CS Paper Radar

Multimodal Prompt Learning with Dual-Granularity Contrastive Alignment for Preoperative Prediction of Lung Adenocarcinoma Invasiveness Using 3D CT

Qing Huang, Xiaotong Tan, Lintong Yao, Wufeng Xue, Ruobing Huang, Dong Ni, Hao Wu, Tian Xiao, Jun Cheng

cs.CV cs.AI ·submitted 2026-11-02 13:28 UTC · v1

Abstract

Accurate preoperative prediction of lung adenocarcinoma invasiveness is important for surgical planning and individualized treatment. However, overlapping CT appearances make it challenging to distinguish invasive adenocarcinoma (IAD) from Pre-IAD lesions. We propose a multimodal prompt-learning framework with dual-granularity image-text alignment for 3D CT-based IAD classification. A 3D ResNet-CBAM encoder extracts global and spatial visual features. A frozen RadBERT backbone is adapted with separate learnable prompts for report-level and keyword-level text encoding. These prompts are initialized using semantic representations derived from real-world clinical reports. Global contrastive alignment connects whole-volume CT representations with reports generated from clinician-annotated radiological attributes to provide overall semantic supervision. A multiple instance learning-based local alignment module associates spatial CT features with vascular-focused radiological keywords, to capture local imaging characteristics potentially associated with tumor invasion. The framework jointly optimizes classification and alignment objectives, while inference requires only CT images. Experiments included 1,593 pathologically confirmed nodules. On the test set, the proposed method achieved an accuracy of 87.92%, F1-score of 87.78%, and AUC of 0.9499. Its AUC significantly exceeded that of the image-only Res-CBAM baseline with the same visual backbone (0.9297; DeLong test, p = 0.0078). Ablation analyses supported the complementary contributions of global and local alignment and the benefit of report-based prompt initialization. Qualitative visualizations showed activation within nodules and adjacent vascular structures. These findings suggest that dual-granularity radiological supervision can enhance CT-based invasiveness prediction while preserving a CT-only inference workflow.

Closest papers

Nearest neighbours by meaning across the whole index.

CRUX: Clinical-Text Anchoring for Cross-Institutional CT-Pathology Fusion in Non-Small Cell Lung Cancer Survival Prediction

eess.IV ·2026-10-15 ·Kyungwon Kim, Dosik Hwang
similarity 0.71
Abstract · 15 pages, 5 figures, 6 tables. Preprint. Extended version of a MICCAI 2024 paper (Kim et al., 2024)

Accurate prognosis in non-small cell lung cancer (NSCLC) benefits from integrating computed tomography (CT) and histopathological whole-slide images (WSIs), which capture complementary macroscopic and microscopic disease characteristics. Fusing these modalities is difficult: their features come from different pretrained foundation-model encoders and lack spatial correspondence, and both are sensitive to institution-specific acquisition and staining, causing multimodal models to overfit site-specific artifacts and generalize poorly. We present CRUX (CRoss-modal Unification via teXt anchoring), a fusion framework that uses clinical text---encoded by a biomedical language model---as an institution-invariant semantic anchor. Because clinical variables follow standardized classification systems, their embeddings occupy a representation space that is consistent across institutions, providing a stable reference frame for aligning heterogeneous imaging features. CRUX introduces a text-mediated cross-modal bridge in which CT- and pathology-derived text-query summaries exchange information within a compact text semantic space through a learnable hub token, avoiding direct image-space cross-attention that would propagate domain-specific artifacts. We evaluate on 2,157 NSCLC patients from five hospitals, holding out one hospital (N=446) entirely for external validation. CRUX attains an external concordance index (C-index) of 0.761, the highest among all unimodal, bimodal, and trimodal configurations. Notably, direct CT-WSI fusion degrades under distribution shift, whereas text anchoring restores and improves cross-institutional generalization. These results indicate that language-model-encoded clinical text is an effective structured prior for robust, generalizable multimodal cancer prognosis.

0.12

Findings-aware Language-Image Pretraining for CT Volume Interpretation

cs.CV physics.med-ph ·2026-11-02 ·Takuro Shimaya, Junya Inoh, Masahiro Saiko
published similarity 0.70
Abstract · 10+2 pages, accepted to WACV2027

Computed tomography (CT) provides diverse patient information and various clinical tasks, for which numerous deep learning models have been investigated. Recent years have seen the development of vision-language foundation models that can comprehensively extract clinical features, driven by representation learning that combines CT volumes with radiology reports. Existing approaches typically adopt Contrastive Language-Image Pre-training (CLIP)-based representation learning, where pairs from different cases are, in principle, treated as negative pairs such that the volume and report embeddings are pushed apart. In the biomedical imaging, however, treating different cases as negative pairs is not always appropriate, particularly when clinical similarity exists. In this study, we propose a supervised representation learning framework grounded in clinical knowledge from language foundation models, rather than the weak supervision used in CLIP. Specifically, we utilized a large language model to extract abnormal finding phrases from reports. We then explicitly constructed the target features that the image encoder should output, as the semantic representation of the extracted findings using a biomedical text embedding model. Our Findings-aware Language-Image Pre-training (FiLIP) outperformed weakly supervised approaches in multi-label zero-shot finding classification in both in-domain and external-domain evaluations, and also proved effective when fine-tuned for the downstream task of radiology report generation.

0.34

COGENT: Counterfactual Gaussian Explanations for Volumetric Medical Images

cs.CV ·2026-08-11 ·Dorian Rząsa, Bartosz Zabdyr, Krzysztof Piekarz, Jakub Grzywaczewski, Bartlomiej Sobieski +5 more
similarity 0.70
Abstract

Explainability is essential for deploying deep learning models in high-stakes medical applications. Existing explainability methods for volumetric imaging predominantly operate in voxel space, overlooking the structured representations introduced by recent advances in 3D scene modeling. We present COGENT (Counterfactual Gaussian Explanations), a framework that generates counterfactual explanations directly in the parameter space of Gaussian-based volumetric representations. Built upon MedGS and the Sybil lung cancer risk prediction model, COGENT optimizes selected Gaussian primitives through a differentiable rendering pipeline, enabling gradients from the downstream predictor to identify representation components that most influence model decisions. Unlike conventional pixel- or voxel-level attribution methods, our approach formulates explainability as a counterfactual optimization problem over an explicit 3D scene representation, producing sparse and spatially localized explanations while preserving anatomical consistency. We evaluate COGENT on lung CT scans using quantitative comparisons with existing explainability methods together with qualitative analysis by medical experts. The results demonstrate that representation-space counterfactual optimization provides clinically meaningful explanations while offering a new perspective on interpreting volumetric deep learning models.

0.04

RepConTUR: A Report-Conditioned Volumetric Multimodal Model for Abdominal Tumor Segmentation

cs.CV ·2026-10-29 ·Seunghwan Lee, Sangjoon Park, Jongmin Lee, Yoon Jo Kim, Wonyoung Cho +2 more
code/data similarity 0.70
Abstract · Submitted to CVPR 2027

Tumor delineation is required for radiotherapy planning, yet automatic segmentation is limited by errors, predominantly false positives, that distort dose and increase editing time. The radiology report accompanies the scan and localizes disease at the suborgan level, but existing text-promptable models condition on short referring phrases, and most operate in 2D. We present RepConTUR, a single native-3D early-fusion multimodal model that conditions volumetric abdominal tumor segmentation on the narrative report. We extend AbdomenAtlas 3.0 to a suborgan-level promptable segmentation dataset and generate report-based VQA pairs, yielding four report-derived tasks on the same annotations: referring segmentation (RES), report-grounded segmentation (GSEG), report generation (RRG), and visual question answering (VQA). We train RepConTUR, comprising a 3D CT encoder, an early-fusion language model, and a native-3D segmentation module, jointly on the four tasks. Across liver, kidney and pancreas, RepConTUR attains the highest Dice similarity coefficient (DSC), instance-wise precision, and detection F1 among the text-promptable baselines, and adding the report raises mean precision while leaving recall comparable. Against two vision-only specialists, nnU-Net and the report-supervised R-Super, RepConTUR attains the highest value on every in-domain metric for liver and pancreas and the highest mean DSC, recall, precision, and detection F1 over the four out-of-distribution public cohorts. Ablations indicate that conditioning on the narrative report raises detection F1 from 0.499 to 0.528 within the same model, that joint GSEG training raises RES F1 from 0.450 to 0.482, and that the native-3D segmentation module raises GSEG F1 from 0.139 to 0.528 over its 2D counterpart. Code is available at https://github.com/Oncosoft-Research/RepConTUR.

0.20

Beyond Classification: Structured Supervision Aligns Visual Evidence with Medical Semantics

cs.CV ·2026-09-05 ·Hexiang Bai, Hanyang Xu, Xiaoxue Li, Xiaoliang Wu, Shangde Gao +2 more
published similarity 0.69
Abstract · 22 pages,7 figures,Accepted to BMVC 2026

Vision Transformers (ViTs) have shown immense potential in medical image analysis. However, standard pre-training via global image classification suffers from spatial collapse, where models rely heavily on background shortcuts rather than localising critical foreground lesions. To overcome this limitation and align visual evidence with precise medical semantics, we systematically investigate alternative pre-training paradigms.Specifically, we evaluate three independent forms of structured supervision: topological priors via graph self-supervision, dense pixel-level constraints via segmentation, and cross-modal semantic grounding via image-text pairs. Notably, our empirical analysis reveals that while all three forms of structured supervision successfully alleviate the global pooling bottleneck and steer visual attention towards foreground regions, image-text alignment achieves the most superior performance. By embedding high-dimensional diagnostic logic, the cross-modal approach not only anchors attention on precise visual evidence but also enables profound abstract reasoning. Extensive experiments demonstrate that this semantically enriched pre-training fundamentally enhances the model's feature representation. Consequently, when fine-tuned for downstream clinical classification tasks, our models achieve superior accuracy and yield highly interpretable attention maps focused on true pathological features, vastly outperforming vanilla classification baselines.

0.32

CGSM: Concept-Guided Segmentation Model for Precise Pulmonary Lesion Delineation

cs.CV ·2026-09-07 ·Changheng Lin, Wenjie Zhang, Yushan Lu, Xinyue Yan, Xiao Jia +1 more
similarity 0.69
Abstract

Accurate segmentation of pulmonary lesions is essential for effective clinical diagnosis and treatment strategies. Existing segmentation approaches often lack task-specific semantic guidance, as text-based annotations typically offer coarse localization of lesions, leading to inadequate delineation of lesion boundaries and poor performance on small-scale lesions. To address this, we propose CGSM, a Concept-Guided Segmentation Model that integrates LLM-generated and clinically reviewed concepts into the segmentation process. Specifically, we design a Concept-Visual Alignment Module (CVAM) to activate relevant tokens within the concepts that align with visual features, enhancing the interaction between textual and visual information. In addition, we introduce a Concept Modulated Decoder (CM-Decoder), which uses concepts from CVAM as modulation signals to facilitate the adaptive fusion of image and text features, improving the segmentation accuracy. Extensive experiments on two public datasets show that CGSM achieves state-of-the-art performance, with results of 91.59% Dice and 84.49% mIoU on the QaTa-COV19 dataset, demonstrating its effectiveness in pulmonary lesion segmentation.

0.09

NV-Reason-CT: 3D Visual Language Model for CT Analysis

cs.CV cs.AI ·2026-09-23 ·Andriy Myronenko, Dong Yang, Yucheng Tang, Baris Turkbey, Benjamin Simon +13 more
highly cited similarity 0.69
Abstract

We present NV-Reason-CT, a generative vision--language model for chest and abdominal CT combining native 3D visual encoding with radiologist-guided reasoning. The model couples a native 3D vision transformer with a language model, passing all visual tokens and their explicit 3D coordinates into language decoding without further spatial token merging. This retains volumetric spatial information within the vision encoder and through the language model's positional encoding during joint processing with text. We train on a curated corpus of approximately 550,000 multimodal instruction examples from 70,111 unique CT image inputs, combining standardized reports, abnormality-focused and anatomy-specific questions, multi-turn interactions, and radiologist-authored reasoning from recorded and transcribed expert CT interpretations. Expert annotations provide direct supervision and guide additional report-grounded synthetic reasoning. End-to-end supervised fine-tuning (SFT) is followed by Group Relative Policy Optimization (GRPO), with verifiable rewards over chest and abdominal abnormality sets. The model supports abnormality classification, report generation, and interactive reasoning with reviewable observations, differential diagnoses, and uncertainty. Evaluation spans public CT benchmarks and a held-out NIH cohort. On CT-RATE, NV-Reason-CT achieves a macro-F1 of 0.614 and macro-AUROC of 0.871 without a task-specific classification head; generated reports achieve a report-derived macro-F1 of 0.592. In a preliminary study with expert radiologists, AI-assisted review received favorable confidence ratings and was associated with a 50% reduction in average reported interpretation and reporting time. We release the model and training code to support reproducible research on explainable AI for volumetric medical imaging.

0.41

Uni-Loc: Weakly Supervised 3D CT Pathology Localization via Spatially Grounded Vision-Language Classification

cs.CV ·2026-11-09 ·Hao-Chih Lee, Zahi A. Fayad, Xueyan Mei
similarity 0.69
Abstract

Accurate localization of abnormalities in three-dimensional (3D) CT scans is essential for linking automated predictions with clinically relevant pathological findings. We propose Uni-Loc, a vision-language framework that unifies pathology classification and 3D localization using scan-level supervision. Uni-Loc derives both predictions and localization maps from spatial similarities between pathology-conditioned queries and image features. A token-to-voxel upsampling module enables high-resolution localization, while gradient-guided thresholding identifies pathology regions without additional learned parameters. Evaluated on five localization tasks comprising 355 annotated CT scans, Uni-Loc achieves macro-averaged voxel-level AUROC/AUPR of 96.1\%/34.5\%, outperforming relevance propagation (80.7%/13.9%) and gradient saliency (88.7%/8.1%). Uni-Loc also achieves classification AUROC of 88.39% on CT-RATE and 78.03% on RAD-ChestCT, improving over a matched baseline. These results demonstrate effective 3D pathology localization without requiring pathology-specific voxel-level supervision.

0.12