Perceptual Differences and Preferences in Speech Enhancement

Simon Dahl Jepsen, Jesper Rindom Jensen

eess.AS cs.SD ·submitted 2026-10-27 09:27 UTC · v1

Abstract

Speech enhancement (SE) systems are commonly evaluated with objective metrics, with and without references, and with categorical subjective listening tests, all measuring speech quality and intelligibility. So far, it is unclear from such evaluations whether the processed speech is perceptually different or is preferred by everyday listeners. We investigate discrimination and preference as complementary dimensions of SE evaluation through crowdsourced triangle and pairwise preference tests across four SE systems, with comparisons to clean references. Results show that both listeners' ability to distinguish and whether they exhibit systematic preference vary across systems and substantially across acoustic conditions. Pairwise evaluations of objective metrics showed variable correlation with both discriminability and preference, motivating further studies into these novel aspects in speech enhancement evaluation.

Comment
Submitted for ICASSP 2027, 5 pages, 5 figures, 1 table

Closest papers

Nearest neighbours by meaning across the whole index.

Perceptual Quality Loss or Loss of Perceptual Quality?

eess.AS cs.LG ·2026-09-28 ·Danilo de Oliveira, Tal Peer, Maurício do V. M. da Costa, Timo Gerkmann
similarity 0.71
Abstract · Submitted to ICASSP 27

Contemporary deep speech enhancement (SE) models are often trained with specific auxiliary terms in the loss function as a way to improve their performance in terms of perceptual metrics. Nevertheless, a higher score on a perceptual metric does not necessarily correlate with an improved listening experience. Through objective and subjective experiments, we assess the performance of SE models trained with two different types of auxiliary PESQ loss terms. The numerical evaluation on a suite of standard metrics suggests that, while models optimized for PESQ naturally obtain higher PESQ scores in the test set, for most other metrics the scores do not significantly change. In some cases, the PESQ loss even results in worse PESQ scores on mismatched data. A formal listening experiment reveals that the models without a PESQ loss were generally preferred over models that include it, across all settings. Finally, we analyze the relative importance of PESQ in the composite metrics CSIG, CBAK and COVL, and find that PESQ dominates all of them. Our study highlights the perils of over-reliance on PESQ and stresses the importance of a complete evaluation procedure for SE.

0.14

Improving Predicted MOS Scores, Not Perceived Quality: Multi-Predictor Test-Time Optimization of Enhanced Speech

eess.AS cs.SD ·2026-09-30 ·Tsubasa Ochiai, Marc Delcroix, Nahomi Kusunoki, Rintaro Ikeshita, Naohiro Tawara +3 more
similarity 0.68
Abstract · 5 pages, 2 tables

Non-intrusive MOS predictors are widely used instead of subjective listening tests to evaluate and rank speech enhancement (SE) systems. If they accurately reflect perceived quality, raising their scores should lead to higher-quality speech. We present the first comprehensive analysis of test-time optimization for the SE task, which directly modifies the enhanced signal to raise the average of multiple MOS predictor scores. On seven systems from the URGENT 2026 challenge, we find that 1)~all the optimized predicted scores increase while reference-based metrics remain nearly unchanged, 2)~a non-optimized predicted score does not increase, and 3)~a MUSHRA listening test shows no improvement in perceived quality. These findings reveal a risk that such optimization can distort evaluations, e.g., biasing comparisons of SE systems regardless of their perceived quality. We believe these findings can inform future evaluation practices: they suggest that predictors used for optimization should not be used for evaluation, and that challenges should keep the predictors used for ranking undisclosed.

0.13

How Reliable Are Predicted MOS for Reproducing Human System-Level Preferences in Speech Enhancement?

cs.SD eess.AS ·2026-09-30 ·Nahomi Kusunoki, Tsubasa Ochiai, Naohiro Tawara, Marc Delcroix, Naoyuki Kamo +2 more
similarity 0.67
Abstract · 5 pages, 2 figures, 2 tables

We investigate whether predicted Mean Opinion Scores (MOS) can reliably support system-level comparisons of speech enhancement (SE) methods by introducing system-level preference accuracy (SPA). Although MOS prediction models are widely used to evaluate SE systems, their performance is typically assessed by correlation with human-rated MOS, which does not guarantee agreement on which system is better. SPA addresses this gap by directly evaluating whether predicted and human-rated MOS yield the same system preferences. Using SPA, we systematically evaluate three settings: single prediction models, ensembling, and domain adaptation. Through experiments, SPA varies substantially across single prediction models, from 9.4% to 76.8%. Even the best model disagrees with human judgments in approximately 23% of system comparisons. Ensembling yields only limited improvement, while domain adaptation tends to substantially improve SPA in the closed condition but brings only modest gains in the more practical open condition, where neither the target systems nor the speakers are known. These results suggest that SPA can reveal errors correlation-based evaluation alone does not expose, and that predicted MOS alone can lead to unreliable conclusions in practical SE system comparison.

0.24

Absolute Quality Ratings of Speech Enhancement Systems by Listeners of Different Ages and Degrees of Hearing Loss

eess.AS ·2026-09-16 ·Matteo Torcoli, Chih-Wei Wu, Andrea Esposito, Phillip A. Williams, Katrien Cambier +4 more
similarity 0.66
Abstract · 5 pages, 4 figures, 2 tables

Speech Enhancement (SE) supports listening, particularly for older adults with age-related hearing loss. Yet, enhanced Speech Quality (SQ) is commonly evaluated by young normal-hearing listeners, and how their ratings translate to older adults remains under-explored. We compared absolute SQ ratings from 40 younger normal-hearing listeners (20-30 years) and 67 older listeners (60-95 years) with diverse audiometric profiles, after screening. Test materials comprised natural dialogues with realistic backgrounds. SQ differences between SE systems that were clear for younger listeners were smaller or inseparable in older groups, regardless of hearing status. Hearing loss severity was associated with lower absolute ratings, but did not strongly modulate the contraction in separable SQ differences. A small, audiometrically mixed subgroup of older listeners showed younger-like rating patterns, suggesting that peripheral audiology alone cannot explain the contraction.

0.30

Perceptually Better, Semantically Worse: Measuring Speech Enhancement Impact on LLM-Based Voice Systems

cs.SD eess.AS ·2026-08-31 ·Randy Frans Fela, Pejman Mowlaee
top venuebenchmark similarity 0.65
Abstract · Accepted at EMNLP 2026. 12 pages, 4 figures, 8 tables

Speech enhancement (SE) is commonly applied as a preprocessing step in spoken AI pipelines under the assumption that better audio quality improves downstream task performance. Whether SE-induced distortions propagate to downstream LLM task performance remains an open question. We introduce Output Divergence Rate (ODR), which measures how often SE changes an LLM's intent classification relative to clean speech, and benchmark five conditions on 2,974 SLURP clips using Whisper large-v3 and wav2vec2-large cascades. Every condition produces ODR significantly above zero ($p < 0.001$, binomial test). MetricGAN{+} more than doubles ODR versus unenhanced noisy speech (0.318 vs. 0.135) despite improving PESQ, and unmitigated echo reaches an ODR of 0.836 through speaker substitution, a failure WER cannot capture. Audio quality metrics range from near-zero to moderate correlation with ODR (SQUIM-MOS $ρ=-0.068$, PESQ $ρ=-0.467$). The MetricGAN{+} and echo results replicate across ASR architectures, indicating that standard audio quality metrics are insufficient for LLM pipeline quality.

0.47

CHiME-9 ECHI: A Machine Learning Challenge for Enhancing Conversations to Address Hearing Impairment

cs.CL ·2026-09-22 ·Robert Sutherland, Thomas Kuebert, Marko Lugger, Stefan Petrausch, Eline Borch Petersen +4 more
similarity 0.65
Abstract · Accepted to the International Workshop on Acoustic Signal Enhancement (IWAENC), Cremona, Italy, September 2026

This work presents the task and results of the CHiME-9 challenge for Enhancing Conversations to address Hearing Impairment. The challenge considers the scenario of four-party conversations in a noisy, cafeteria-style environment with interfering speech sources and sound effects. Participants are provided with audio recordings made with Meta Aria glasses and hearing aid microphones, and clean speech samples of the conversation participants. The task is to extract the speech of the conversation partners from the noisy multi-channel recordings with the goal of improving the intelligibility and quality of the speech, evaluated using objective metrics and subjective listening tests. This paper reviews submissions from seven teams and ranks them on a combination of subjective intelligibility and quality. Results show that while the objective metrics do not reflect listener performance, the top systems were able to make substantial improvements over the challenge baseline in both intelligibility and quality ratings.

0.42

A Hybrid Classical-Learning Framework for Adaptive Decision Directed Speech Enhancement

eess.AS ·2026-08-10 ·Ali Rajabi, Xiangwei Zhou
similarity 0.64
Abstract · Novelty is not clear

Speech enhancement aims to recover clean speech signals from noisy observations while preserving speech quality and intelligibility. Classical methods such as Spectral Subtraction and Decision-Directed (DD) enhancement remain widely used because of their interpretability and low computational complexity, but they may suffer from musical-noise artifacts or excessive attenuation of weak speech components under low signal-to-noise ratio (SNR) conditions. This paper proposes an Adaptive Beta-Constrained Decision-Directed (ABCDD) speech enhancement framework that extends the conventional DD method through a frame-dependent lower gain bound. The introduced beta parameter controls the tradeoff between noise suppression and speech preservation. To automate parameter selection for large and diverse datasets, a lightweight multilayer perceptron (MLP) model is further developed to predict frame-level beta values directly from noisy-speech features. The proposed framework is evaluated using both a representative speech example and large-scale testing on the VoiceBank-DEMAND dataset. In the representative example, ABCDD outperformed conventional Spectral Subtraction and classical DD across multiple objective metrics, including SNR, Log-Spectral Distance (LSD), Root-Mean-Square Error (RMSE), correlation, and Scale-Invariant Signal-to-Distortion Ratio (SI-SDR). On 100 unseen VoiceBank-DEMAND test files, the proposed MLP-beta ABCDD method improved average scale-aligned SNR from 9.41 dB to 13.82 dB, corresponding to an average gain of 4.41 dB. The results indicate that combining interpretable classical enhancement structure with lightweight machine-learning-based parameter adaptation provides an effective and practical direction for robust speech enhancement.

0.04

Rethinking Batch Composition: Promoting Feature Diversity for Speech Enhancement

eess.AS ·2026-10-15 ·Mingchi Hou, Ina Kodrasi
similarity 0.64
Abstract

Speech enhancement systems are commonly trained using randomly sampled mini-batches, which may contain limited diversity in intrinsic acoustic characteristics of the clean speech signals. Motivated by previous findings linking clean speech characteristics to enhancement performance, we propose a feature-stratified mini-batch sampling strategy that divides training examples into quantiles according to a clean-speech characteristic and enforces equal representation within each mini-batch. Experiments across two large-scale English and Spanish speech datasets and a smaller dataset containing neurotypical and pathological speech demonstrate improvements over standard random mini-batch sampling across multiple objective enhancement metrics. Ablation studies demonstrate that the gains are robust across training runs, while their magnitude depends on the acoustic characteristic used for stratification. The proposed strategy requires no modification to the enhancement model or training objective, providing a simple and complementary approach to speech enhancement training.

0.11