CS Paper Radar

GRAFT-EEG: Gauge-Aware Physical Field Transport for Cross-Dataset Motor-Imagery EEG

Ying Zhou, Mengting Liu

cs.LG eess.SP ·submitted 2026-10-16 15:30 UTC · v1

Abstract

Cross-dataset EEG decoding often treats montage, reference, and active-sensor changes as representation shift, although they also alter the observation operator. We study target-statistics-blind transfer: fitting receives no target signal, label, or empirical statistic, and electrode coordinates only instantiate a fixed prediction operator. method removes the active-set common-reference gauge and transports each native mask through a template motor leadfield. A source-fitted spectral classifier anchors the decision; a bounded state-space-model (SSM) residual is secondary. We establish restricted identifiability and an operator-perturbation bound. Across five leave-one-dataset-out targets (253 participants), dynamic method achieved 60.865% equal-target balanced accuracy versus 52.684% for strict-clean 5/5 BIOT (hierarchical difference +8.182 points; 95% CI +6.382 to +10.196; positive in every target). On four EEGPT-clean targets, the descriptive means were 61.520% and 59.057%. In four post-hoc exact same-parent tests, FULL exceeded coordinate-basis, matched-spectrum, row-shuffled, and wrong-anatomy controls by 9.959, 9.698, 11.241, and 3.985 points, respectively (all 95% CIs excluded zero; Holm-adjusted P<0.001). A separate 60-participant same-paradigm evaluation retained a positive physical-operator contrast (+4.029 points; +2.338 to +5.773), whereas dynamic--static was inconclusive; its preregistered status is partial confirmation rather than unrestricted external validation. The SSM added +1.059 points (+0.013 to +1.892). Claims remain bounded to five binary motor-imagery domains and the tested operators.

Comment
Under review at ICLR 2027

Closest papers

Nearest neighbours by meaning across the whole index.

Lightweight Adaptation of EEG Foundation Models for Stroke Motor Imagery Decoding: Domain Shift and Subject-Level Robustness

cs.CE cs.LG ·2026-08-31 ·Anh T. Nguyen, Zihua Sun, Michelle J. Johnson
benchmark similarity 0.67
Abstract

Motor imagery (MI) electroencephalography (EEG) decoding could support post-stroke rehabilitation, but models developed on healthy cohorts may not transfer reliably to pathological EEG. We evaluated whether Low-Rank Adaptation (LoRA) can efficiently adapt three pretrained EEG foundation models (i.e., LaBraM-base, REVE-base, and REVE-large) for binary left- versus right-hand MI decoding. Frozen-backbone head-only baselines and LoRA adaptation were evaluated using subject-wise five-fold cross-validation on the PhysioNet EEG Motor Movement/Imagery Dataset and a binary subset of the UET175 dataset comprising 30 stroke participants. On EEGMMIDB, LoRA increased accuracy to 0.822 for LaBraM-base and 0.957 for REVE-base. On UET175, all head-only models performed near chance. With LoRA, LaBraM-base remained near chance (0.499$\pm$0.009), whereas REVE-base reached 0.847$\pm$0.194 and outperformed REVE-large (0.806$\pm$0.178), indicating that increased model capacity alone did not improve stroke-domain adaptation. The strongest stroke configuration, REVE-base LoRA, was further evaluated using within-cohort leave-one-subject-out cross-validation (LOOCV), showing 0.952 mean accuracy, but subject-wise accuracy ranged from 0.586 to 1.000, revealing a small low-performing tail. Zero-shot transfer from EEGMMIDB to UET175 remained near chance (0.464$\pm$0.072). These findings show that healthy-benchmark performance does not ensure transfer to stroke EEG. Translation of EEG foundation models to pseudo-online or real-time rehabilitation BCIs should therefore include target-domain adaptation and subject-level assessment of temporal informativeness, spatial sensitivity, and physiological discriminability.

0.28

Motor Imagery Classification Using Hybrid Cross-Subject Class Mixup and Selective Attention

cs.LG ·2026-11-16 ·Jiwon Kim, Chae-Won Lee, Jong-Seok Lee
similarity 0.66
Abstract

Motor imagery (MI) enables a brain-computer interface (BCI) to decode movement intentions without overt movement. Hybrid electroencephalography (EEG) and functional near-infrared spectroscopy (fNIRS) classification combines complementary signals, but inter-subject variability and the design of information exchange between modalities affect generalization to new subjects. We propose a framework that combines Cross-Subject Class Mixup (CSCM) with Selective Attention. CSCM aims to construct new training data to make the model robust against inter-subject variability. It independently selects EEG and fNIRS donor trials from other training subjects within the anchor class and mixes each modality while preserving the original label. Selective Attention provides an effective way to simultaneously model the temporal signal characteristics and fuse the two modalities. It retains causal temporal self-attention for EEG and uses a classification token (CLS) to integrate both modalities, without fNIRS attention updates or direct cross-modal temporal-token attention. Leave-one-subject-out (LOSO) evaluation across 28 subjects on a public EEG-fNIRS dataset yields a mean balanced accuracy (BA) of 76.85% and a macro-averaged F1 score (Macro-F1) of 76.58%. The proposed model achieves the highest mean performance among five reimplemented baselines. We also examine the contributions of CSCM and Selective Attention through modality-specific mixing and donor-policy comparisons, temporal-policy comparisons, interventions on direct cross-modal paths, and component ablations.

0.12

Reference Coordinates, Output Perturbations, and Information Loss in EEG Decoding

eess.SP ·2026-11-17 ·Runni Zhou, Rongrong Fu, Xinghao Yan, Xiaoyang Li
similarity 0.65
Abstract · 45 pages including supplementary material; 5 figures in the main text. Data and code included as ancillary material

Electroencephalography (EEG) decoders can respond to reference changes that preserve all relative-potential information. We use established measurement-operator theory to distinguish coordinate sensitivity, additional output-channel perturbations, and electrode loss. Exact pseudoinverse alignment supplies a consistency control; measurement-operator canonicalization (MOC) denotes a graph-Tikhonov estimator. The broader evaluation covers three public motor-imagery datasets and four decoders. The primary EEGNet comparison on Cho2017 and PhysioNet uses three paired training seeds, three shared noise realizations, and six front ends, with identical CAR training inputs sharing checkpoints. At 10 dB output perturbation, MOC-minus-raw disagreement was -0.144 and -0.107, while balanced-accuracy differences were 0.044 and 0.050, respectively; these four contrasts passed the retained Holm correction. MOC also reduced disagreement relative to pseudoinversion across all three seeds in both cohorts. However, comparison with fixed graph smoothing after pseudoinversion did not establish an additional MOC benefit. Preserving zero reference rows changed raw disagreement by less than 0.001 in magnitude; inverse-method predictions were unchanged. For canonical front ends, cross-reference disagreement was close to the reference obtained from independent noise within the same operator. Controlled weak-mode reconstruction and equal-rank electrode masks exposed separate stability and information-loss effects. The results locate the complete-reference gains within spatial processing under the specified stress model, while requiring decoding accuracy alongside consistency to assess practical utility.

0.33

Benchmarking Label-Revealed Online Updates for EEG BCI Decoding

cs.LG eess.SP ·2026-10-05 ·Bogdan Kozyrskiy, Artem Grachev, Abraham I. Camelo Guerrero
benchmark similarity 0.65
Abstract

Electroencephalography (EEG) signals drift over time, which can cause static brain-computer interface (BCI) models to degrade in practice. We present a benchmark for online adaptation and compare two widely used pipeline families, Common Spatial Patterns (CSP) and Riemannian covariance-based methods, under time-ordered prequential (test-then-train) evaluation. We examine (i) which pipelines benefit most from label-revealed updates, (ii) whether controlled forgetting of older data improves robustness, and (iii) how a minimal-calibration cold start compares with starting from a pretrained model. Across four datasets (three motor-imagery datasets and one movement-decoding dataset), label-revealed online updates improve 13 of 14 model/dataset pairs on the two largest streams, with relative accuracy gains of up to about 18% over a frozen model. A Shapley-based data-valuation analysis over temporal blocks assigns the largest mean value to the most recent block in each of the three analyzed datasets, while older blocks retain positive value.

0.20

Taming foundation model with invariance-oriented pre-training for broad-spectrum EEG analysis across signal-level, brain-state, and brain-health tasks

cs.LG cs.AI ·2026-08-25 ·Yulong Dou, Han Wu, Guo Chen, Fangmao Ju, Zhiming Cui +1 more
benchmark similarity 0.64
Abstract

Electroencephalography (EEG) is a widely used window into human brain function, but most EEG models remain tied to a one-dataset-one-model supervised paradigm. Recent EEG foundation models offer a route toward reusable representations, but most remain reconstruction-centered, assuming that EEG content predictable from local context is necessarily transferable neural information. Here we present INCEPT, an invariance-oriented EEG foundation model trained on over 11,000 hours of unlabelled clinical EEG. Rather than prioritizing signal recovery alone, INCEPT learns representation-level stability across correlated EEG observations, separating stable neural structure and essential subject-sensitive information from the nuisance variability that dominates scalp recordings while preserving subject-, state- and condition-discriminative information. We evaluate INCEPT on a broad-spectrum benchmark of ten datasets spanning three levels of post-acquisition EEG analysis: signal-level assessment, brain-state decoding, and brain-health evaluation. INCEPT ranks first among recent EEG foundation models on 26 of 30 linear-probing metrics and 24 of 30 fine-tuning metrics, and also surpasses strong task-specific specialist encoders across diverse downstream settings. Objective ablations and representation analyses further show that invariance-oriented pre-training improves transfer and organizes subject-sensitive neural representations beyond reconstruction alone. These results establish invariance learning as a promising principle for building reusable EEG foundation models.

0.11

Neural State Prediction: Obstructing Shortcut Learning in EEG Foundation Models

cs.AI ·2026-09-25 ·Kieren Yu, Ziyang Liu, Chang Huang, Jintai Chen, Kaishun Wu
similarity 0.64
Abstract

EEG foundation models increasingly use masked prediction to learn from unlabeled recordings, but optimizing this objective does not ensure transferable neural representations. A central challenge is that stable positional cues and local correlations can make masked regions predictable without integrating distributed neural context. To reduce this reliance on low-information prediction paths, we introduce Neural State Prediction (NSP), a latent-predictive framework that constrains both the prediction target and the available context. NSP uses a Target Encoder updated by an exponential moving average (EMA) to define latent supervision. Identity residualization removes additive effects associated with channel identity and relative time from the targets, while topology-separated context excludes their immediate spatial and temporal neighborhood from the visible input. We pretrain NSP on 2.2 million EEG segments from TUEG and evaluate it across 30 downstream datasets spanning clinical diagnosis, sleep staging, emotion recognition, motor imagery, event-related potentials, cognitive-state decoding, and language retrieval. Under full-parameter multi-task fine-tuning on EEG-FM-Bench, NSP achieves 63.94 macro balanced accuracy across 14 datasets, exceeding the strongest evaluated baseline by 2.35 percentage points. Controlled component ablations assess the contribution of each mechanism, while matched context controls and held-out interventions characterize the role of context geometry, signal content, and positional information. Jointly designing latent targets and their context offers a promising direction for EEG foundation models that learn from distributed signal structure.

0.21

Matched-Input Estimates Differ in Sign Across Architectures: Auditing EEG Foundation Models on Motor Imagery

cs.LG q-bio.NC ·2026-09-20 ·Kevin Zhou, Sparsh Roy
similarity 0.63
Abstract

Pretrained EEG foundation models are increasingly proposed as general-purpose encoders for brain-computer interfaces, yet recent benchmarks disagree about when their representations transfer to downstream tasks. We audit LaBraM and CBraMod on motor imagery under a validation-locked protocol in which preprocessing, architecture, optimization, freeze depth, checkpoint, temperature, and method selection are determined using training-session data only. On four-class BCI Competition IV-2a, every supervised comparator evaluated here outperforms every foundation-model configuration, including validation-selected fine-tuning. We then examine a key confound: foundation models and task-specific decoders are normally evaluated using different input pipelines. Retraining three supervised architectures on the broadband arrays consumed by the foundation models produces matched-input accuracy differences of opposite sign across architectures: broadband input improves ATCNet by 0.078 accuracy while reducing EEG Conformer accuracy by 0.088. None of the three individual matched-input terms is significant after multiple-comparison correction at n = 9, so we treat the sign variation descriptively rather than as a formal architecture-by-pipeline interaction. These observed sign differences suggest that a single comparator may not provide an architecture-invariant decomposition of a pretrained-versus-supervised performance gap. The four-class deficit also does not reproduce uniformly across motor-imagery datasets: on two-class BNCI2014-004 we cannot detect the same separation between fine-tuned CBraMod and the supervised comparators. Finally, validation-fitted temperature scaling returns foundation-model calibration error to the supervised range despite substantially lower four-class accuracy.

0.32

NOMAD-EEG: Native Omni-Montage Adaptive Diffusion

cs.LG eess.SP ·2026-10-26 ·Abdulkader Helwan, Khadidja Henni, Lina Abou-Abbas
similarity 0.63
Abstract · 37 pages and 7 figures

Purpose. Electroencephalography (EEG) montages, channel counts and recording lengths vary widely, but most EEG foundation models are bound to the channel set and input length they were trained on. We aimed to build a generative EEG foundation model independent of the number, identity and order of electrodes and of the input length. Methods. NOMAD-EEG is a 12.0 M-parameter diffusion model that alternates state-space layers along time, without patches, with attention across electrodes identified only by their 3D scalp position. It was pre-trained on 147 h of unlabelled EEG from a single corpus and evaluated with frozen linear probes on ten datasets with 1 to 64 electrodes against seven foundation models run under one protocol, and on two unseen populations. Results. Despite its small size (12.0 M parameters against 69 M for REVE) and single pre- training corpus, NOMAD-EEG outperformed all seven foundation models on EEGMMIDB mo- tor imagery (balanced accuracy 0.442), Siena seizure detection (macro F1 0.622) and Bonn seizure detection (AUROC 0.999), had the highest accuracy of the seven compared models on TUEP epilepsy diagnosis (0.640) and, after fine-tuning, the highest \k{appa} (0.635) and weighted F1 (0.814) on TUEV event classification. It was the best of five models on P300 detection in autism with an unseen eight-electrode montage (AUROC 0.718). With only 5 of 19 electrodes, its mean AUROC fell only from 0.942 to 0.891. Conclusion. Identifying electrodes by position and modelling time without patches let one small model, pre-trained on one corpus, outperform much larger EEG foundation models on seizure detection, epileptiform event classification, epilepsy diagnosis and motor imagery.

0.14