CS Paper Radar

Resampling-based batch reweighting for ComBat harmonization of MRI radiomic features in a multi-scanner glioma cohort

Rifa Sajda Tasnim, Yushuf Sharker, Md Forhad Hossain, Rakibur Rahman, Enamul Hoque Bhuiyan

eess.IV physics.med-ph ·submitted 2026-11-01 19:43 UTC · v2
published

Abstract

Radiomic features derived from magnetic resonance imaging (MRI) are sensitive to scanners; therefore, they require harmonization across scanners. In a radiomic feature dataset, some batches may be severely underrepresented compared to the others e.g., the Erasmus Glioma Database, which may provide harmonized features biased towards the larger batches in the dataset. We investigated whether reweighting underrepresented scanner batches before empirical-Bayes ComBat estimation improves feature harmonization and reduces residual scanner association while retaining grade-related information. In this retrospective, the Erasmus Glioma Database included 733 eligible patients acquired at a single center across nine vendor-by-field-strength configurations. Structural MRI acquired at 1 T, 1.5 T, and 3 T; four structural MRI sequences were analyzed. From four structural MRI sequences, 428 features were computed using an IBSI-compliant PyRadiomics implementation. The sample sizes of some scanner batches were very small compared to others, which may produce unequal precision and shrinkage of batch-effect estimates. We proposed a data augmentation approach to overcome the limitation of ComBat. We provided exploratory evidence, along with confirmatory Kruskal-Wallis tests with a Benjamini-Hochberg correction to assess the proposed method. Before harmonization, 392/428 features (91.6%) differed significantly across scanner batches (median eta-squared=0.463). Standard ComBat reduced this to 13/428 (3.0%), whereas batch-augmented ComBat reduced it to 8/428 (1.9%); the median residual effect size was <0.001 for both harmonized conditions. Batch augmentation appeared to be a useful strategy to improve the performance of ComBat for feature harmonization under severe batch-size imbalance.

Comment
Original article. Submitted to Journal of Magnetic Resonance Imaging (JMRI)
Journal ref
55e56c54-8774-4c97-bd43-1f7b8ac9dd2b. Journal of Magnetic Resonance Imaging (JMRI), 2026

Closest papers

Nearest neighbours by meaning across the whole index.

How Robust Are Prognostic Radiomic Features? Comparing Selection Techniques on Pooled Glioblastoma Cohorts

cs.CV cs.AIq-bio.QM ·2026-10-19 ·Yannick Sodonougbo, Marlene Schnieders, Alexia Rizoudis, Santiago Cepeda, Frank Kramer +1 more
similarity 0.66
Abstract · 7 pages, 1 figure

Radiomic survival studies in glioblastoma report heterogeneous prognostic features, but how much of this stems from the methodology itself is rarely examined. We analysed the association of 463 radiomic, anatomical and clinical features from pre-treatment MRI with overall survival in 705 IDH-wildtype glioblastoma patients from three public cohorts, using three techniques: a log-rank test after median split, univariate Cox regression (both Benjamini-Hochberg corrected) and an XGBoost regressor interpreted with SHAP. The log-rank test selected 99 features, Cox regression 72 and SHAP its top 20; five were selected by all three: age, a peritumoural T2 texture feature, the number of connected peritumoural mask components and two image-level intensity maxima. The two survival tests shared 51 features, about half of the SHAP top 20 were also selected by either test, and where selections overlapped, effect directions agreed. Many selections were PyRadiomics diagnostic descriptors that are not restricted to tumour voxels. Analytical pipeline choices, including ranking method, pre-filtering and descriptor handling, can substantially influence which features appear prognostic.

0.24

GliomaINK: A Tumor and Anatomy Conditioned Flow Matching Framework for 3D MRI Sequence Synthesis in Glioma Patients

eess.IV cs.CVq-bio.TO ·2026-10-16 ·Moinak Bhattacharya, Annie Singh, Mohammad Chaudhry, Prateek Prasanna, Gagandeep Singh
similarity 0.65
Abstract

Background: Incomplete multiparametric MR examinations limit glioma characterization and downstream AI tools. Generative models can synthesize missing MRI sequences, but anatomical structure and clinically relevant tumor features are challenging to preserve. We propose GliomaINK, an anatomy-guided conditional flow matching framework for cross-sequence 3D brain MRI synthesis. Methods: A 3D SwinUNETR predicted the conditional velocity field while an auxiliary topology-preserving loss encouraged structural consistency. The model was trained on 1,083 patients from the BraTS-AG dataset and independently tested on an in-house clinical cohort. Downstream tasks include image quality, tumor segmentation, IDH1 mutation-status prediction, and overall survival prediction. Two radiologists independently evaluated the anatomical fidelity, pathological representation, and overall image quality of the synthesized images. Results: GliomaINK exhibited the highest PSNR across all six MRI translation directions in both evaluation cohorts. In the BraTS-AG test set, the PSNR reached $25.64\pm0.55$ dB for the T2W-to-T1C synthesis, compared with $13.78\pm0.32$ dB for Pix2Pix and $18.90\pm0.53$ dB for SPADE. For downstream tumor segmentation, the method showed strong performance across tumor subregions with Dice scores reaching $0.928\pm0.014$ for edema, and $0.885\pm0.040$ for enhancing tumor. For the IDH1 mutation-status prediction, GliomaINK achieved the highest AUROC score in four of the six sequence configurations, reaching $0.827\pm0.088$. Conclusion: Anatomy-guided conditional flow matching enables high-fidelity cross-sequence glioma MRI synthesis demonstrating potential for preservation of clinically relevant information in synthesized MRI and improving downstream tasks.

0.18

ViBMR: A Large-Scale Multi-Sequence Brain MRI Dataset and Comprehensive Evaluation for Vietnamese Radiology Report Generation

cs.CV ·2026-10-21 ·Dai Lam Le, Minh Khoi Nguyen, Son Dinh Nguyen, Amir Reza Jafari, Viet Ha +4 more
published similarity 0.64
Abstract · Accepted at IEEE/CVF Winter Conference on Applications of Computer Vision (WACV 2027)

Automated radiology report generation for multi-sequence brain MRI holds strong promise for alleviating radiologists' workload, yet it remains a demanding problem: brain MRI studies are inherently volumetric, each pulse sequence carries complementary diagnostic information, and annotated data are critically scarce for low-resource clinical languages. Existing brain MRI-report resources are still dominated by English reports, translated clinical text, or datasets adapted from task-specific imaging benchmarks, leaving routine low-resource clinical reporting and heterogeneous multi-sequence MRI protocols insufficiently represented. To bridge this gap, we introduce ViBMR, to the best of our knowledge, the first large-scale multi-sequence brain MRI dataset paired with routine Vietnamese clinical reports, comprising 3,649 patients and 11,875 MRI series across T1, T2, FLAIR, and contrast-enhanced T1 sequences. Building on ViBMR, we establish a comprehensive evaluation setup for brain MRI report generation, covering representative medical vision-language models, multi-sequence inputs, and feature aggregation strategies. The results provide key insights into dataset characteristics and model behavior, while demonstrating the necessity of native low-resource clinical datasets for reliable Vietnamese-origin brain MRI report generation. Our dataset and baseline models will be released for non-commercial research.

0.34

Is Deformable Image Registration Ready for Brain Metastasis Reirradiation Dose Accumulation? A Longitudinal MRI Benchmark of Registration Accuracy

eess.IV cs.CV ·2026-08-27 ·Hengjie Liu, Manju Sharma, Xinyi Fu, Di Xu, Ke Sheng
benchmark similarity 0.63
Abstract

Dose accumulation is increasingly important in adaptive radiation therapy and reirradiation, but its clinical validity depends on the performance of deformable image registration (DIR). Reirradiation of brain metastases (BMs) with stereotactic radiosurgery (SRS) provides a controlled but clinically meaningful DIR test case: intra-subject brain deformation is usually limited after rigid alignment, yet recurrent lesions can undergo substantial local shape and volume changes that rigid registration cannot capture and can affect dose accumulation. We benchmarked a wide range of learning-based and optimization-based DIR methods on 87 manually screened longitudinal contrast-enhanced T1-weighted MRI lesion pairs from an institutional BM SRS retreatment cohort. Learning-based methods pretrained on healthy-brain MRI were evaluated zero-shot and after instance-specific optimization (ISO) or tumor-proximity target-specific optimization (TSO). Registration was assessed using lesion overlap (Dice), surface distance metrics (HD95 and sASD), target-volume recovery, and runtime and memory. Pretrained learning-based methods showed variable zero-shot performance, while ISO/TSO improved all tested learning-based families. However, optimization-based methods remained the best-performing approach while maintaining reasonable runtime. These findings suggest that even state-of-the-art DIR methods do not yet provide sufficiently accurate and consistent registration for unmonitored use in brain metastasis reirradiation dose accumulation. Because accurate registration is a prerequisite for deformable dose accumulation, clinical application will require case-level quality control and direct assessment of how registration uncertainty affects downstream dose metrics.

0.21

Evidence-Bound Reasoning: Neuro-Semantic Verification of Biomedical AI in Glioblastoma Radiogenomics

cs.CL ·2026-10-06 ·Mariya Miteva, Maria Nisheva-Pavlova
benchmark similarity 0.63
Abstract · 15 pages, 4 figures, 4 tables. Preprint

Background: Biomedical AI can generate plausible explanations without reliably verifying whether each statement is supported by patient-specific evidence. We developed a neuro-semantic verification framework that converts radiomic measurements into addressable evidence records and machine-checkable claims. Methods: UPenn-GBM radiomics were aligned with de novo CaPTk extraction from standardized MRI and expert-validated segmentations in an independent multicenter cohort. The shared space comprised 1,728 features from T1, T1GD, T2, and FLAIR MRI across three tumor regions. Reference-defined semantic states were derived from 611 UPenn cases. We evaluated cross-cohort transportability, model-linked provenance, deterministic verification, controlled predictive degradation, and an LLM claim-extraction pilot; MGMT prediction served only as a transport stress test. Results: Median semantic-state agreement was 0.786 (weighted kappa 0.709), ranging from 0.918 for morphologic to 0.252 for intensity features. The external evidence ledger contained 1,655 model-linked records for 331 patients. The verifier achieved 100% exact-set accuracy in a 6,620-claim corruption benchmark. In a 24-case pilot, GPT-5.6 Sol reproduced 72/72 prespecified atomic claims, and the frozen verifier recovered 24/24 expected conditions. During controlled degradation, ROC AUC declined from 0.899 to 0.500 while verification accuracy remained 1.000. External MGMT discrimination was weak (ROC AUC 0.543). Conclusions: Verifiability can be engineered and evaluated independently of predictive performance. LLMs may structure explanations, while final evidence-consistency checking remains deterministic.

0.23

M3-Score: Fidelity, Memorization and Coverage as Separate Axes for Evaluating Generative Radiology Image Models

cs.CV ·2026-09-27 ·Sathiyamohan Nishankar, Pubudu Sanjeewani, Asanka Perera
similarity 0.62
Abstract

Quantitative evaluation of generative models for radiology remains challenging. Clinically relevant structures are often small and infrequent, feature spaces learned from natural images may represent them poorly, and a single summary score cannot distinguish limited fidelity from limited diversity. This study proposes the Medical Multi-axis Maximum Mean Discrepancy score (M3-Score), an evaluation framework based on RadioDINO-s16, a frozen vision transformer pretrained on radiology images. M3-Score reports three complementary axes computed at pre-specified encoder depths: \emph{fidelity}, measured by an unbiased multi-bandwidth radial basis function (RBF) MMD$^2$ at the final block; \emph{memorization}, measured by nearest-neighbor distances at 75\% depth; and \emph{coverage}, defined as the fraction of real images with a generated neighbor within their $k$-nearest-neighbor radius at 33\% depth. Reference sets are sampled across subjects to limit the influence of correlated slices. On BraTS brain MRI, the fidelity axis ordered five comparison sets of increasing severity (Spearman $ρ= 1.00$), and a subject-disjoint real set yielded $\mathrm{MMD}^2 = 0$ (permutation $p = 1$). An unconditional denoising diffusion probabilistic model achieved $\mathrm{MMD}^2 = 0.073$ (95\% confidence interval $[0.071, 0.080]$) but covered only 38\% of the real distribution. Under progressive mode dropping, $k$-NN manifold recall increased at all twelve encoder blocks, whereas the proposed coverage estimator decreased monotonically ($ρ= -1.00$). RadioDINO-s16 features separated real brain MRI from generated samples with a ROC-AUC of 0.819, compared with 0.555 for InceptionV3 and 0.582 for CLIP. Across a twentyfold range of sample sizes, the mean M3 value varied by a factor of 1.05, compared with 2.52 for the Fréchet Inception Distance.

0.21

The Diagnosis a Reporter Leaves Unspoken: Surfacing Frozen Tumor Features for Brain-Tumor MRI Reporting

cs.CV ·2026-09-02 ·Khawaja Murad ul Hassan, Ruqiyya Adil, Adil Qayyum, Rida Hassan, Asad Mansoor Khan +2 more
published similarity 0.62
Abstract · 10 pages, 2 figures, 3 tables. Accepted at MLCN 2026, a workshop held in conjunction with MICCAI 2026; to appear in Springer LNCS

A capable brain-MRI report generator can still be, in effect, diagnostically silent. When a multi-chain chain-of-thought (CoT) reporter built on a medical Mistral-7B backbone is evaluated on held-out cohorts, it names most meningiomas and almost all metastases "glioma" (diagnosis recall 0.44/0.07). Yet the answer is not absent from the model: a supervised linear probe applied to its frozen segmentation features recovers the three tumour cohorts at 0.82 macro-F$_1$ (5-fold cross-validation; chance $\approx$0.33). We introduce NeuroFusion, an assistive reporter that surfaces this latent signal rather than overriding it: discriminative field-classifier heads over per-lesion features condition a fast, single-pass draft-then-review decoder on their committed outputs. Built on the identical Mistral backbone, this restores the diagnosis (meningioma 0.92, metastasis 0.75) and wins 8 of 9 prose-content comparisons across three held-out cohorts (RaTEScore, RadGraph-F$_1$, GREEN; Holm-corrected paired BCa), with no significant loss on the ninth, at 5-6x lower latency ($\approx$80 vs. 457 s/case). A controlled negative result sharpens the mechanism: a learned diagnosis pin that overrides the decoder instead of merely informing it collapses out-of-distribution metastasis recall to 0.03. Grammar-constrained decoding keeps 92.3% of records schema-valid, making every sentence entailment-checkable (7.5% contradicted vs. 36.8% for the direct baseline). In a blinded nine-case pilot, two board-certified neurologists independently rated NeuroFusion highest in every tumour type, the only system with zero critical errors, and gave it the top-rated sign-off in eight of nine cases (six outright, two ties).

0.46

A Tumour-Aware Multimodal Framework for Explainable Prediction of IDH Mutation in Gliomas from Multi-Sequence MRI

eess.IV cs.CV ·2026-11-13 ·Tahsien Al-Quraishi, Waseem Alwan Zaboon, O. S. Albahri, Raza Nowrozy
similarity 0.62
Abstract · 45 pages, 12 figures, 4 tables. Preprint of an article submitted for consideration in International Journal of Information Technology & Deci…

Accurate prediction of isocitrate dehydrogenase (IDH) mutation status is essential for glioma diagnosis, prognosis, and treatment planning. Although recent deep learning approaches have demonstrated promising performance, many rely on whole-brain feature extraction and provide limited interpretability. This study proposes a tumour-aware multimodal framework for explainable, non-invasive prediction of IDH mutation status from multiparametric magnetic resonance imaging (MRI). The proposed framework integrates four MRI sequences (T1, T1CE, T2, and FLAIR), tumour subregion segmentation, quantitative radiomic descriptors, and clinical information within a unified deep learning architecture. An ablation study was conducted to evaluate the contribution of tumour-aware learning, radiomic features, and clinical variables. Model performance was assessed using multiple complementary evaluation metrics, including accuracy, precision, recall, F1-score, balanced accuracy, receiver operating characteristic analysis, confusion matrix evaluation, and Grad-CAM visualisation. Experimental results demonstrated that the proposed multimodal framework consistently outperformed the baseline MRI-only model, with the Clinical Fusion model achieving the strongest overall predictive performance. The integration of tumour-aware learning, radiomic descriptors, and clinical information progressively improved classification performance, while Grad-CAM visualisations indicated that the model predominantly focused on biologically relevant tumour regions. These findings suggest that tumour-aware multimodal feature integration enables accurate, interpretable, and non-invasive molecular profiling of gliomas and provides a promising foundation for future clinical decision support in precision neuro-oncology.

0.12