CS Paper Radar

EXCISE: Locating and Excising Distracting Sentences in Medical Question Answering

Yerim Hong, Sohyun Son, Heeseung Chung, Mujeen Sung

cs.CL ·submitted 2026-10-26 14:59 UTC · v1
benchmark

Abstract

Language models are increasingly considered for clinical decision support, where their answers should be grounded in clinical evidence and remain robust to irrelevant information. Prior work shows that a single irrelevant sentence can lower the accuracy of medical models, but not where inside the model its effect can be removed, or how to do so without knowing which sentence it is. We find that blocking attention to a known distractor restores the answer, whereas head masking can suppress correct answers. We also show that the model's hidden states mark the distractor as the sentence that least fits the case even when the model follows it. To remove a distractor's effect without knowing which sentence it is, we propose EXCISE, an inference-time method that blocks the sentence most influencing the answer, but only if the model's hidden states mark it as inconsistent with the case. On MedQA-TD (MedQA with Targeted Distractors), a benchmark we construct in which each distractor targets a specific wrong option, EXCISE gains 16.7-22.8 accuracy points at a 1.5-2.1-point cost on the same questions without distractors, outperforming prompting, rewriting, and steering baselines for all three models. Its gains extend to MedDistractQA and BiasMedQA, as well as chain-of-thought generation.

Closest papers

Nearest neighbours by meaning across the whole index.

Untangling the Mechanisms of Misleading Context in Medical Question Answering

cs.CL cs.AIcs.LG ·2026-09-02 ·Robin Linzmayer, Noémie Elhadad
benchmark similarity 0.65
Abstract · 25 pages, 10 figures. Submitted to ML4H 2026

Large language models now answer medical questions with expert-level performance. However, the context these systems act on can be misleading, and misleading context can corrupt a model's medical judgment. To understand how misleading context corrupts this judgment, we examine the model's susceptibility to the context, disclosure of it, mechanism of corrupted reasoning, and monitorability of the decision. On the medical reasoning subset of MedMisBench, a clinician-reviewed question-answering benchmark of 8,627 questions, we inject two types of misleading context cues, fabricated evidence and a bare assertion. We test three reasoning models, two that expose their full reasoning trace and one frontier model that exposes only its response. All three are more susceptible to the assertion than to the fabricated evidence, adopting the asserted answer 10 to 27 points more often. The misleading cues are disclosed in 81 to 98% of traces but only 7 to 90% of responses, and the assertion is disclosed less often than evidence based cues. Resampling from reasoning traces without disclosure shows the two cues corrupt reasoning differently, evidence entering early and accumulating while the assertion redirects the conclusion near its end. An LLM monitor catches 78% of corrupted decisions at 5% false positives when reading an open model's trace with guidance, against at most 32% from any response. The misleading context that models are most susceptible to is disclosed least, and was caught reliably only from an open reasoning trace, which frontier providers withhold.

0.21

When to Stop Asking: Factor Coverage Bias and LLM Determinability Judgments with Underspecified Information in Medicine

cs.AI ·2026-10-19 ·Yusuke Watanabe, Yohei Kobashi, Taisei Tosaki, Takeshi Kojima, Yusuke Iwasawa +2 more
benchmark similarity 0.62
Abstract · 17 pages, 8 figures, 8 tables

Clinical decision-making often begins with underspecified information and requires not only gathering missing information but also knowing when to stop. This calls for judging determinability (whether the available information is sufficient for a decision) by considering whether missing information could change the conclusion, not simply the amount of available decision-relevant information. Reliance on this amount as a cue for determinability, which we term \textit{factor coverage bias}, could undermine the trustworthiness of large language models (LLMs) through premature conclusions or excessive information gathering, such as unnecessary invasive tests. Yet whether LLMs exhibit this bias remains insufficiently studied. To address this gap, we construct a controlled pairwise benchmark in which LLMs identify the determinable case within each determinable--undeterminable pair. We add a decision-relevant factor to either side while keeping each case's determinability unchanged, and similarly add irrelevant text to distinguish this bias from context-length effects. Adding a relevant factor made LLMs more likely to select the augmented case as determinable even when it remained undeterminable, an effect that persisted with increased reasoning effort, while adding irrelevant text made them less likely to select the augmented case, an effect that reasoning substantially reduced. These findings identify factor coverage bias as a failure mode distinct from context-length effects and a potential risk to LLM trustworthiness. Our work provides an evaluation framework for LLM trustworthiness under underspecification.

0.29

When Confidence Fails: Overconfidence in LLMs under Uncertainty and Missing Clinical Information

cs.CL cs.AIcs.HCcs.LG ·2026-08-10 ·Maryam Tahermazandarani, Adnan Mahmood, Fahmida Islam, Quan Z. Sheng
published similarity 0.61
Abstract

Large Language Models (LLMs) have achieved strong performance in medical question answering and clinical reasoning tasks. However, their reliability under uncertainty remains poorly understood which raises critical concerns for deployment in high-stakes clinical settings. In such environments, incorrect predictions are inherently risky, but confident incorrect predictions can be particularly harmful as they may mislead clinical decision-making. In this paper, we conduct a systematic behavioral analysis of LLMs under clinical information uncertainty. We propose an evaluation framework based on the MedMCQA dataset consisting of two complementary uncertainty settings. First, we introduce linguistic uncertainty cues through prompt modifications to simulate ambiguous clinical contexts. Second, we construct an answer removal setting, wherein the correct option is deliberately excluded mandating the model to recognize insufficient information and abstain. We analyze both model accuracy and confidence behavior using multiple calibration metrics including calibration gap, Expected Calibration Error (ECE), and Unsafe Confident Error Rate (UCER) across 500 medical questions. Our results reveal a consistent failure mode, i.e., although accuracy degrades under increasing uncertainty, model confidence remains misaligned with accuracy. This leads to a substantial increase in unsafe confident errors, indicating that model confidence remains largely insensitive to clinically meaningful information loss. Furthermore, we observe significant variation across models in their ability to abstain when the correct answer is unavailable, with some models persistently producing high confidence hallucinated answers. These findings expose critical limitations in the epistemic reliability of current LLMs and highlight the need for uncertainty aware evaluation methods prior to their deployment in clinical workflows.

0.22

MUDDLE: Measuring Understanding of Documents under Distractor and Length Effects

cs.CL cs.AI ·2026-08-30 ·Jason Luo, Saibilila Abudukelimu, Judy Song, Andrew Feng, Shivank Garg +2 more
benchmarkcode/data similarity 0.61
Abstract · 12 pages. Accepted to the Context Beyond the Window (CBW) workshop at COLM 2026 (non-archival). Code and data: https://github.com/luoojason/…

Document question-answering systems increasingly answer questions over collections of retrieved documents rather than one clean source, so robustness to distracting context matters as much as reading ability. When such systems fail, it is often unclear whether the context was too long or the distractors were too close to the topic, because prior work tends to conflate these two effects. We present MUDDLE, a controlled benchmark that separates them. MUDDLE uses 270 human-annotated questions, each tied to a single source document, and instantiates every question in five conditions: the source alone, the source with two or four topically similar hard negatives, and the source with two or four random distractors. The random distractors are matched to the hard negatives in length and provenance, so an accuracy gap between the two arms reflects topical similarity rather than length. All five conditions are rendered in markdown, page images, and raw PDF, but the distractor sweep reported here is run in markdown, since a source plus its distractors exceeds current image and PDF input limits. We score answers with an LLM judge across three model families. In the complete markdown sweep, hard negatives lower accuracy more than length-matched random documents at both context sizes for gpt-5-mini, while random documents stay near the no-distractor baseline. The effect is small but directionally consistent, and for gpt-5-mini hard negatives significantly underperform length-matched random distractors when pooled across context sizes. We release the data and evaluation code for a reproducible study of context degradation.

0.69

Back to the Question: Tracing Visual Distraction Through Text Tokens

cs.CV ·2026-11-11 ·Marie Amale Huynh, Regev Cohen, Serena Yeung-Levy, Sivan Doveh
similarity 0.61
Abstract · 25 pages, 18 figures, including appendix

The visual world is cluttered: robust vision-language reasoning requires ignoring irrelevant information. Yet vision-language models (VLMs) can suffer substantial accuracy losses when answering questions about a target image with distractors present. Existing mitigations focus on selecting relevant images or limiting information exchange between images. Through a systematic analysis of three open 7-8B VLMs on five perception benchmarks adapted to include distractor images, we show that distractors reduce accuracy even when models correctly identify the relevant image, suggesting that selection alone is not enough. To understand the mechanism behind this interference, we combine attention analysis with targeted knockouts in Qwen2.5-VL and identify middle-layer distractor-to-text connections as a pathway through which irrelevant visual information affects reasoning. We introduce answer consistency regularization, which encourages consistent answer distributions with and without distractors. Without directly constraining attention, this objective reduces middle-layer attention from question tokens to distractor images, consistent with the pathway our analysis implicates. With five distractors, our approach improves circular accuracy by an average of 16 percentage points over the Qwen2.5-VL baseline across the five benchmarks while preserving single-image performance.

0.16

From Small to Large: Assessing Medical Reasoning, Benchmark Contamination, and Model Size in Language Models

cs.AI cs.CL ·2026-10-30 ·Navapat Nananukul, Mayank Kejriwal
benchmark similarity 0.60
Abstract

Large language models (LLMs) now answer medical exam questions at or above expert level, but it is unclear whether such scores reflect clinical competence, or are instead affected by the format of the questions being asked (e.g., multiple-choice versus open-ended), prior exposure to the benchmarks, and the difficulty of the questions. These benchmarks are also public and widely used online, which may be resulting in LLM memorization. Models may perform better on questions that they have seen before. It is also not evident whether smaller models, which are more locally deployable in HIPAA-compliant hospital settings, have achieved human performance. In this study, we evaluate fourteen current models from six leading providers, one smaller and one larger model from each provider with two additional open-weight models, on 3,076 questions from four medical benchmarks (MedQA-USMLE, MedMCQA, PubMedQA, and MedBullets) under standard multiple choice, the same questions with the answer choices withheld, and reconstruction of a hidden question from its choices alone. In the standard multiple-choice setting, the strongest models exceed the human-expert baseline on MedQA-USMLE and PubMedQA, but the smaller models trail their larger models by 8.7 percentage points and only two of the six pass the human-expert bar on the licensing examination. Withholding the answer choices, however, makes every model struggle: mean accuracy falls from 82.3% to 50.9%, and the two largest drops belong to the medically specialised models. On memorization, the strongest models reconstruct one question in four from the answer choices alone, yet accuracy holds on the questions they cannot reconstruct. We further weigh accuracy against inference cost and test whether ensembling several models improves medical question answering.

0.15

Harnessing Medical Visual-Language Models with Agentic Evidence Management

cs.CV cs.AI ·2026-11-19 ·Qiming Huang, Hanze Dong, Jipeng Zhang, Mike Zheng Shou, Xinxing Xu +1 more
benchmark similarity 0.60
Abstract · 22 pages, 3 figures. Qiming Huang, Hanze Dong, and Jipeng Zhang contributed equally

Medical vision-language agents increasingly rely on segmentation tools, and recent work has focused on acquiring the right mask, often treating a good mask as the end point of tool use. But do these agents use the resulting evidence effectively? To answer this question, we need a benchmark that separates evidence use from segmentation quality, spans multiple medical image types, and allows the same mask to be presented in different ways. Existing medical VQA datasets do not jointly provide these properties. We therefore construct Mask-Evidence MedVQA, a 2.5K-example benchmark spanning four image types, where each question is paired with an answer-relevant ground-truth mask and multiple possible renderings. Our study reveals two limitations of direct tool use. First, evidence presentation matters. Different renderings of the same fixed mask can substantially change model behavior. Second, masks introduce an evidence trade-off. Highlighting a relevant region can expose diagnostic evidence the model previously missed, but the added visual cue can also induce incorrect associations. As a result, even a ground-truth mask can correct some answers while turning initially correct ones into incorrect ones. Together, these findings show that acquiring the right mask is not enough. An agent must also decide how to present the evidence and whether it should change the answer. We therefore introduce TUNE (Tool Use is Not Enough), an evidence-management harness that explicitly manages what evidence to acquire, how to present it, and whether to accept the resulting answer update. Across three public medical VQA benchmarks, evidence management improves the fine-tuned Qwen3.5-9B backbone's mean accuracy by 4.0 percentage points. Full TUNE improves over direct tool use by 9.1 points on average across seven benchmarks and achieves competitive results against existing medical VLMs and agents.

0.27

Balancing Chain-of-Thought and Answer Supervision for Small Language Models on Medical Question Answering

cs.CL cs.AI ·2026-11-02 ·Le Zhou, Xiao Luo, Chinmay Chandra, Zhan Zhang
similarity 0.59
Abstract

Small language models (<=9B parameters) can support local medical question answering (QA) while reducing privacy and latency concerns, but effective fine-tuning remains challenging. This paper compares two chain-of-thought (CoT) supervised fine-tuning methods: Uniform-across-Sequence (UaS), which applies equal loss weighting to the full CoT-and-answer sequence, and Segment-weighted (SwS), which separately weights CoT and answer losses. We evaluate six general- and medical-domain models on multiple-choice QA (MedQA and EMS-MCQA) and free-text QA (Med-O1). Results show that neither method is universally best: on multiple-choice QA (MedQA and EMS-MCQA), SwS generally performs better, with general-purpose models benefiting most; notably, Qwen3.5-4B improves by up to 44.8% over its zero-shot baseline on MedQA. In contrast, medical-domain models show smaller or even negative gains on MCQs. On free-text QA (Med-O1), UaS performs best for nearly all models and provides consistent improvements across both model types, with the 3B Llama-3.2 model approaching the performance of much larger 7B medical-domain models. We also find that excessively long CoT generation is associated with lower performance in some models on either multiple-choice or free-text QA tasks, suggesting that limiting the CoT length during training may benefit selected models. Overall, the results show that CoT loss weighting should be matched to the task format and the knowledge already encoded in the base model, rather than using a single fine-tuning strategy for all clinical QA tasks.

0.08