CS Paper Radar

Detect, Repair and Audit: A Hierarchical Multi-Agent Defense Against Adversarial Attacks in Energy Forecasting

Zewei Shi, Ruoxi Sun, Minhui Xue, Feng Liu, Hua Ma, Xingliang Yuan, Surya Nepal

cs.CR ·submitted 2026-11-02 00:00 UTC · v1

Abstract

Accurate electricity-demand forecasting is essential for the modern energy infrastructure. Recently, Times-Series Large Language Models (TS-LLMs) have emerged as a promising approach to forecasting more accurate demand from historical consumption data in zero- and few-shot settings, helping energy operators effectively plan supply and allocate energy resources. However, these models are vulnerable to compromised sensor inputs that can distort forecasts and lead to erroneous market orders or unnecessary load shedding. Existing defenses focus primarily on end-device forecasting, overlooking the distinct data-drift, latency, and audit requirements across energy infrastructure. To address this gap, we extract from major energy standards and regulatory frameworks a three-layer conceptual model that captures the security postures for each layer. Guided by this model, we develop a Multi-Agent Reinforcement Learning (MARL) detector coupled with signal repair at local control centers, designed to mitigate distributional data drift through complementary feature-based detection and clean-reference-calibrated repair while meeting latency budgets. We further deploy an evidence-grounded LLM auditing agent with human-in-the-loop validation for audit-critical Virtual Power Plants (VPPs). In our evaluation, the best MARL configuration achieves an F1 score above 0.91 across all dataset-attack pairs, while signal repair reduces adversarial-to-clean input Relative Squared Error (RSE) by up to 83%. The few-shot auditor detects 77.78% of attacks in the Sherlock dataset. On the evaluated hardware, detection and repair require 7.95 ms on average, with a worst-observed latency of 14.50 ms, remaining within the local-center latency budget informed by IEEE 1646.

Closest papers

Nearest neighbours by meaning across the whole index.

Agreement Is Not Assurance: Evidence-Independent Safety Gates for Agentic AI in DER-Rich Distribution Grids

eess.SY ·2026-11-11 ·Qianxue Xia
similarity 0.71
Abstract · 10 pages, 3 figures, 4 tables

Physics-based safety gates for large language model (LLM) agents can approve unsafe actions when the agent and gate rely on the same corrupted measurements or network records. We formulate this shared-evidence failure for voltage-constrained distributed energy resource (DER) export decisions and analyze how nearly critical DER telemetry can bias state estimation while evading residual-based bad-data detection. We propose evidence-independent verification (EIV), which combines advanced metering infrastructure (AMI) voltage readings, measurement selection based on predicted voltage rise, and bounded physical probes. An IEEE 123-bus hidden-truth testbed evaluates 1,654 near-limit requests under telemetry attacks and record errors. For telemetry attacks targeting the nominal gate, an AC-twin gate with bad-data detection approved 95% of unsafe requests, compared with 3.1% for EIV; EIV rejected 22% of safe clean requests. At matched false-rejection settings, direct AMI checks outperformed incorporating the same readings into state estimation. Gate-targeted attacks exposed a vulnerability in telemetry-based response prediction. Command-based prediction removed that route, but targeted attacks on fresh validation cases still produced a 20% unsafe-approval rate under the tested attack pool. LLM agents frequently sought independent evidence voluntarily, but injected instructions and phase-label errors caused unsafe decisions. When offered the EIV checker as a tool, they used it in 93-100% of episodes; mandatory use did not reduce observed violations, which primarily reflected checker errors. These results distinguish enforcement of verification from reliability of the verifier itself.

0.27

Learning Defensive Policies against Diverse Inference Attacks for Smart Meter Privacy

cs.LG ·2026-09-21 ·Ruichang Zhang, Mustafa A. Mustafa
similarity 0.68
Abstract

Smart meter (SM) data provides fine-grained visibility into household energy consumption, but also exposes users to privacy risks. Inference attacks, known as non-intrusive load monitoring (NILM), can perform appliance-level inference from aggregate signals and recover sensitive behavioral patterns. In practice, attacker models are unknown and heterogeneous, making robust defense challenging. We formulate SM privacy protection as a black-box inference defense problem, aiming to reduce the recoverability of appliance-level information while generalizing across diverse and unseen attackers. We propose a proxy-guided hierarchical reinforcement learning framework that learns battery-based load-shaping policies to inject realistic but misleading appliance-level signatures into the aggregate signal, thereby disrupting the structured patterns exploited by NILM. A self-supervised aggregate-structure privacy probe provides a reconstruction-error-based surrogate reward for disrupting recoverable load structure, while a signature library makes the perturbations appliance-relevant and physically realizable through battery control. We provide theoretical rationale showing that proxy-guided optimization improves inference robustness under attacker diversity. Experiments on real-world datasets UK-DALE and REDD demonstrate strong cross-model and cross-appliance generalization. Across six unseen NILM attackers, covering four appliances on UK-DALE and five on REDD, our proposed defense increases average appliance-level RMSE by 107% and 166%, respectively, while reducing F1 score by 79% and 80%.

0.16

LogiC-Diff: Embedding Security Properties Into AI-Enabled Cyber-Physical Systems

cs.CR cs.AI ·2026-09-29 ·Ziyan An, John Stankovic, Meiyi Ma
similarity 0.67
Abstract

AI-enabled Cyber-Physical Systems (CPS) are highly vulnerable to adversarial and anomalous inputs, where small perturbations can induce cascading errors and unsafe control actions. Existing approaches, such as rule-based filtering, training-time regularization, or diffusion-based reconstruction, either operate outside the model or lack mechanisms to incorporate formal security specifications into the prediction process. In this paper, we take the first step toward embedding security properties directly into AI-enabled CPS, enabling predictive models to enforce system-level constraints during inference rather than relying on external defenses. We introduce a logic-conditioned bi-stage diffusion framework that integrates Signal Temporal Logic (STL) specifications into forecasting. STL serves as a first-class conditioning signal that guides both an input repair stage and an output refinement stage, allowing the model to jointly mitigate adversarial perturbations and enforce desired temporal behaviors to satisfy security-critical properties. We evaluate our approach on two real-world multivariate CPS forecasting datasets under a diverse set of physical sensor and cyber attacks. Across sensor faults, gradient-based attacks, adaptive attacks, and varying attack strengths, our method consistently improves robustness and specification compliance, degrades more gracefully as attack strength increases, and generalizes better to unseen attacks. Ablation studies on specification coverage and quality further show that embedding logical security properties yields gains unattainable by reconstruction-based methods alone, highlighting a new direction for integrating formal methods with generative models in secure CPS.

0.24

GridAnchor: Specialized Multi-Agent AI for Safeguarding Autonomous Energy Systems Against Cyber-Physical Hallucinations

cs.MA ·2026-11-18 ·Abderaouf Bahi, Hasan Masrur
similarity 0.65
Abstract

Autonomous energy systems increasingly chain specialized learned agents, such as a forecaster, a state estimator and a dispatcher that may be a language model. These agents can emit confident outputs that contradict physics, and downstream agents may act on them. We define such cyber-physical hallucinations and their cascades, organize them in eight types, and build CPH-Bench, a generator of labeled episodes on SimBench feeders. We propose GridAnchor, a verification layer whose Physics-Residual Graph Transformer scores every claim from residuals between the claims, the measurements and a linearized grid model. Mondrian conformal p-values with the Benjamini-Hochberg procedure turn the scores into decisions, a root head attributes cascades, and a quadratic program repairs unsafe actions with a voltage margin calibrated at repaired steps. On a simulated rural medium-voltage feeder, GridAnchor reaches a message-level area under the precision-recall curve of 0.846, against 0.837 for the strongest of six baselines, a difference within the confidence interval. It leads on estimates and actions, whereas a self-consistency check that knows the label tolerances reaches 0.874 by leading on forecasts. The false-alarm rate stays within 0.17 percentage points of the nominal level on steps without injected hallucinations. In closed loop, GridAnchor leaves no bus outside the voltage band on the test days, against 0.0700% of the bus-steps without protection, and simpler detectors with the same mitigation come close. Stale but coherent messages and single-bus forecast errors remain mostly undetected.

0.32

Validated Data Onboarding for AI Demand Forecasting on U.S. Building Meter Data: Design, Controlled Evaluation, and a Corrected Negative Result

cs.LG ·2026-10-01 ·Yixuan Liang
code/data similarity 0.65
Abstract · Technical report; 8 pages, 5 figures, 2 tables. Code, data manifests, and reproducibility artifacts: https://github.com/LIANGYIXUAN3335/ener…

Electric utilities and grid operators increasingly rely on machine-learning models to forecast next-day demand, and those models learn from meter data that is routinely defective: readings go missing, sensors freeze, buildings read zero for hours, and units change by a factor of 100. This report presents a data-onboarding pipeline that detects and repairs such defects before a model is trained, using only information available at forecast time, and a controlled experiment that measures whether the pipeline protects a 24-hour-ahead forecast. On hourly electricity data for twelve U.S. buildings from the public Building Data Genome 2 dataset (210,528 rows, 2016-2017), seeded, hash-logged defects touching 0.10% of the training period raised the error of a gradient-boosting forecaster by 86%; after detection and past-only repair the error returned to the clean-data level (mean absolute scaled error 0.760 clean, 1.415 corrupted, 0.729 repaired) while 93% of training targets were retained. At a defect prevalence calibrated to published field studies (1.6% of training rows) the unprotected forecaster's error reached 4.4 times that of a seasonal-naive rule, and the repaired forecaster again matched the clean baseline. The same pattern held for ridge regression and a random forest and across horizons of 1 to 24 hours. A first version of the pipeline over-cleaned natural data and made forecasts 25% worse; that result is retained, its cause is traced in the published artifacts, and the per-building calibration that corrects it is documented as a dated amendment. Every number is reproducible from pinned public inputs with SHA-256 verification, 84 automated tests and continuous integration.

0.40

Thermal-Guided Ensemble Reinforcement Learning for Regime-Adaptive Short-Term GPU Power Forecasting in AI Data Centers

eess.SY ·2026-11-19 ·Yuanshuo Zhang, Ying Zhang, Ziying Wang, Fanping Sui
similarity 0.65
Abstract

AI data centers (AIDCs) introduce bursty and regime-dependent load patterns, posing significant challenges for reliable energy management and predictive grid control. To address these challenges, this letter proposes a thermal-guided ensemble reinforcement learning framework for probabilistic AIDC load forecasting. A soft actor-critic (SAC) agent with a simplex-preserving policy adaptively weights LSTM, TCN, and Transformer predictors at every time step based on their realized errors. A thermal-guided neural correction estimates the ensemble residual, while a sensitivity-projection regularizer enforces the non-negative sensitivity of power to GPU utilization and temperature. The corrected ensemble output is further processed by a Bayesian probabilistic layer to produce predictive distributions and quantify forecasting uncertainty. Case studies on 1-second MIT Supercloud telemetry show that the proposed method reduces the normalized mean absolute error to about 1% across all computing regimes, compared with 4-11% for deep learning-based and ensemble learning benchmarks, and converges faster with narrower prediction intervals than a DRL ensemble without thermal guidance.

0.21

ROAM: Reinforcement Learning Optimized Adaptive Moving Target Defense for Smart Grid

eess.SY ·2026-10-08 ·Mohammad Zakaria Haider, Prabin Mali, Muhammad Nadeem, Sumit Paudyal, Fei Ding +1 more
similarity 0.64
Abstract · This manuscript is under submission at IEEE TIFS

Smart grids rely on distributed phasor measurement units (PMUs) and wide-area communication networks whose data-acquisition pipelines are vulnerable to stealthy false data injection (FDI) attacks that evade conventional bad-data detection (BDD). Moving target defense (MTD) counters this exposure by continuously remapping sensor identities, but existing schemes apply static or pre-scheduled randomization and are each constrained by a single failure mode: seed-based methods are fast yet fragile to key compromise, while machine learning (ML) based prediction methods are resilient yet incur prohibitive latency. Neither adapts its randomization to live threat evidence. This paper presents ROAM, a deep reinforcement learning (DRL) driven MTD framework in which a deep Q-network (DQN) agent continuously re-optimizes the sensor-to-ID mapping at the aggregation layer. At each decision step, the agent selects the deception coverage, flags the specific sensors to remap, and sets the split of the remapped sensors between seed-based and ML-prediction-based recovery, without modifying PMU hardware and while preserving IEEE C37.118 compatibility. On held-out BDD-compliant FDI scenarios across the IEEE 14-, 57-, and 118- bus systems, ROAM keeps the percentage of stealthy attacks below 3% while sustaining detection rates above 93%. Against an adaptive soft actor-critic (SAC) attacker that observes the defender's configuration, ROAM keeps stealthy attacks below 2.6% with detection above 92%. Hardware-in-the-loop testing on an OPAL-RT platform confirms real-time feasibility, with sub-18ms average shuffle execution and an average reshuffle blind window of 2.6% of the 3-s decision cycle.

0.29

Stealthy, High-Impact False Data Injection Attacks in Smart Grid Using Physics-Constrained GAN with Limited System Knowledge

cs.LG eess.SY ·2026-11-11 ·Md. Mainul Islam, Hasan Kurban, Abdulrahman Takiddin, Muhammad Ismail, Rachad Atat +1 more
hot direction similarity 0.64
Abstract · 11 pages

False data injection (FDI) attacks can distort power system state estimation while retaining plausible measurement patterns. Existing FDI methods trade stealth for impact or vice versa. They often assume access to internal grids, all-bus sensing, or defender models. In this paper, we propose a detector-agnostic physics-constrained generative adversarial network (PCGAN) that learns decoupled power-flow sensitivities from historical measurements of deployed sensors. The learned active-power-angle and reactive-power-voltage-magnitude relationships guide perturbations restricted to compromised channels, while adversarial training promotes realistic spatiotemporal patterns. We implement PCGAN and seven existing FDI attacks on the IEEE 300-bus system using one year of observed hourly demand from PJM Interconnection, a regional transmission organization in the United States, and synthetic bus-level load profiles. We compare their performance across 10%, 30%, 60%, and 100% compromised sensors. Attack stealth is assessed against ten machine-learning (ML) detectors and conventional bad-data detection (BDD) methods, while physical impact is quantified through nonlinear alternating-current weighted least-squares state estimation. PCGAN achieves 84.28% mean ML evasion and 22.31% mean spatial load misperception across the four scenarios. Its mean stealth-impact trade-off score reaches 18.69%, compared with 5.61% for the strongest competing attack. PCGAN also achieves 83.45% chi-square BDD evasion and 86.02% largest-normalized-residual BDD evasion. These results demonstrate a favorable stealth-impact balance under varying sensor-access levels and provide challenging attack cases for evaluating FDI detectors.

0.21