CS Paper Radar

Investigating the trackability of landmarks in NBI and WLI

Jonas Below, Piermarco Gerli, Anna Jötten, Dennis Eggert, Axelle Felicio-Briegel, Veronika Volgger, Christian Betz, Alexander Schlaefer

eess.IV cs.CV ·submitted 2026-10-23 11:29 UTC · v1

Abstract

Reliable visual tracking of anatomical landmarks in endoscopic video is a key prerequisite for computer-assisted interventions in laryngeal surgery. While Narrow Band Imaging (NBI) is clinically established for enhancing vascular contrast, its effect on automated tracking relative to conventional White Light Imaging (WLI) remains unexplored. We present a quantitative comparison of landmark trackability in NBI and WLI using a forward-backward error framework applied to 61 endoscopic videos from 39 patients. Two regions of interest are evaluated: the vocal folds (VF) and mucosa with a prominent vascular pattern (MPVP). We compare a classical feature-based tracker (CSRT) against learning-based point trackers (CoTracker3-Online and TrackOnR) across both modalities. NBI consistently reduced the forward-backward error in both regions, reaching statistical significance for the vocal folds, while failure rates stayed low. These findings indicate that NBI can improve tracking robustness in laryngeal endoscopy, with implications for motion analysis, navigation, and robotic assistance.

Comment
Accecpted at CURAC conference 2026

Closest papers

Nearest neighbours by meaning across the whole index.

Beyond Region Memory: Local Point Tracking for Vocal Cord Localization in Video Laryngoscopy

cs.CV ·2026-10-28 ·Huayu Wang, Gyungmin Ko, Jung Heon Kim, Jia-Xian Jian, Dae Kon Kim +7 more
published similarity 0.67
Abstract · Accepted by WACV 2027

Reliable vocal-cord localization in emergency video laryngoscopy remains visually challenging due to rapid tissue deformation, specular highlights, and instrument occlusions. We propose Local Point Tracking (LPT), a robust framework that combines a single-frame detector, local point propagation, and stateless mask refinement. LPT follows a localize first, snap second pipeline. First, a single-frame semantic detector generates sparse anchors, within which LPT initializes local query points (SAM-supported by default, with a regular grid as fallback). A point-propagation module tracks these points through detector-missed frames and recovers temporal bounding boxes from their geometry. Second, because point-derived boxes can be loose around the visible boundary, a box-snap step refines the selected box to the target boundary. This decomposition keeps temporal state in local point coordinates rather than a stateful mask or whole-region representation, while the spatial refinement module handles single-frame boundary precision without feeding mask errors back into temporal memory. Extensive evaluations on two distinct datasets demonstrate that our proposed LPT method achieves strong overall performance against existing baselines, with the best mAP_50, success AUC, and missing rate on both datasets. Furthermore, ablation studies confirm that point tracking primarily enhances temporal tracking robustness, while box-snap refinement effectively improves boundary tightness.

0.40

S3-Tracker: Self-Supervised Surgical Tissue Tracking With Contrastive Random Walks

cs.CV cs.LGcs.RO ·2026-09-13 ·Jiaming Zhang, Zijian Wu, Mehran Armand, Septimiu Salcudean
published similarity 0.63
Abstract

Robust point tracking in endoscopic videos is essential for computer-assisted intervention and autonomous robotic surgery, enabling continuous registration between intraoperative video and preoperative imaging despite soft tissue deformation. However, supervised tracking methods depend on large annotated datasets, while surgical conditions make reliable trajectory annotation challenging. We propose a self-supervised Track-Any-Point approach that learns from unlabeled surgical videos by establishing global pixel correspondences and inferring point trajectories through contrastive random walks. Trained without annotations, our method achieves performance comparable to existing semi-supervised approaches while implicitly handling tissue deformation. These findings demonstrate the feasibility of self-supervised point tracking in surgical environments and its potential to reduce reliance on annotated data.

0.22

STEP: Surgical Point Tracking from Sparse Endpoints and Pseudo-trajectories

cs.CV ·2026-10-22 ·Bing Fan, Anwesa Choudhuri, Zhongpai Gao, Meng Zheng, Benjamin Planche +3 more
similarity 0.61
Abstract

Surgical point tracking requires persistent correspondence through tissue deformation and occlusion, yet dense trajectory annotations are costly to obtain. We present STEP, a two-stage framework that learns from surgical video and sparse physical endpoints. First, a frozen offline teacher generates candidate trajectories, and temporal reversibility and stereo consistency select dense supervision for a causal student. Second, a robust physical endpoint loss anchors terminal correspondence, while a round-trip loss constrains temporal consistency. A gradient-free prefix exposes training to accumulated drift, while a final differentiable window bounds activation memory. The trained tracker processes a single RGB stream with fixed weights. In STIR-to-VL-SurgPT transfer, temporal-stereo union selection reduces endpoint error by 7.0% relative to unfiltered trajectories. On a post-hoc diagnostic of 29 VL-SurgPT clips excluded from the endpoint-training manifest, STEP reduces endpoint error from 31.52 to 16.80 pixels relative to dense-label fine-tuning. These results support combining curated trajectories with physical observations to train surgical point trackers.

0.17

PADSNet: Physics-Aware Dual-Stream Network with Biomechanical Priors for Laryngeal Lesion Classification

cs.CV ·2026-11-13 ·Zhenzhen You, Weifeng Yu, Zhenghao Shi, Shuangli Du, Minghua Zhao +5 more
similarity 0.59
Abstract

Precise classification of laryngeal lesions is clinically crucial yet highly challenging, as inter-class visual differences are often subtle. While abnormalities in vocal fold vibratory dynamics provide complementary discriminative information, existing deep learning models predominantly rely on visual appearance and lack explicit mechanisms for modeling clinically meaningful vibratory dynamics. To address this, we propose PADSNet, a Physics-Aware Dual-Stream Network for laryngeal lesion classification that integrates visual representations with explicit biomechanical reasoning. Specifically, a Wavelet-Attention Enhancement Module (WAEM) is designed to bridge the spectral-semantic gap, enabling complementary learning of spatial texture and dynamic frequency representations. Meanwhile, a Knowledge Computing Module (KCM) extracts interpretable biomechanical indices from temporal glottal distance waveforms, including indicators of mobility, symmetry, glottal closure, and vibration stability. These descriptors are subsequently incorporated into a Physics-Aware Gating Module (PAGM) as biomechanical priors to adaptively recalibrate visual feature toward pathology-relevant vibratory patterns. Extensive experiments on a clinical dataset demonstrate that PADSNet achieves an accuracy of 0.8452, an F1-score of 0.8090, a sensitivity of 0.7953, and a specificity of 0.8866. These results indicate that explicitly integrating biomechanical priors with deep visual representations provides a more accurate, robust, and clinically interpretable framework for automated laryngeal lesion classification.

0.21

RAUL: Reference-Assisted Ureteroscopy Localization for Skill Assessment

cs.CV ·2026-09-16 ·Fangjie Li, Mai Bui, Charan Mohan, Michael Miga, Matthieu Chabanas +2 more
hot direction similarity 0.59
Abstract

Objective: Incomplete navigation of anatomy during ureteroscopic kidney stone surgeries can contribute to repeat interventions. While skilled surgeons have lower reintervention rates, there are no objective metrics to quantify scope-navigation performance to evaluate when a trainee becomes skilled. This work aims to recover ureteroscope trajectories from endoscopic video and derive navigation metrics to quantify differences in skill. Methods: We propose RAUL, a reference-assisted reconstruction framework for recovering ureteroscope trajectories from ureteroscope videos only in phantoms. For each phantom, we use a slow, high-quality reference exploration video to generate a reference reconstruction. We localize subsequent exploration videos against this reference. We evaluate localization accuracy against electromagnetically tracked scope pose. We compute navigation metrics from phantom exploration trajectories to compare surgical residents across experience levels. Results: The proposed reference-assisted framework achieves a mean translation root mean square error of $0.5 \pm 0.1$ mm across 9 phantoms. Compared to standard Structure-from-Motion (SfM), the proposed pipeline increases frame-wise localization coverage from $50.5 \pm 14.9\%$ to $86.1 \pm 7.2\%$ of all video frames. The reconstructed trajectories revealed significant differences between high- and low-experience trainees in established navigation metrics. Conclusion: RAUL enables substantially more complete recovery of ureteroscope trajectories from videos compared to standard SfM pipelines, enabling trajectory-based skill assessment without additional tracking equipment. Significance: To the best of our knowledge, this is the first use of video-only recovery of ureteroscope trajectories without external tracking sensors for skill assessment, supporting scalable automated assessment of ureteroscopy navigation skill.

0.38

Structure-aware Keypoint Localization for Videofluoroscopic Swallowing Study

cs.CV ·2026-10-06 ·Kai Zhou, Chuanshen Chen, Runhao Zeng, Meng Dai, Yifan Yang +4 more
publisheddatasetcode/data similarity 0.58
Abstract · Accepted by ICME 2026 Oral

Videofluoroscopic Swallowing Study (VFSS) is one of the gold standard for diagnosing swallowing disorders, providing dynamic X-ray imaging of the swallowing process. Automated kinematic analysis in VFSS relies fundamentally on precise anatomical keypoint localization. However, existing studies focus on limited keypoints (e.g., cervical vertebrae or the hyoid) and overlook critical regions such as the soft palate, while annotating only active swallowing segments and ignoring abundant non-swallowing data, resulting in poor data efficiency. Moreover, leveraging this unlabeled data via standard semi-supervised learning is suboptimal, as generic methods are prone to spatial bias. In medical X-rays with fixed layouts, models tend to memorize absolute coordinates rather than understanding anatomical structures. To tackle these challenges, we introduce VFSSKep, a novel dataset that extends annotations to the soft palate and incorporates large-scale unlabeled data. We further propose S$^3$KL, a Structure-aware Semi-Supervised Keypoint Localization framework designed to overcome spatial bias. It integrates a Structure-Aware Learning strategy to extract high-resolution structural cues for structure-aware representation learning, and a Structural Representation Consistency Learning strategy with block shuffling to enforce invariant structural recognition. Experiments show our method achieves state-of-the-art semi-supervised performance, even with unlabeled and 25% labeled data surpassing fully supervised learning with 100% labeled data. Code and data will be made publicly available at: https://github.com/kaai520/S3KL.

0.42

Evaluating Transformation Models for pCLE Mosaic Registration

cs.CV ·2026-09-21 ·Ahmed Aboelela, Johannes Barcsay, Jana Friedhof, Miguel Gonçalves, Alexander Hann +1 more
similarity 0.58
Abstract

Confocal Laser Endomicroscopy (CLE) provides real-time, cellular-resolution optical biopsy but has a narrow field of view, which image mosaicing can extend to provide anatomical context. Because of line-by-line acquisition, probe motion, and probe-tissue interaction, frame alignment generally requires a non-linear transformation whose accuracy is difficult to quantify: flexible transformation models can fit intensity features and noise, so appearance-based metrics such as Normalized Cross-Correlation (NCC) can improve without a genuine gain in geometric accuracy. We therefore establish a dataset of 132 frame pairs across fourteen pCLE sequences from 4 patients with manually annotated landmark correspondences, so that Target Registration Error (TRE) can serve as a geometrically grounded complement to NCC. We assess the effect of progressively increasing the transformation model's degrees of freedom, from translation to Thin Plate Spline (TPS), and of six feature-matching backends spanning classical (Shi-Tomasi, Lucas-Kanade) and learned (SuperPoint, SuperGlue, LightGlue, LoFTR, RoMa) approaches. Translation and rigid models prove insufficient under tissue deformation, while TPS with random sampling achieves the strongest landmark-derived alignment of the evaluated configurations; among the learned matchers, used without fine-tuning, only RoMa offers a robust, if modest, advantage over other methods. At the sequence level, pairwise registration quality proved an unreliable predictor of final mosaic quality, so mosaic quality must be evaluated directly rather than inferred from pairwise metrics.

0.34

SCOPE-4D: Endoscopic 4D Geometry Foundation Models

cs.CV ·2026-10-01 ·Chaoyi Zhou, Zhongpai Gao, Anwesa Choudhuri, Meng Zheng, Benjamin Planche +4 more
code/data similarity 0.57
Abstract · Project page: https://chaoyizh.github.io/SCOPE-4D-page/

Geometric understanding supports endoscopic navigation and robotic assistance, but learning reliable endoscopic geometry faces two challenges: scarce geometric annotations and ambiguity between camera motion and tissue deformation. We present SCOPE-4D, an endoscopic 4D geometry foundation model that jointly predicts camera parameters, dense geometry, and 3D tissue trajectories from monocular RGB video in a single forward pass. Our curation and annotation pipeline constructs SCOPE-5K, a collection of approximately 5,000 clips spanning real and synthetic gastrointestinal endoscopy and laparoscopy. The collection provides rich geometric supervision and includes newly collected phantom and real-colonoscopy evaluation sets. Geometric supervised fine-tuning on SCOPE-5K learns endoscopic priors that improve camera and depth estimation. Common--Residual Motion (CRM) further constrains local deformation relative to common tissue movement. Together with geometric supervision, CRM and trajectory supervision further improve camera and depth estimation over geometric fine-tuning alone while enabling dense 3D tissue tracking. Evaluations on public and newly collected benchmarks demonstrate strong in-domain and out-of-domain geometry, superior 3D tracking, and more stable long-sequence colon reconstruction. A blinded user study further supports the perceived reconstruction quality on real clinical video. Together, these results demonstrate the value of large-scale endoscopic supervision and motion constraints for joint geometry estimation and tissue tracking.

0.21