CS Paper Radar

Improved three component IVIM fitting using physics-informed neural network with multimodal spatial prior

Nhat Hoang, Abrar Faiyaz, Emmanuel A. Mensah, Md Nasir Uddin, Jianhui Zhong, Giovanni Schifitto

eess.IV ·submitted 2026-10-20 19:46 UTC · v1
code/data

Abstract

Purpose: To mitigate parameter degeneracy and improve robustness of IVIM fitting, a multimodal physics-informed neural network was developed to leverage anatomical information through the combined use of cross attention, selective spatial gating, and anatomy-weighted spatial prior. Methods: T1w and FLAIR anatomical images were co-registered to IVIM signal in native space and segmented by tissue type. The proposed Physics-Anchored Cross-attention Embedding network (PACE) encoded IVIM signals and their anatomical features in parallel branches, then integrated them via cross attention and spatial gating. An anatomy-weighted spatial prior further constrained signal reconstruction using anatomically similar neighboring voxels. PACE and its prior-guided variant were compared with two baseline deep neural networks (DNN and IVIM3C), least squares, non-negative least squares, and maximum a posteriori fitting models. All models were evaluated on signal and parameter reconstruction accuracy and lesion contrast fidelity using data generated from subjects drawn from the University of Rochester COVID cohort. Results: PACE variants demonstrated lower RMSE for all IVIM parameters except for Dmv. The anatomy-weighted spatial prior further reduced RMSE across all five parameters relative to the default PACE, with modest reductions in lesion contrast accuracy for fmv and fint. For in-vivo evaluation, PACE with spatial prior also showed the best signal reconstruction across all noise levels while maintaining good to excellent ICC. Conclusion: Multimodal anatomical information improved IVIM fitting accuracy and robustness, with selective spatial integration via cross attention, gating, and anatomy-weighted spatial prior. Keywords: intravoxel incoherent motion, physics-informed deep learning, diffusion MRI, multimodality fusion, attention mechanism

Comment
34 pages, 8 figures, 2 tables, with 3 supplemental figures and 2 supplemental tables. Code will be available at https://github.com/gavtoski/PACE_IVIM after the publication date. For early code access, please contact Nhat Hoang at nhat_hoang@urmc.rochester.edu

Closest papers

Nearest neighbours by meaning across the whole index.

Learning Subject-Specific Anatomical Representations via Manifold Expansion: Application to Accelerated Multi-Contrast MRI

cs.CV cs.IR ·2026-10-02 ·Ruimin Feng, Wanyu Bian, Albert Jang, Zachary Stewart, Fang Liu
similarity 0.60
Abstract

Clinical MRI routinely acquires multiple contrast-weighted images of the same anatomy for complementary tissue characterization. However, current accelerated MRI methods typically reconstruct each contrast independently, without fully exploiting shared anatomical information. This work aims to learn anatomical representations invariant to contrast-dependent appearance for reconstruction of accelerated multi-contrast MRI. We propose MAX (MAnifold eXpansion), a subject-specific framework that learns anatomical representations from a single fully sampled reference contrast. To address the under-constrained separation of shared anatomy and contrast-dependent components from a single image, MAX expands the multi-contrast manifold using anatomy-preserving intensity augmentations. A disentangled implicit neural representation models augmented samples using shared spatial coordinates for anatomy and spatially invariant coordinates for contrast appearance. The learned anatomical representation is then fixed, with the contrast representation adapted to the undersampled target data, followed by unrolled refinement. Theoretical analyses further provide insight into the disentangled representation learning and explain how the learned anatomical representation improves the target contrast reconstruction. At R = 8 for brain MRI and R = 6 for knee MRI, MAX achieves the highest mean PSNR and SSIM across all tasks, improving PSNR by more than 1 dB over the strongest baseline for both brain contrasts. MAX more faithfully recovers subtle anatomical and pathological structures and remains robust to inter-contrast motion, structural heterogeneity between reference and target contrasts, and measurement noise. Therefore, MAX provides a general strategy for leveraging high-quality reference scans in accelerated MRI and has the potential to be extended to other reference-assisted MRI inverse problems.

0.12

MAGEFormer: Learning Metric-Consistent Representations for Anisotropic CT Segmentation

cs.CV cs.AI ·2026-10-02 ·Jiaying Li, Paolo Remagnino
top venue similarity 0.60
Abstract

Vision Transformers (ViTs) have shown strong performance in volumetric segmentation, but their effectiveness on clinical CT is limited by an isotropic Euclidean lattice assumption. This conflicts with anisotropic CT acquisition, leading to two key issues: (1) a metric mismatch between voxel indices and physical anatomy, and (2) accuracy degradation from isotropic resampling. To address this, we propose MAGEFormer, a geometry-calibrated framework that embeds physical metric constraints directly into representation learning. Our method introduces Metric-Adaptive Spatial Embedding (MASE) to calibrate positional frequencies using voxel spacing, Geometry-Constrained Attention (GCA) to suppress physically implausible feature correlations, and Geometric View Voting (GVV) to reduce discretization bias during inference. We evaluate MAGEFormer on two multi-organ abdominal CT benchmarks, BTCV and FLARE 22, under a unified protocol against strong CNN and Transformer-based baselines. MAGEFormer achieves the strongest boundary accuracy among the compared methods, with 10.58 mm HD95 on BTCV and 3.40 mm HD95 on FLARE 22, and shows consistent gains in Dice under the same protocol. These results show that geometry-aware internal calibration is more effective than relying on conventional isotropic preprocessing alone for anisotropic CT segmentation.

0.32

CNsEMD: An Expert-Annotated Multi-Field-Strength MRI Dataset and a Hyperspherical Manifold Network for Multimodal Cranial Nerve Parcellation

cs.CV ·2026-09-07 ·Lei Xie, Junxiong Huang, Guoqiang Xie, Jiawei Zhang, Jiahao Huang +7 more
benchmarkdataset similarity 0.58
Abstract

Cranial nerves (CNs) play essential roles in sensory, motor, and autonomic functions. Accurate CN parcellation from multimodal magnetic resonance imaging (MRI) is crucial for neuroanatomical analysis and neurosurgical planning. However, accurate CN parcellation remains extremely challenging because CNs are very small, exhibit low image contrast, and have slender tubular morphologies and complex anatomical trajectories. Moreover, the lack of publicly available, expert-annotated datasets has impeded the development and fair benchmarking of learning-based CN analysis methods. In this work, we introduce CNsEMD, an expert-annotated multimodal dataset for CN parcellation. It comprises data from 202 subjects acquired on 3T, 5T, and 7T MRI scanners. We further propose the projective hyperspherical manifold network (PHM-Net), which learns cross-modal representations by capturing angular relationships in a shared hyperspherical embedding space. Rather than performing multimodal fusion in Euclidean space, the proposed Hyperspherical cross-modal interaction (HCI) module enables bidirectional feature exchange between T1-weighted (T1w) and direction-encoded color (DEC) representations on a unit hypersphere. The Magnitude-preserving projective hyperspherical orientation representation (PHOR) captures the axial nature of DEC orientations while preserving diffusion magnitude. The hyperspherical prototype segmentation head (HPSH) further extends angular similarity to voxel-wise classification using normalized voxel embeddings and learnable class prototypes. Extensive experimental results on the CNsEMD dataset demonstrate the effectiveness of our PHM-Net against state-of-the-art methods. CNsEMD establishes a reproducible benchmark for multimodal CN imaging, while PHM-Net provides a geometry-consistent solution for CN parcellation across diverse MRI acquisitions.

0.16

Anatomy-Activated Mixture-of-Experts for 3D Medical Vision-Language Pre-training

cs.CV cs.AI ·2026-11-07 ·Szymon Płotka, Gizem Mert, Pedro R. A. S. Bassi, Wenxuan Li, Zongwei Zhou +7 more
publishedcode/data similarity 0.58
Abstract · NeurIPS 2026

Medical Vision-Language Pre-training (VLP) leverages the semantic richness of radiology reports to learn 3D representations, yet current architectures remain fundamentally anatomy-agnostic. While clinical diagnostics rely on organ-specific context, standard encoders apply a uniform, dense parameterization to all volumetric patches, and existing Mixture-of-Experts (MoE) routers gate on isolated local features without explicit access to the organ composition of the scan or crop. We propose Anatomy-Activated Mixture-of-Experts (A$^{2}$MoE), a framework that incorporates anatomical inductive biases within the model's computational path. A$^{2}$MoE introduces two key components: (1) a Histogram Representation Router (HRR) that conditions expert selection on global visual context and a predicted anatomical composition histogram, encouraging anatomy-dependent expert weighting; and (2) an Organ-Query Multi-Scale Projector (OQMSP) that utilizes learnable queries to extract organ-level embeddings for fine-grained alignment without requiring manual annotations at inference. By routing at the patch level rather than the token level, A$^{2}$MoE reduces routing complexity by orders of magnitude while satisfying load balancing by construction. Pre-trained on over 60,000 multi-phase CT scans, A$^{2}$MoE achieves state-of-the-art performance across segmentation, classification, and detection benchmarks. Furthermore, we demonstrate that our anatomically grounded inductive biases support robust generalization to MRI and ultrasound, establishing a scalable foundation for medical representation learning. The code is available at https://github.com/gmum/A2MoE.

0.41

MedGSSR: Generalizable Medical Image Super-Resolution 3D Reconstruction via Hierarchical Feed-forward Gaussian Splatting

eess.IV cs.CEcs.CVq-bio.QM ·2026-09-06 ·Chengkai Wang, Luoyu Hong, Yiting Zhao, Jiamin Wang, Xiang Feng +5 more
top venue similarity 0.57
Abstract · ECCV 2026

High-resolution volumetric medical imaging is critical for clinical diagnosis, yet acquisition is often limited by scanner hardware, scan time, and for CT, radiation dose. Medical 3D Super-Resolution (Med3DSR) offers a computational alternative, but existing methods commonly rely on per-subject optimization, pretrained priors, or coordinate-based implicit representations, which compromise anatomical fidelity and limit efficiency. To address these limitations, we present MedGSSR, a fully end-to-end feed-forward framework that represents volumes as an explicit 3D Gaussian field for Med3DSR. Unlike coordinate-based implicit functions, our explicit 3D Gaussian representation naturally enhances signal continuity and local high-frequency fidelity. Specifically, MedGSSR explicitly decouples the reconstruction process into coarse-grained structural preservation and fine-grained textural refinement through the proposed Pyramid Anatomical Encoder and a Hierarchical Gaussian Projector. To support arbitrary-scale super-resolution, we introduce sub-voxel Gaussian decomposition and a Differentiable Gaussian Voxelizer that directly queries the continuous 3D intensity field, reducing discretization artifacts. Extensive experiments on MRI and CT benchmarks demonstrate that MedGSSR significantly outperforms state-of-the-art methods. Notably, our framework exhibits robust generalizability across unseen datasets without requiring per-subject optimization, enabling fast inference and high-fidelity volumetric super-resolution in practical clinical settings. Our project webpage, including code, is at https://william2ai.github.io/medgssr

0.66

Improving Clinical Target Volume Segmentation Accuracy using Anatomical Priors and Active Learning for the AGITG TOPGEAR Clinical Trial

cs.CV physics.med-ph ·2026-09-02 ·Phillip Chlap, Mark Lee, Trevor Leong, Matthew Field, Jason Dowling +9 more
similarity 0.57
Abstract

Training deep learning-based medical image segmentation models is challenging with limited curated datasets. For AGITG TOPGEAR, a gastric cancer trial, the Clinical Target Volume (CTV) is complex and defined by multiple anatomical landmarks, making upfront training data preparation difficult for an automated contour QA segmentation model. We investigate anatomical priors, derived from surrounding organ segmentations, to provide spatial context and improve TOPGEAR CTV segmentation accuracy. We also evaluate active learning, iteratively expanding the training dataset by selecting cases expected to improve performance. One hundred TOPGEAR CT scans were retrospectively analyzed. An initial set of 10 expert-contoured cases was used to train an nnU-Net model. TotalSegmentator generated a voxel-wise anatomical prior map from surrounding structures as an additional input channel. Active learning was simulated over four iterations, selecting cases by model uncertainty and segmentation performance. All models used five-fold cross-validation for an ensemble uncertainty measure. Evaluation used a hold-out testing set of 50 cases. The anatomical prior improved CTV segmentation accuracy, increasing mean Dice Similarity Coefficient (DSC) from 0.84 to 0.86. Active learning similarly improved performance to 0.86, with greatest benefit in the final round. Combining the anatomical prior with active learning achieved the highest accuracy, with a DSC of 0.87. Model uncertainty correlated with DSC, supporting its use in identifying suboptimal predictions and guiding active learning. Anatomical priors and active learning each improved CTV segmentation accuracy and generalizability, with their combination achieving the best performance, supporting integration into segmentation model development for automated contour QA in radiotherapy clinical trials.

0.16

Low-Rank Velocity Fields as a Structural Prior for Unsupervised 4D Medical Image Interpolation

cs.CV ·2026-08-25 ·Haojin Li, Hengzhuo Wang, Chang Liu, Zhiheng Ma, Heng Li +1 more
top venue similarity 0.57
Abstract · MICCAI 2026

Endpoint-only unsupervised 4D medical image interpolation synthesizes intermediate volumes from sparsely sampled sequences with only the start and end volumes available for training; however, this weakly constrained setting often yields intermediates with unstable boundaries and non-physiological motion, limiting interpretability and downstream analysis. We propose low-rank velocity fields as a structural prior, constraining motion to a structured Tucker low-rank velocity field space that decomposes motion into globally shared spatial bases and a compact sample-specific core, thereby encouraging spatially correlated, anatomy-consistent deformation while suppressing voxel-wise high-frequency artifacts. To capture global coordination and local non-rigid details, we model motion in a coarse-to-fine multi-scale scheme and compose scale-wise deformations at inference to synthesize volumes at arbitrary times. We further provide a theoretical analysis showing that, under Tucker parameterization, low-rank parameters control the smoothness energy of the velocity field, explaining why low-rank modeling promotes smoother motion. Experiments on ACDC and 4D-Lung demonstrate state-of-the-art performance, remaining competitive with methods trained with intermediate-frame supervision, and producing intermediates with improved structural coherence and more stable anatomical contours.

0.53

Dual-VaDE: Efficient and Robust Prototype Learning via Variational Dual-Domain Mixture Priors

cs.LG ·2026-11-03 ·Wugeng Zheng, Song Wang, Jian Wang
theory similarity 0.57
Abstract

In this paper, we propose Dual-VaDE, an unsupervised generative framework for learning interpretable anatomical prototypes from unlabeled medical images. In contrast to previous variational methods that rely on a single spatial latent code, which often entangles global geometry with local textures and fails to capture their cross-domain dependencies, Dual-VaDE introduces a dual-domain Gaussian mixture prior that explicitly couples spatial anatomy with phase-preserving Fourier spectral representations. We derive an exact, closed-form variational lower bound that fuses this joint prior into the decoder and optimizes the entire network end-to-end via an alternating EM formulation, avoiding heuristic two-stage clustering while ensuring superior training stability and robustness. Evaluated on OASIS-3 brain MRI, Dual-VaDE delivers substantially sharper and more plausible prototypes, achieves superior cluster separation with improvements of up to 94% over spatial-only baselines, exhibits markedly reduced variance across random seeds, and incurs negligible inference overhead (0.28 ms per image).

0.21