CS Paper Radar

Sensor Diagnosis for Fuel and Emissions Monitoring in Heavy-Duty Diesel Vehicles

Tejas Dahiya, Saurabh Kumar Gupta

cs.LG eess.SY ·submitted 2026-10-15 03:46 UTC · v1
published

Abstract

Faulty sensor readings can distort estimates of fuel use and carbon dioxide emissions from diesel engines. We evaluate two procedures that use relationships learned from healthy measurements to diagnose faults and guide fuel correction. The diagnosis procedure tests whether replacing a suspected faulty reading with an estimated healthy value helps a model predict another sensor's recorded reading more accurately. It then predicts the fault type and decides whether to report the diagnosis. We evaluate five synthetic fault types on 217 steady-state operating points from a heavy-duty diesel engine, excluding all measurements at selected engine speeds from training. Across 31,500 fault-injected groups of 20 operating points, it issues diagnoses for 77.3% of groups, with 92.1% of diagnoses issued on these groups correct. The fuel correction procedure uses a different sensor-selection rule at individual operating points, testing how each replacement changes the largest prediction error across all six sensors. Fuel correction requires a fault alarm and engine speed and torque close to the training conditions. A fuel reading is replaced only when its replacement reduces the largest prediction error sufficiently more than replacements for the other sensors. Assuming faults in 1% of one-hour scenarios, equally likely sensors and fault types, and equal time at each measured condition, selected fuel corrections reduce mean absolute error in calculated combustion CO2 by 83.8%. On this engine map, learned relationships support complete sensor diagnoses and fuel corrections that improve emissions accounting while preserving unaffected readings.

Comment
Accepted at the Tackling Climate Change with Machine Learning workshop at NeurIPS 2026

Closest papers

Nearest neighbours by meaning across the whole index.

LLM Ensemble Fault Classification for Automotive HiL Validation

cs.SE ·2026-08-11 ·Hamza Ouarrad, Mohammad Abboush, Andreas Rausch
top venue similarity 0.63
Abstract · 8 pages, 3 figures. Accepted at the 23rd Workshop on Model Driven Engineering, Verification and Validation (MoDeVVa 2026), co-located with M…

Automotive HiL validation generates large multivariate test recordings whose analysis remains challenging due to manual review effort, rule-based limitations, and the need for explainable diagnostic decisions. Recent machine-learning and deep-learning approaches have improved fault diagnosis, but they often require large labelled datasets, generalise poorly across operating conditions, and provide limited insight into their predictions. This paper proposes an explainable multi-LLM ensemble framework for sensor-level fault classification in automotive validation. The framework uses compact evidence representations of fault-injection recordings and combines the outputs of heterogeneous large language models to improve diagnostic robustness, ranking quality, confidence reliability, and interpretability. The approach is evaluated on gasoline-engine and electric-vehicle HiL systems across three driving settings and ten single-fault classes. Among the individual models, Mistral Small~24B provides the strongest overall single-model trade-off, achieving 0.903 Top-1 accuracy, 0.887 MCC, and the lowest Brier score of 0.102. The final Top-3 ensemble combines Mistral Small~24B, Qwen2.5~32B, and Phi-4~14B using confidence-weighted voting, improving the scenario-averaged results to 0.917 Top-1 accuracy, 0.913 macro F1, and 0.902 MCC, while also providing the best calibration among the tested ensemble strategies. A Top-5 ensemble does not improve over the Top-3 configuration, indicating that model complementarity is more important than ensemble size. The results show that coordinated multi-LLM reasoning can support robust, calibrated, and engineer-interpretable fault classification for automotive HiL validation.

0.35

Agentic4PDM: Host-Governed Evidence Admissibility for Industrial Fault Diagnosis

cs.AI cs.LG ·2026-10-13 ·Nam V. Nguyen, Hoang Van Truong, Hieu D. D., Duy Khuong Nguyen, Quang Pham +1 more
hot direction similarity 0.56
Abstract · 67 pages, 12 figures, including appendices

We study industrial fault diagnosis as a classification task that assigns sensor time-series windows to predefined health states or fault types. Scarce labels and changing operating conditions make repeated training of specialized classifiers costly. Yet structures such as periodicity, trends, and transients can remain diagnostically informative and be examined through reusable analytical tools. LLM agents can select and interpret these tools, but fixed rules or training-derived guidance may not resolve each signal's ambiguity, while unconstrained interpretation may overstate weak or conflicting results. We introduce Agentic4PDM, a framework that separates adaptive investigation from control over evidence use. LLM agents compare each signal with labeled references from every candidate class, identify unresolved distinctions, and propose follow-up measurements. A deterministic software controller, called the host, enforces contract-checked gated adjudication (CCGA): it checks requests, requires commitment to a complete tool batch before results are observed, and assigns evidence roles based on tool checks against labeled references. These roles distinguish corroborative support from advisory information. The Judge Agent proposes a diagnosis, while the controller checks protocol compliance and records the investigation. Agentic4PDM supports training-free diagnosis using pretrained representations and labeled references without task-specific diagnostic models, and a standard setting that additionally investigates trained-model predictions. Experiments on selected bearing and motor diagnosis challenges and an unfiltered industrial test set supplied by our customer show gains in aggregate macro F1 over the evaluated diagnostic and agentic baselines. Ablations further support the value of the governed workflow.

0.32

When More Modalities Hurt: Modality Dropout for Heavy-Duty Vehicle Engine Diagnostics

cs.LG ·2026-08-24 ·Adeel Zafar, Slawomir Nowaczyk, Hamid Sarmadi, Saeed Gholami Shahbandi
similarity 0.55
Abstract

Heavy-duty vehicle diagnostics generate three disconnected data modalities: unstructured multi- lingual service complaints, high-dimensional sensor telemetry with over 80% missing values, and Diagnostic Trouble Codes (DTCs). We investigate whether fusing these modalities improves engine component classification on a proprietary dataset from a major truck manufacturer. Through 5-fold cross-validation across multiple model configurations spanning three model families on five engine component classes (885 samples, the full cross-database matched population for this manufacturer), we find that naive fusion provides modest gains over text alone (65.3%). However, modality dropout during training, which randomly disables entire modalities per batch, forces the network to exploit weaker inputs and achieves 68.8% accuracy on text+DTC fusion (weighted F1: 0.67), a 3.5-point improvement over text-only (65.3%, weighted F1: 0.64) and the best result across all methods including logistic regression and gradient-boosted trees. Per-class analysis shows that the dominant modality varies by fault type: text describes symptoms, DTCs encode structured fault signals, and sensors measure physical state. On intake/exhaust faults, sensors alone reach 93% where text achieves 80%. On fuel system faults, fusion with modality dropout nearly triples accuracy from 15% to 38% over text alone. To our knowledge, this is the first application of three-way modality fusion combining text, sensors, and fault codes in industrial vehicle diagnostics.

0.12

Neutrosophic Ensemble Classification for Uncertainty-Aware Bearing Fault Detection: Evidence from Laboratory and Variable-Speed Industrial Benchmarks

cs.LG cs.AI ·2026-09-18 ·Maikel Leyva-Vazquez, Dayron Rumbaut Rangel, Lorenzo Cevallos-Torres, Alexis Matheu Perez
code/data similarity 0.55
Abstract · 18 pages, 5 figures

Machine learning classifiers for bearing fault detection produce scalar confidence scores that conflate confident errors with genuinely ambiguous predictions, and the conventional truth/falsity pair (F = 1 - T) is algebraically redundant by construction. We operationalize a refined neutrosophic decomposition of a Random Forest + XGBoost + Logistic Regression ensemble into four indicators -- T-hat (top-class evidence), F-hat (best-competitor evidence), predictive entropy I1-hat, and decision disagreement I2-hat -- evaluated on two bearing benchmarks (CWRU and JNU, 600-1000 rpm) under a leave-one-condition-out protocol. On CWRU, after correcting a file-to-class mapping error, the ensemble reaches 100.00 percent accuracy on three of four held-out loads (92.27 percent on the fourth), leaving too few errors for uncertainty analysis. On JNU, holding out 1000 rpm, accuracy collapses to 40.64 percent, below a majority-class baseline; Logistic Regression (57.91 percent) generalizes far better than the tree ensembles. I1-hat shows a robust association with error beyond T-hat/F-hat, while I2-hat contributes little; standalone Logistic Regression confidence outperforms the full decomposition, a boundary condition we report honestly. Two further results extend this: fusing a time-domain and a frequency-domain model of the same signal and scoring their Jensen-Shannon divergence beats that model own entropy (AURC 0.29 vs. 0.36 on the standard split; 0.54 vs. 0.73 under a harder single-condition reproduction), the only indicator moving correctly under a CWRU-versus-JNU distributional-shift contrast; and, on CWRU alone, literature-verified bearing fault frequencies, correctly demodulated via the envelope spectrum, separate most fault classes almost perfectly (99.57 percent) using three interpretable features. Code, logs, and figures are released for independent verification.

0.38

IPM-FM: A Foundation Model with Consensus Feature Selection for Industrial Process Monitoring

cs.LG cs.AI ·2026-09-08 ·Liang Cao, Weide Liu, Yan Qin, Jun Cheng, Weisi Lin +1 more
similarity 0.54
Abstract

Industrial process monitoring is fundamental to the safety and economic performance of modern process plants. Current practice remains a one-task-one-model paradigm that is label-inefficient and prone to degradation under operating drift. Foundation models have reshaped language, vision, and generic time-series forecasting, but it has not been adapted to industrial process monitoring. This setting poses domain-specific challenges, including safety-critical decisions and asymmetric sampling between process variables and laboratory measurements. We propose the industrial process monitoring foundation model (IPM-FM). It first learns general-purpose representations from unlabeled industrial process data through self-supervised pretraining, then adapts to specific monitoring tasks using a small amount of task-labeled data, and finally produces calibrated predictions through an uncertainty-aware prediction head. IPM-FM integrates a self-supervised Informer backbone with a multi-criteria consensus feature selector, a recursive lag-feature regression head, and a calibrated Monte Carlo dropout uncertainty module. On a seven-year hydrotreater dataset for diesel flash-point soft sensing, IPM-FM attains an RMSE of 2.99, $R^2$ of 0.50, and 97\% coverage of its 95\% predictive interval, outperforming the strongest classical and from-scratch sequence baselines by 8.3\% and 14.6\% in RMSE respectively, supporting the viability of a unified pretraining--adaptation framework for industrial process monitoring.

0.29

An Interpretable Fuzzy Tree for Turbofan Remaining Useful Life with an Auditable Per-Component Diagnostic Layer

cs.AI ·2026-11-08 ·Hugo Henry, Bharadwaj Dogga, Scott Philips, Kelly Cohen
similarity 0.54
Abstract · 16 pages, 3 figures, 3tables and 6 equations

Data-driven remaining useful life (RUL) estimators for turbofan engines are accurate but opaque, and their internal features typically encode remaining life rather than any specific component's state. This paper presents an interpretable genetic fuzzy tree that predicts RUL from cruise-condition sensor means on N-CMAPSS while exposing a per-component diagnostic layer inspectable rule by rule. The tree follows the engine hierarchy: sensors to component health, then to bounded component damage, spool damage, and RUL, so each level answers a different maintenance question. Training is staged so the prognostic objective cannot reshape the diagnostic layers: health leaves are fitted to physical targets and frozen, a deterministic fuzzy damage map with fleet-referenced thresholds is imposed on each component, and only the aggregation is optimized for RUL. It consumes 13 cruise-mean scalars per cycle rather than a trajectory, which removes any sequence model. On the native split it reaches 8.44 cycles RMSE on the multi-fault subset and 11.51 across all modes with 333 free parameters, 411 total rules, 32 to 12,000 times fewer than compiled baselines. An exhaustive sensor search bounds which components are diagnosable under the tested cruise-mean design, and the rule base is structured to admit formal verification, which this study does not discharge.

0.26

Can LLM Agents Efficiently Identify Appliance Faults? Insights From Diagnosing a Simulated Appliance

cs.CL ·2026-10-13 ·Lucas H. McCabe, Sarah Lukens, H. Howie Huang
benchmark similarity 0.53
Abstract

In so-called "Industry 4.0," integrated sensors, analytics tools, and other digital technologies supplement industrial workflows, potentiating enhanced visibility and automation. Prognostics and health management (PHM) and natural language processing (NLP) practitioners alike have explored the application of large language models (LLMs) to industrial asset management, but many prior works' focus on exam-like benchmarks has limited their assessment of LLMs' ability to automate practical operations. Herein, we introduce CoffeeBench, a fault diagnostics task for LLM agents, using a simulated appliance. The LLMs we evaluate struggle to consistently identify faults from the sensor information alone, but the best-performing ones can iteratively refine the fault-option space to eventually obtain a successful diagnosis. Our subsequent analyses, therefore, focus on: differentiating models by diagnostic efficiency (RQ1); examining the lagging performance of the three worst models (RQ2); and identifying viable heuristics for selective prediction (RQ3), including that initial diagnostic uncertainty and LLM-judged soundness of reasoning are high-signal predictors of diagnostic success. In addition to our benchmark results (Section 3.1), we provide practical insights for improving the performance of the open-weight models on CoffeeBench, such as by explicitly tracking episode state on their behalf to reduce timeouts (Section 3.2) or applying a deliberation loop to refine diagnostic hypotheses (Section 3.3).

0.24

TRACK: Tool-Augmented Reasoning over Time Series for Fault Diagnosis in Power Management System

cs.LG cs.AIcs.CLeess.SY ·2026-11-16 ·Erkan Bayram, Debanjan Ghosh, Li Zhu, Sambarta Dasgupta
benchmark similarity 0.53
Abstract

Fault diagnosis in power management systems running multiple loads relies on experts manually inspecting current and voltage waveforms, which fails to scale across deployed units. We present TRACK, which pairs a time series encoder with a Small Language Model to produce structured, physics-grounded diagnostic reports, calling tools for exact, verifiable calculations. It operates on-device, keeping proprietary sensor data local and avoiding expensive API calls. We introduce a rubric-based framework that evaluates these reports by scoring structure, signal fidelity, physics reasoning, diagnosis, and actionability through per-criterion verdicts. On a 15-class multi-load simulated benchmark, TRACK achieves over 95% fault-category accuracy and generalizes to out-of-distribution faults, whereas the best encoder-probing baseline reaches only 58% accuracy.

0.26