CS Paper Radar

ORBITAL: Optimization of Robust Brain--Computer Inference Through Architecture-Aware Low-Precision Compression

Saim Rehman, Muhammad Shafique

cs.CV cs.CRcs.LGeess.SP ·submitted 2026-10-26 23:45 UTC · v1

Abstract

Compact electroencephalography (EEG) decoders enable embedded brain--computer interfaces (BCIs), but compression can alter adversarial robustness without proportional hardware savings. We present ORBITAL, a robustness-constrained framework combining hardware-realizable structured compression, recovery-aware operating-point selection, multi-attack evaluation, and native edge validation. Across nine subjects and three seeds on BCI Competition IV-2a, S25-TRADES achieves the highest observed mean true-union robustness among compressed EEGNet models (23.06% vs 21.27% for standard Full), with 26.27% fewer parameters and 25.10% fewer MACs. Matched controls identify TRADES as the main source of robustness recovery, improving S25 union accuracy by 6.74 percentage points over clean recovery (p=0.0039), while per-example analysis reveals boundary redistribution rather than uniform margin expansion. On Jetson Orin Nano, FP16 compression reduces board energy by up to 16.20% and latency by 8.00%. Despite 99.3% prediction agreement, native INT8 Q/DQ incurs about twice the FP16 latency and energy, demonstrating the need for joint robustness and hardware-aware optimization.

Comment
Submitted to IEEE ISCAS 2027 for Review

Closest papers

Nearest neighbours by meaning across the whole index.

AERIAL: Adversarial Evaluation of Robustness in Accuracy-Preserving Low-Precision EEG Decoders

cs.CV cs.CRcs.LGeess.SP ·2026-09-24 ·Saim Rehman, Muhammad Shafique
similarity 0.71
Abstract · Submitted to IEEE ICASSP 2027, 5 pages

Deployment-oriented compression is attractive for resource-constrained brain--computer interfaces (BCIs), but whether it changes adversarial vulnerability remains unclear. On BCI Competition IV-2a, we compare 32-bit floating-point (FP32) EEGNet and ShallowConvNet models with global magnitude pruning and simulated INT8 post training quantization (PTQ) and quantization-aware training (QAT) across nine subjects and three seeds. Simulation provides differentiable quantize--dequantize models for white-box attacks and gradient analysis, while native TensorRT deployment is used for validation. Accuracy-preserving compression does not improve direct robustness: at $ε=0.005$, EEGNet PGD accuracy remains 22--24\% across FP32, 50\% pruning (P50), PTQ, and QAT. However, P50 reduces bidirectional transfer efficiency to 0.963/0.928 (FP32$\rightarrow$P50/P50$\rightarrow$FP32), versus 0.994/0.997 for PTQ; the same trend holds for ShallowConvNet. Gradient alignment shows a corresponding separation, while native PTQ agrees with simulated clean/adversarial predictions in 95--98\% of cases. These results show that direct robustness, adversarial transfer, and deployment efficiency are distinct properties of compressed EEG decoders.

0.56

Matched-Input Estimates Differ in Sign Across Architectures: Auditing EEG Foundation Models on Motor Imagery

cs.LG q-bio.NC ·2026-09-20 ·Kevin Zhou, Sparsh Roy
similarity 0.64
Abstract

Pretrained EEG foundation models are increasingly proposed as general-purpose encoders for brain-computer interfaces, yet recent benchmarks disagree about when their representations transfer to downstream tasks. We audit LaBraM and CBraMod on motor imagery under a validation-locked protocol in which preprocessing, architecture, optimization, freeze depth, checkpoint, temperature, and method selection are determined using training-session data only. On four-class BCI Competition IV-2a, every supervised comparator evaluated here outperforms every foundation-model configuration, including validation-selected fine-tuning. We then examine a key confound: foundation models and task-specific decoders are normally evaluated using different input pipelines. Retraining three supervised architectures on the broadband arrays consumed by the foundation models produces matched-input accuracy differences of opposite sign across architectures: broadband input improves ATCNet by 0.078 accuracy while reducing EEG Conformer accuracy by 0.088. None of the three individual matched-input terms is significant after multiple-comparison correction at n = 9, so we treat the sign variation descriptively rather than as a formal architecture-by-pipeline interaction. These observed sign differences suggest that a single comparator may not provide an architecture-invariant decomposition of a pretrained-versus-supervised performance gap. The four-class deficit also does not reproduce uniformly across motor-imagery datasets: on two-class BNCI2014-004 we cannot detect the same separation between fine-tuned CBraMod and the supervised comparators. Finally, validation-fitted temperature scaling returns foundation-model calibration error to the supervised range despite substantially lower four-class accuracy.

0.32

TriRouter: Sparse-to-Dense Electrode-Space Routing for Robust EEG Motor Imagery Decoding

cs.LG eess.SP ·2026-10-16 ·Ying Zhou, Yaoxin, Mengting Liu
similarity 0.63
Abstract · Submitted to IEEE ICASSP 2027

Motor imagery brain-computer interfaces require reliable decoding from multichannel EEG, but practical acquisition often yields sparse or corrupted electrode montages. We propose TriRouter, an electrode-space routing framework with discriminative-preservation, mask-robustness, and latent-compensation paths. A validation-calibrated router uses observable channel availability to allocate path contributions, preserving complete-channel discrimination while increasing representation recovery under severe missingness. In BNCI2014-001, TriRouter outperforms standard public backbones and a dynamic-spatial-filtering corrupted-EEG baseline. It improves accuracy over the strongest corrupted-EEG baseline by 3.68, 4.02, and 6.46 percentage points at nominal 25%, 50%, and 75% missing settings, and remains effective under structured regional missingness and additional low-channel dataset evaluation.

0.17

ThinkNet: Evolutionary Deep Ensembles for Efficient Motor-Imagery EEG Classification

cs.HC cs.AIcs.LGeess.SP ·2026-09-27 ·Abdul Basit, Saim Rehman, Muhammad Shafique
publishedbenchmark similarity 0.62
Abstract · Accepted to IEEE-EMBS BHI'2026, 7 pages

Practical assistive and rehabilitative brain--computer interfaces require subject-independent motor-imagery EEG (MI-EEG) decoders that generalize to new users under limited target-user data and constrained compute. However, held-out-subject performance can be overstated when test-subject information influences preprocessing, model selection, or ensemble selection. We present \textit{ThinkNet}, a validation-controlled framework that combines train-only normalization, validation-guided evolutionary search, and validation-gated inference to identify compact decoders and inference policies for held-out subjects. We evaluate four-class BCI Competition IV-2a (session T) decoding with nine Leave-One-Subject-Out (LOSO) folds, three seeds, seven fixed decoder entries, and a broader search over ten representative decoder families; the held-out subject is never used for normalization, hyperparameter, architecture, or ensemble-policy selection. In the fixed benchmark, the validation-selected compact decoder achieved 44.35$\pm$15.41\% accuracy with 4.9K parameters, 19 KB FP32 weights, and 0.99 ms batch-1 Orin CUDA inference. Across the broader search, compact models ($\leq$25K parameters) achieved higher mean held-out accuracy than mid-size and large alternatives after selected retraining (40.10\% vs. 35.09\% and 34.78\%). Validation-gated ensembling improved over validation-selected single-model inference, reaching 43.98$\pm$16.25\% in the fixed benchmark and 43.31$\pm$15.88\% for the compact six-family ensemble. A non-deployable oracle analysis revealed a 6.1-point family-selection gap and near-zero validation--test correlation, showing that validation reliability remains a key bottleneck under subject shift. Thus, ThinkNet is a validation-controlled framework for compact MI-EEG model and inference-policy selection, rather than a single-architecture benchmark.

0.33

Nimbus Studio reproduces reference BCI decoding pipelines: a validation study on public benchmarks across protocols and paradigms

cs.HC ·2026-10-09 ·Sergey Musienko
benchmark similarity 0.61
Abstract · 6 pages. Platform: https://studio.nimbusbci.com/

Nimbus Studio is a visual pipeline platform for brain-computer interface (BCI) experiments: researchers assemble preprocessing, feature extraction, decoding, and evaluation over public benchmark datasets or their own recordings, with cross-validated evaluation protocols (including leave-one-subject-out), BIDS export, and bring-your-own Python model classes. Whether its numbers can be trusted is a fair question for any such platform. We answer it with a parity study: six standard BCI decoding pipelines (CSP+LDA, Riemannian MDM, tangent-space logistic regression through the platform's bring-your-own-code node, P300 xDAWN+LDA, and the deep ShallowConvNet and EEGNet) were evaluated on three public datasets (motor-imagery BNCI-2014-001/004; P300 BNCI-2014-009) under two protocols (per-subject session holdout and pooled leave-one-subject-out cross-validation via the platform's planned-CV driver), once through Nimbus Studio's execution engine and once through independent, hand-written reference implementations built directly on MNE-Python, scikit-learn, pyriemann, and braindecode. Every deterministic pipeline matched the reference exactly (0.00 points maximum difference across all 54 session-holdout subject-runs and all CSP/MDM grouped-CV folds), including pipelines through the bring-your-own-code node and the CV orchestration; the remaining grouped-CV cells agree to floating-point precision (worst case 0.06 points, about one trial per fold). The stochastic deep models agreed within seed-to-seed training variability, estimated with multi-seed reruns on each side. The platform's execution engine therefore computes the same science as the reference stack across protocols, paradigms, and extensibility surfaces. The platform is available at https://studio.nimbusbci.com/, and the complete harness and per-subject results accompany this paper for independent verification.

0.15

Benchmarking EEG Foundation Models at Scale: Lessons from 20,000 Evaluations

cs.LG eess.SP ·2026-09-26 ·Zhige Chen, Shu Peng, Chengxuan Qin, Rui Liu, Rui Yang +2 more
benchmarkcode/data similarity 0.60
Abstract · 91 pages, including appendices and supplementary material

Electroencephalography (EEG) foundation models (FMs) promise transferable neural representations, yet their advantages over strong supervised baselines and their prospects for further scaling remain unclear. To address these questions, we introduce EEG-Arena, an open-source benchmark covering 30 EEG FMs and 25 supervised baselines evaluated on 57 downstream tasks from 23 public datasets. Through more than 20,000 evaluations across five experimental protocols, we assess downstream performance, pretraining benefits, model size scaling, pretraining data scaling, and robustness to channel configuration. We find that (1) EEG FMs outperform strong task-specific supervised baselines on most evaluated tasks, particularly under non-bipolar settings; (2) compared with architecture-matched supervised training from scratch, pretraining improves both early optimization and final downstream performance, with larger and more consistent gains as more labeled downstream data become available; (3) existing EEG FMs do not exhibit a consistent positive relationship between parameter count and downstream performance; (4) under a fixed architecture, increasing the pretraining data scale yields sustained downstream gains; and (5) channel-flexible FMs achieve higher absolute performance than channel-constrained models across most evaluated channel configurations. Together, these findings demonstrate the downstream value of EEG FMs and identify pretraining data expansion as a promising direction for further progress. To support continued research, we release EEG-Arena as an open-source evaluation framework that provides shared infrastructure for reproducible benchmarking, model comparison, and community-driven development.

0.56

NeuroDyn-EEG: An Interpretable Pre-trained Model for EEG Based on Neural Dynamics

cs.NE ·2026-09-29 ·Yi Cui, Tong Zhao, Jiaxin Lei, Chuyi Yang, Yifan Cui +3 more
code/data similarity 0.60
Abstract · Yi Cui and Tong Zhao contributed equally. Corresponding authors: Ling Zhang, Yuxiang Yan, and Bo Hong

Clinical scalp electroencephalography (EEG) offers a noninvasive window into neural dynamics of neuropsychiatric disorders. However, discriminative deep models often lack anatomically indexed physiological interpretability. We propose NeuroDyn-EEG, a pretraining framework integrating generative priors from neural dynamics. It couples an extended Jansen-Rit neural mass model, leadfield-based source projection, and simulation-based parameter inversion. Trained on synthetic parameter-EEG pairs within physiological ranges, NeuroDyn-EEG estimates 11 regional parameter families across 90 AAL regions plus one global parameter from standard 19-channel EEG, using only ~2.43M trainable parameters. We evaluate the framework across three levels. First, controlled simulations demonstrate robust parameter recovery under diverse noise conditions, while real resting-state EEG evaluations confirm spectral and phase consistency in an inverse-forward closed loop. Second, on four clinical benchmarks (AD65, PD31, Figshare MDD, and TUAB), NeuroDyn-EEG achieves competitive classification performance, securing the highest BACC, AUROC, and AUCPR on PD31 and MDD, and highest BACC on AD65. Third, post hoc regional analyses reveal disease-specific alterations: local synaptic connectivity C_1 involves the most altered regions in AD65, whereas the firing threshold theta ranks first in MDD, offering testable mechanistic hypotheses. Overall, NeuroDyn-EEG maps scalp EEG to anatomically indexed dynamical parameters, bridging representation learning and mechanistic neurophysiology. Code: https://github.com/Gnosis-Neurodynamics/NeuroDyn-EEG.

0.21

RobustSeiz: An Open-Source Framework for Benchmarking the Robustness of EEG Seizure Detection Models

cs.LG eess.SP ·2026-09-03 ·Mohammad Mohammadi, Alireza Zarei
code/data similarity 0.60
Abstract · 28 pages, 13 numbered figures, 9 tables; full-page graphical abstract and supplementary material included. Submitted to the Journal of the A…

Despite strong performance on held-out electroencephalography (EEG) data, seizure detectors may fail under real-world acquisition variability, artifacts, and adversarial inputs. We introduce RobustSeiz, an open-source, model-agnostic framework that provides a standardized, reproducible protocol for stress-testing and comparing seizure detectors under controlled, clinically motivated distribution shifts before deployment. We standardize four public scalp-EEG corpora (CHB-MIT, TUSZ, Siena, and SeizeIT1) into BIDS-EEG trees and evaluate subject-independent detectors on held-out splits. Environment, noise, and adversarial transforms are swept over predefined hyperparameter grids. Each run reports sample- and event-level sensitivity, precision, F1, false positives per 24 h, Lead and Lag onset timing, and Monte Carlo dropout predictive agreement. RobustSeiz includes a Dockerized GPU pipeline, experiment registry, and full-evaluation and research-subset modes. We demonstrate the framework with a contemporary seizure detector on TUSZ across the complete implemented shift grid; an AWGN analysis illustrates how perturbation severity changes detection quality, onset timing, and predictive agreement. RobustSeiz provides a shared benchmarking standard for evaluating seizure-detector robustness under realistic clinical stressors, extending pre-deployment assessment beyond clean-data accuracy.

0.22