CS Paper Radar

Tracking Is Not Sensing: Artifact-Aware Thermal Video Respiration Estimation in Head-Free Marmosets

Penghao Wang, Sen Yang, Fenghua Xie, He Wang, Xindong Song

cs.CV ·submitted 2026-10-24 13:18 UTC · v1
published

Abstract

Continuous physiological monitoring is essential for linking behavior, internal state, and neural activity in neuroscience and translational research. In common marmosets, a key nonhuman primate model for social neuroscience, respiratory rate provides a basic readout of arousal, stress, and physiological regulation. Contact sensors can provide accurate measurements, but they add preparation burden and may interfere with head-free behavioral protocols. Thermal video offers a noncontact alternative by capturing breathing-related temperature changes around the nose and mouth. However, in head-free marmosets, these cues are weak, localized, and easily corrupted by head motion, pose changes, and fur. Here we show that this setting exposes a broader challenge in video-based physiological sensing: visually reliable tracking does not necessarily imply physiologically valid measurement. Using synchronized thermal video and contact respiration recordings, we show that marmoset respiration is recoverable from thermal video but strongly ROI-sensitive. Under head-free motion, visually plausible nasal tracking can still produce traces inconsistent with contact respiration, demonstrating that tracking is not sensing. We therefore estimate respiratory rate from learned temporal signals extracted from thermal clips and introduce Selective Temporal Attenuation Regularization (STAR). STAR selectively attenuates high-motion thermal discontinuities through local temporal imputation during training, regularizing models toward respiration-consistent dynamics while leaving inference unchanged on raw video. Across multiple deep-learning backbones, STAR improves head-free estimation, reaching 2.23 bpm MAE compared with 20.76 bpm for tracked ROI analysis.

Comment
WACV 2027

Closest papers

Nearest neighbours by meaning across the whole index.

Subject-Relative Micro-Motion and Sleep Dynamics for Near-Infrared Video Sleep Staging

cs.CV cs.AI ·2026-09-03 ·Kunmin Jang, You Rim Choi, Hun Heo, Heonjun Lee, Suahn Bae +3 more
similarity 0.64
Abstract

Near-infrared (NIR) video is a promising modality for contactless sleep monitoring, but recent video-based sleep staging methods often use it as a route to reconstructed respiratory/cardiac proxies or cross-modal physiological representations. We study video-only sleep staging under labels defined by polysomnography (PSG), where the model infers sleep stages from NIR video alone without explicit physiological proxy reconstruction or auxiliary physiological signal supervision. This tests whether NIR video itself can provide informative sleep-stage evidence, rather than only serving as an input for recovering physiological proxies. We propose ViNUSS (Video-Native Unmediated Sleep Staging), a framework that combines subject-relative micro-motion learning with full-night sleep dynamics modeling. Spatially anchored pre-spatial micro-motion encoding preserves localized temporal variation together with its spatial context. Within-subject stage contrast learns stage cues with respect to each subject's night-specific baseline. Two-scale sleep dynamics modeling captures within-epoch motion evolution and organizes epoch-level evidence into a coherent full-night sleep-stage trajectory. On 475 overnight NIR recordings (~3,250 hours), ViNUSS achieves 0.80 accuracy and 0.78 macro-F1 for four-class sleep staging. Interpretability analysis suggests attention to thoraco-abdominal periodic motion and gross body movements associated with arousals and position changes. These results support NIR video as an independently informative and complementary modality for PSG-defined sleep-stage estimation

0.19

EgoHRV: Continuous Heart Rate Variability Estimation from Egocentric Systems for Autonomic Response and Skill Assessment

cs.CV eess.SP ·2026-08-19 ·Berken Utku Demirel, Christian Holz
top venuecode/data similarity 0.63
Abstract · Accepted to the European Conference on Computer Vision (ECCV) 2026

Egocentric vision systems capture human behavior from visible cues, but overlook physiological indicators of autonomic states such as stress, engagement, and attention. Heart rate variability (HRV) is a widely used noninvasive marker of autonomic regulation under stress. HRV reflects small timing differences between successive heartbeats and has so far been out of reach for egocentric platforms, where motion and noise in gaze video mask exactly this fine-grained timing. We propose EgoHRV, a method that estimates HRV as well as heart rate (HR) from the gaze cameras that are already integrated into egocentric headsets. Our pipeline combines a 3D backbone with a novel low--high decomposition module that extracts the blood volume pulse (BVP) signal from gaze video. Our cross-domain pretraining aligns the frequency-domain representations of contact-based and camera-derived signals. This alignment gives EgoHRV the temporal precision to recover HRV from the subtle fluctuations in gaze video. EgoHRV achieves state-of-the-art accuracy for HR and HRV estimation from egocentric video, and its uncertainty-aware design improves downstream behavioral modeling. Integrating our HRV estimates and confidence measures into EgoExo4D's proficiency estimator raises accuracy by 17.8%. Beyond skill, continuous HRV estimation also opens egocentric systems to stress- and arousal-aware estimation tasks. Code: https://github.com/eth-siplab/EgoHRV

0.48

Calmables: Demonstrating Closed-Loop Infrared Earables for Thermal Biofeedback and Relaxation Support

cs.HC ·2026-09-16 ·Valeria Zitz, Michael Küttner, Jonas Hummel, Taku Inoue, Tobias Rödiger +1 more
published similarity 0.63
Abstract

We present Calmables, a walk-up demo of a closed-loop infrared earable that uses smart-ring heart rate to create subtle, ear-localized warming cues. Building on work on thermal comfort and in-ear infrared stimulation, Calmables explores warmth at the ear as a biosignal-adaptive cue for brief recovery moments following acute activation. A smartphone first establishes an individual resting baseline and derives a personalized heart-rate threshold, while the earable controller independently enforces an over-temperature cut-off and communication fail-safes. During the guided demo flow, attendees complete a brief rapid-breathing activation phase until their heart rate reaches the personalized threshold. This triggers an ear-localized warming cue followed by a short relaxation phase, while physiological changes are displayed on a live dashboard. Attendees can also manually explore different infrared stimulation intensities. To contextualize the demo, we report preliminary placebo-controlled UX ratings from 18 participants: participants rated the active prototype higher on perceived relaxation and perceived recovery support than an identical-looking placebo. Together, the demo illustrates how infrared earables can make physiological feedback tangible through subtle, biosignal-adaptive thermal cues.

0.59

emg2face: Expressive Facial Animation with High-Density Surface EMG

cs.GR cs.CVcs.ETcs.LG ·2026-10-07 ·Ganidhu Abey, Wendy Greening, Ashika Kamboj, Leonhard Helminger, Abhijeet Ghosh +3 more
similarity 0.58
Abstract · 12 pages plus supplmentary material

Facial movements convey subtle and important information that is critical for human social communication. Optical methods for face capture are difficult or impossible to use when the face is occluded by head-mounted devices (HMDs), such as VR headsets. Even with a clear line of sight, such methods raise privacy concerns and require head-mounted capture rigs that offset cameras and lighting from the face. We show that high-density surface electromyography (HD-sEMG) provides a viable non-optical alternative that addresses these challenges. We measured 64 EMG channels, using two textile EMG grids, with 32 from the forehead (typically occluded by an HMD) and 32 from the side of the face. EMG data were digitized at 2048 Hz and filtered. Facial movements were simultaneously recorded and used to estimate 478 3D facial landmarks using MediaPipe's Face Landmarker. A major challenge in such multimodal recordings is synchronizing EMG and video data, which have different sampling frequencies and independent clocks. We developed a novel synchronization method using analog audio bursts that is capable of sub-millisecond synchronization. We also developed a staged fitting method that fits a recent high-resolution parametric head model (GNM), with 253 identity blendshapes and 383 expression blendshapes, to the MediaPipe landmarks as participants performed different facial expressions. We trained a deep neural network comprising per-grid spatial encoders followed by a dilated temporal convolutional network (TCN) to predict blendshape parameters from HD-sEMG signals at 100 Hz. Once trained, the network can predict expression blendshapes solely from HD-sEMG recordings. The output can be rendered using standard real-time blendshape animation methods. We demonstrate the methods using recordings from 25 participants, and direct expression transfer to a variety of human faces and non-human characters.

0.25

Towards Privacy-Preserving Thermal Human Perception from Dataset to Deployment

cs.CV eess.SP ·2026-10-10 ·Kailai Sun, Yue Cui, Xinwei Wang, Zijie Gao, Baoshen Guo +6 more
code/datahot direction similarity 0.56
Abstract

Indoor human perception is the foundation for smart homes and healthcare. However, RGB cameras raise privacy concerns in private indoor environments, while low-resolution thermal cameras provide limited spatial and semantic information. Large-scale indoor thermal datasets and real-world deployments remain limited. Here, we introduce Indoor RGB-T, a large-scale paired RGB--thermal dataset for indoor human perception. The dataset covers 20 indoor rooms and contains 90,576 80x62 thermal frames, 87,016 temporally matched RGB--thermal pairs, and 115,557 annotated human bounding boxes. We establish benchmarks for robust thermal occupant-state detection with 0.75 mAP and occupancy estimation with an accuracy of 0.847 in unseen rooms. We further evaluate RGB-to-thermal and thermal-to-RGB translation, achieving a temperature MAE of 0.654 C and an R2 of 0.923. Finally, we deploy the thermal perception model on a commercial sleep-monitoring system in the real world. Field testing with 100 participants and deployment of approximately 1,000 devices further demonstrate its practical feasibility. We identify practical challenges that motivate future research directions, including environmental thermal interference, sensing range and multi-person occlusion. The code, trained models and partial dataset are available at https://github.com/kailaisun/RGBT and https://huggingface.co/skl24/RGBT.

0.41

Acoustic Respiratory Phase Detection on Mobile Devices

cs.AI cs.LG ·2026-11-12 ·Julian Szymanski, Tomasz Sankowski, Piotr Sulewski, Iwo Czartowski, Javier Medina Quero
similarity 0.55
Abstract

Breathing monitoring is important for well-being, stress regulation, and guided breathing exercises, yet existing approaches often rely on contact-based sensors or controlled environments. This paper presents a non-invasive framework for respiratory phase detection using acoustic signals recorded on commodity smartphones. The proposed hybrid CNN-Transformer architecture combines local spectral feature extraction with long-range temporal modeling to capture the cyclic structure of breathing. The model is evaluated using a Leave-One-Subject-Out (LOSO) protocol on the Foundation Dataset and on an independent unseen test set comprising over 1300 breathing cycles and 2 hours of continuous recordings. The proposed 3-class formulation achieves 72.85% frame-level accuracy and 96.6% cycle-level exhalation detection efficiency in the LOSO evaluation, while achieving 76.94% frame-level accuracy, a Cohen's Kappa score of 0.65, and 99.2% cycle-level exhalation detection efficiency on the unseen test set. Results suggest that accurate respiratory monitoring may be achievable under data-constrained conditions, indicating that appropriate temporal modeling can learn transferable respiratory representations and generalize to previously unseen participants. An end-to-end ONNX deployment pipeline enables privacy-preserving on-device inference with latency below 20 ms, supporting real-time monitoring on mobile and wearable devices.

0.14

PhysVR: Vision-Language Model Guided Interference-aware Temporal Feature Refinement for Remote Physiological Measurement

cs.CV ·2026-08-30 ·Zixu Li, Jianjun Qian, Hang Shao, Daoheng Li, Lei Luo +1 more
similarity 0.55
Abstract

Remote photoplethysmography (rPPG) enables contactless physiological measurement from facial videos, yet its subtle pulse-related variations are easily affected by illumination variation, head motion, facial blur, and region-of-interest instability. Existing methods mainly suppress interference during feature learning, while whether the learned temporal features remain affected by interference and how to further suppress such interference before rPPG estimation are rarely examined. To address this limitation, we propose PhysVR, a vision-language model guided interference-aware temporal feature refinement framework for rPPG estimation. Specifically, a physiological backbone produces global temporal features and a coarse rPPG prediction, from which signal-derived physiological reliability evidence is constructed from local temporal characteristics. In parallel, a frozen vision-language model processes sampled facial frames under an interference-oriented prompt, and an evidence head extracts visual interference evidence from the VLM output. Temporal cross-attention integrates the physiological and visual evidence with the global temporal features to construct interference-aware temporal context. Guided by this context, a shared temporal correction unit performs general refinement, while four interference-specific experts selectively suppress different interference through adaptive routing. The refined temporal features are then used for final rPPG estimation. Extensive experiments on five public benchmarks demonstrate that PhysVR consistently outperforms representative methods under both intra-dataset and cross-dataset evaluation protocols.

0.29

PRISM: Profiling and Representation of Individual Stereotypical Motion

cs.CV ·2026-11-18 ·Austin A. MBaye, Savik Kinger, Matthew S. Goodwin
similarity 0.55
Abstract

An anatomical pose provides interpretable joint structure, but no fixed set of physical landmarks can fully specify a person's movement. We introduce PRISM, a complementary representation that characterizes repetitive movement using tracked masks and dense optical flow. Torso-relative flow measures intensity, frame-wise mask variation measures spatial extent, signed-flow recurrence estimates frequency, and persistent sliding-window geometry describes the rhythmicity of the movement. Across 1,890 synthetic conditions, the measurements recover controlled speed, amplitude, and frequency while exposing observation limits. An idealized hand-motion experiment demonstrates variation omitted by identical exact COCO-17 trajectories; controlled corruption experiments separately examine measurement sensitivity. Audits of two pose methods on the same data cohort and 36,930 external skeleton clips document incomplete observation and dependence on processing choices. In 1,404 annotated complex stereotypical motor movement bouts from six autistic participants, total flow converges with pose motion, while matched-coordinate examples and repeated-session profiles show differences in intensity, extent, frequency, and rhythmicity within behavior labels. A separate VLM comparison evaluates quantitative frequency estimation, and a profile-conditioned decoder links the measurements to illustrative skeletal movements. PRISM connects numerical profiles to visible examples, providing an interpretable way to compare how the same behavior is expressed beyond its label or event count.

0.35