CS Paper Radar

PINR-ESI: Physics-Informed Self-Supervised Implicit Neural Representation Framework for EEG Extended-Source Imaging

Zhiyong Zhou, Sheng Liao, Xiaolin Li, Youshen Xiao, Bin Dai, Surui Liu, Yakang Dai

cs.LG q-bio.NC ·submitted 2026-11-04 16:02 UTC · v2

Abstract

EEG extended-source imaging aims to localize active cortical regions and characterize their spatial extent, yet supervised inverse networks typically depend on synthetic EEG-source pairs and may be sensitive to synthetic-to-real mismatch. We propose a physics-informed self-supervised implicit neural representation (INR) framework for spatial source reconstruction without paired source labels or simulation-based supervised pretraining. The lead field matrix encodes the source-to-sensor volume-conduction model and constrains the INR through agreement between predicted and measured EEG. Cortical current density is modeled as a continuous coordinate-conditioned field. A classical inverse estimate provides warm initialization and spatial constraints on source activity, while patch-integrated projection maps the field to discrete source coefficients for forward modeling. Simulations across varying noise levels, source extents, and source counts showed consistently low spatial dispersion and good localization performance. Quantitative and qualitative evaluations using real EEG recordings from epilepsy patients and intracranial stimulation experiments further supported the feasibility of the framework for source imaging. These findings suggest the potential of physics-informed self-supervised INR for extended-source imaging.

Comment
Preprint, 10 pages, 11 figures

Closest papers

Nearest neighbours by meaning across the whole index.

Observable And Null Space Electrophysiological Source Imaging with Diffusion Priors

cs.CE ·2026-10-20 ·Zirui Wen, Shihao Yang, Feng Liu
similarity 0.70
Abstract

Electrophysiological source imaging is severely underdetermined because the lead-field matrix has limited rank relative to the source dimension and strongly correlated columns. Scalp EEG measurements constrain only the observable row-space component, leaving a high-dimensional null space unobservable. We propose a two-stage framework coupling posterior diffusion refinement with deterministic null-space completion. A minimum-norm-initialized, singular-coordinate Posterior-DDIM sampler combines a spatiotemporal diffusion prior with direction-dependent measurement reliability to refine the observable component. A frozen ridge predictor and nonlinear temporal residual network then estimate the null component under explicit projection constraints, preserving the refined row estimate and its predicted EEG exactly. All learned components are trained exclusively on simulated cortical activity and its row-null decomposition, without paired EEG-source training data. Across simulations with varying noise levels, the method achieved higher frame-level area under the receiver operating characteristic curve and average precision, together with lower localization error, than conventional and learning-based baselines. Exploratory evaluations on evoked EEG and simultaneous scalp EEG-stereo-EEG recordings showed condition- and event-dependent concordance with cross-modal and intracranial references.

0.11

NeuroDyn-EEG: An Interpretable Pre-trained Model for EEG Based on Neural Dynamics

cs.NE ·2026-09-29 ·Yi Cui, Tong Zhao, Jiaxin Lei, Chuyi Yang, Yifan Cui +3 more
code/data similarity 0.66
Abstract · Yi Cui and Tong Zhao contributed equally. Corresponding authors: Ling Zhang, Yuxiang Yan, and Bo Hong

Clinical scalp electroencephalography (EEG) offers a noninvasive window into neural dynamics of neuropsychiatric disorders. However, discriminative deep models often lack anatomically indexed physiological interpretability. We propose NeuroDyn-EEG, a pretraining framework integrating generative priors from neural dynamics. It couples an extended Jansen-Rit neural mass model, leadfield-based source projection, and simulation-based parameter inversion. Trained on synthetic parameter-EEG pairs within physiological ranges, NeuroDyn-EEG estimates 11 regional parameter families across 90 AAL regions plus one global parameter from standard 19-channel EEG, using only ~2.43M trainable parameters. We evaluate the framework across three levels. First, controlled simulations demonstrate robust parameter recovery under diverse noise conditions, while real resting-state EEG evaluations confirm spectral and phase consistency in an inverse-forward closed loop. Second, on four clinical benchmarks (AD65, PD31, Figshare MDD, and TUAB), NeuroDyn-EEG achieves competitive classification performance, securing the highest BACC, AUROC, and AUCPR on PD31 and MDD, and highest BACC on AD65. Third, post hoc regional analyses reveal disease-specific alterations: local synaptic connectivity C_1 involves the most altered regions in AD65, whereas the firing threshold theta ranks first in MDD, offering testable mechanistic hypotheses. Overall, NeuroDyn-EEG maps scalp EEG to anatomically indexed dynamical parameters, bridging representation learning and mechanistic neurophysiology. Code: https://github.com/Gnosis-Neurodynamics/NeuroDyn-EEG.

0.21

Decoupling Time and Space: A Temporally Conditioned Refinement for EEG Source Imaging

cs.LG ·2026-10-05 ·Marco Morik, Jesse Palarus, Carmen Vidaurre, Klaus-Robert Müller, Shinichi Nakajima
similarity 0.65
Abstract · This work has been submitted to the IEEE for possible publication. Copyright may be transferred without notice, after which this version may…

Electroencephalography (EEG) offers millisecond temporal resolution, but inferring underlying neural sources is a severely ill-posed spatial inverse problem. While deep learning has advanced spatial reconstruction, current architectures face a critical dilemma: frame-by-frame models discard vital temporal context, whereas full 4D spatiotemporal networks introduce an architectural trade-off between reconstruction accuracy and inference cost. We propose a novel two-stream framework that explicitly decouples global temporal representation learning from per-time-point spatial refinement. A Transformer-based Temporal Condition Encoder processes the entire EEG sequence via factorized spatiotemporal attention, retaining sensor-resolved features. A fixed inverse then maps these features into source-indexed conditioning for a per-timestep Source-Space Transformer or volumetric convolutional refiner. Extensive evaluations on realistic synthetic data demonstrate that this temporal prior dramatically improves spatial localization, outperforming classical and spatiotemporal baselines, particularly in high-noise and multi-source regimes. Training across diverse leadfields and explicit operator mismatches improves transfer to unseen head geometries and brings template-based reconstruction closer to subject-specific inversion. Furthermore, we apply the model trained only on synthetic EEG data to real-world EEG. A logistic regressor fit on source power differences in eyes-open, eyes-closed conditions successfully decodes age groups.

0.25

EEG-PRISM: Physiologically-Grounded Interpretability of Predictions by EEG Foundation Models

cs.LG ·2026-08-13 ·Deeksha M Shama, Punnisa Amornsirikul, Archana Venkataraman
similarity 0.65
Abstract

Objective: Foundation models represent the next advancement in AI for EEG analysis; however current explainable AI techniques provide attribution scores in the time-channel input space, which is mismatched to clinical intuition about EEG. Thus, there is a critical need for a universal method that can extend the interpretability of any foundation model to alternative and physiologically relevant domains without modifying or retraining the underlying model. Methods: EEG-PRISM leverages linear transformations and established backpropagation rules to map time-channel attribution scores into alternative domains. We derive mappings to the frequency domain via an invertible DFT and to the source domain via an approximately invertible EEG generative model. We evaluate EEG-PRISM in simulated and real data, assessing recovery of ground-truth phenomena across domains with five foundation models and four AI explainers. Results: In simulation, EEG-PRISM achieves near-perfect spectral recovery and 69.2% spatial accuracy. In epilepsy, EEG-PRISM correctly determines that delta-theta activity is most salient and correctly localizes the seizure onset region with 50% accuracy. In autism, EEG-PRISM localizes the predictive delta-alpha biomarkers to frontal and temporal regions, consistent with prior work. Conclusion: EEG-PRISM is a theoretically-grounded post-hoc attribution method with accurate mapping into the spectral and spatial domains. It supports window-level analysis of transient events (e.g., seizures) and group-level identification of clinically relevant biomarkers (e.g., autism), thus advancing interpretable EEG foundation models. Significance: This work enables physiologically-grounded interpretation of EEG foundation models and supports clinically relevant insights such as event localization and biomarker identification.

0.04

Identifying Neural Source Dynamics from Unknown Local Interventions

cs.LG ·2026-09-28 ·Ayana Mussabayeva, Jiaqi Sun, Anuar Aimoldin, Olivier Oullier, Kun Zhang
similarity 0.65
Abstract · 11 pages main text, 52 pages total including references and appendices; 3 figures

Electroencephalography (EEG) records mixtures of brain-source activity. Even with a known anatomical forward model, experiments that excite only part of the source-state space leave the dynamics unidentified, and repetition cannot resolve the ambiguity. We show that unknown local mechanism changes can supply the missing information. We consider linear dynamics among fixed anatomical sources with known source-state initialization patterns. Changing one source's update rule for one transition leaves a rank-one, source-specific signature in subsequent EEG: subtracting matched baseline responses isolates it, and the forward model identifies the source and calibrates its response history. Combining these histories with initialization responses recovers source interactions without baseline reachability and without first identifying the intervention coefficients. We establish sufficient recovery conditions, a direct estimator, and a noise-sensitivity bound conditional on correct source labels. Simulated EEG on anatomy derived from magnetic resonance imaging confirms the information gain: with baseline excitation confined to four of twelve source coordinates, eight unknown changes recover all dynamics in 32/32 systems, whereas baseline realization, baseline regression through an invertible forward model, and changes that leave the tested states unexposed all fail, and explicitly constructed alternative dynamics reproduce every baseline mean. Where baseline information suffices, direct reconstruction is also more reliable than a matched-information spectral estimator. Nonlocal changes and forward-model error limit accuracy even when source labels are correct.

0.34

CANDLE: Cortical Null-Space Decomposition for Noninvasive Brain Source Imaging

cs.LG eess.SPq-bio.NC ·2026-10-06 ·Shuntaro Suzuki, Yuiga Wada, Komei Sugiura
code/data similarity 0.65
Abstract

Electrophysiological source imaging (ESI) aims to estimate cortical source activity from noninvasive electrophysiological measurements such as electroencephalogram (EEG). However, ESI is fundamentally ill-posed because source activity is substantially higher-dimensional than sensor observations, resulting in non-unique solutions. Recent learning-based approaches address this ambiguity by learning data-driven source priors, yet they often struggle to generalize across subject-specific cortical geometries. To address this, we propose CANDLE, a learning-based ESI model that estimates source activity on subject-specific cortical geometries. CANDLE learns a prior over the null space induced by the source-to-sensor mapping derived from T1-weighted MRI, restricting learning to unobservable source components while preserving geometric constraints. To train CANDLE, we develop a whole-brain simulator spanning over 1,100 subject-specific cortical geometries with source configurations derived from over 26,000 statistical brain maps. Trained exclusively on simulated data, CANDLE outperformed prior ESI methods on simulated source activity estimation and generalized to two empirical tasks: (i) intracranial stimulation localization from simultaneously recorded scalp EEG and (ii) epileptogenic zone estimation from presurgical interictal EEG. Our project page is available at https://candle-esi.pages.dev}{https://candle-esi.pages.dev.

0.42

Uncertainty calibration in Bayesian M/EEG source imaging

cs.LG cs.CE ·2026-11-04 ·Ismail Huseynov, Mohammad Orabe, Srikantan Nagarajan, Stefan Haufe
similarity 0.63
Abstract

M/EEG source imaging requires accurate localization and reliable uncertainty estimates, yet posterior credible regions are rarely assessed for empirical calibration. We present a simulation-based framework for uncertainty quantification and calibration of empirical Bayesian inverse methods with closed-form conditional Gaussian posterior summaries. We compare Bayesian minimum norm (BMN) with sLORETA depth weighting and sparse Bayesian learning (SBL) with sparse basis field expansions (S-FLEX). S-FLEX allows retained coefficients to contribute nonzero marginal posterior variance at locations where voxel-wise SBL yields degenerate variances. For BMN, we derive joint source- and noise-variance updates through evidence maximization. We test whether adaptive noise learning yields near-calibrated uncertainties. Both methods retain residual miscalibration, motivating post-hoc isotonic recalibration of credible-region levels using empirical coverage. Simulations assess fixed- and free-orientation models across signal-to-noise ratios (SNR), source sparsity levels, and subject-specific head models, using oracle, baseline-estimated, and adaptively learned noise. Before recalibration, SBL+S-FLEX yields lower Wasserstein localization error, smaller posterior uncertainty, and coverage closer to nominal credibility than BMN+sLORETA. Isotonic recalibration improves both methods, with larger gains for conservative BMN+sLORETA posteriors; transfer across mismatched SNR, sparsity, and head models remains condition dependent. Noise specifications yield broadly consistent reconstruction and uncertainty trends within each estimator. In real auditory MEG data, SBL+S-FLEX provides more focal localization and tighter uncertainties than BMN+sLORETA, suggesting greater statistical power for identifying bilateral auditory sources.

0.32

Taming foundation model with invariance-oriented pre-training for broad-spectrum EEG analysis across signal-level, brain-state, and brain-health tasks

cs.LG cs.AI ·2026-08-25 ·Yulong Dou, Han Wu, Guo Chen, Fangmao Ju, Zhiming Cui +1 more
benchmark similarity 0.61
Abstract

Electroencephalography (EEG) is a widely used window into human brain function, but most EEG models remain tied to a one-dataset-one-model supervised paradigm. Recent EEG foundation models offer a route toward reusable representations, but most remain reconstruction-centered, assuming that EEG content predictable from local context is necessarily transferable neural information. Here we present INCEPT, an invariance-oriented EEG foundation model trained on over 11,000 hours of unlabelled clinical EEG. Rather than prioritizing signal recovery alone, INCEPT learns representation-level stability across correlated EEG observations, separating stable neural structure and essential subject-sensitive information from the nuisance variability that dominates scalp recordings while preserving subject-, state- and condition-discriminative information. We evaluate INCEPT on a broad-spectrum benchmark of ten datasets spanning three levels of post-acquisition EEG analysis: signal-level assessment, brain-state decoding, and brain-health evaluation. INCEPT ranks first among recent EEG foundation models on 26 of 30 linear-probing metrics and 24 of 30 fine-tuning metrics, and also surpasses strong task-specific specialist encoders across diverse downstream settings. Objective ablations and representation analyses further show that invariance-oriented pre-training improves transfer and organizes subject-sensitive neural representations beyond reconstruction alone. These results establish invariance learning as a promising principle for building reusable EEG foundation models.

0.11