CS Paper Radar

Directional Dual-Head Supervision for Real-Time Source-Free Polyp Segmentation

Hai-Dang Nguyen, Nhat-Khoi Le, Huu-Thuan Huynh, Minh-Triet Tran, Trung-Nghia Le

eess.IV cs.CV ·submitted 2026-10-30 18:19 UTC · v1
publishedcode/data

Abstract

Source-free domain adaptation (SFDA) is critical for medical image segmentation as it adapts a model to an unlabeled target domain without accessing source data, thereby preserving data privacy. However, its effectiveness is often limited by confirmation bias: self-training models tend to miss small polyps, hallucinate foreground, and produce imprecise contours. We propose MedRT-SFSeg, a real-time SFDA framework built on a dual-head one-to-one/one-to-many YOLO segmentation architecture. Mask-DHF fuses precision- and recall-oriented predictions into stable pseudo-instances, while DURR uses the sign of pixel-level dual-head disagreement as a directional cue to expand or shrink masks, and additionally recovers missed instances and suppresses hallucinations. Seg-MARD further regularizes feature representations through mask-guided, region-stratified sampling. Experiments on bidirectional adaptation between Kvasir-SEG and CVC-ClinicDB show that MedRT-SFSeg achieves 80.43%/80.77% Dice and 5.53/8.44 mm ASD, improving the non-adapted baseline by 7.7 and 9.8 Dice points while running at more than 62 FPS end-to-end. These results suggest that segmentation-aware dual-head supervision can improve pseudo-label quality without sacrificing real-time inference. Project page: https://danielnguyen-05.github.io/MedRT-SFSeg

Comment
Accepted to MMM 2027

Closest papers

Nearest neighbours by meaning across the whole index.

SymmAdapt: Symmetrical Flow Matching for Source-Free Domain Adaptation in Medical Image Segmentation

cs.CV ·2026-08-23 ·Tal Grossman, Noa Cahan, Hayit Greenspan
published similarity 0.69
Abstract · Accepted at SASHIMI 2026, held in conjunction with MICCAI 2026. To appear in the Springer LNCS proceedings of the MICCAI 2026 Satellite Even…

Domain shift across imaging modalities and acquisition sites remains a significant barrier to the clinical deployment of segmentation models. Source-free unsupervised domain adaptation (SFUDA) addresses this by adapting a pretrained model to an unlabeled target domain without requiring access to sensitive source data. We introduce a novel SFUDA framework built on Symmetrical Flow Matching, a unified generative model that segments an input image and synthesizes a source-like image from a mask within the same learned flow. By initializing inference from a domain-agnostic Gaussian origin, the model preserves structural consistency across domains and grounds predictions in learned anatomy rather than shifted texture statistics. Our pipeline leverages this symmetry to generate reliable pseudo-labels and corresponding source-like synthetic images from unlabeled target data, creating a generative replay buffer that anchors source knowledge during a generative self-training stage that fine-tunes on a joint set of real target and synthetic source-like images. We evaluate on abdominal multi-organ and cardiac segmentation, covering cross-modality MRI<->CT shifts, and multi-site prostate segmentation. Our approach outperforms SFUDA baselines and is competitive with conventional UDA methods.

0.25

Less Is More in the Long Tail: Stage-Adaptive Sample Selection for Annotation-Efficient Dense Prediction

cs.CV ·2026-09-22 ·Xiaofei Du, Lei Zhang, Shuyu Yan, Manning Wang, Zhijian Song
similarity 0.68
Abstract

Deep learning performance generally improves with increasing training data, yet this scaling is fundamentally constrained by annotation cost in large-scale dense prediction tasks with long-tailed category distributions, where pixel- or voxel-level annotation is prohibitively expensive. We propose SASS (Stage-Adaptive Sample Selection), a stage-adaptive data-selection framework for pool-based active learning in long-tailed dense prediction. SASS combines three components: label-free self-supervised gradient scoring, prior-guided category rebalancing with validation-driven feedback, and stage-adaptive acquisition aligned with model training dynamics. This design avoids candidate ground-truth masks during gradient scoring while making acquisition responsive to long-tail imbalance and evolving representations. We evaluate SASS on a multimodal 3D medical segmentation testbed comprising over 100,000 samples spanning 108 anatomical structures. SASS recovers 98.3% of full-dataset performance with a 40% training-pool annotation budget, outperforming BADGE by 5.1 percentage points. Moreover, SASS exhibits a statistically supported less-is-more pattern, surpassing full-dataset training at the Hard-group level and, at the structure level, for the pancreas and gallbladder. More broadly, SASS shows that annotation-efficient learning depends not only on which samples are selected, but also on how the annotation budget is distributed across categories and when model-derived scores begin to guide selection.

0.18

BiCC: Bidirectional Connected-Component Loss for Instance-Aware Segmentation

cs.CV ·2026-09-24 ·Luc Bouteille, Frederic Jonske, Jens Kleesiek, Alexander Jaus
code/data similarity 0.67
Abstract · 2 figures, 3 tables. Code: https://github.com/TIO-IKIM/BiCC-Loss

Common segmentation losses aggregate errors voxel-wise, so lesions influence the objective in proportion to their volume, giving small but clinically critical lesions disproportionately little weight. Instance-aware losses aim to address this mismatch by assigning each lesion its own term. However, blob loss and CC-DiceCE derive their regions solely from annotations, so false-positive components receive no instance-level term. This matters in computer-assisted review, where each false-positive component may require separate inspection, making precision and false-positive burden important alongside recall. We introduce the bidirectional connected-component loss (BiCC), which pairs annotation- and prediction-derived partitions to score predicted components on their own scale. By deriving instances from the predictions, this branch directly penalizes false-positive components regardless of their size. The balance parameter $α$ allows control over the lesion-wise precision-recall trade-off. Across five datasets with five-fold cross-validation using nnU-Net, BiCC outperforms CC-DiceCE in lesion-wise F1 on four datasets and blob loss on all five. It significantly improves over DiceCE on three datasets and matches it on two; CC-DiceCE instead loses up to 0.363 precision by favoring recall. Code is available at https://github.com/TIO-IKIM/BiCC-Loss.

0.48

Fed-ADApt: Federated Anytime Depth Adaptation for Resource-Aware Medical Image Segmentation

cs.CV ·2026-10-02 ·Abhijeet Parida, Zhifan Jiang, Pooneh Roshanitabrizi, Austin Tapp, Maria J. Ledesma-Carbayo +4 more
published similarity 0.67
Abstract · Accepted to The 4th International Conference on Federated Learning Technologies and Applications (FLTA 2026)

Federated learning (FL) enables collaborative training of medical image segmentation models without sharing raw patient data, yet existing approaches assume a homogeneous compute budget across institutions, limiting participation of low-resource sites. We propose Fed-ADApt, a depth-adaptive federated framework for UNet-based segmentation that jointly addresses low-compute training and inference. Fed-ADApt integrates multi-depth supervision with hierarchical depth-wise aggregation, allowing each site to train according to its local compute budget while contributing to a global model that supports dynamic depth selection at deployment. We evaluated Fed-ADApt on multi-site 2D retinal fundus disc segmentation and 3D brain tumor segmentation. Across both tasks, federated collaboration substantially improves robustness under domain shift. Fed-ADApt matched the full-resource FedAvg performance in 3D and achieved competitive 2D performance with a 4.7% average Dice reduction, while reducing average inference cost by 19.5% in 3D and 34.5% in 2D and substantially reducing training cost by 98% at the most constrained sites. Importantly, Fed-ADApt enables low-resource institutions that cannot train full-capacity models to participate in federations while maintaining competitive global performance under a favorable accuracy to efficiency trade-off. By considering training and inference compute budgets, Fed-ADApt provides a practical and equitable solution for federated medical image segmentation across heterogeneous clinical and edge-enabled imaging environments.

0.22

Leveraging Segmentation Representations for Efficient Classification: A Self-Configuring Framework Based on nnU-Net

cs.CV cs.AI ·2026-11-17 ·Renjun Cai, Antonio Javier Gallego, Félix Fuentes-Hurtado
benchmark similarity 0.67
Abstract

We propose a self-configuring framework that extends the nnU-Net workflow to both segmentation and classification in 3D medical imaging. Building on nnU-Net's self-configuring method, the framework reuses representations learned by a segmentation model for image-level classification. Its encoder features and predicted segmentation probabilities are used by a lightweight classifier. Two information-sharing strategies are investigated. In the frozen-backbone branch, features are augmented with region-of-interest information, predicted foreground volume, and segmentation confidence. In the adaptation branch, the final encoder stage is partially fine-tuned for classification, with an auxiliary segmentation loss to preserve segmentation-related information. Additional five-fold experiments showed that more complex configurations did not consistently improve classification performance. On the public validation leaderboard, our selected framework achieved an Overall score of 0.8056. In the official FLARE 2026 Task 2 final evaluation, our framework ranked first overall, achieving the highest DSC, NSD, and AUROC across all four testing tasks, including two hidden testing tasks. Local inference measurements also remained below the challenge limits of $60 \mathrm{s}$ per case and $4 \mathrm{GB}$ GPU memory. These results demonstrate the practical value of reusing segmentation representations for classification while maintaining a simple and efficient framework.

0.13

GazeRefine: Expert Gaze as a Test-Time Prompt for Training-Free Medical Image Segmentation

eess.IV cs.AIcs.CVcs.HC+1 ·2026-09-01 ·Mohammed Oussama Benyahia, Marouane Tliba, Mohamed Amine Kerkouri, Taifour Yousra, Bin Wang +8 more
publishedcode/data similarity 0.66
Abstract · 9 pages, 5 figures. Accepted at MICCAI Workshop 2026

Medical image segmentation remains difficult to scale because high-performing methods typically rely on dense expert annotations and task-specific training. We introduce GazeRefine, a training-free framework that uses gaze as an inference-time prompt for zero-shot medical image segmentation. Sparse, duration-weighted fixations are converted into foreground and background priors that initialize semantic prototypes in frozen DINOv3 feature space. These prototypes are iteratively refined through foreground-background discrimination, feature-space affinity propagation, and anchoring to the initial gaze guidance, allowing segmentation to extend beyond directly fixated regions while limiting semantic drift. GazeRefine requires no segmentation masks, fine-tuning, adapters, prompt encoders, or gradient updates. We evaluate the method on gaze-annotated polyp segmentation and prostate MRI segmentation. The results show strong performance on colonoscopy images and competitive performance on prostate MRI, supporting gaze-guided prototype refinement as a promising approach for segmentation-label-efficient, human-in-the-loop medical image segmentation. Our tools and code can be found in the following repository: https://github.com/MohammedOussamaBEN/GazeRefine.git

0.73

FGCARL: Fisher-Guided Continuously Adaptive Representation Learning for Medical Image Segmentation

eess.IV ·2026-11-12 ·Xiaobing Yu, Jin Yang, Peijie Qiu, Weiwei Ma, Xiaofeng Liu
similarity 0.65
Abstract · 19 pages, 5 figures

Deep learning (DL) has achieved remarkable success in medical image segmentation by learning data-driven representations from large-scale annotated datasets. However, medical images are often collected independently across clinical sites, resulting in substantial domain shifts due to differences in imaging modalities, acquisition protocols, and intensity distributions. Meanwhile, segmentation classes may vary across sites due to differences in annotation standards, leading to class shifts. These evolving domains and class definitions can substantially degrade segmentation performance on newly encountered data, while sequential adaptation may cause catastrophic forgetting of knowledge acquired from previously encountered domains and classes. Existing incremental learning methods for medical image segmentation primarily address either domain shifts or class shifts, with these two settings largely investigated independently. This separation leaves a critical gap in developing a unified approach that can simultaneously adapt to evolving domains and newly introduced classes while retaining previously acquired knowledge. To address this challenge, we propose Fisher-Guided Continuously Adaptive Representation Learning, a unified framework for domain- and class-incremental 3D volumetric medical image segmentation. FGCARL comprises two key components: Mutual Adaptive Instance Representation (MAIR), which adaptively aligns feature distributions across sequentially encountered domains through bidirectional normalization and denormalization, and Fisher-Guided Knowledge Retention (FGKR), which selectively preserves parameters important for previously learned domains and classes through Fisher-guided regularization. Experimental results demonstrate that FGCARL consistently outperformed state-of-the-art methods, effectively adapting to domain and class shifts while mitigating catastrophic forgetting.

0.14

NativeSeg: Native Vision Language Segmentation of 3D Computed Tomography via Spatial Visual Tokens and Verified Local Zoom

cs.CV ·2026-11-18 ·Chengqian Ma, Gaole Dai, Zijie Meng, Weixuan Jin, Yijie Du +3 more
code/data similarity 0.65
Abstract · 13 pages, 5 figures, 4 tables. Code: https://github.com/step-out/NativeSeg ; Weights: https://huggingface.co/ChengqianMa/NativeSeg

Text prompted 3D computed tomography (CT) segmentation requires both full slice context and fine boundary precision across volumes where over $80\%$ of organ prompted slices lack the queried target. Existing medical vision language models (VLMs) are largely non native segmenters: they delegate pixel delineation outside the VLM by compressing reasoning into a 1D [SEG] vector for an external Segment Anything Model (SAM) decoder, quantizing masks into lossy discrete codebooks, or issuing box prompts to stateless external SAM tools without empty slice screening or spatial state memory. We introduce NativeSeg, a native vision language segmentation framework on Low Rank Adaptation (LoRA) adapted Qwen3.8-27B that performs dense mask decoding, volumetric triage, spatial error self diagnosis, and multiround local zoom directly over the VLM's 2D spatial visual tokens without external SAM decoders. NativeSeg decodes confidence maps from upper layer 2D spatial tokens fused with a five slice U-Net pathway, halts at zero zooms on $>91\%$ of standalone evaluations via a native presence gate (<pres>), localizes uncertain boundaries via a 20 cell multiscale error gate (<err>), and accepts zoomed updates only when predicted error decreases. Trained solely on adult CT, NativeSeg improves Round $0$ DSC by $+19.81$ and $+7.04$ points over discrete codebook and 1D [SEG] readouts on the identical backbone, reaches $86.81\%$ adult and $87.04\%$ zero shot pediatric DSC, and safely refines 2D nnU-Net ($89.52\%$ adult; $86.86\%$ pediatric), 3D SegVol ($86.81\%$), and 3D VoxTell ($89.85\%$).

0.44