CS Paper Radar

Passive Smartphone-Microphone Phonocardiography for Joint Maternal-Fetal Cardiac Well-Being Monitoring: A Longitudinal Self-Recorded Case Study in Late Pregnancy

Muhammad Mahboob Ur Rahman

eess.SP ·submitted 2026-10-17 09:16 UTC · v1

Abstract

Maternal and perinatal deaths are concentrated in low- and middle-income countries, where routine fetal monitoring is largely inaccessible. With the prevalence of smartphone as personal assistive gadget, we ask whether a phone's built-in microphone, with no extra hardware or emitted signal, can serve as a software-only maternal-fetal cardiac screening aid when moved from the chest to the lower abdomen? We report a longitudinal, self-recorded case study of a single subject (Z) over the last five weeks of a singleton pregnancy, later delivered at term without complications: 28 short, uncontrolled recordings (rest, morning, post-exercise). Lacking maternal/fetal ground truth, we exploit the prior that maternal and fetal heart rates occupy largely disjoint frequency bands, blindly decomposing a Shannon-energy envelope into two candidate-rate bands, and additionally probe a slower breathing-rate band as a rest/exercise discriminator. A fast, regular, fetal-plausible rhythm was recovered from most recordings and remained essentially unchanged across maternal activity states, consistent with normal fetal cardiac autonomy; a slower, noisier maternal-plausible rhythm was recovered less reliably. Beat-to-beat variability proved largely noise-dominated at our short window lengths, and the breathing-rate probe did not significantly separate rest from exercise; both are reported as negative findings. We position the work within AI for global health: a low-cost screening aid for remote and underserved communities, pending reference-validated follow-up, not a replacement for clinical monitoring.

Comment
11 pages, 6 figures, 4 tables, submitted to an IEEE venue for possible publication

Closest papers

Nearest neighbours by meaning across the whole index.

Automated Fetal Magnetocardiography Reconstruction Using a Biophysical Forward Model

eess.SP ·2026-10-23 ·Jonas Emrich, Karin Narushima, Lena Wunderl, Philipp Wunderl, Tobias Jensch +5 more
top venuecode/data similarity 0.60
Abstract · 29 pages, 16 figures. Includes supplementary material. Published in IEEE Transactions on Biomedical Engineering. Code: https://github.com/ML…

Objective: Fetal magnetocardiography (fMCG) enables early detection of cardiac disease by non-invasively measuring fetal electrophysiological activity. However, current signal estimation methods for fMCG require complex, labor-intensive human processing because they rely on blind source separation or template-based projection techniques. Methods: We propose an automated signal reconstruction approach that recovers fetal and maternal cardiac activity from fMCG measurements without manual annotation. Our approach leverages the relationship between measurements and cardiac signals via a biophysically grounded forward model that represents cardiac sources as time-varying magnetic dipoles. This enables reconstruction of physiologically interpretable three-dimensional vectorcardiographic signals along with their spatial position. Results: Validation on synthetic data with known ground truth confirms accurate recovery of cardiac source parameters. On real fMCG recordings, the reconstruction shows strong agreement with established reference methods. Conclusion: The proposed forward-model approach automatically reconstructs fetal and maternal cardiac activity from fMCG recordings and produces signals in an interpretable vectorcardiographic source domain. Significance: Automated, interpretable fMCG reconstruction could make fetal cardiac assessment more reliable and support potential translation into prenatal care.

0.50

CORAL: A Modality Invariant Framework for Robust Vital Sign Rate Estimation Using Correloform Analysis

eess.SP q-bio.QM ·2026-08-15 ·Jacob Trueb, Amey Kasbe, Aniruddh Srinivasan
benchmark similarity 0.59
Abstract · main manuscript: 11 pages, 2 tables, 4 figures supplemental materials: 25 pages, 4 tabes, 31 figures

Heart rate and respiration rate are crucial vital signs. We present CORAL to address challenges in automating continuous vital sign monitoring 1) in-hospital across broader populations (age, disease states), 2) at-home in telehealth and wellbeing applications (noise, placement), and 3) across data modalities (ECG, PPG, SCG, BioZ, etc.). We re-introduce Short-Time Autocorrelation Functions (STACFs) to introduce the correloform - a highly interpretable 2D signal transformation for tracking periodicity over time - and define CORAL as a generic analytical framework for robust rate estimation of quasi-periodic signals. We rigorously benchmark CORAL to show ubiquitous application in biosignals via capabilities arising by mathematical construction rather than domain-specific engineering, including rate estimation, resilient noise handling, automatic channel selection, and signal quality indication. CORAL achieves excellent instantaneous noninvasive fetal HR agreement in FECGSYNDB (F1 = 0.999) and ADFECGDB (F1 = 1.000). With difficult NICU neonates, CORAL estimates RR from wearable BioZ at r = 0.858 against breath-interval RR from simultaneous wired Philips impedance. CORAL SCG HR on CEBS achieves r = 0.990 and in free-living activity r = 0.970 when compared against commercial ECG. Without QRS detection, CORAL's instantaneous HR agrees with Pan-Tompkins and NeuroKit2 detectors as closely as they agree with each other (MIMIC-IV ICU ECG r = 0.87 to each vs. 0.88 between them). CORAL's HR standard deviation correlates strongly with interval-based HRV SDNN, even from mechanical SCG (CEBS r = 0.733) and across an ICU ECG cohort (r = 0.768).

0.10

CardioFusion-AI: Robust ECG--PPG Fusion for Multimodal Physiological Monitoring Under Signal Degradation

eess.SP cs.LGq-bio.QM ·2026-08-26 ·Navaneetha Krishnan Kamalakannan, Janakiraman Kamalakannan
code/data similarity 0.55
Abstract · 7 pages, 4 figures. Under review at IEEE Journal of Biomedical and Health Informatics. Code: https://github.com/ka-cyber/CardioFusion-AI

Wearable electrocardiogram (ECG) and photoplethysmogram (PPG) sensors are complementary but individually fragile: motion artifact, poor contact, and sensor dropout can degrade one or both signals. Fusion strategies that assume both modalities are equally trustworthy can become less reliable than a single clean modality under degradation. We present CardioFusion-AI, a framework whose signal-processing front end, including R-peak and systolic-peak detection, an Orphanidou-type signal-quality index, and beat-by-beat pulse transit time estimation, is validated on 53 real intensive-care recordings (848 windows; heart-rate mean absolute error 1.61 bpm for ECG and 2.78 bpm for PPG) and a real annotated fetal ECG database (R-peak F1 0.89-0.98). We then conduct a controlled synthetic degradation study comparing eight ECG-PPG fusion strategies across six degradation regimes spanning graded corruption and complete modality loss, using five independent training seeds. Attention fusion achieved the lowest descriptive overall error (1.66+/-0.43 bpm). Both adaptive gates reallocated weight toward the healthy modality under complete modality loss, but showed near-zero correlation between gate weight and signal quality under graded degradation (r = 0.10-0.24). Signal-quality conditioning produced a specific improvement under missing-PPG conditions (1.56+/-0.59 bpm), approaching the 1.48 bpm unimodal ceiling. With only five training seeds, no pairwise comparison survives Holm-corrected significance testing; effect sizes and confidence intervals are therefore reported. These results indicate that modality availability and modality quality are functionally distinct problems for adaptive fusion.

0.60

Wearable Biosensors for Early Detection and Continuous Monitoring of Postpartum Depression: A Human-Centered Approach

cs.HC ·2026-10-29 ·Emma Ricci-De Lucca, Elizabeth L. Murnane
similarity 0.55
Abstract · 2024 PhysioCHI: Towards Best Practices for Integrating Physiological Signals in HCI

Postpartum depression (PPD) is the leading cause of maternal mortality in the United States. However, there are significant gaps in PPD screening, detection, and treatment. A main challenge stems from limitations in existing methods for early PPD diagnosis and subsequent monitoring and intervention. Mobile technology that incorporates interactive interfaces and continuous wearable biosensors holds major potential to augment clinical decision-making and enhance PPD care. A number of compelling research directions exist in effectively developing such systems, including user experience design, sensing accuracy during perinatal stages, clinical integration and interoperability, acceptance and adoption, and privacy and ethics. By focusing on wearable devices that center women and their experiences, this paper discusses such challenges and opportunities at the intersections of HCI, inclusive physiological computing, and women's health.

0.27

Acoustic Respiratory Phase Detection on Mobile Devices

cs.AI cs.LG ·2026-11-12 ·Julian Szymanski, Tomasz Sankowski, Piotr Sulewski, Iwo Czartowski, Javier Medina Quero
similarity 0.54
Abstract

Breathing monitoring is important for well-being, stress regulation, and guided breathing exercises, yet existing approaches often rely on contact-based sensors or controlled environments. This paper presents a non-invasive framework for respiratory phase detection using acoustic signals recorded on commodity smartphones. The proposed hybrid CNN-Transformer architecture combines local spectral feature extraction with long-range temporal modeling to capture the cyclic structure of breathing. The model is evaluated using a Leave-One-Subject-Out (LOSO) protocol on the Foundation Dataset and on an independent unseen test set comprising over 1300 breathing cycles and 2 hours of continuous recordings. The proposed 3-class formulation achieves 72.85% frame-level accuracy and 96.6% cycle-level exhalation detection efficiency in the LOSO evaluation, while achieving 76.94% frame-level accuracy, a Cohen's Kappa score of 0.65, and 99.2% cycle-level exhalation detection efficiency on the unseen test set. Results suggest that accurate respiratory monitoring may be achievable under data-constrained conditions, indicating that appropriate temporal modeling can learn transferable respiratory representations and generalize to previously unseen participants. An end-to-end ONNX deployment pipeline enables privacy-preserving on-device inference with latency below 20 ms, supporting real-time monitoring on mobile and wearable devices.

0.14

BeatGraph: Self-Supervised Heartbeat Graphs for Infant ECG Representations from the Home Environment

cs.LG ·2026-09-25 ·Mohammad Nur Hossain Khan, M. S. Krafczyk, Beverly G. Bolster, Nancy McElwain, Mark A. Hasegawa-Johnson +1 more
benchmark similarity 0.53
Abstract

Electrocardiogram (ECG) foundation models typically tokenize the signal into fixed-length patches that ignore cardiac structure, so a patch may split a heartbeat and the number of beats in each patch shifts with heart rate. This matters most for infants, whose heart rates are higher and whose ECG differs from the adult, clinic-recorded 12-lead data these models are built on. A model for infant ECG should therefore reason about heartbeats directly rather than recover them from arbitrary patches. We propose BeatGraph, which makes the heartbeat its unit of representation, modeling each 30-second window as a graph of beats. A shared beat encoder embeds each heartbeat from its waveform and inter-beat intervals, a Transformer with positional encoding orders the beats in time, and residual graph attention layers relate every beat to every other before attention pooling yields a window embedding. We pretrain BeatGraph on our new corpus of unlabeled infant recordings by predicting masked-beat embeddings, then fine-tune it for each task. One backbone supports sleep-wake detection, infant-state classification, activity-source identification (infant- or caregiver-initiated movement), and affect recognition, improving macro-F1 over the strongest baseline on each task by 0.076 to 0.158. It also transfers across age groups, reaching 0.892 AUROC on the ZZU-pECG pediatric benchmark (ages 0 to 14), within 0.001 of the best published self-supervised ECG model, and matching that model under linear evaluation on the adult PTB-XL benchmark despite infant-only pretraining. Finally, to our knowledge, we release the first public infant ECG corpus collected in homes, classrooms, and laboratory settings with state and affect labels. It contains 3,408 hours of single-channel ECG from 143 infants aged 3 to 11 months, with unlabeled pretraining data, benchmark tasks, and subject-level splits.

0.26

BioSync: Transformer-Based Cross-Modal Fusion for a Multimodal Physiological Digital Biomarker

cs.AI cs.IR ·2026-09-03 ·Seyed Mahmoud Sajjadi Mohammadabadi
benchmark similarity 0.52
Abstract

Cardiac, neural, behavioral, and speech measurements from wearable and mobile devices provide partial, noise-sensitive views of physiological state. BioSync combines these measurements into the \textbf{BioSync Index (BSI)}, a continuous composite digital biomarker defined under the BEST framework. The model applies multi-head self-attention to modality tokens and adds a linear branch whose hypothesis class includes standard feature concatenation. This architecture is motivated by latent-variable measurement theory and by the possibility that joint observations contain information unavailable from individual modalities. We evaluated BioSync on two literature-informed synthetic cohorts: a four-modality cognitive-decline cohort using HRV, EEG, actigraphy, and speech, and a metabolic-autonomic cohort structured around the public AI-READI wearable schema. In the cognitive cohort, BioSync and concatenation obtained AUCs of 0.928 and 0.926, respectively. In the metabolic cohort, BioSync obtained accuracy/F1 of 0.764/0.766, compared with 0.756/0.758 for concatenation. The BSI correlated with latent severity in both cohorts ($r=0.91$ and $r=0.68$). A pure-attention ablation obtained cognitive-cohort AUC 0.911, locating the increase to 0.928 in the combined wide-and-deep architecture. With matched modality-dropout training, BioSync led concatenation at five of six cognitive-cohort corruption rates and at the highest metabolic-cohort rate. Its cognitive-cohort AUC was also higher than five published digital-biomarker reference values, although differences in datasets and tasks preclude a controlled benchmark claim. Comparison with single-modality, early-fusion, and late-fusion designs across six prespecified criteria identifies the model's computational properties; validation on real cohorts remains necessary.

0.17

Calibration-Free Cuffless Blood Pressure Estimation Using Multimodal ECG-PPG Fusion on a Google Pixel Watch

cs.HC ·2026-08-26 ·Jathushan Kaetheeswaran, Boyi Ma, Ali Abedi, Shehroz S. Khan, Milad Lankarany
hot direction similarity 0.51
Abstract

Inadequate blood pressure (BP) monitoring and management outside of clinical settings can worsen major cardiovascular risk factors such as hypertension. While cuff-based devices are commonly used for at-home monitoring, these devices can be inconvenient for daily use due to their sensitivity to body positions, upper-arm constrictions, and limited portability. A promising alternative is emerging in the form of consumer-grade smartwatches, where physiological signals related to cardiac activity can be used to estimate BP non-invasively and continuously across daily living conditions. In this work, we use data collected from a Google Pixel Watch in 40 participants to develop and compare several algorithm approaches for BP estimation. We found that our proposed deep learning model achieved the strongest overall performance, and that fusing smartwatch signals with demographic information improved model generalizability to unseen individuals. However, we also identified that model accuracy was not consistent across participant subgroups, with obese individuals yielding higher estimation errors than others. This study highlights the feasibility of consumer-grade smartwatches as accessible platforms for deploying robust BP estimation algorithms, though clinical reliability will require larger, more diverse populations and additional sensing modalities.

0.22