CS Paper Radar

Performance, Scalability and Maintenance: An Experimental Study of RPA vs. Autonomous Agents in the Healthcare Domain

Daniel Schulz, Pedro Cabral Buchaim, Bernardo Soares, Fernando Rafael Ensslin Schwengber, Lorenzo Farias, Daniela Duarte da Silva Bagatini, Ana Paula Wernz da Cunha Müller

cs.AI cs.SE ·submitted 2026-11-02 19:22 UTC · v1

Abstract

Healthcare information systems are fragmented, and retrieving data from legacy web portals is a recurrent need. Robotic Process Automation (RPA) is deterministic but sensitive to interface changes, whereas autonomous agents based on large language models (Agent Process Automation, APA) promise adaptability at a higher computational cost. Following Design Science Research, we developed and compared an RPA solution (Playwright) and an APA solution (browser-use, LangGraph and Gemini 2.5 Flash-lite) to retrieve mammography and breast ultrasound reports from a laboratory portal, treating reports solely as informational artifacts. Across two rounds (T and T+7), RPA reached 98.90% accuracy and 98.27% F1-score versus 96.49% and 94.48% for APA, was about 13 times faster (16.07 s vs. 207.21 s per patient) and cost about six times less per report (USD 0.030 vs. 0.187). Both reached 100% step success rates; APA varied more over time. For a stable interface, RPA was superior.

Comment
19 pages, 3 figures, 6 tables

Closest papers

Nearest neighbours by meaning across the whole index.

MedPAO-Assist: Edge-Deployable, Modality-Aware Agentic AI for Radiology Report Structuring

cs.AI ·2026-10-17 ·Shrish Shrinath Vaidya, Minmini Selvam, Ganapathy Krishnamurthi
published similarity 0.61
Abstract · The paper has been accepted at MICCAI Workshop Agentic AI for Medicine, 2026

The adoption of Large Language Models for radiology report structuring has been largely dominated by either proprietary cloud-based models or large open models requiring high-end GPUs for deployment, which is a critical bottleneck for clinical adoption in radiology workflows that demand data privacy and offline operation. To address this, we present MedPAO-Assist, an edge-deployable agentic framework that generates structured radiology reports directly from radiologist dictation and voice commands, requiring only $\approx3.3$ GB peak RAM and achieving an average end-to-end latency of $\approx31$ seconds on a standard laptop CPU through an asynchronous, multi-threaded execution pipeline. The system currently supports four major imaging modalities -- Chest X-ray, Chest CT, Abdomen CT, and Brain MRI. To our knowledge, it is among the earliest agentic systems to run its entire pipeline with a Small Language Model (SLM) in the 0.6B-parameter range. This multi-agent architecture, built around an Extract-Ground-Generate paradigm, performs concept extraction, SNOMED-CT grounding, and structured report generation, followed by a speech-driven human-in-the-loop correction phase, together forming a fully "no-touch" reporting workflow that requires no keyboard input, external API calls, or internet connectivity. We evaluate each pipeline stage individually -- concept extraction, ontology grounding, and concept categorization and report hardware profiling results demonstrating the system's feasibility for real-time, CPU-only clinical deployment.

0.24

Can Agentic Systems Close the Gap in Radiology with Production AI Tools?

cs.AI cs.LG ·2026-11-06 ·Aubin Charley, Julien Khlaut, Charles Corbière, Pierre Manceron, Corentin Dancette +1 more
similarity 0.60
Abstract

Radiology AI has developed along two paths: specialized models that perform well on narrow tasks but cover few clinical findings, and generalist models that address a broader range of tasks but remain prone to hallucination and inaccurate measurements. Combining the two through agentic systems offers a route towards comprehensive radiology reporting, but published systems are tied to one modality or body part. We describe a radiology agentic framework that standardizes how an orchestrator calls modular tools to produce a structured report, and use it to measure what such a system can do with the tools from FDA-cleared radiology AI devices. Report generation is simulated on a large multi-modality report corpus, with the orchestrator given either a catalog of finding classes consolidated from the cleared devices, each available on the modalities it is cleared for, or an unlimited catalog in which any class can be requested, and planning either from the clinical indication or from the target report. Tool outputs are simulated from the reference report, so the comparison isolates tool availability and orchestration from tool error. With the cleared catalog and the indication alone, the orchestrator recovers under a third of the clinically actionable findings; recovery improves substantially with the unlimited catalog, and further when the plan is written from the target report. Attributing every missed finding to a cause shows that most are classes no cleared device offers for the study's modality, and that a third are classes or tools that were offered and not called. Adding the most frequently missing tools closes most of the gap to the unlimited catalog on held-out reports, whereas a smaller orchestrator with the unlimited catalog gives up the whole gain. Tool availability and effective orchestration are thus complementary constraints on comprehensive AI-assisted radiology reporting.

0.11

Research with AI Agents: How Agentic Systems Are Changing Scientific Work

cs.CY ·2026-09-25 ·Johannes Lotz, Markus Wenzel
similarity 0.60
Abstract · 6 pages, 1 figure. English translation followed by the original German version. Submitted to Die Pathologie (Springer Medizin)

Background. Agentic AI systems independently decompose tasks such as literature search, data analysis, and programming into subtasks, search the web, access databases, and execute code. This allows them to perform digital research tasks at high speed. Objectives. Under what conditions does the use of agentic systems produce reliable efficiency gains, and which tasks remain with researchers? Materials and methods. Summary of current studies on literature searches, data analysis, software development, and clinical decision support. Results. For digital activities, work shifts from execution to steering and review. Efficiency gains are greatest when expected behavior can be formalized in advance and tested automatically. In complex agentic systems, recorded sequences of reasoning steps and tool calls can quickly become too extensive for human review. Furthermore, explanations generated by the model do not reliably reflect how an output was produced. One possible step toward more reliable systems is the validation of individual components. The limited reviewability extends beyond research itself; the review of scientific articles and grant proposals is also reaching capacity limits. In pathology, curated and annotated data, researchers' own analytical skills, and institutional exchange of experience are becoming increasingly important. Conclusions. Researchers remain responsible for their results. They must determine what to delegate and how to review the results. The importance of a research question to patients, the field, and society cannot be fully assessed using formalized criteria and remains a matter of expert judgment. Agentic systems can free up time for this.

0.09

A Data-Driven Framework for Identifying and Prioritizing RPA Opportunities in Healthcare Processes

cs.AI cs.CL ·2026-09-08 ·Maria Alejandra Gomez, Juan Manuel Castillo
code/data similarity 0.58
Abstract · 21 pages, 2 figures, 14 tables

Robotic Process Automation (RPA) is widely used to reduce administrative burden in United States hospitals, yet an estimated 30-50% of RPA initiatives underperform because processes are selected informally, without a repeatable method to catalogue candidates, prioritize them, match each to an automation tier -- a Python bot, an open-source orchestrator such as n8n, or an enterprise platform such as UiPath -- and forecast financial return before committing resources. We propose a four-module, data-driven framework unifying these decisions: a Process Taxonomy of twenty recurring hospital processes across five value streams; a Prioritization module deriving an Automation Suitability Index from an Analytic Hierarchy Process matrix with an explicit consistency check; a Tool-Tier Selection module recommending the least-cost technology sufficient for a process complexity, integration, and compliance profile; and a Return-on-Investment module quantifying labor savings, error-cost avoidance, payback, and net present value. Applied to a synthetic portfolio spanning all twenty processes, plus a reference data-flow architecture linking it to hospital EHR/payer/ERP systems: 12 of 20 clear the prioritization threshold; the ranking is robust to +/-20% weight perturbation (Spearman correlation 0.83, top-5 set preserved 97.7%, 2,000 Monte Carlo trials); an Automation Risk Index flags four qualifying processes as Critical risk; a budget-constrained portfolio optimization shows diminishing marginal NPV as spend scales from $400K to $1.03M; and a second Monte Carlo analysis shows portfolio NPV stays positive at its 5th percentile. The framework is a conceptual synthesis of the literature rather than an instrument calibrated on primary hospital data; we discuss HIPAA governance and a research agenda for empirical validation. A supplementary Python implementation accompanies the paper.

0.39

STEP: A Modular Silent Trial Engine for Operational Evaluation of Digital Pathology AI in Routine Workflow

cs.SE cs.CV ·2026-08-27 ·Gabriele Campanella, Matthew Croken, Olga Lukatskaya, Jane Houldsworth, Ricky Kwan +2 more
similarity 0.58
Abstract

Prospective silent trials provide an important bridge between retrospective validation of artificial intelligence (AI) models and their use in clinical care by evaluating model performance and operational reliability on live clinical data without influencing patient management. In computational pathology, conducting silent trials requires integration across laboratory information systems, digital pathology infrastructure, computational resources, and model inference pipelines, and these workflows are often implemented using application-specific software. We developed the Silent Trial Engine for Pathology (STEP), a reusable software platform for orchestrating prospective silent trials of computational pathology AI models across heterogeneous clinical and computational environments. STEP separates common trial orchestration from institution-specific data access and compute infrastructure through modular adapter interfaces. The platform supports scheduled case discovery, per-slide inference submission, deterministic idempotency, failure recovery, result and ancillary-data ingestion, persistent trial and run state, and audit logging, with compute adapters supporting local execution and high-performance computing environments using LSF and Slurm. STEP was deployed at three institutions to support prospective silent evaluation of EAGLE, an AI model for predicting EGFR mutation status from hematoxylin and eosin-stained whole-slide images. By separating trial-level workflow logic from site-specific integrations, STEP enables a common execution framework to operate across heterogeneous pathology environments while maintaining durable and auditable trial state. This approach may reduce duplicated engineering effort and facilitate systematic real-world evaluation of computational pathology AI before interventional clinical deployment.

0.24

The LLENS Platform for On-Premises Large Language Model Agents in a Japanese University Hospital: Development and Evaluation Study

cs.CL cs.AI ·2026-10-23 ·Ken Enda, Jien Saito, Masami Mukai, Feng Han, Emir Turkes +10 more
similarity 0.58
Abstract · 49 pages, 3 figures, 6 tables, with supplementary material

Large language model agents that use tools could take on part of the electronic health record and desk work that occupies physicians' time, but in many hospitals the medical information systems run inside closed networks, so the model and the agent harness must also be inside the network. We designed, implemented, and deployed LLENS, a clinical support AI agent platform that runs inside the closed network of Hokkaido University Hospital on a single host with 8 NVIDIA H200 GPUs, the open-weight model Kimi K2.6 (~1 trillion parameters), and a web application rebuilt from Open WebUI. The harness has 10 components, including page image reading, full-text attachment input, a path-addressed document tree without a vector index, a network-isolated sandbox, artifact return, self-checking of generated output, subagents, and saved procedures. Kimi K2.6 was chosen from 3 open-weight candidates and scored 480/500 on the 2026 Japanese Medical Licensing Examination; it generated 119 tokens/s for a single user and served 16 concurrent requests at 908 tokens/s in total. On 180 questions over hospital documents (3 seeds each), mean accuracy was 10.7% with no documents, 81.3% with fixed retrieval (top 10 chunks of one lexical search), and 97.2% with interactive access, in which the model reads with document tools and the sandbox (15.9 percentage points above fixed retrieval, 95% CI 10.9-21.3); the difference lay in filtering/counting questions (16.7% vs 87.8%). In an automated test of 13 work scenarios (4 runs each), the expected components were triggered in all runs for 12, and 5 scenarios were run with synthetic data on the deployment host. The platform has run on the hospital network since September 14, 2026.

0.29

PhysEvo: Astra Can Act, Let It

cs.RO cs.AI ·2026-10-06 ·Wenqing Tian, Zeyu Zhang, Zhaocheng Liu, Fengwei Liu, Qiang Liu +1 more
highly cited similarity 0.57
Abstract

Astra can act, yet reliable manipulation depends on the system through which it observes and controls the world. We introduce PhysEvo, a framework for physical recursive self-improvement (RSI) around a single frozen model. A task agent executes robot tasks; a meta-agent uses the resulting trajectories to diagnose failures, revise tools and skills, and test corrections. The meta-agent can also improve its own diagnostic tools, so retained revisions support both later action and later self-improvement. This process develops joint-level control, evidence-seeking observation, and reusable manipulation skills without model-weight updates or a separately trained action policy. Across 42 RoboDojo tasks, held-out-layout evaluation of retained task-specific deployment versions yields a five-dimension average score of 68.14/100 and 62.00% success, compared with 47.17% for RoboDawn's one-shot Astra agent, the strongest published reference in our comparison. On eight manipulation tasks challenging direct Astra, PhysEvo achieves 55.00% success, compared with 1.25% for the direct-Astra reference. Deploying the simulation-evolved harness on AgileX PiPER and continuing skill revision yields 90.60/100 average score and 84.00% success across 25 trials on five real-world tasks. PhysEvo turns the consequences of action into persistent, testable changes to how a frozen model acts and improves.

0.47

MedImageOSWorld: Benchmarking GUI Agents for Medical Image Consoles

cs.AI cs.CV ·2026-10-03 ·Ziyang Long, Xinqi Li, Lujing Xing, Hsin-Jung Yang
benchmark similarity 0.57
Abstract · 11 pages, 3 figures. Supplementary material (8 pages) included as an ancillary file

Graphical consoles offer a practical interface for medical acquisition assistance, allowing agents to work through the controls and visual feedback used by human operators. Reliable assistance requires linking on-screen anatomy to acquisition decisions that determine what image evidence becomes available next. We introduce MedImageOSWorld, a benchmark for evaluating this capability in simulated CT, MR, and ultrasound consoles. Using screenshots and mouse-and-keyboard actions, agents configure protocols, plan acquisitions, inspect the resulting images, and make corrective adjustments across seven capability levels, from console operation to feedback-driven control. Evaluation combines task-specific workflow checks with hidden anatomical ground truth to assess procedural completion and acquisition outcomes separately. A common evaluation protocol specifies episode conditions and interaction budgets, while recorded trajectories support analysis of how agents observe, act, and respond to acquisition feedback. Across eleven open-weight agents, success rates range from 3.0 to 25.0 on a 0-100 scale while workflow-progress rates reach 21.5-74.5: agents complete much of the console workflow but rarely acquire the intended anatomy. Success collapses between perception and planning, from 79-90% at the lowest three levels for the best agent to at most 12% for millimetre-level planning and 0% for closed-loop control among open-weight agents. Two proprietary agents reach success rates of about 34 and exceed the best open-weight agent mainly in acquisition quality (61 versus 42). MedImageOSWorld provides a controlled setting for studying whether general-purpose GUI agents can translate visual observations into effective medical acquisition decisions.

0.37