Abstract

We adapt the diffeomorphic coarse-to-fine LapIRN architecture for longitudinal whole-body PSMA PET/CT registration in the Learn2Reg 2026 PSMAReg challenge. The method combines affine pre-registration, multi-modal deformable registration, and test-time instance optimization. We further introduce PET biomarker preservation losses for metabolic tumor volume (MTV) and total lesion glycolysis (TLG), including Jacobian-based constraints, and a per-structure rigidity regularization for skeletal structures. The submitted configuration achieved 81.0% DSC and 6.17 mm HD95, with MTV and TLG errors of 3.3% and 3.3%, respectively, on our evaluation protocol. Code is available at https://github.com/koegl/psmareg.

Closest papers

Nearest neighbours by meaning across the whole index.

Registration is a Representation Problem: Solving Whole-Body PET/CT Registration

cs.CV cs.LG ·2026-10-13 ·Neel Dey, Adrian V. Dalca
publishedbenchmarkcode/data similarity 0.72
Abstract · Technical report. First place winning solution for the MICCAI Learn2Reg 2026 PSMAReg challenge. Code and volumetric visualizations are avail…

Raw image intensities are a poor surrogate for similarity across images in correspondence problems. Further, while auxiliary segmentation labels can provide semantic identification and improve matching, they can assign only coarse identities to fine-grained anatomy and often cover only a subset of structures, particularly in whole-body settings. We present an approach that instead establishes correspondence using complementary representations of anatomy and demonstrate its utility for longitudinal whole-body PET/CT registration in the Learn2Reg 2026 PSMAReg Challenge. We use our 3D foundation model, anatomix, to derive fine-grained, per-voxel semantic representations that are consistent across volumes and further employ off-the-shelf segmentation models to obtain coarse anatomical identities. Together, these representations drive a GPU-accelerated iterative registration solver (FireANTs) in a hybrid multistage framework: the first stage estimates alignment from dense multi-channel features, after which a second refines the deformation using both anatomix- and segmentation-based losses. Lastly, because registration should not introduce non-biological tumor volume changes across time, we develop lesion-specific, component-wise volume preservation schemes. Without any task-specific training, our system placed first on the PSMAReg Challenge leaderboard. Code and interactive visualizations are available at https://www.neeldey.com/reps-for-reg.

0.31

AdaptReg: Skip-level FiLM Adapter for Task-Specific Adaptation of a Frozen Registration Foundation Model

cs.CV cs.LG ·2026-11-19 ·Shuyue Shi, Rong Yuan, Lin Tian
code/data similarity 0.66
Abstract · 9 pages, 2 figures, 3 tables. Paper for the Learn2Reg 2026 PSMAReg challenge (PSMA-PET/CT longitudinal registration), 4th place among 16 tea…

Longitudinal PSMA-PET/CT registration is a key step in assessing treatment response in prostate cancer, and it requires more than generic alignment accuracy: the deformation must preserve lesion volume, so that measured changes in metabolic tumor volume (MTV) and total lesion glycolysis (TLG) reflect treatment response rather than registration artifacts. We propose AdaptReg, which adapts a frozen registration foundation model to such task-specific requirements through a lightweight trainable adapter branch with identity-preserving initialization. Keeping uniGradICON fully frozen, we apply FiLM-style per-voxel affine modulation ($γ$, $β$) to its decoder skip connections; the modulation is generated from anatomical semantic features of a frozen TotalSegmentator encoder and supervised by a lesion volume-preservation loss. On the official Codabench validation set (20 pairs), AdaptReg achieves DSC 0.7585, HD95 6.33 mm, MTV/TLG errors of 1.68%/2.11%, and 0.0022% non-diffeomorphic voxels, improving on the uniGradICON + instance optimization baseline by $+0.05$ DSC and reducing the MTV/TLG errors by 70.9%/67.7%. On the hidden official test set (160 pairs), AdaptReg achieves CT DSC 0.816, PET DSC 0.598, and MTV/TLG errors of 4.02%/3.46%, ranking fourth among 16 teams in the final PSMAReg evaluation. Code: https://github.com/shishuyue/AdaptReg

0.48

Geometry-anchored PET-aware multimodal pseudo-CT synthesis for whole-body attenuation correction: the BIC-MAC Challenge

cs.CV ·2026-08-19 ·Xuan Loc Nguyen, Hoang-Loc Cao, Truong Thanh Hung Nguyen, Phuc Ho, Phuc Truong Loc Nguyen +2 more
published similarity 0.65
Abstract · Challenge paper for the Big Cross-Modal Attenuation Correction (BIC-MAC) Challenge at MICCAI 2026

The BIC-MAC challenge targets whole-body pseudo-CT synthesis from NAC-PET, Dixon MRI, and a 2D topogram for CT-less PET attenuation correction. We propose GeoPACT, a geometry-anchored multimodal framework that uses NAC-PET as the spatial reference and incorporates topogram and MRI features through gated residual fusion. Absolute coordinates and whole-body conditioning support anatomically consistent patch-based prediction. Training combines attenuation-map supervision with a differentiable PET-response surrogate to reduce errors relevant to downstream PET reconstruction. Full-resolution pseudo-CT volumes are generated using sliding-window inference without requiring CT or PET labels at test time.

0.27

Anatomical and Physical Supervision for CT-less PET Attenuation Correction: BIC-MAC 2026 Challenge

cs.CV ·2026-08-16 ·Petros Chatzitoulousis, George K. Matsopoulos
similarity 0.64
Abstract · 6 pages, 1 table. Technical report for the BIC-MAC 2026 Challenge

This report describes our submission to the Big Cross-Modal Attenuation Correction (BIC-MAC) 2026 Challenge for CT-less PET attenuation correction through multimodal pseudo-CT synthesis. We build upon a standard nnU-Net architecture and combine anatomical and physical supervision to improve both pseudo-CT quality and downstream PET reconstruction. Anatomical supervision is introduced through a frozen TotalSegmentator feature extractor, anatomy-guided structural constraints and patch sampling, while physical supervision is achieved using a differentiable attenuation correction factor projection loss based on multi-angle attenuation projections. Furthermore, the network is initialized with pretrained weights obtained from training on the SynthRAD Challenge MR-to-CT dataset. Minimal architectural modifications are applied, while performance improvements are pursued across the nnU-Net pipeline, including preprocessing, plans, and supervision design, among other components. Our final submission demonstrates the effectiveness of combining anatomical supervision, attenuation physics, and efficient nnU-Net scaling for CT-less PET attenuation correction.

0.07

Personalising Deformable Image Registration with Clinical Context and Deformation History for Adaptive Radiotherapy

eess.IV cs.AI ·2026-10-13 ·Caiwen Jiang, Songlin Zhao, Yuzhen Ding, Jia Mi, Samir H. Patel +21 more
benchmark similarity 0.63
Abstract · 27 pages, 7 figures and 6 tables. The submission includes Supplementary Information

Adaptive radiotherapy must account for anatomical changes during treatment, but doing so depends on reliably mapping targets, organs at risk and dose across serial images. Existing registration methods treat each image pair independently, without using radiotherapy-specific context or the patient's preceding anatomical trajectory. We developed Clinical-context-Aware and Patient-adaptive Deformable Image Registration (CAP-DIR), integrating source contours, dose, clinical text and prior-registration features. We evaluated 16,361 CT examinations from 3,473 patients across four institutional cohorts and five public benchmarks. CAP-DIR increased internal-test organ-at-risk-region normalized cross-correlation from 84.76% to 96.92% relative to the strongest learning-based comparator, with low deformation folding, and remained superior across seven external cohorts. In a blinded review of 20 longitudinal cases, clinically acceptable contours increased from 45.0% to 82.5% for clinical target volumes and from 22.5% to 62.5% for organs at risk, while estimated editing time decreased. In a controlled benchmark, CAP-DIR reduced global dose-mapping error by 34.5% relative to the strongest comparator. These findings show that clinically informed, longitudinal registration can improve contour usability and dose mapping for adaptive radiotherapy.

0.37

The Right Prior for the Right Deformation: Rethinking Continuous Deformable Image Registration

cs.CV ·2026-08-17 ·Hengjie Liu, Chushu Shen, Dan Ruan, Ke Sheng
code/data similarity 0.63
Abstract

Deformable image registration models implicitly encode deformation priors through their parametrization and optimization. In this work, we conduct a validation study on continuous registration methods to examine how these implicit priors affect performance across different registration tasks. Classic B-Spline transformations impose locality, smoothness, and scale through their control-point structure, whereas recent INR-based methods impose different priors through neural parameterization and optimization. We compare INR-Dense (IDIR), which directly models a dense displacement field using a SIREN-based INR; INR-BSCP (SINR), which predicts B-Spline control points with an INR; D-BSCP, which directly optimizes single-scale B-Spline control points; and MR-D-BSCP, which adds a multiresolution coarse-to-fine scheme. Experiments on inter-subject brain MR registration (OASIS) and intra-subject exhale-to-inhale lung CT registration (DIR-LAB 4DCT) reveal different behavior across deformation regimes. On OASIS, where deformations are moderate but locally complex, D-BSCP matches or slightly outperforms INR-BSCP, suggesting that the B-Spline parameterization accounts for much of INR-BSCP's effectiveness. On DIR-LAB 4DCT, where respiratory motion is larger and more coherent, single-scale B-Spline methods (D-BSCP and INR-BSCP) are less suitable, while INR-Dense and MR-D-BSCP are more effective. Across both tasks, MR-D-BSCP achieves the best performance among the tested continuous parameterizations. These findings highlight that registration accuracy depends strongly on matching the induced deformation prior to the target motion pattern, and support prior-deformation matching as a practical design principle for medical image registration. Our code will be available at https://github.com/HengjieLiu/RightPriorDIR.

0.44

Domain-Adapted Latent Diffusion Models for CT-to-PET Image Translation

cs.CV ·2026-10-26 ·Yann Bourdé, Lea Bogensperger, Arnela Hadzic, Michael Krauthammer
similarity 0.62
Abstract

Positron Emission Tomography (PET) provides important metabolic information for tumor detection and staging but remains significantly less accessible than Computed Tomography (CT) due to its high cost, infrastructure requirements, and reliance on injected radioactive tracers. CT-to-PET image translation using generative models aims to address this disparity, yet state-of-the-art diffusion-based methods are limited by the scarcity of paired training data. To overcome this, we propose a domain-adapted latent diffusion framework that transfers natural-image priors using a relatively small dataset of 21,930 paired CT/PET slices, incorporating a signed power transform to resolve extreme intensity sparsity in PET data. Compared to CPDM, a state-ofthe-art baseline for CT-to-PET image translation, our approach yields superior performance in pixel-wise reconstruction and localized tumor fidelity, demonstrating effective transfer of natural-image priors to the medical domain. We further provide a systematic analysis of evaluation metric reliability for sparse PET data, showing that standard full-image metrics can be misleading indicators of translated image quality, and propose background-filtered and mask-restricted metrics as more clinically meaningful alternatives.

0.16

Efficient 3D Whole-Body PET Image Denoising via Conditional Rectified Flow With Optimized Sampling Strategy

cs.CV ·2026-09-15 ·Jiale Shen, Guolin Wang, Chenhao Wang, Xinhui Su, Wei Luo +1 more
similarity 0.61
Abstract

Reducing radiation exposure in Positron Emission Tomography (PET) is important for patient safety; however, ultra-low-dose imaging suffers from severe noise, which may affect diagnostic interpretation without appropriate image enhancement. While current 3D deep generative models, particularly diffusion models, have shown strong reconstruction fidelity, their practical use can be limited by long inference times. In contrast, faster 2D-based alternatives may have difficulty maintaining volumetric consistency, an important consideration for whole-body PET imaging analysis. To bridge this gap, we propose a one-pass conditional 3D rectified flow (3D Flow) framework for whole-body PET image denoising that incorporates a novel optimized non-uniform sampling strategy. The model is trained with a one-pass linear-interpolant velocity-matching objective. This approach reconstructs a full 3D volume in approximately 30 seconds in our implementation, compared with multi-hour inference for the evaluated 3D DDPM baseline. Evaluations including zero-shot transfer to an independent clinical dataset show that our model achieves favorable global image quality and lesion conspicuity compared with the evaluated 3D DDPM and DDIM baselines, including on challenging short-acquisition data. Furthermore, the proposed method shows promising zero-shot transfer performance across the evaluated datasets and unseen dose levels (down to 1/100 of the standard dose), with artifact-focused visual comparisons supporting the need for further lesion-level validation. By balancing reconstruction fidelity and computational efficiency, this work presents a candidate approach for ultra-low-dose whole-body PET image denoising.

0.08