Abstract

The operation of power grids has substantial economic consequences, affecting generation costs and, ultimately, electricity prices. The Optimal Transmission Switching (OTS) problem seeks to reduce these costs by selectively switching off transmission lines. However, OTS gives rise to a challenging mixed-integer nonlinear optimization problem that is difficult to solve at operationally relevant timescales, particularly as rapidly changing loads create a need for real-time switching decisions. To address this challenge, we develop a machine learning-guided method that identifies high quality line switching decisions in real time. Specifically, we construct a grid-specific switching-value model that rapidly estimates the generation-cost reduction associated with opening transmission lines by fine-tuning a pretrained model for AC optimal power flow (AC-OPF). The switching-value model provides signals to guide promising switching decisions, and topologies proposed by the model are evaluated using exact AC-OPF solvers to verify feasibility and obtain the actual generation cost. We develop multiple strategies that use the ML surrogate to efficiently explore the combinatorial space of transmission topologies, including Fixed-Rank Search, Adaptive-Rank Search, and Swap-Enhanced Search. Across multiple benchmark networks, our proposed algorithms identify line switching decisions that significantly reduce generation cost within a 50s computational budget. In particular, under a realistic data center buildout scenario on the 2,000-bus synthetic Texas grid, our approach reduces generation costs by 31.97% and gross nodal load payments by 94.34%. More broadly, our results demonstrate that a fine-tuned surrogate can effectively guide search even without guaranteeing feasibility, enabling classical optimization methods to tackle large nonlinear combinatorial problems on operationally relevant timescales.

Closest papers

Nearest neighbours by meaning across the whole index.

Scalable Self-Supervised Learning for Multiphase AC-OPF in Distribution Systems with Topology Reconfiguration

eess.SY cs.LGmath.OC ·2026-08-25 ·Hoang T. Nguyen, Shaohui Liu, Reetam Sen Biswas, Varsha Pendyala, Nurali Virani +2 more
similarity 0.68
Abstract · Source code will be published following the review process

The proliferation of distributed energy resources (DERs) in distribution grids enables the active coordination of these assets to reduce costs and enable cleaner operations. Realizing this potential requires solving multiphase AC optimal power flow (AC-OPF) quickly across varying loads, DER availabilities, and topology reconfigurations, at much greater speed and scale than conventional nonlinear solvers. Learning-based surrogates can offer millisecond inference, yet existing methods target largely balanced transmission systems and do not scale to the multiphase, unbalanced, and reconfigurable nature of distribution feeders at utility scale. We present the Penalty + Sequential Linearized Feasibility Seeking (SLFS) algorithm, a self-supervised learning framework for multiphase distribution AC-OPF under switch-induced topology changes. Penalty+SLFS requires no labeled optimal solutions and trains directly from the AC-OPF objective and constraints through a differentiable fixed-point power flow solver, avoiding expensive label generation and admitting robust training procedures. Topology changes are handled efficiently using Sherman-Morrison-Woodbury updates of the admittance-matrix inverse, while an M-step Jacobian approximation accelerates differentiation through the power flow solver. At inference, SLFS repairs any infeasible predictions, providing feasibility guarantees with low computational overhead. On IEEE feeders ranging from 13 to 8,500 nodes, Penalty+SLFS achieves negligible optimality gaps and near-zero constraint violations, delivers up to three orders of magnitude speedups over IPOPT, and remains robust under large distributional shifts, demonstrating a viable path toward real-time, topology-aware AC-OPF for large-scale distribution grids.

0.23

PowerModels-ACOPF-AI: On-the-Fly Machine Learning Approach for Solving AC Optimal Power Flow Integrating Renewable Energy Sources

eess.SY ·2026-09-16 ·Bhuban Dhamala, Jose Tabarez, Anup Pandey
benchmark similarity 0.68
Abstract

The increasing complexity of modern power systems, driven by high renewable penetration, load variability, and operational uncertainty, demands fast and reliable solutions to the AC optimal power flow problem (AC-OPF). Traditional optimization methods, though accurate, often struggle with scalability and high computational burdens, making them impractical for real-time use in large networks. This paper introduces PowerModels-ACOPF-AI, a two-stage Bayesian Neural Network (BNN) surrogate designed to predict generator set points, bus voltages, and phase angles with uncertainty. The framework integrates a performance-sensitive on-the-fly learning mechanism that identifies regions of degraded prediction accuracy and dynamically retrains with additional AC-OPF solutions generated by PowerModels.jl. This self-adaptive loop ensures robust performance, enabling the model to maintain accuracy under novel or highly variable operating conditions. Validation on benchmark test systems of different sizes, namely the 30-bus, 200-bus, and 500-bus networks, demonstrates strong generalization capability, efficient handling of stochastic renewable injections, and the ability to provide rapid, uncertainty-aware predictions. Beyond predictive accuracy, the proposed approach offers practical value as both a real-time advisory tool for system operators and a fast initializer for conventional solvers, thus supporting resilient and efficient grid operation in future power systems.

0.16

Expediting AC Contingency Analysis using a Basecase Machine Learning Model

eess.SY ·2026-09-29 ·Md Obaidur Rahman, Vassilis Kekatos
similarity 0.67
Abstract · 10 page, 7 figures

Grid planning and operation under increasingly variable operating conditions require fast and accurate AC power flow (AC-PF) contingency analysis for numerous line outages. While ML models can accelerate these computations, existing approaches often require either training separate models for different contingencies or a single model using data from multiple topologies. Both approaches incur substantial offline data generation and training costs. To address this gap, this work proposes a fixed-point framework that reuses a single ML model trained exclusively on basecase topology data to predict post-contingency AC-PF states under any non-critical single-line outage. We analyze the proposed method's convergence under the DC model approximation and derive its convergence rate in terms of network parameters. As a side result, we show that power transfer distribution factors (PTDFs) for non-critical lines have magnitudes less than one. We further characterize the ML training region to accommodate PF specifications encountered during fixed-point iterations and derive bounds on ML prediction errors for post-contingency state estimates. Numerical tests on a 6,717-bus synthetic Texas system demonstrate convergence across all non-critical single-line outages, with prediction errors remaining close to those of basecase. The proposed framework offers a favorable tradeoff between the speed of DC solvers and Newton-Raphson accuracy.

0.11

Benchmarking a Grid Foundation Model for AC Optimal Power Flow: Feasibility and Warm-Start Results on Synthetic Texas and South Carolina Grids

eess.SY ·2026-11-17 ·Tam Kemabonta, Brighton Ombuki, Vladimir Abdelnour
similarity 0.65
Abstract · 5 pages, 3 figures, 2 tables. Submitted to the 2027 IEEE PES General Meeting

Learning-based surrogates for alternating-current optimal power flow (AC-OPF) are often judged by the gap between their objective value and that of a nonlinear solver, which does not show that a prediction satisfies power balance and network limits. This paper tests whether predictions from the pretrained foundation model GridSFM-Open 1.1.0, recently released by Microsoft, are feasible AC-OPF operating points and whether they are useful initial values for a nonlinear solver. The model was evaluated zero-shot and after fine-tuning on 10, 100, and 1,000 labeled scenarios (FT10, FT100, and FT1000) on 500 scenarios for each of two synthetic grids, ACTIVSg2000 (Texas) and ACTIVSg500 (South Carolina), with Ipopt, MATPOWER MIPS, and pandapower PIPS as solver references. The lowest Texas median cost gap, 0.44\% for FT100, coincided with thermal violations in 24.1\% of cases and a median maximum bus power mismatch of 89 MW and 197 Mvar. Texas zero-shot predictions had a median maximum mismatch of 648 MW and 1,641 Mvar, and every South Carolina case violated a thermal limit for every model variant. Seeding Ipopt with FT1000 predictions gave geometric-mean solve-time speedups of 1.55x on South Carolina and 1.12x on Texas (p = 0.06, not significant at the 5\% level), while zero-shot seeds slowed South Carolina solves (0.26x). A small objective gap therefore did not indicate feasibility: although median zero-shot inference took only 1.32 s on Texas and 0.157 s on South Carolina on a shared host, every prediction still required a nonlinear solver, and fine-tuned predictions gave modest, grid-dependent warm-start speedups while zero-shot predictions slowed convergence on one grid. GridSFM may therefore be useful for initializing a nonlinear solver, but obtaining feasible AC-OPF solutions still required the solver.

0.36

Quantifying the Cost of Restoring AC Feasibility for Approximate Optimal Power Flow Solutions

eess.SY math.OC ·2026-11-11 ·Sanjay Johnson, Sungho Shin
theory similarity 0.65
Abstract · 5 pages, 4 figures, submitted to 2027 IEEE Power & Energy Society General Meeting

Power system operations rely on approximate solutions of the AC optimal power flow problem, most notably the DC optimal power flow used in security-constrained unit commitment and economic dispatch, while convex relaxations, machine learning surrogates, and other approximations are studied extensively in the academic literature. Because these approximations neglect or relax parts of the AC power flow equations, their solutions must be adjusted before dispatch; for example, the DC optimal power flow, which neglects transmission losses, reactive power, and voltage magnitude variations, is known to produce solutions that are always infeasible. The cost of this adjustment is not adequately understood. This paper proposes a method that quantifies, for any approximate solution, the minimum cost of the adjustments that restore AC feasibility, which is a lower bound on the cost of the heuristic adjustments used in practice. We apply it to the DC optimal power flow, the second-order cone and quadratic convex relaxations, and the AC optimal power flow solved to a loose relative tolerance of $10^{-4}$ instead of $10^{-8}$. Relative to the AC optimal power flow solution obtained from a local nonlinear optimization solver, and even with the minimum adjustment, the DC optimal power flow requires adjusting, on average, generators that account for 15.6% of total generation capacity and incurs a 1.10% cost increase; the convex relaxations require more adjustment (17.2% and 16.9%) but smaller cost increases (0.68% and 0.78%); and the loose-tolerance AC optimal power flow requires 6.1% and incurs 0.42%. These results indicate significant value in operating markets directly on the AC optimal power flow, which avoids the distortion of the dispatch and prices caused by heuristic feasibility restoration.

0.35

ML-OPF-Bench: Benchmarking Machine Learning for Optimal Power Flow

eess.SY cs.LG ·2026-10-03 ·Xinyi Liu, Xuan He, Danny H. K. Tsang, Yize Chen
benchmarkcode/data similarity 0.64
Abstract · 25 pages, 9 figures, in submission. Code available at https://github.com/XinyiLiu04/ML-OPF-Bench; Datasets available at https://huggingface.…

Machine Learning (ML) methods promise a fast solution process for Optimal Power Flow (OPF). While inconsistent test cases, implementations, and evaluation metrics across existing studies make it challenging to determine which algorithmic advances are most critical for real-world deployment. To this end, we propose ML-OPF-Bench, a unified benchmark for AC- and DC-OPF that evaluates representative ML algorithms under a consistent pipeline, stress-tests them across system sizes, distribution shifts, and resource budgets, and ranks them with a multi-objective framework. We find that prediction accuracy alone is not a reliable indicator of operational feasibility. Under heavily loaded, congested conditions, even the strongest in-distribution performers lose their advantage, while feasibility is maintained largely by post-processing that enforces the target constraints rather than by the underlying pure ML predictor. Data scaling shows that prediction accuracy and constraint violations follow different trajectories, whereas compute scaling shows that returns diminish and that larger models do not consistently perform better. These results expose critical trade-offs among ML methods' speed, accuracy, and feasibility, and offer practical guidance for future ML-OPF design. We open-source the benchmark as an extensible Python package for integrating new learning-based OPF algorithms and evaluating them under the same standard as the existing baselines.

0.33

Decision-Focused Learning via Neural Optimization Layers for Battery-Assisted Grid-Import Smoothing in AI Data Centers

eess.SY cs.LGmath.OC ·2026-11-10 ·Xinda Zheng, Canchen Jiang, Frits de Nijs, Edward Lam, Markus Wagner
similarity 0.62
Abstract

Rapid AI data-center power fluctuations challenge grid integration. Sustained grid-import smoothing requires allocating limited battery power and energy under uncertain demand. We formulate risk-aware BESS scheduling that coordinates advance reserve commitments and demand-responsive dispatch, accounting for operating costs, grid-ramp penalties, and their conditional value-at-risk. We develop battery scheduling decision-focused learning (BS-DFL) with a constraint-aware neural optimization layer trained directly from this objective without optimal-solution labels. The trained layer is then frozen to guide demand-predictor learning through scheduling costs and ramping risk, enabling solver-free rolling-horizon scheduling. In a 10,000-minute simulation using loads derived from measured AI workloads, BS-DFL reduces mean absolute minute-to-minute grid-import changes by 71.70% and total scheduling cost by 18.01% relative to an MSE-trained predictor coupled with a mixed-integer linear programming solver, with an average decision time of 18.77 ms.

0.26

Strengthening AC optimal power flow relaxation through offline bound tightening and linear approximations

eess.SY math.OC ·2026-10-23 ·Xiangxin An, Constance Crozier, Santanu S. Dey
similarity 0.61
Abstract · 15 pages, 4 figures

The alternating-current optimal power flow (ACOPF) problem is fundamental to power system operation and planning, but its nonconvexity makes globally optimal solutions of large-scale instances computationally challenging. Convex relaxations provide tractable lower bounds for assessing solution quality and supporting global optimization, although their effectiveness depends strongly on relaxation strength. This paper proposes an offline convexification and bound tightening framework for constructing strong linear programming (LP) relaxations for families of related ACOPF instances. Rather than repeating the tightening procedure for each instance, we compute variable bounds and second-order cone outer-approximation (SOC-OA) cuts offline using a demand-slack model and reuse them for subsequent instances with the same topology and admissible demand variations. Computational results on PGLib instances show that the fully offline approach achieves an average gap of $4.32\%$, compared with $3.80\%$ for the fully online approach, while achieving an average speedup of approximately $272\times$. The results demonstrate that offline convexification and bound tightening can recover most of the relaxation improvement of online tightening while significantly reducing the computational burden for repeated ACOPF evaluations.

0.32