CS Paper Radar

Stealthy, High-Impact False Data Injection Attacks in Smart Grid Using Physics-Constrained GAN with Limited System Knowledge

Md. Mainul Islam, Hasan Kurban, Abdulrahman Takiddin, Muhammad Ismail, Rachad Atat, Erchin Serpedin

cs.LG eess.SY ·submitted 2026-11-11 07:58 UTC · v2
hot direction

Abstract

False data injection (FDI) attacks can distort power system state estimation while retaining plausible measurement patterns. Existing FDI methods trade stealth for impact or vice versa. They often assume access to internal grids, all-bus sensing, or defender models. In this paper, we propose a detector-agnostic physics-constrained generative adversarial network (PCGAN) that learns decoupled power-flow sensitivities from historical measurements of deployed sensors. The learned active-power-angle and reactive-power-voltage-magnitude relationships guide perturbations restricted to compromised channels, while adversarial training promotes realistic spatiotemporal patterns. We implement PCGAN and seven existing FDI attacks on the IEEE 300-bus system using one year of observed hourly demand from PJM Interconnection, a regional transmission organization in the United States, and synthetic bus-level load profiles. We compare their performance across 10%, 30%, 60%, and 100% compromised sensors. Attack stealth is assessed against ten machine-learning (ML) detectors and conventional bad-data detection (BDD) methods, while physical impact is quantified through nonlinear alternating-current weighted least-squares state estimation. PCGAN achieves 84.28% mean ML evasion and 22.31% mean spatial load misperception across the four scenarios. Its mean stealth-impact trade-off score reaches 18.69%, compared with 5.61% for the strongest competing attack. PCGAN also achieves 83.45% chi-square BDD evasion and 86.02% largest-normalized-residual BDD evasion. These results demonstrate a favorable stealth-impact balance under varying sensor-access levels and provide challenging attack cases for evaluating FDI detectors.

Comment
11 pages

Closest papers

Nearest neighbours by meaning across the whole index.

Adversarially-Informed Node Criticality Identification in Power Grid Measurements

eess.SY math.OC ·2026-08-27 ·Koto Omiloli, Olugbenga Moses Anubi
similarity 0.76
Abstract

Power grid state estimation relies on sensor measurements that are increasingly vulnerable to adversarial corruption in cyberphysical environments, potentially leading to significant deviations in system observations. This motivates the need to identify critical measurement nodes whose compromise results in the most severe system-level impact. However, existing node criticality methods primarily rely on structural or steady-state analyses and do not explicitly account for adversarial effects on system behavior. To address this gap, this paper proposes an adversarially informed framework for identifying critical measurement nodes in linearized power systems. Within this framework, a structured attack generation mechanism is developed to construct stealthy and effective false data injection attacks (FDIAs) against an H-infinity resilient state estimator. Node criticality is then evaluated using coalition-based marginal contributions of compromised sensor subsets, estimated via permutation sampling over a prescribed set of admissible nodes, with the resulting importance scores mapped to the corresponding physical buses. Simulation results on the IEEE 14-bus system show that adversarially identified nodes induce larger deviations in frequency, voltage angle, and net power compared to randomly selected nodes, demonstrating the effectiveness of the proposed framework.

0.23

Topology-Transferable Detection of Deep-Learning False Data Injection Attacks Through Residual-Energy Separation

eess.SY ·2026-11-15 ·Yichen Liu, Hongyu Wu, Bo Liu
positiontheory similarity 0.68
Abstract

Deep learning (DL) false data injection (FDI) attacks can evade both bad data detection (BDD) and data-driven (DD) detectors in AC power system state estimation (SE), and DD detectors lose effectiveness after a topology change unless they are retrained. We argue that BDD fails in its decision rule, not in its statistic. A reconstruction-based DL generator pursues stealth by fitting the measurements closely, and because such a generator tends to act as a denoiser, the attacked residual energy can fall into the lower tail that BDD never inspects. The weighted-least-squares (WLS) residual applies the same projector construction to the noise and to the attack error, and under a spectral suppression condition we prove that the expected residual energies of normal and attacked measurements are separated by a topology-independent margin. Empirically, a rule learned on the residual energy at one topology transfers without retraining and keeps mean cross-topology F1 above 0.98 on the IEEE 14-bus, 39-bus, 57-bus, and 118-bus systems, while a raw measurement DD detector collapses.

0.13

GENADA: efficient generative time series adversarial attack framework

cs.LG ·2026-08-12 ·Michael Baronov, Denis Vorobev, Margarita Rusanova, Petr Sokerin, Alexey Zaytsev
similarity 0.67
Abstract

Deep learning models are widely used for time series analysis in domains such as healthcare, finance, energy systems, and environmental monitoring. However, these models remain vulnerable to adversarial attacks, where small input perturbations cause severe degradation in predictive performance. Commonly used gradient-based attacks, iterative first-order methods, are computationally burdensome, as they repeatedly backpropagate through the victim model to compute input gradients during a number of iterative refinement steps. We propose a GENerative ADversarial Attack (GENADA) that learns a generative model to produce deceptive perturbations directly in a single forward pass and a procedure to train it. Variants include single-step and iterative generative attack schemes. The validation considers attacks on several neural models and datasets in the time-series domain, a controlled, low-dimensional setting. Empirically, GENADA achieves comparable attack quality to strong baselines while requiring less time to generate perturbations during inference.

0.04

Learning Defensive Policies against Diverse Inference Attacks for Smart Meter Privacy

cs.LG ·2026-09-21 ·Ruichang Zhang, Mustafa A. Mustafa
similarity 0.65
Abstract

Smart meter (SM) data provides fine-grained visibility into household energy consumption, but also exposes users to privacy risks. Inference attacks, known as non-intrusive load monitoring (NILM), can perform appliance-level inference from aggregate signals and recover sensitive behavioral patterns. In practice, attacker models are unknown and heterogeneous, making robust defense challenging. We formulate SM privacy protection as a black-box inference defense problem, aiming to reduce the recoverability of appliance-level information while generalizing across diverse and unseen attackers. We propose a proxy-guided hierarchical reinforcement learning framework that learns battery-based load-shaping policies to inject realistic but misleading appliance-level signatures into the aggregate signal, thereby disrupting the structured patterns exploited by NILM. A self-supervised aggregate-structure privacy probe provides a reconstruction-error-based surrogate reward for disrupting recoverable load structure, while a signature library makes the perturbations appliance-relevant and physically realizable through battery control. We provide theoretical rationale showing that proxy-guided optimization improves inference robustness under attacker diversity. Experiments on real-world datasets UK-DALE and REDD demonstrate strong cross-model and cross-appliance generalization. Across six unseen NILM attackers, covering four appliances on UK-DALE and five on REDD, our proposed defense increases average appliance-level RMSE by 107% and 166%, respectively, while reducing F1 score by 79% and 80%.

0.16

Interpretable Cyber-Physical Attack Detection in Smart Grids: A Leakage-Controlled Multi-Testbed Evaluation of Fusion, Robustness, and Observability Limits

cs.LG cs.AIcs.CR ·2026-11-07 ·Muhammad Ridwanul Hoque, Sarah Sharif, Reza Saeed Kandezy, Yaser Banad
code/data similarity 0.64
Abstract

Cyber-physical smart-grid detectors are typically treated as black boxes and validated exclusively on clean, temporally shuffled datasets, which risk overly optimistic performance claims. This work presents a multi-testbed evaluation study built around an interpretable, time-windowed fusion Random Forest, adopting the pessimistic result whenever evaluation protocols disagree. (i) On a public paired cyber-physical dataset, shuffled cross-validation is optimistic: macro-F1 falls from 0.96 to 0.88 +/- 0.06 under rolling-origin temporal evaluation. A topology-free graph convolutional network (GCN) serving as a control confirms that this lightweight model is competitive on these splits. (ii) The adaptive and adaptive-joint feature-space attacks, which are infeasible as realistic grid manipulations, degrade macro-F1 to 0.67 and 0.34, respectively. Adversarial training and randomized smoothing partially restore performance, and a physics-constrained evolution-strategy evasion on the IEEE 14-Bus testbed shows the same vulnerability pattern. (iii) On real IEC-104 traffic, the cyber view reliably catches structural attacks (recall of 0.87 to 0.98) but largely fails on semantic value manipulation (recall of 0.11 to 0.35). An observability taxonomy on the IEEE 14-Bus system reveals that stealthy false data injection defeats all three observation views. (iv) On a full AC weighted least-squares state-estimation testbed, a forecasting-aided temporal test is evaded by slow ramps precisely where a rate-invariant physics-manifold test sustains detection at a common 5% false-alarm target. A full end-to-end evaluation on IEEE 118-Bus confirms the ordering but bounds its strength: the manifold test detects every trial down to 0.05 degree/step and 0.48 at 0.02 degree/step, against 0.14 for the temporal test. All code and benchmarks are released.

0.38

Faults That Fortify: CNN Adversarial Robustness via GPU Undervolting

cs.LG cs.ARcs.CR ·2026-08-20 ·Behnam Omidi, Ahmad Tahmasivand, Husam Alsyouri, Saba Al-Sayouri, Chongzhou Fang +2 more
similarity 0.64
Abstract · 6 pages, 4 figures, 1 table. Submitted to IEEE HOST 2027

Convolutional Neural Networks (CNNs) face a dual challenge: vulnerability to adversarial attacks and prohibitive training cost. Adversarial training is effective but expensive, a burden that grows as learning shifts to the energy-constrained edge. This paper addresses both through GPU undervolting during training. Reducing supply voltage introduces stochastic perturbations that act as implicit regularization, improving robustness while lowering power. We characterize undervolting-induced faults at the bit level, then train LeNet, VGG-6, and MobileNetV3 on MNIST and CIFAR-10 under two training regimes, standard and adversarial, each at nominal and undervolted voltage, and evaluate all models against adversarial attacks. In both regimes, the undervolted model consistently achieves higher adversarial accuracy than its nominal-voltage counterpart, showing that hardware-induced faults strengthen even adversarial training. Because dynamic power scales quadratically with supply voltage, these robustness gains arrive with substantial energy savings. GPU undervolting is therefore a readily deployable hardware-level defense requiring no algorithmic change, and opens a promising direction in which robustness and energy efficiency move together.

0.38

A Defense-Aware Explainable AI Framework for Feature-Level Vulnerability Analysis in Optimal Power Flow

cs.CR ·2026-10-28 ·S. M. Monzurul Hoque Chowdhury, Qinghua Li, Jianhui Wang
similarity 0.64
Abstract

Optimal power flow (OPF) is a foundational analysis in power system operation, and inaccuracies in OPF decision-making can result in significant operational and security consequences. With the increasing adoption of machine-learning-based OPF surrogate models for real-time and large-scale applications, power system operation has become more susceptible to cyber threats, including data manipulation and false data injection attacks. Explainable artificial intelligence (XAI), particularly Shapley value-based approaches, has been employed to quantify the influence of input features on OPF outputs. Features exhibiting high influence are commonly interpreted as vulnerable. However, this interpretation neglects the role of attack detection mechanisms in the system, which typically monitor input-to-input relationships to detect anomalous behavior. Consequently, highly influential features may be readily detectable and may not represent the most vulnerable attack surfaces. To address this limitation, we propose a defense-aware explainable AI framework that explicitly incorporates attack detectability alongside operational impact. The framework integrates an OPF surrogate model representing input-to-output dependencies with a vanilla autoencoder representing input-to-input dependencies. Shapley-based explainability is applied to both models to construct a feature-level vulnerability metric. Empirical evaluation on IEEE test systems demonstrates that the proposed framework more accurately identifies security-relevant vulnerabilities than conventional OPF-surrogate-model-only explainability approaches.

0.11

Data4Cyber: Labeled Cyber-Physical Datasets for Distribution-Grid Management Systems Under Representative OT Attacks

cs.CR ·2026-11-10 ·Ömer Sen, Lennart Bader, Marawan Emara, Martin Serror, Benedikt Schwalm +4 more
published similarity 0.64
Abstract

Cyberattacks against power systems increasingly exploit industrial communication and control dependencies arising from distributed energy resources (DER), remote management, and market-based incentives. Progress on intrusion detection is constrained by a lack of public datasets that align operational technology (OT) network telemetry with physical measurements and control context. Data4Cyber is a labeled cyber-physical dataset recorded in a laboratory distribution management system (DMS) for self-consumption optimization with photovoltaic generation, battery storage, controllable loads, and substation metering. It captures synchronized process measurements, controller context, price incentives, and packet captures (Modbus/TCP and MQTT) across one benign baseline and six attack scenarios spanning protocol-semantic Modbus manipulation, man-in-the-middle (MitM) false-data injection, and MQTT price manipulation. Its fixed 1 s time base, phase-resolved labels, and state-oriented representation support temporally blocked stateful-detector evaluation. Baseline results show that high recall alone is insufficient: several detectors achieve sensitivity through alarm saturation. Context-driven attacks require process-aware interpretation rather than single-channel thresholding.

0.63