CS Paper Radar

DiffUltra: Task-Guided Pathology Synthesis for Large-Scale Real-World Lung Ultrasound Data

Gary Y. Li, Yu-Cheng Chou, Li Chen, Mohsen Zahiri, Priyam Patel, Balasundar Raju, Jochen Kruecker, Alvin Chen

eess.IV ·submitted 2026-10-28 20:46 UTC · v1

Abstract

Despite their scale, large medical imaging datasets may underrepresent clinically relevant pathological presentations. Synthetic data can expand coverage, but findings must remain compatible with surrounding anatomy. This is challenging in ultrasound, where findings resemble surrounding tissue and must be positioned relative to anatomical landmarks. We propose DiffUltra, a task-guided latent diffusion pipeline that models pathological structure and spatial context, and screens synthetic images for downstream utility. DiffUltra conditions generation on structural masks decomposing findings into anechoic, hypoechoic, and hyperechoic subregions. Two placement strategies insert findings into pathology-absent backgrounds or replace existing findings with structurally matched pathology from other patients. A filter trained exclusively on real data retains images whose predictions agree spatially with target boxes. We evaluate DiffUltra for lung ultrasound detection of pleural effusion and consolidation, using over 700,000 expert-annotated frames from 598 patients at 12 sites. Averaged across three real-data scales, synthetic insertion significantly improved video-level AUROC for both pleural effusion (p = 0.017) and consolidation (p < 0.01). For pleural effusion, frame-level average precision improved by 4.5 percentage points on average and by 6.1 points using only 10% of real data (p < 0.01 for both). Synthetic insertion also yielded larger average precision gains than an existing diffusion-based lesion-insertion method at every scale. At full scale, targeted synthesis improved AUROC for both pathologies by 1.1-3.9 points in an underrepresented anatomical zone and on a held-out acquisition system. These results suggest that anatomically constrained, task-guided synthesis can help address coverage gaps in ultrasound training data.

Comment
This work has been submitted to the IEEE for possible publication. Copyright may be transferred without notice, after which this version may no longer be accessible

Closest papers

Nearest neighbours by meaning across the whole index.

LungMend: A Healthy-Only Latent Diffusion Shape Prior for Lung Mask Correction in Severe Tuberculosis CT

cs.CV ·2026-11-04 ·Rezkellah Noureddine Khiat, Pierre-Yves Brillet, Catalin Fetita
code/data similarity 0.64
Abstract · 5 pages (4 + 1 references), 2 figures, 2 tables. Submitted to IEEE ISBI 2027. Code: https://github.com/noureddinekhiati/LungMend

Lung segmentation models such as R231 are widely used, but they fail on severe tuberculosis (TB) CT: cavities and consolidations look like non-lung tissue and are left out of the mask. We present LungMend, a post-processing model that corrects such masks using only healthy anatomy. A latent diffusion model, trained on healthy lungs with synthetically corrupted masks, learns to recover the complete lung from the faulty mask and the bone anatomy, without any pathological data or CT intensities. LungMend recovers cavities and consolidations that R231 misses and improves accuracy on expert-annotated slices. Code: https://github.com/noureddinekhiati/LungMend

0.38

Patch-to-Global: Random Patch Diffusion for Globally Consistent Megapixel Artifact Inpainting in Whole Slide Images

cs.CV ·2026-09-21 ·Hyeseong Lee, Eunsu Kim, D M Bappy, Ho Heon Kim, Youngsuk Lee +4 more
top venuecode/data similarity 0.64
Abstract · 10 pages, 5 figures, accepted at MICCAI 2026

Although deep learning has advanced Whole Slide Image (WSI) Analysis, tissue artifacts like bubbles and folds often cause silent failures by concealing essential morphology. Current pathology image restoration methods are mostly restricted to small patches, struggling to maintain global structural coherence at a megapixel scale. We introduce RestorePath, a framework for globally consistent megapixel scale inpainting that reconstructs diagnostic structures in histological image to prevent incorrect high-confidence predictions and lower error rates. Our model utilizes a Latent Diffusion Model (LDM) conditioned on Pathology Foundation Model (PFM) embeddings, integrating Large Kernel Attention (LKA) to manage long-range dependencies during random patch diffusion. Enhanced by Distance-Weighted Interpolation (DWI) and an Adaptive Guidance Scale (AGS), RestorePath ensures structural consistency and fidelity by modulating information from surrounding patches. Evaluations across TCGA-BRCA, BACH, and Camelyon16 datasets for images ranging from 512 to 4608 pixels demonstrate state-of-the-art performance in maintaining histological consistency. RestorePath significantly improves downstream Computational Pathology (CP) tasks, outperforming both raw artifact images and the conventional Detect-and-Discard (D&D) approach. The code is available at https://github.com/PathfinderLab/RestorePath

0.77

Open ultrasound foundation model for robust segmentation and clinical measurement across heterogeneous settings

cs.CV ·2026-09-16 ·Chao Qin, Fahad Shahbaz Khan, Salman Khan, Sarim Ather, Siddiq Anwar +2 more
code/data similarity 0.64
Abstract · The PDF includes the Supplementary Information. Code is available at https://github.com/AlfredQin/sonobase

Ultrasound is the most widely deployed imaging modality worldwide, yet clinical AI remains fragmented into narrow single-task models that fail when device, operator, or anatomy changes. Here we present SonoCorpus, an open resource unifying 456,963 images and 1,626,085 expert masks from 53 public datasets spanning 24 clinical applications and 17 countries, and SonoBase, an interactive segmentation foundation model pretrained on it. Across fifteen evaluation datasets introducing new organs, devices, operators, and geographies, SonoBase outperforms SAM2, MedSAM2, and the concept-promptable MedSAM3 on every dataset and matches per-dataset specialist models trained on the same data; on fully external data it exceeds the accuracy these baselines achieve on their own in-distribution benchmarks. Ejection fraction derived from its segmentations falls within inter-observer variability (6.63\% error), with fewer misclassifications at the defibrillator-candidacy threshold than either promptable baseline (13\% versus 18--42\%); fetal head-circumference (1.81~mm) and gestational-age (1.2 days) errors fall below inter-observer variability. Where a baseline fails outright, one in four test cases, SonoBase recovers a usable segmentation in 81\% of them, including on handheld probes operated by minimally trained users in two low- and middle-income countries (Sierra Leone and Tanzania). Five labeled examples can help the model adapt to a new setting, and the identical training protocol transfers well to newer models such as SAM3, locating the advantage in ultrasound-specific pretraining rather than any single architecture. To ensure reproducibility and enable the community to build on SonoBase as a platform, we release all checkpoints, optimizer states, data-split indices, deduplication hashes, and starter code at https://github.com/AlfredQin/sonobase.

0.36

CPathOGen: Spatially and Morphologically Controlled H&E Counterfactuals for Probing Pathology Models

eess.IV q-bio.QM ·2026-09-30 ·Samarth Singhal, Varang Rai
code/data similarity 0.63
Abstract

Computational pathology models infer biologically and clinically meaningful outcomes from histology, but their predictions are shaped by complex, intertwined tissue signals whose roles are important to understand. Common pixel- and feature-space perturbations can produce implausible tissue, making model responses difficult to interpret. We introduce CPathOGen, a conditional latent-diffusion framework for generating paired H\&E counterfactuals with explicit controls over cellular spatial organization, nuclear morphology, and stain appearance. Cellular maps condition spatial structure through a spatial encoder, while a morphology/appearance vector modulates denoising through blockwise feature-wise linear modulation (FiLM). On held-out H\&E tiles, CPathOGen generates visually plausible tissue with improved distributional agreement after spatially guided selection, as reflected by lower Fréchet Inception Distance (FID) and Kernel Inception Distance (KID); generated cells track requested abundance and position, and measured morphology and color vary monotonically with their controls. We use these verified interventions to probe pathology encoders with endpoint heads, task-specific classifiers, and survival models. Responses are quantified using total variation distance and prediction-flip rate. We further introduce the Biology-Nuisance Sensitivity Ratio, a metric that contrasts model sensitivity to biologically motivated morphology and spatial factors with sensitivity to non-biological, stain-related nuisance variation. CPathOGen provides a practical, fidelity-audited framework for evaluating robustness and controlled feature sensitivity in computational pathology model. \href{https://github.com/a12dongithub/PathOGen}{GitHub} and \href{https://huggingface.co/a12donhf/CPathOGen}{Hugging~Face}.

0.29

Annotating anatomy and pathology in the National Lung Screening Trial computed tomography images

eess.IV ·2026-09-09 ·Deepa Krishnaswamy, Vamsi Thiriveedhi, Suraj Pai, David Clunie, Igor Octaviano +4 more
similarity 0.62
Abstract

Large-scale public medical imaging datasets contribute critically to translational research. When accompanied by rich clinical and multi-omics data, they can stimulate exploratory research and enable secondary analyses. Expert annotations of such imaging collections can support the development of new image analysis tools. Continuous enrichment of images with image-derived data makes them more usable for researchers without expertise in image analysis or access to large-scale computational resources. The National Lung Screening Trial (NLST) released a rich longitudinal dataset that includes Computed Tomography (CT) images for over 26,000 patients. We introduce three Digital Imaging and Communications in Medicine (DICOM) formatted datasets, complementing NLST CT images, shared as analysis results in the National Cancer Institute Imaging Data Commons (IDC). Two of those (IDC NLSTSeg and IDC NLSTSybil) contain DICOM-harmonized annotations and extracted measurements (for 581 and 601 NLST patients, respectively) shared earlier using research formats (Sybil and NLSTseg). The third one (TotalSegmentator-CT-Segmentations) contains volumetric segmentations generated using TotalSegmentator and radiomics features for each segment for 26,194 NLST patients.

0.18

Destroy Me: Automatic Artifact Generation for Histopathology Images

eess.IV cs.AIcs.CVcs.LG ·2026-08-27 ·Zuzanna Krawczyk-Borysiak, Adam Krawczyk, Mateusz Miller, Gabriela Kaczmarek, Sławomir Pakuło +2 more
similarity 0.62
Abstract

Deep learning's diagnostic utility in pathology is constrained by model vulnerability to real-world data imperfections. While current strategies favor "perfect data" by filtering low-quality regions, which can lead to the loss of valuable diagnostic context, we propose a paradigm shift: engineering models to thrive in imperfect environments using "Destroy Me", a hybrid framework for realistic artifact synthesis and robust data augmentation. Our approach combines Stable Diffusion, fine-tuned to preserve morphological continuity by realistically integrating artifacts with the underlying tissue architecture, with physics-based procedural modeling to synthesize six common artifact types: tissue folds, precipitates, blur, stitching errors, dust, and pen markers. Artifact fidelity is assessed using Kernel Inception Distance (KID) and color Wasserstein distance metrics. Validating this strategy on lung adenocarcinoma pattern classification with an nnU-Net, we confirm that models trained on "destroyed" patches consistently outperform baselines on independent real-world datasets. Specifically, we observed a 10.5% relative improvement in macro F1-score and a 15% relative increase in the Cohen's Kappa ($κ$) coefficient. Crucially, our results demonstrate that selective, impact-weighted augmentation is vital for balancing practical robustness with the preservation of subtle diagnostic features.

0.23

Which Pretext Task Transfers? Self-Supervised Pretraining Objectives for Lung Ultrasound

cs.CV ·2026-09-15 ·Moein Heidari, Junbo Rao, Jai Choraria, Wenjin Chen, David J. Foran +1 more
code/data similarity 0.61
Abstract · Submitted to SPIE 2027

Self-supervised learning (SSL) can reduce the need for labelled medical images, but the choice of pretext objective remains unclear for lung ultrasound (LUS). Contrastive learning, masked reconstruction, and joint-embedding predictive architectures (JEPA) differ in the space in which their targets are defined, yet existing ultrasound studies compare them under different corpora, backbones, and evaluation protocols. We compare these three objective families using the same encoder backbone, pretraining corpus, optimisation schedule, and frozen-evaluation protocol. Encoders are pretrained on COVID-BLUeS LUS videos and evaluated with linear, $k$NN, and attentive probes at 5\%, 10\%, 50\%, and 100\% label budgets. Evaluation is performed on POCUS using patient-level five-fold cross-validation and on the independently acquired Mendeley-Uganda dataset, which is excluded from both pretraining and probe fitting. At the full label budget under linear probing, VideoMAE and V-JEPA achieve $66.5 \pm 13.1$ and $65.4 \pm 11.7$ balanced accuracy on POCUS, while MoCo achieves $42.1 \pm 1.2$. On Mendeley-Uganda, the ranking reverses: MoCo performs best at $62.7 \pm 1.0$, followed by VideoMAE at $53.8 \pm 2.8$, while V-JEPA falls near chance at $35.1 \pm 4.9$. These results show that POCUS probe accuracy alone does not identify the objective that transfers best across datasets. We also outline planned representation-level analyses to examine this reversal. Code is publicly available at https://github.com/moeinheidari7829/LUSVideoSSL.

0.35

ZAGNet: Zone-Aware Graph Aggregation Network for Patient-Level Lung Ultrasound Diagnosis

eess.IV cs.CV ·2026-10-01 ·Li Chen, Shubham Patil, Rashid Al Mukaddim, Jochen Kruecker, Balasundar Raju +1 more
similarity 0.61
Abstract · The 2026 IEEE International Ultrasonics Symposium (IUS)

Patient-level lung ultrasound (LUS) diagnosis requires integrating findings acquired across multiple anatomical zones, yet clinical examinations frequently involve variable and incomplete scanning protocols with missing zones. Existing diagnostic AI methods primarily analyze individual frames or video loops, relying on heuristic aggregation strategies such as max or mean pooling that ignore inter-zone relationships for patient-level inference. This paper presents ZAGNet, a Zone- Aware Graph Neural Network that represents temporally tracked pathology findings as graph nodes connected by anatomical zone adjacency. A graph transformer network propagates contextual information across neighboring lung regions, while a virtual global node aggregates graph-level features to predict patientlevel consolidation and pleural effusion using only patient-level supervision. ZAGNet accommodates missing zones by computing on a graph structure without fixed input format or size. We evaluate ZAGNet on a multicenter dataset of 714 subjects (20,256 LUS video loops) with exams varying from 4 to 16 zones across anterior, posterior, and lateral thoracic regions. For consolidation diagnosis, ZAGNet achieved an AUC of 0.803 compared to 0.677 (max pooling) and 0.674 (mean pooling). For pleural effusion, AUC increased to 0.893 from 0.804 (max pooling) and 0.815 (mean pooling). These represent improvements of up to 19% and 11% for consolidation and pleural effusion respectively. The results demonstrate that graph-based inter-zone reasoning provides an effective and clinically consistent framework for automated patient-level LUS assessment.

0.22