CS Paper Radar

DiffStent: Surrogate Adjoint Differentiation for Stent Deployment in Anisotropic Arteries

Shoaib A. Goraya, Ajay Manicka, Aviral Jain, Karim Kadry, Samuel Ruiperez-Campillo, Elazer R. Edelman, Farhad R. Nezami

cs.CE physics.med-phmath.NA ·submitted 2026-09-29 20:16 UTC · v1

Abstract

We present DiffStent, a differentiable finite element framework for simulating arterial deformation during in silico stent deployment, where nearly incompressible, anisotropic vessel walls undergo large deformation and frictional contact with the stent. DiffStent combines the fiber-reinforced Holzapfel-Gasser-Ogden constitutive model with an implicit discrete adjoint that differentiates the converged mechanical equilibrium without unrolling the nonlinear solver, thus reducing the memory cost by three orders of magnitude. We identify three mechanisms that can lead to inaccurate, unstable, or uninformative gradients: nonsmooth switching, state mismatch, and gradient cancellation. To address these, we apply a contact surrogate in the backward pass while retaining the original physical model in the forward pass. We show superior gradient accuracy of our method over AutoDiff and finite differencing across constitutive benchmarks, idealized stented vessels, and patient-specific calcified coronary anatomies, and use the resulting sensitivities to quantify how tissue properties and calcification patterns govern lumen expansion and arterial wall stress. Finally, we demonstrate that DiffStent enables gradient-based system identification from retrospective clinical images of atherosclerotic coronary anatomy. Together, these results establish a practical approach for differentiating through nonlinear biomechanical simulations with stiff constitutive laws and nonsmooth contact, enabling patient-specific parameter inference and optimization in computational cardiovascular mechanics.

Closest papers

Nearest neighbours by meaning across the whole index.

Synthetic Dataset Generation, Physical Consistency and Active Learning for Shape-Informed Surrogate Modeling of Hemodynamics

cs.CE physics.flu-dyn ·2026-10-19 ·Francesco Romor, Richard Schussnig, Charles A. Taylor, Gerhard A. Holzapfel, Alfonso Caiazzo
similarity 0.60
Abstract

Model order reduction has the potential to enable real-time patient-specific assessment of cardiovascular flows. However, it still faces significant challenges stemming from the geometric variability of vascular anatomies. Building upon the SynthAorta dataset (Bosnjak et al., IEEE Trans. Med. Imag. 45(1), 2026) of physiological aortic geometries, we generate an extensive dataset of physiologically consistent computational fluid dynamics solutions through an automatic boundary-condition adjustment procedure. A common reference geometry allows all patient-specific anatomies to be represented by displacement fields, providing point-to-point correspondence without the need for geometric registration. Based on this dataset, we develop Graph U-Net and Transformer U-Net surrogate models to predict velocity and pressure fields at peak systole. We further investigate two strategies to enhance data efficiency and prediction accuracy: active learning and differentiable physical consistency constraints based on the finite element residual. The results show that active learning is strongly regime-dependent: while it offers little benefit over random sampling during early training, it improves performance during fine-tuning through gradient- and subspace-based acquisition strategies. Similarly, physical consistency constraints prove to be substantially more effective as a fine-tuning objective than as a regularizer applied throughout training. Finally, out-of-distribution studies demonstrate that the primary limitation of surrogate models lies in the geometric support of the underlying parametrization rather than in the neural network architectures themselves. The proposed framework combines synthetic dataset generation, geometry-aware surrogate modeling, physics-informed optimization, and active learning into a scalable workflow for inter-patient hemodynamic prediction.

0.03

Electrocardiographic Imaging via Posterior Sampling under Operator Discrepancy

cs.LG ·2026-11-13 ·Ricarda Buttmann, Andreas M. Lehrmann
published similarity 0.53
Abstract · Accepted at the GenAI for Health Workshop @ NeurIPS 2026. Code, models and data: https://projects.cairo.thws.de/asml/papers/ecgi/

Electrocardiographic imaging (ECGI) reconstructs heart-surface potentials from body-surface potentials, an ill-posed inverse problem. Diffusion posterior samplers combine a learned prior with an explicit forward operator that they assume to be accurate. In ECGI this operator is only an estimate, because the body changes with respiration and posture, and body composition such as subcutaneous fat is rarely known for an individual patient. The resulting operator discrepancy is structured and depends on the heart signal. We introduce OpDis-PS, a diffusion posterior sampler that models this discrepancy instead of treating it as signal-independent noise. OpDis-PS learns how the discrepancy depends on the signal, folds this into a corrected forward operator, and reconstructs with a fixed prior across all operator conditions. We study two realistic sources of discrepancy, changing lung conductivity and an added subcutaneous-fat layer. Across both, OpDis-PS reconstructs more accurately than classical regularization and learned predictors, with its largest gains on held-out cardiac pathologies.

0.41

Same Physics, Different Gradients: A State-of-the-Art Report on Differentiable Physics Simulation

cs.GR cs.CVcs.LGcs.RO+1 ·2026-11-09 ·Lei Shu, Zizhou Huang, Yunuo Chen, Yifei Li, Tao Du +13 more
similarity 0.52
Abstract · 35 pages, 8 figures, 9 tables

Differentiable simulation propagates derivatives through a physics simulator, turning animation, system identification, control, and computational design into gradient-based optimization. Engines differ in the physics they model and, less visibly, in which mathematical object they differentiate. We separate two questions the literature conflates. The referent is which object the returned derivative belongs to: the finite computation that executed, the converged equation it approximates, or the continuous dynamics. The realization describes the organization of the backward pass: automatically generated differentiation, an equation-level adjoint solve, or a custom adjoint. The referent defines the target against which exactness is assessed; the implementation determines how accurately that target is approximated. Cost depends on the realization together with how the states needed by the backward pass are retained or recovered. Crossing the axes places every method and engine we classify in a cell, separates claims the literature merges, and shows that the apparent trade-off between exactness and memory follows from how methods have been built rather than from a constraint. A second, orthogonal taxonomy covers contact, where the map is non-smooth. We then ask whether a correct gradient helps. Four mechanisms by which useful gradients are lost are cataloged and measured on one testbed, where the advantage of the exact derivative over the equation-level adjoint depends on where the fitting target comes from as much as on the solver budget, and we review the evidence that zeroth-order methods can outperform simulator gradients in the regimes where those mechanisms act. The model classes, systems techniques and applications are surveyed through this lens, and we close with a reporting checklist, a released diagnostic that computes it, and a research agenda.

0.26

Generalizing Soft Tissue Deformation and Force Prediction Across Material Stiffness and Geometry

cs.AI cs.CGcs.CV ·2026-08-21 ·Madina Kojanazarova, Sidaty El Hadramy, Philippe C. Cattin
similarity 0.51
Abstract

Accurate soft tissue simulation is essential for surgical training, pre-operative planning, and haptic feedback systems. While learning-based surrogate models trained on data using the finite element method (FEM) offer a promising path to real-time inference, their reliability depends on well-calibrated constitutive models. Existing approaches neither provide systematic guidance on model selection across stiffness levels, nor generalize across different tissue stiffnesses or geometries. We perform a comprehensive calibration of hyperelastic constitutive models in the SOFA Framework using gravity-loaded silicone beams with different stiffnesses. Using calibrated simulations as training data, we use a softness conditioned equivariant graph neural network, enabling deformation and force prediction across multiple tissue types and unseen geometries. Our model achieves sub-millimeter mean deformation accuracy at 0.010s inference time, while showing that force prediction quality is directly tied to upstream calibration consistency.

0.31

Physics Informed Neural Network model for the dynamical study of Abdominal Aortic Aneurysm

cs.AI physics.flu-dyn ·2026-09-14 ·Adrián Robles Arques, Martín Ruiz Fernandez, Javier Sanchis, Miguel A. Teruel, Juan Trujillo
similarity 0.51
Abstract · 38 pages, 9 figures and 2 tables

We present the development and application of a three-dimensional Physics-Informed Neural Network (PINN) framework for the investigation of haemodynamic behaviour in the human aorta. The model incorporates a time-resolved simulation of pulsatile blood flow over a two-minute interval, enabling the extraction of pressure and velocity fields with high temporal fidelity. The mechanical stress exerted on the aortic wall was quantified through Laplace's law, with temporal averaging applied to derive representative stress distributions. This approach circumvents the computational overhead associated with conventional computational fluid dynamics (CFD) methods by eliminating mesh generation and exploiting the automatic differentiation capabilities inherent to neural networks. The proposed methodology demonstrates that PINNs can serve as an efficient and accurate alternative for modelling complex vascular flow phenomena, offering significant advantages in scalability and computational cost reduction while maintaining physical consistency.

0.20

Semi-Implicit Pairwise Descent for Nonlocal Continuum Mechanics

cs.GR ·2026-09-09 ·Xukun Luo, Xiao Cheng, Yuzhong Guo, Ying Qiao, Wencheng Wang +1 more
top venue similarity 0.50
Abstract

We propose Semi-Implicit Pairwise Descent (SIPD), a unified nonlocal pairwise framework for simulating large-scale hyperelastic materials involving complex contact and friction. By reformulating the Finite Element Method (FEM) equations of motion into a pairwise force representation from a nonlocal perspective, our approach avoids costly Hessian computations, leading to a reduction in per-iteration computational overhead. Furthermore, we propose an analytical projection strategy for projecting our Hessian-free coefficient matrices to positive semi-definiteness. And we treat contact and friction as a unified anisotropic elastic energy, allowing for a seamless integration into the elastic solver framework. We mathematically prove that our method is unconditionally stable and numerically convergent.Experimental results demonstrate that SIPD achieves real-time performance for million-scale simulations even under intricate contact and friction conditions.

0.46

Physics-Informed Hemodynamic Modeling for Data-Free Prediction and Sparse-Data Assimilation

eess.IV cs.AI ·2026-09-16 ·Xi Chen, Jianchuan Yang, Hongde Li, Guangxin He, Qiuyu Ye +3 more
similarity 0.50
Abstract

Clinical decision-making for coronary intervention relies mainly on angiography and fractional flow reserve (FFR). However, angiography is two-dimensional and lacks depth information for 3D lesion characterization, while FFR provides only a single functional index, offering limited hemodynamic insight. Among existing methods, numerical analysis is computationally expensive, whereas learning-based approaches require extensive supervision and often lack physical consistency. To address these limitations, we propose physics-informed hemodynamic modeling, an integrated deep learning framework for 3D coronary blood flow analysis from dual-view angiography. First, an attention-enhanced CNN reconstructs coronary geometry from angiography. The resulting point clouds are then mapped to a reference domain and Fourier-encoded for joint representation. A decoupled network separately predicts velocity and pressure fields, with embedded physical priors enabling efficient transfer across physiological conditions. Across 32 clinical patients evaluated under four flow conditions, the trans-stenotic pressure-drop mean absolute percentage error was 2.02%, while the velocity and pressure relative-L2 errors were 0.054 and 0.023, respectively. Validation against hospital-measured FFR further achieved 93.8% diagnostic accuracy (30/32; exact 95% CI, 79.2%-99.2%). The framework also supports illustrative revascularization comparisons and sparse-data assimilation, with the full angiography-to-hemodynamics pipeline completed within 20 minutes per patient.

0.11

CROPS: Cosserat-Rod-Based Co-Design of Soft Slender Programmable Material Systems for Biomedical Applications

cs.CE cs.RO ·2026-10-16 ·Aaditya Chandrasekhar, Dex Doksoo Lee, Hyunwoo Kwon, Shicheng Li, Wei Chen
similarity 0.50
Abstract · Submitted to Finite Elements in Analysis and Design

Slender structures made of stimuli-responsive materials represent an emerging class of programmable material systems, with applications in soft robotics, minimally invasive surgery, wearable electronics, and deployable structures. In biomedical applications, the on-demand design of slender structures, encompassing both their material layout and actuation, is essential to harnessing their large deformation and multiphysics actuation to meet patient-specific design requirements. However, owing to geometric and material nonlinearities, their structure-actuation-response relationship is highly nonintuitive and computationally demanding. This often makes trial-and-error and conventional design approaches challenging for addressing patient-specific needs. To this end, we present a Cosserat-rod-based design optimization framework for the autonomous design of programmable slender structures. Leveraging the Cosserat rod representation, the end-to-end differentiable framework is demonstrated on two case studies: (i) design of swellable stents that morph to the shape of carotid vessels; (ii) co-design of the remnant magnetization and the applied field of magnetically-active catheters to reduce the force exerted on the patient-specific vessel wall during insertion. Both self-contact and external contact with surrounding structures are accounted for. We consider two actuation mechanism, namely the swelling of gel-elastomer composites and the magnetic actuation of hard-magnetic composites. The proposed framework presents an autonomous design platform of soft slender material systems that support large deformations and multiphysics actuation toward personalized biomedical design.

0.25