affect dose accumulation. We benchmarked a wide range of learning-based and optimization-based DIR methods on 87 manually screened longitudinal contrast-enhanced T1-weighted MRI lesion pairs from an institutional BM SRS retreatment cohort. Learning-based methods pretrained on healthy-brain MRI were evaluated zero-shot and after instance-specific optimization (ISO) or tumor-proximity target-specific optimization (TSO). Registration was assessed using lesion overlap (Dice), surface distance metrics (HD95 and sASD), target-volume recovery, and runtime and memory. Pretrained learning-based methods showed variable zero-shot performance, while ISO/TSO improved all tested learning-based families. However, optimization-based methods remained the best-performing approach while maintaining reasonable runtime. These findings suggest that even state-of-the-art DIR methods do not yet provide sufficiently accurate and consistent registration for unmonitored use in brain metastasis reirradiation dose accumulation. Because accurate registration is a prerequisite for deformable dose accumulation, clinical application will require case-level quality control and direct assessment of how registration uncertainty affects downstream dose metrics.

Closest papers

Nearest neighbours by meaning across the whole index.

Personalising Deformable Image Registration with Clinical Context and Deformation History for Adaptive Radiotherapy

eess.IV cs.AI ·2026-10-13 ·Caiwen Jiang, Songlin Zhao, Yuzhen Ding, Jia Mi, Samir H. Patel +21 more
benchmark similarity 0.76
Abstract · 27 pages, 7 figures and 6 tables. The submission includes Supplementary Information

Adaptive radiotherapy must account for anatomical changes during treatment, but doing so depends on reliably mapping targets, organs at risk and dose across serial images. Existing registration methods treat each image pair independently, without using radiotherapy-specific context or the patient's preceding anatomical trajectory. We developed Clinical-context-Aware and Patient-adaptive Deformable Image Registration (CAP-DIR), integrating source contours, dose, clinical text and prior-registration features. We evaluated 16,361 CT examinations from 3,473 patients across four institutional cohorts and five public benchmarks. CAP-DIR increased internal-test organ-at-risk-region normalized cross-correlation from 84.76% to 96.92% relative to the strongest learning-based comparator, with low deformation folding, and remained superior across seven external cohorts. In a blinded review of 20 longitudinal cases, clinically acceptable contours increased from 45.0% to 82.5% for clinical target volumes and from 22.5% to 62.5% for organs at risk, while estimated editing time decreased. In a controlled benchmark, CAP-DIR reduced global dose-mapping error by 34.5% relative to the strongest comparator. These findings show that clinically informed, longitudinal registration can improve contour usability and dose mapping for adaptive radiotherapy.

0.37

Parameter-Efficient pretrained-CT-to-MRI Transfer for Rectal Cancer Segmentation: Performance-Calibration Trade-offs

cs.CV ·2026-08-27 ·Aneesh Rangnekar, Jorge Tapias Gomez, Joseph O Deasy, Harini Veeraraghavan
published similarity 0.65
Abstract · Accepted to the Medical Image AI in Radiation Therapy (MIART) Workshop at MICCAI 2026

Accurate rectal cancer segmentation from magnetic resonance imaging (MRI) is essential for adaptive radiotherapy and tumor response assessment, but deployment also requires computational efficiency and informative, calibrated uncertainty estimates. We therefore introduce SWIFT, a SWin pretrained model wIth parameter-eFficient and Tumor-aware fine-tuning for rectal cancer segmentation. A Swin V2 encoder pretrained on 10,444 public 3D CT volumes using a DINOv2-style objective was adapted to T2-weighted MRI through four cumulative configurations: full fine-tuning (SWIFT), decoder compression (SWIFTe), low-rank adaptation (SWIFTe-LoRA), and a four-member LoRA-decoder ensemble (SWIFTe-LDE4). Geometric accuracy, tumor detection, radiomic agreement, and probability calibration were evaluated on a held-out 247-case test set from a single-institution cohort acquired using 1.5 or 3 Tesla GE scanners. Compared with SWIFT, SWIFTe reduced total parameters by 70.1% (from 72.8M to 21.8M) and increased tumor detection rate from 89.9% to 93.9%, while achieving a slightly lower median surface DSC (0.61 versus 0.62) and improved radiomic agreement. In a separate SWIFTe ablation, removing tumor-aware augmentation reduced detection from 93.9% to 89.9% but increased surface DSC from 0.61 to 0.64, demonstrating a detection-boundary-agreement trade-off. SWIFTe-LoRA used 14.6% of SWIFTe's trainable parameters while retaining similar segmentation performance. SWIFTe-LDE4 achieved the lowest calibration errors among the four configurations after temperature scaling (expected calibration error, 0.217; Brier score, 0.222), although the absolute expected calibration error indicates residual miscalibration. Similar efficiency-calibration patterns were observed using the public VoCo checkpoint, supporting robustness across pretrained initializations rather than external clinical generalizability.

0.41

LUMINR: Intensity-conditioned Meta-learned INRs for Accelerated Medical Image Registration

eess.IV cs.CV ·2026-10-16 ·Damian Rynczak, Marek Wodzinski
hot direction similarity 0.64
Abstract · 13 pages, 7 figures, 3 tables

Implicit neural representations (INRs) have been applied to deformable image registration, where a lightweight network maps a spatial coordinate to a deformation vector. Because an INR encodes one specific signal in its parameters, a fresh network must be optimized for every image pair at test time, which is slow. Existing methods reduce this cost by meta-learning an initialization across a population of image pairs, and condition the weights of the INR globally, so the same conditioning applies at every coordinate while the deformation field it initializes varies across the domain. We propose LUMINR, a meta-learning framework that accelerates this per-pair fitting and in which the conditioning is local instead. LUMINR uses an INR that maps a coordinate, together with local intensity and gradient features, to a deformation vector, so the conditioning varies over the domain at the resolution of the field being modelled. Its objective is to find an initialization of the INR parameters from which the network can be fine-tuned to register any unseen pair in only a few optimization iterations. We evaluate LUMINR on 3D deformable registration of brain MRI from the OASIS dataset, where local conditioning and the meta-learned initialization prove complementary: early in fitting they reach a markedly higher accuracy than either does alone. Fine-tuned from that initialization, LUMINR matches the accuracy of the same conditioned INR fit from scratch in roughly a tenth of the gradient steps and a tenth of the wall-clock time, while the deformation fields stay smooth with negligible folding.

0.50

Anatomy-Change-Aware Bidirectional Selective State-Space Memory for Clinically Deployed Thoracic Radiotherapy Auto-Contouring

eess.IV cs.CV ·2026-09-11 ·Galib Ahmed, Istiak Ahmed, Aritra Islam Saswato, Asib Mostakim Fony, Kazi Shahriar Sanjid +13 more
similarity 0.63
Abstract

We developed DAMM-Net++, a 2.5D architecture for thoracic OAR and target volume segmentation that addresses three persistent challenges in radiotherapy auto-contouring: inter-slice surface incoherence, systematic failure on small low-contrast targets, and the absence of per-case reliability signals. The central component is an anatomy-change-aware bidirectional selective state-space memory that models through-plane anatomical change and selectively propagates context along the axial slice sequence. A boundary-aware decoder sharpens near-surface predictions, and an uncertainty head provides calibrated per-voxel confidence for clinical triage. We evaluated 2,146 patients across four centers, an independent external cohort of 112 patients, and a multicenter reader study involving 17 radiation oncologists on 305 cases. The model achieves a mean Dice of 0.955 and HD95 of 3.78 mm, with the largest gains on low-contrast organs-at-risk (OARs) and target volumes where through-plane context is most critical. The uncertainty head is well-calibrated and supports case-level triage. In the reader study, AI assistance reduced contouring time by 75-80% across experience levels and raised junior-reader IoU from 0.861 to 0.925, matching the unedited model. External validation showed a modest internal-to-external drop (< 5%) with calibrated uncertainty transferring without recalibration. The complete deployment pipeline from DICOM ingestion to TPS-compatible RTSTRUCT export has been integrated into the clinical workflow at a partner hospital, where it is used to assist with contouring. These results suggest that anatomically motivated inter-slice memory, paired with uncertainty-guided review, offers a clinically viable path for thoracic auto-contouring.

0.20

GliomaINK: A Tumor and Anatomy Conditioned Flow Matching Framework for 3D MRI Sequence Synthesis in Glioma Patients

eess.IV cs.CVq-bio.TO ·2026-10-16 ·Moinak Bhattacharya, Annie Singh, Mohammad Chaudhry, Prateek Prasanna, Gagandeep Singh
similarity 0.63
Abstract

Background: Incomplete multiparametric MR examinations limit glioma characterization and downstream AI tools. Generative models can synthesize missing MRI sequences, but anatomical structure and clinically relevant tumor features are challenging to preserve. We propose GliomaINK, an anatomy-guided conditional flow matching framework for cross-sequence 3D brain MRI synthesis. Methods: A 3D SwinUNETR predicted the conditional velocity field while an auxiliary topology-preserving loss encouraged structural consistency. The model was trained on 1,083 patients from the BraTS-AG dataset and independently tested on an in-house clinical cohort. Downstream tasks include image quality, tumor segmentation, IDH1 mutation-status prediction, and overall survival prediction. Two radiologists independently evaluated the anatomical fidelity, pathological representation, and overall image quality of the synthesized images. Results: GliomaINK exhibited the highest PSNR across all six MRI translation directions in both evaluation cohorts. In the BraTS-AG test set, the PSNR reached $25.64\pm0.55$ dB for the T2W-to-T1C synthesis, compared with $13.78\pm0.32$ dB for Pix2Pix and $18.90\pm0.53$ dB for SPADE. For downstream tumor segmentation, the method showed strong performance across tumor subregions with Dice scores reaching $0.928\pm0.014$ for edema, and $0.885\pm0.040$ for enhancing tumor. For the IDH1 mutation-status prediction, GliomaINK achieved the highest AUROC score in four of the six sequence configurations, reaching $0.827\pm0.088$. Conclusion: Anatomy-guided conditional flow matching enables high-fidelity cross-sequence glioma MRI synthesis demonstrating potential for preservation of clinically relevant information in synthesized MRI and improving downstream tasks.

0.18

From Vision to Context: A Review of Prompt-Driven Target Volume Segmentation in Radiotherapy

eess.IV ·2026-11-04 ·Bakpen Kombat, Guus Grimbergen, Maarten L. Terpstra, Gert J. Meijer, Lois +1 more
survey similarity 0.63
Abstract · Submitted to Computerized Medical Imaging and Graphics

Accurate target volume (TV) segmentation is essential for radiotherapy (RT) planning but remains time-consuming. Moreover, the final contour depends on the expertise of the radiation oncologist. Although deep learning has improved medical image segmentation, image-only models cannot encode the clinical reasoning that governs TV delineation, particularly for the clinical target volume (CTV), where boundaries are defined by clinical knowledge rather than imaging features alone. Prompt-driven segmentation has recently emerged as a strategy to address this limitation. This work aims to review these approaches for RT TV segmentation with four objectives: (1) compare the different prompting techniques used; (2) compare their performance against image-only baselines; (3) assess how they are evaluated against standard metrics, including the Dice similarity coefficient (DSC), 95th Hausdorff distance, sensitivity, precision, and clinical assessment; and (4) identify the gaps needed for clinical translation. We systematically searched PubMed, Embase, and arXiv for studies incorporating geometric, clinical text, or interactive prompts into deep learning models for RT TV delineation. Thirteen studies met the inclusion criteria, spanning head and neck, breast, prostate, lung, cervix, and rectal cancers. Seven studies used clinical text prompting, four used geometric prompting, and two used interactive prompting; three combined modalities. Reported DSC ranged from 0.67 to 0.93, compared to 0.65 to 0.91 for image-only baselines. None reported sensitivity or precision. Clinical text prompting appears well suited to CTV delineation. Evidence remains limited, and standardized prompt engineering and clinical validation are needed before these approaches can be translated into routine RT practice.

0.23

Resampling-based batch reweighting for ComBat harmonization of MRI radiomic features in a multi-scanner glioma cohort

eess.IV physics.med-ph ·2026-11-01 ·Rifa Sajda Tasnim, Yushuf Sharker, Md Forhad Hossain, Rakibur Rahman, Enamul Hoque Bhuiyan
published similarity 0.63
Abstract · Original article. Submitted to Journal of Magnetic Resonance Imaging (JMRI)

Radiomic features derived from magnetic resonance imaging (MRI) are sensitive to scanners; therefore, they require harmonization across scanners. In a radiomic feature dataset, some batches may be severely underrepresented compared to the others e.g., the Erasmus Glioma Database, which may provide harmonized features biased towards the larger batches in the dataset. We investigated whether reweighting underrepresented scanner batches before empirical-Bayes ComBat estimation improves feature harmonization and reduces residual scanner association while retaining grade-related information. In this retrospective, the Erasmus Glioma Database included 733 eligible patients acquired at a single center across nine vendor-by-field-strength configurations. Structural MRI acquired at 1 T, 1.5 T, and 3 T; four structural MRI sequences were analyzed. From four structural MRI sequences, 428 features were computed using an IBSI-compliant PyRadiomics implementation. The sample sizes of some scanner batches were very small compared to others, which may produce unequal precision and shrinkage of batch-effect estimates. We proposed a data augmentation approach to overcome the limitation of ComBat. We provided exploratory evidence, along with confirmatory Kruskal-Wallis tests with a Benjamini-Hochberg correction to assess the proposed method. Before harmonization, 392/428 features (91.6%) differed significantly across scanner batches (median eta-squared=0.463). Standard ComBat reduced this to 13/428 (3.0%), whereas batch-augmented ComBat reduced it to 8/428 (1.9%); the median residual effect size was <0.001 for both harmonized conditions. Batch augmentation appeared to be a useful strategy to improve the performance of ComBat for feature harmonization under severe batch-size imbalance.

0.32

LeCor: Learning to Be Corrected by Meta-Learned Test-Time Training for Interactive 3D Lung-Tumour Segmentation

cs.CV cs.LG ·2026-09-08 ·Yi Luo, Yike Guo, Wenxuan Li, Zongwei Zhou, Rui Zhang +1 more
similarity 0.61
Abstract · 18 pages, 4 figures

Delineating lung tumours on computed tomography (CT) takes a considerable share of the time spent on radiotherapy planning, and a contour proposed by a model can be refined interactively by the clinician. Promptable foundation models such as SAM 3 support this workflow by writing each correction into a session memory that conditions the remaining slices, while the model weights stay fixed. On 690 test cases from five public CT cohorts, fine-tuning SAM 3 on lung tumours raises the Dice obtained from a single point prompt from 0.298 to 0.757, and seven rounds of corrections raise it further to 0.765, but under memory conditioning alone the accuracy on slices the annotator has not touched stops improving after six rounds. We therefore treat each correction as a training signal and propose LeCor, which performs test-time training on a small set of case adapters that are reset for every case and meta-learned such that a single gradient step driven by a click improves the slices that were not clicked. On the 133 test cases that span at least eight slices, LeCor raises the Dice reached after seven correction rounds from 0.787 with the fine-tuned model to 0.827, reduces the number of cases that never reach a Dice of 0.80 from 47 to 27, and reaches in three correction rounds the accuracy that the fine-tuned model attains in seven.

0.21