CS Paper Radar

Automated Fetal Magnetocardiography Reconstruction Using a Biophysical Forward Model

Jonas Emrich, Karin Narushima, Lena Wunderl, Philipp Wunderl, Tobias Jensch, Maximilian Huber, Peter Ewert, Peter Fierlinger, Annette Wacker-Gussmann, Reinhard Heckel

eess.SP ·submitted 2026-10-23 14:16 UTC · v1
top venuecode/data

Abstract

Objective: Fetal magnetocardiography (fMCG) enables early detection of cardiac disease by non-invasively measuring fetal electrophysiological activity. However, current signal estimation methods for fMCG require complex, labor-intensive human processing because they rely on blind source separation or template-based projection techniques. Methods: We propose an automated signal reconstruction approach that recovers fetal and maternal cardiac activity from fMCG measurements without manual annotation. Our approach leverages the relationship between measurements and cardiac signals via a biophysically grounded forward model that represents cardiac sources as time-varying magnetic dipoles. This enables reconstruction of physiologically interpretable three-dimensional vectorcardiographic signals along with their spatial position. Results: Validation on synthetic data with known ground truth confirms accurate recovery of cardiac source parameters. On real fMCG recordings, the reconstruction shows strong agreement with established reference methods. Conclusion: The proposed forward-model approach automatically reconstructs fetal and maternal cardiac activity from fMCG recordings and produces signals in an interpretable vectorcardiographic source domain. Significance: Automated, interpretable fMCG reconstruction could make fetal cardiac assessment more reliable and support potential translation into prenatal care.

Comment
29 pages, 16 figures. Includes supplementary material. Published in IEEE Transactions on Biomedical Engineering. Code: https://github.com/MLI-lab/fetal_magnetocardiography
Journal ref
IEEE Transactions on Biomedical Engineering (2026)
DOI
10.1109/TBME.2026.3745242

Closest papers

Nearest neighbours by meaning across the whole index.

SPARC: Slice-to-volume Pipeline for Automated Reconstruction of gated 3D+time fetal Cardiac MRI

cs.CV ·2026-08-19 ·Arnaud Boutillon, Naomi Clarke, Tomas Woodgate, Daniel West, Alina Schneider +6 more
similarity 0.60
Abstract

Fetal cardiac MRI (fCMR) provides valuable diagnostic information complementary to echocardiography, particularly for complex congenital heart disease (CHD). Dynamic cine imaging captures cardiac motion essential for assessment of cardiac function; however, the reconstruction of 3D+time cine volumes from 2D+time acquired slices remains challenging due to unpredictable fetal motion and the absence of automated and robust processing tools suitable for clinical deployment. We present the SPARC pipeline (Slice-to-volume Pipeline for Automated Reconstruction of gated 3D+time fetal Cardiac MRI) which combines physics-informed slice-to-volume reconstruction (SVR) of Doppler ultrasound (DUS) gated stacks of slices, assisted by deep learning (DL) models for thoracic segmentation and anatomical reorientation. The proposed SVR algorithm achieves a tenfold reduction in reconstruction time relative to existing frame-wise approaches ($4.8 \pm 1.0$ vs $49.0 \pm 14.1$ min, $p < 0.0001$) while improving the reconstruction quality. Thoracic segmentation performance using ensemble aggregation exceeded inter-rater agreement (Dice $84.7 \pm 3.9\%$ vs $81.4 \pm 7.7\%$, $p<0.05$), while anatomical reorientation achieved a success rate of $90.1\%$. End-to-end evaluation on a large held-out clinical cohort ($n = 121$) demonstrated fully automatic processing in $82.6\%$ of cases with a mean runtime of $7.1 \pm 1.3$ min, compatible with clinical deployment. The complete SPARC pipeline is publicly available as a Docker container https://hub.docker.com/r/aboutill/sparc and is currently deployed at our institution as a clinical research tool.

0.37

Passive Smartphone-Microphone Phonocardiography for Joint Maternal-Fetal Cardiac Well-Being Monitoring: A Longitudinal Self-Recorded Case Study in Late Pregnancy

eess.SP ·2026-10-17 ·Muhammad Mahboob Ur Rahman
similarity 0.60
Abstract · 11 pages, 6 figures, 4 tables, submitted to an IEEE venue for possible publication

Maternal and perinatal deaths are concentrated in low- and middle-income countries, where routine fetal monitoring is largely inaccessible. With the prevalence of smartphone as personal assistive gadget, we ask whether a phone's built-in microphone, with no extra hardware or emitted signal, can serve as a software-only maternal-fetal cardiac screening aid when moved from the chest to the lower abdomen? We report a longitudinal, self-recorded case study of a single subject (Z) over the last five weeks of a singleton pregnancy, later delivered at term without complications: 28 short, uncontrolled recordings (rest, morning, post-exercise). Lacking maternal/fetal ground truth, we exploit the prior that maternal and fetal heart rates occupy largely disjoint frequency bands, blindly decomposing a Shannon-energy envelope into two candidate-rate bands, and additionally probe a slower breathing-rate band as a rest/exercise discriminator. A fast, regular, fetal-plausible rhythm was recovered from most recordings and remained essentially unchanged across maternal activity states, consistent with normal fetal cardiac autonomy; a slower, noisier maternal-plausible rhythm was recovered less reliably. Beat-to-beat variability proved largely noise-dominated at our short window lengths, and the breathing-rate probe did not significantly separate rest from exercise; both are reported as negative findings. We position the work within AI for global health: a low-cost screening aid for remote and underserved communities, pending reference-validated follow-up, not a replacement for clinical monitoring.

0.26

Generalizable fetal brain biometry via adaptive artificial intelligence

cs.CV ·2026-10-11 ·Yijin Li, Mingxuan Liu, Yi Liao, Le Chang, Hongjia Yang +22 more
similarity 0.57
Abstract · 67 pages, 8 figures

Fetal brain biometry provides a quantitative basis for assessing prenatal growth and identifying congenital brain abnormalities. However, comprehensive assessment remains limited by labor-intensive manual measurements and automated models that lose accuracy across imaging sequences and institutions. We introduce BioTTA, an anatomically guided test-time adaptation framework that measures 11 fetal brain biometrics from reconstructed three-dimensional magnetic resonance images. BioTTA adapts pretrained models to individual unlabeled volumes using geometric consistency and atlas priors, without access to source images. In a retrospective study across five centers in China and Switzerland, BioTTA improved measurement accuracy across three out-of-distribution datasets and two network architectures. It reduced mean absolute measurement errors by 46-82% relative to the corresponding models without adaptation, achieving errors similar to those of supervised fine-tuning. Its measurements were mapped onto normative growth trajectories derived from expert annotations, enabling gestational-age-specific assessment through a web-based reporting platform. Across four disease cohorts, the platform achieved 82.1-95.0% accuracy in binary detection of ventriculomegaly or cerebellar abnormalities, with performance similar to that of a senior radiologist. BioTTA provides a practical foundation for standardized fetal brain biometry across heterogeneous imaging settings, supporting scalable prenatal growth assessment and quantitative evaluation of brain abnormalities.

0.13

Angel: Anchor-Structured Neural Gaussians for Explicit Fetal Diffusion MRI Slice-to-Volume Reconstruction with Cross-Subject Learning

eess.IV ·2026-11-12 ·Wenxuan Wu, Lucy Hall, Jonathan O'Muircheartaigh, Joseph V. Hajnal, J-Donald Tournier +1 more
similarity 0.57
Abstract

Diffusion magnetic resonance imaging (dMRI) provides a noninvasive view of developing tissue microstructure and white matter tracts in the fetal brain. During acquisition, however, fetal motion disrupts spatial correspondence between slices, diffusion encoding directions and signal intensities. We introduce ANGEL, an anchor-structured neural Gaussian framework for accurate slice-to-volume reconstruction (SVR) of fetal dMRI, that simultaneously estimates diffusion signal, fetal motion and intensity artefacts. Unlike standard explicit Gaussian representation, ANGEL is designed to prevent absorption of noise and artefacts into the reconstructed dMRI by learning a compact representation of spatio-angular signal via a shared decoder that predicts 3D Gaussians across anchors and subjects. The individual anatomical variability is compactly represented through subject-specific anchors. Experiments on simulated neonatal and in vivo fetal data show significant improvement of dMRI reconstruction in both spatial and angular domains, in comparison to explicit Gaussian representation, implicit neural representation as well as classical methods.

0.14

WASP: Weakly Aligned Spatiotemporal Pairs for Fetal Brain MRI-Ultrasound Learning

cs.CV cs.LG ·2026-10-03 ·Francesco Correnti, Gabriele Magrini, Marco Mistretta, Niccolò Biondi, Pietro Pala +4 more
top venuecode/data similarity 0.56
Abstract · Accepted at NeurIPS 2026. 21 pages, 3 figures, 11 tables. Code: https://github.com/miccunifi/WASP

Magnetic Resonance Imaging (MRI) is widely regarded as the optimal sensor for fetal brain analysis due to its superior soft-tissue contrast and anatomical detail. However, its high cost and operational burden make it invasive and difficult to obtain at scale. Ultrasound (US), in contrast, is cheap, safe, and routinely acquired, and as a result it has produced substantially larger datasets and a growing ecosystem of pretrained models. This asymmetry raises a natural question: Can we teach a US-only model to understand fetal MRI from only a limited set of examples? The standard recipe, training a foundation model on subject-to-subject paired MRI-US scans, is not viable since no such paired fetal dataset is publicly available. In this paper we address this gap with Weakly Aligned Spatiotemporal Pairs (WASP), a framework that formulates cross-modal correspondence as an entropic Optimal Transport problem driven by clinical metadata, in particular Gestational Age (GA) and diagnostic planes, enabling the fitting of a lightweight alignment module that lifts MRI representations into the US latent space, without fine-tuning the backbone. Empirically, WASP yields its largest gains when MRI is unseen by the model during pretraining (on USFM, GA estimation error drops from 21.9 to 17.4 days and standard plane classification accuracy climbs from 61.9% to 69.0%), while providing smaller, backbone-dependent refinements for backbones pretrained on both modalities (e.g., BioMedParse GA estimation error from 6.5 to 6.0 days and SAM-Med2d plane accuracy from 83.3% to 88.1%). Code is available at https://github.com/miccunifi/WASP.

0.46

MS-ECG-FM: Towards a More Universal Electrocardiogram Foundation Model for Health Monitoring using Multi-source Contrastive Learning

cs.LG ·2026-10-06 ·Robert A. Lewis, I-Min Chiu, Kyle Verrier, Karthik Jayaraman Raghuram, Francoise Marvel +5 more
similarity 0.56
Abstract · Andrew C. Miller, Joseph Futoma: equal contribution. 52 pages, 4 figures, 20 tables, including supplementary information

Electrocardiography (ECG) records the electrical activity of the heart, aiding diagnosis by detecting abnormalities in cardiac function. ECG foundation models have demonstrated promising results, but are limited by a reliance on ECG interpretation reports as their sole supervision. Because interpretation reports only capture the subset of waveform information routinely recognized by clinicians, this constrains representation learning to overlook the broader diagnostic signals present in ECG. We introduce a new ECG foundation model --- MS-ECG-FM --- that is trained through contrastive alignment to multiple distinct clinical note types, including ECG, echocardiography, radiology, and discharge reports. We evaluate MS-ECG-FM on an extended set of ECG detection benchmarks, showing that it comprehensively outperforms existing methods on the full span of conditions that ECG can detect, including in reduced-lead configurations. Different reports improve representations for different diagnostic domains, while multi-source alignment captures their complementary information and produces consistently strong representations across clinically diverse tasks.

0.33

Pos4CHD: A Positive-Free Mask-Guided Counterfactual Synthesis Framework for Fetal Congenital Heart Defect Analysis

cs.CV ·2026-10-22 ·Wenjie Xuan, Yapeng Li, Hang Su, Chen Cheng, Juhua Liu +3 more
code/data similarity 0.56
Abstract · Submitted to IEEE TMI, under review

The scarcity of positive cases remains a major bottleneck in developing automated diagnostic systems for fetal Congenital Heart Defects~(CHDs), particularly for rare subtypes. Although normal cases are accessible with effort, positive cases are hard to collect due to low incidence rates and privacy concerns, causing severe class imbalance or absence of positive training samples. Existing works resort to synthesizing positives with conditional generative models, but they are task-specific and require positive training samples, hindering application for fetal CHDs. To this end, we propose a positive-free mask-guided counterfactual generation framework for fetal echocardiography, namely Pos4CHD, which enables realistic, high-quality synthesis of pseudo-positive samples from semantic masks, with only normal samples at hand. Technically, we first develop FE-Gen, a mask-guided generative model tailored for fetal heart ultrasound synthesis that mitigates histogram drift and enhances image-mask spatial alignment. Building on FE-Gen, Pos4CHD employs a mask-to-image generation paradigm for CHD synthesis. It first manipulates semantic masks to simulate fetal-heart structural anomalies and then renders anatomically consistent images. Extensive experiments on in-house datasets, together with expert evaluations, demonstrate the visual fidelity~($-12.97$ FID) and anatomical consistency~($+3.96\%$ DSC) of synthesized images. Further validations across diverse real-world CHD diagnosis tasks exhibit promising results and consistent increments, including zero-shot classification~(achieving $93.25\%$ ACC on EbA and $72.92\%$ ACC on TAPVC), lesion detection~($+6.95\%$ mAP50 on VSD), and anatomy segmentation~($+10.49\%$ DSC on fetal heart) compared with baselines. Codes and models are publicly available on \href{https://github.com/DREAMXFAR/Pos4CHD}{GitHub}.

0.37

CardioFusion-AI: Robust ECG--PPG Fusion for Multimodal Physiological Monitoring Under Signal Degradation

eess.SP cs.LGq-bio.QM ·2026-08-26 ·Navaneetha Krishnan Kamalakannan, Janakiraman Kamalakannan
code/data similarity 0.55
Abstract · 7 pages, 4 figures. Under review at IEEE Journal of Biomedical and Health Informatics. Code: https://github.com/ka-cyber/CardioFusion-AI

Wearable electrocardiogram (ECG) and photoplethysmogram (PPG) sensors are complementary but individually fragile: motion artifact, poor contact, and sensor dropout can degrade one or both signals. Fusion strategies that assume both modalities are equally trustworthy can become less reliable than a single clean modality under degradation. We present CardioFusion-AI, a framework whose signal-processing front end, including R-peak and systolic-peak detection, an Orphanidou-type signal-quality index, and beat-by-beat pulse transit time estimation, is validated on 53 real intensive-care recordings (848 windows; heart-rate mean absolute error 1.61 bpm for ECG and 2.78 bpm for PPG) and a real annotated fetal ECG database (R-peak F1 0.89-0.98). We then conduct a controlled synthetic degradation study comparing eight ECG-PPG fusion strategies across six degradation regimes spanning graded corruption and complete modality loss, using five independent training seeds. Attention fusion achieved the lowest descriptive overall error (1.66+/-0.43 bpm). Both adaptive gates reallocated weight toward the healthy modality under complete modality loss, but showed near-zero correlation between gate weight and signal quality under graded degradation (r = 0.10-0.24). Signal-quality conditioning produced a specific improvement under missing-PPG conditions (1.56+/-0.59 bpm), approaching the 1.48 bpm unimodal ceiling. With only five training seeds, no pairwise comparison survives Holm-corrected significance testing; effect sizes and confidence intervals are therefore reported. These results indicate that modality availability and modality quality are functionally distinct problems for adaptive fusion.

0.60