CS Paper Radar

MRI Reconstruction Risk Estimation from Inference Dynamics

Tamir Shor, Alex Bronstein

cs.CV ·submitted 2026-10-19 15:17 UTC · v1

Abstract

Iterative MRI reconstructors produce intermediate estimates before returning a final image. We study these inference trajectories as a model-internal representation of realized reconstruction risk, measured by log-NMSE. Model-native states are projected to magnitude images, summarized by a fixed 16-dimensional descriptor, and mapped to risk using a source-trained ridge readout. Across three reconstruction backbones, trajectory features are strongly predictive of reconstruction risk on held-out source data. Under zero-shot target shift, their behavior is backbone-dependent, exhibiting both preserved positive association and readout reversal. Conditional analyses show that trajectory information can remain associated with error beyond an initialization-only predictor. A prefix analysis further shows that useful trajectory information can emerge before reconstruction completes. Repeated-mask and low-shot calibration studies indicate that trajectories primarily encode persistent case difficulty, while their orientation and calibration can change under domain shift.

Closest papers

Nearest neighbours by meaning across the whole index.

Stochastic Finite-Transition Learning and Exploration for Accelerated MRI Reconstruction

eess.IV cs.CVeess.SP ·2026-10-09 ·Muhammad Usama Mirza, Esin Öztürk Işık, Tolga Çukur
similarity 0.68
Abstract

Generative MRI reconstruction maps an initial source distribution to the target image distribution along a learned recovery trajectory. Common generative methods, such as diffusion and flow, typically learn fine-grained local dynamics whose integration defines this global mapping, hence requiring many network evaluations at inference. Existing few-step sampling approaches can lower computational burden by approximating large transformations from local dynamics, albeit at the expense of reconstruction fidelity. FLEX-MRI instead partitions recovery into a small number of finite intervals between retained states defined by progressive changes in k-space support, and directly learns the reconstruction change across each interval. Because such finite transitions can admit multiple plausible outcomes, FLEX-MRI combines support-relaxed finite-transition learning with stochastic exploration. During training, randomized k-space sampling masks define finite-transition targets with varying support, while the prediction loss remains unrestricted by each individual mask. At inference, FLEX-MRI perturbs a random subset of currently estimated k-space coefficients, allowing the learned predictor to stochastically explore alternative transition paths. Each predicted state is then reconciled with the acquired measurements through data consistency. We theoretically show that this stochastic exploration induces nonzero transition-level variation through the learned recovery map and data consistency without requiring an auxiliary generative sampler. Experiments on multi-coil MRI datasets show that FLEX-MRI outperforms competing methods while maintaining computational efficiency comparable to few-step baselines.

0.23

CARD: Calibration via Agreement in Reverse Diffusion for Out-of-Domain MRI Segmentation

cs.CV ·2026-08-26 ·Jiaheng Dai, Weidong Guo, Qingbiao Li, Jie Xu, Yi Guo +2 more
similarity 0.66
Abstract · 10 pages, 5 figures

Probability calibration aligns model confidence with predictive accuracy, enabling clinicians to identify unreliable segmentation regions. This alignment breaks down under domain shift, where artifacts and unseen protocols produce confident errors. Existing post-hoc methods adapt the correction at test time, conditioning on predictive entropy, the logit pattern, or augmentation response, but each proxy is read from the terminal prediction, the very quantity that shift corrupts. This motivates reliability evidence beyond the terminal prediction, which categorical diffusion provides in two ways. First, a generative shape prior keeps a capacity-limited reference intact when appearance is corrupted, so its disagreement with the primary segmentor highlights primary-model errors. Second, every reverse step yields a class distribution, separating persistent disagreement from transient discrepancy. Aggregated over the trajectory, this disagreement correlates with Dice at 0.788, against 0.521 for a matched discriminative control. We therefore propose CARD (Calibration via Agreement in Reverse Diffusion), which maps the temporal aggregate of this disagreement to a temperature field applied per pixel across all classes, so that confidence changes while the segmentation does not. Across cardiac, prostate and brain MRI shifts, CARD lowers calibration error in 45 of 49 comparisons against the strongest baseline in each setting.

0.22

Self-Reconstruction Dynamics for Autoencoder Reconstruction Refinement

cs.LG ·2026-09-26 ·Hitoshi Iyatomi
similarity 0.63
Abstract · 23 pages, 12 figures

Standard autoencoder (AE) inference uses a single encoder-decoder pass, though the latent may not be optimal for each sample under a fixed decoder. We ask whether a trained AE can reveal information for improving its own reconstruction. Repeated application of a frozen AE to its reconstruction produces transient image- and latent-space trajectories, termed Self-Reconstruction Dynamics (SRD). Although this degrades fidelity in the AEs studied here, SRD contains sample-specific information for correcting the reconstruction. We propose SRD-guided Reconstruction Refinement (SRD-RR), which predicts a latent correction from a short SRD with the AE frozen and no per-sample test-time optimization. We also introduce MSE-recov, an MSE recovery ratio relative to an empirical decoder-optimized reference. Across six datasets, SRD-RR recovers 38.6% of the empirically recoverable MSE gap with one transition and 45.3% with two. A two-transition variant trained without direct access to original images, using an SRD-derived pseudo-target, achieves 40.7% recovery and a 1.74 dB average PSNR gain. Removing trajectory information reduces the gain, while cross-sample trajectory assignment causes severe degradation, confirming strong sample specificity. Nonlinear SRD-conditioned refinement consistently outperforms fixed and trained linear latent correction. On a pretrained DINOv2-based representation autoencoder (RAE) with substantially different latent dynamics, SRD conditioning again improves a matched trajectory-free predictor. However, pixel-MSE latent refinement reveals a strong mismatch between pixel fidelity and perceptual quality, while the SRD-derived pseudo-target mitigates this degradation. Overall, SRD is a useful sample-specific refinement signal, while the objective determines how it translates into pixel and perceptual quality.

0.29

FFAI: Flow Matching with Feedback Training and Adaptive Initialization for CT Reconstruction

cs.CV ·2026-10-29 ·Jigang Duan, Heran Wang, Genwei Ma, Xing Zhao
benchmark similarity 0.63
Abstract

Although low-dose, sparse-view, and limited-angle CT involve distinct degradation mechanisms, all three pose reconstruction challenges due to limited measurement information and can therefore be addressed within a unified framework. In iterative image restoration with flow matching, prediction errors may cause inference states to deviate from the prescribed training path, while a fixed initialization may be unsuitable for inputs with varying degradation severity. We propose a unified conditional flow matching method that conditions on the initial reconstruction and combines feedback-aware training with degradation-adaptive initialization. During training, a teacher network simulates inference updates to generate shifted states, from which a student network learns to recover high-quality reference images, improving its ability to handle prediction errors. During inference, the starting time is selected based on the noise level or extent of missing projection data, and the noise added to the initial state is adjusted accordingly to adapt the starting point to the input. Experiments on public benchmark datasets show that the proposed method achieves better quantitative results than the compared methods across all three reconstruction tasks, effectively suppressing noise and artifacts while preserving anatomical structures and details.

0.19

Measuring Structured Predictability in Neural Training Dynamics: A Cross-Regime Study

cs.LG ·2026-08-16 ·Fanqi Wang, Weisheng Tang, Hairong Qi
similarity 0.62
Abstract · 42 pages, including supplementary material

Modern deep networks are trained through long update trajectories, yet their temporal organization remains less systematically characterized than architectures, losses, or optimizers. We study short-horizon predictability as a measure of temporal redundancy: where, when, and under which training conditions recent updates contain information about near-future parameter motion. We combine three complementary probe families, displacement-direction, subspace-residual, and predictor-based probes, with convention-aware, null-calibrated group-level readouts, and apply them to multi-pass vision training on CIFAR and public Pythia pretraining checkpoints. Across both regimes, vector-like tensors such as normalization parameters and biases (auxiliary parameters) exhibit simpler short-horizon dynamics than matrix-like feature-transforming weights (bulk parameters), whose predictable behavior concentrates in localized, time-varying pockets. Agreement within and across probe families, and with independent trajectory diagnostics, indicates that these measurements capture intrinsic trajectory structure, while probe differences distinguish complementary forms of temporal organization. Controlled CIFAR comparisons further show that architecture and training recipe systematically modulate the measured structure. A Pythia-70M case study further exposes a sequence of role-, depth-, and scale-dependent events, including bulk ESA falling below the random sign-agreement level and the emergence and redistribution of predictable qkv pockets across layers. These results position short-horizon predictability as a retrospective, parameter-resolved diagnostic of training dynamics.

0.10

FM-Recon: Exploring Foundation Model Features for Accelerated Cardiac Cine MRI Reconstruction

cs.CV cs.AI ·2026-11-16 ·Donghang Lyu, Marius Staring, Ruochen Gao, Jochen Keupp, Hildo J. Lamb +1 more
similarity 0.61
Abstract

Foundation models have demonstrated strong feature extraction capabilities across various medical imaging tasks, yet their potential for MRI reconstruction remains largely unexplored, particularly within unrolled reconstruction networks and under artifact-corrupted inputs. In this work, we explore whether and how features from pretrained foundation models can benefit accelerated cardiac cine MRI reconstruction. To this end, we propose FM-Recon, a framework that refines and integrates extracted features from frozen image encoder of foundation models into an unrolled reconstruction network. Through extensive experiments on the CMRxRecon2023 dataset, we systematically evaluate foundation model features across different reconstruction settings. Our results show that foundation models can extract informative representations from artifact-corrupted inputs and improve reconstruction performance, particularly at moderate acceleration factors. These findings demonstrate the potential of foundation model features for accelerated MRI reconstruction and provide insights into their effective integration into unrolled reconstruction networks.

0.05

STAIRS: Staging the Inverse Problem via Admissible-Support Scheduling for Unrolled MRI Reconstruction

cs.CV ·2026-11-06 ·Xiangjian Hou, Chang Ni, Chao Qin, Zhiwei Tan, Xin Wang +4 more
similarity 0.60
Abstract

Accelerated magnetic resonance imaging (MRI) forms images from incomplete Fourier measurements, shifting acquisition burden to computational reconstruction. Deep unrolled networks interleave learned regularization and data consistency, yet typically estimate the full unmeasured spectrum at every cascade. We propose STAIRS (Staging the Inverse Problem via Admissible-Support Scheduling), which projects intermediate reconstructions onto nested Fourier supports that expand to the full spectrum and conditions each update on its support transition. Conditional increments of a regularized log-determinant score of training covariance define a normalized spectral coordinate, accounting for dependencies between newly and previously admitted frequencies. Dyadic targets allocate larger coordinate increments to earlier cascades and are mapped to fixed supports before training, enabling coarse-to-fine reconstruction with unchanged sampling masks and data consistency. On fastMRI and Stanford2D, STAIRS improves matched Transformer (HUMUSNet) and convolutional (NAFNet) backbones in single- and multi-coil reconstruction, including radiologist-annotated pathology regions. It also outperforms predictor-based progression with lower parameter overhead and inference latency. Stage-wise analysis shows repeated error correction by projection and lower intermediate reconstruction errors than the backbones alone throughout support expansion. Ablations favor dyadic allocation over uniform expansion for square and line-band supports and over manual front-loading for square windows. Support projection alone improves reconstruction, and transition conditioning strengthens the gain. Cross-dataset evaluation shows improvements for both backbones in both directions. Support allocation thus complements regularizer design in unrolled MRI reconstruction.

0.22

VariaFlow: Uncertainty-Aware Flow Matching for Unsupervised Anomaly Detection

cs.CV ·2026-10-30 ·Arnela Hadzic, Martin Urschler, Cosmin I. Bercea
published similarity 0.60
Abstract · Accepted for WACV 2027

Reconstruction-based anomaly detection no longer fails at reconstruction. Generative models produce high-quality pseudo-healthy reconstructions, and the remaining difficulty is the step of scoring residuals. The residual between a scan and its reconstruction has two indistinguishable sources, genuine pathology and the anatomical variation that separates one healthy brain from another. Scoring against a single reconstruction treats both as anomalous, inflating false positives where healthy anatomy varies most while small or subtle lesions are lost in the surrounding reconstruction error. We identify the missing quantity as the predictive variance, how much a healthy reconstruction can vary at each location. We introduce VariaFlow, which estimates this variance from an ensemble of mask-guided restorations under an unconditional flow matching prior, each started from a different noise initialization, and which normalizes the residual by the resulting standard deviation. Few-step flow matching keeps the ensemble computationally affordable, and restoring at two spatial scales captures lesions of different size. Across three brain MRI datasets spanning stroke and tumor, VariaFlow is trained once on healthy anatomy and generalizes across all three, attaining the highest AUROC (0.94, 0.80, 0.78) on each and the highest AUPRC on both cross-domain datasets, exceeding the strongest baseline by 37% and 50%. Under domain shift, the same baseline drops by up to 52% in AUPRC, whereas VariaFlow stays more stable and achieves the best small-lesion Dice on all three datasets.

0.29