CS Paper Radar

Uncertainty calibration in Bayesian M/EEG source imaging

Ismail Huseynov, Mohammad Orabe, Srikantan Nagarajan, Stefan Haufe

cs.LG cs.CE ·submitted 2026-11-04 13:41 UTC · v1

Abstract

M/EEG source imaging requires accurate localization and reliable uncertainty estimates, yet posterior credible regions are rarely assessed for empirical calibration. We present a simulation-based framework for uncertainty quantification and calibration of empirical Bayesian inverse methods with closed-form conditional Gaussian posterior summaries. We compare Bayesian minimum norm (BMN) with sLORETA depth weighting and sparse Bayesian learning (SBL) with sparse basis field expansions (S-FLEX). S-FLEX allows retained coefficients to contribute nonzero marginal posterior variance at locations where voxel-wise SBL yields degenerate variances. For BMN, we derive joint source- and noise-variance updates through evidence maximization. We test whether adaptive noise learning yields near-calibrated uncertainties. Both methods retain residual miscalibration, motivating post-hoc isotonic recalibration of credible-region levels using empirical coverage. Simulations assess fixed- and free-orientation models across signal-to-noise ratios (SNR), source sparsity levels, and subject-specific head models, using oracle, baseline-estimated, and adaptively learned noise. Before recalibration, SBL+S-FLEX yields lower Wasserstein localization error, smaller posterior uncertainty, and coverage closer to nominal credibility than BMN+sLORETA. Isotonic recalibration improves both methods, with larger gains for conservative BMN+sLORETA posteriors; transfer across mismatched SNR, sparsity, and head models remains condition dependent. Noise specifications yield broadly consistent reconstruction and uncertainty trends within each estimator. In real auditory MEG data, SBL+S-FLEX provides more focal localization and tighter uncertainties than BMN+sLORETA, suggesting greater statistical power for identifying bilateral auditory sources.

Closest papers

Nearest neighbours by meaning across the whole index.

Exact Spectral Uncertainty Decomposition for Linear-Gaussian Bayesian M/EEG Inverse Problems

cs.LG cs.CE ·2026-10-21 ·Ismail Huseynov, Stefan Haufe
similarity 0.75
Abstract

Distributed magneto- and electroencephalographic (M/EEG) source reconstruction is a severely underdetermined linear inverse problem. Bayesian source imaging regularizes inversion through source-prior and sensor-noise covariances, but the posterior covariance does not directly distinguish uncertainty constrained by the measurements from uncertainty unobservable under the sensing geometry. We study this distinction for linear-Gaussian M/EEG models with diagonal source-prior and sensor-noise covariances, covering Type-I inference and Type-II inference conditional on learned covariance hyperparameters. After restricting the analysis to the prior-supported source space, standardizing the prior, and whitening the sensor noise, the complete singular spectrum of the forward operator separates likelihood-visible and likelihood-null directions. This yields an additive uncertainty decomposition of the conditional posterior covariance: uncertainty in likelihood-visible directions is reduced according to spectral information content, whereas likelihood-null uncertainty remains unchanged from the prior. The spectral representation also yields a prior-minus-reduction identity, showing that covariance reduction is confined to the likelihood-visible subspace. Spectral markers quantify likelihood information and prior-variance retention and reduction. Fixed-orientation MEG simulations with adaptive noise learning illustrate the framework. Dense Bayesian minimum-norm inference retains a large likelihood-null component, whereas sparse $γ$-MAP strongly reduces the fitted prior support. Within that support, the markers distinguish strongly informed directions from a weakly constrained direction. Thus, prior-support selection determines which source coordinates remain in the fitted model, while the spectral decomposition quantifies how strongly the retained directions are constrained by the measurements.

0.32

Observable And Null Space Electrophysiological Source Imaging with Diffusion Priors

cs.CE ·2026-10-20 ·Zirui Wen, Shihao Yang, Feng Liu
similarity 0.69
Abstract

Electrophysiological source imaging is severely underdetermined because the lead-field matrix has limited rank relative to the source dimension and strongly correlated columns. Scalp EEG measurements constrain only the observable row-space component, leaving a high-dimensional null space unobservable. We propose a two-stage framework coupling posterior diffusion refinement with deterministic null-space completion. A minimum-norm-initialized, singular-coordinate Posterior-DDIM sampler combines a spatiotemporal diffusion prior with direction-dependent measurement reliability to refine the observable component. A frozen ridge predictor and nonlinear temporal residual network then estimate the null component under explicit projection constraints, preserving the refined row estimate and its predicted EEG exactly. All learned components are trained exclusively on simulated cortical activity and its row-null decomposition, without paired EEG-source training data. Across simulations with varying noise levels, the method achieved higher frame-level area under the receiver operating characteristic curve and average precision, together with lower localization error, than conventional and learning-based baselines. Exploratory evaluations on evoked EEG and simultaneous scalp EEG-stereo-EEG recordings showed condition- and event-dependent concordance with cross-modal and intracranial references.

0.11

Diffusion Posterior Sampling with Uncertain Forward Models

cs.CV ·2026-10-21 ·Wentao Shangguan, Vivek K Goyal
similarity 0.63
Abstract

Diffusion posterior samplers reconstruct signals by combining a pretrained diffusion prior with a measurement likelihood specified by a forward model and a noise model. Calibration and reference data can characterize uncertainty in the forward model's parameters, such as blur kernels or detector responses. Fixing these parameters at estimated values leaves their uncertainty out of the likelihood, and parameter errors are thus absorbed into the reconstruction. We introduce an uncertainty-aware likelihood (UAL), a Gaussian approximation to the marginal likelihood obtained by integrating over the uncertain parameters. For each candidate signal, UAL propagates parameter uncertainty into a structured measurement covariance, reducing the quadratic penalty along residual directions that parameter variation can explain. Existing samplers can use UAL in their data updates while retaining their pretrained diffusion priors and sampling schedules. Under a fixed Gaussian nuisance model, we bound likelihood error from linearization and average divergence between the exact marginal and UAL posteriors. We compare samplers with and without UAL across six inverse problems spanning Gaussian and motion deblurring, CT, MRI, ultrasound, and fluorescence microscopy, and find improvements in reconstruction and ensemble prediction. UAL reduces geometric mean MSE by 9% to 20% across samplers in the main Gaussian-deblurring setting and by 51% to 92% in motion deblurring when non-blind samplers use the population-mean kernel. In motion deblurring, DAPS and PnP-DM with UAL also give 6.2 to 6.4 dB higher ensemble-mean PSNR than published BlindDPS and Fast Diffusion EM. On the ablation set, UAL outperforms trace-matched isotropic inflation for PnP-DM in both deblurring tasks; in motion deblurring, it also exceeds the best-tested fixed scalar data weighting by 3.3 dB for PnP-DM and 4.2 dB for DAPS in average PSNR.

0.10

CANDLE: Cortical Null-Space Decomposition for Noninvasive Brain Source Imaging

cs.LG eess.SPq-bio.NC ·2026-10-06 ·Shuntaro Suzuki, Yuiga Wada, Komei Sugiura
code/data similarity 0.63
Abstract

Electrophysiological source imaging (ESI) aims to estimate cortical source activity from noninvasive electrophysiological measurements such as electroencephalogram (EEG). However, ESI is fundamentally ill-posed because source activity is substantially higher-dimensional than sensor observations, resulting in non-unique solutions. Recent learning-based approaches address this ambiguity by learning data-driven source priors, yet they often struggle to generalize across subject-specific cortical geometries. To address this, we propose CANDLE, a learning-based ESI model that estimates source activity on subject-specific cortical geometries. CANDLE learns a prior over the null space induced by the source-to-sensor mapping derived from T1-weighted MRI, restricting learning to unobservable source components while preserving geometric constraints. To train CANDLE, we develop a whole-brain simulator spanning over 1,100 subject-specific cortical geometries with source configurations derived from over 26,000 statistical brain maps. Trained exclusively on simulated data, CANDLE outperformed prior ESI methods on simulated source activity estimation and generalized to two empirical tasks: (i) intracranial stimulation localization from simultaneously recorded scalp EEG and (ii) epileptogenic zone estimation from presurgical interictal EEG. Our project page is available at https://candle-esi.pages.dev}{https://candle-esi.pages.dev.

0.42

PINR-ESI: Physics-Informed Self-Supervised Implicit Neural Representation Framework for EEG Extended-Source Imaging

cs.LG q-bio.NC ·2026-11-04 ·Zhiyong Zhou, Sheng Liao, Xiaolin Li, Youshen Xiao, Bin Dai +2 more
similarity 0.63
Abstract · Preprint, 10 pages, 11 figures

EEG extended-source imaging aims to localize active cortical regions and characterize their spatial extent, yet supervised inverse networks typically depend on synthetic EEG-source pairs and may be sensitive to synthetic-to-real mismatch. We propose a physics-informed self-supervised implicit neural representation (INR) framework for spatial source reconstruction without paired source labels or simulation-based supervised pretraining. The lead field matrix encodes the source-to-sensor volume-conduction model and constrains the INR through agreement between predicted and measured EEG. Cortical current density is modeled as a continuous coordinate-conditioned field. A classical inverse estimate provides warm initialization and spatial constraints on source activity, while patch-integrated projection maps the field to discrete source coefficients for forward modeling. Simulations across varying noise levels, source extents, and source counts showed consistently low spatial dispersion and good localization performance. Quantitative and qualitative evaluations using real EEG recordings from epilepsy patients and intracranial stimulation experiments further supported the feasibility of the framework for source imaging. These findings suggest the potential of physics-informed self-supervised INR for extended-source imaging.

0.17

Bayesian Uncertainty Quantification for fMRI Functional Connectivity via Simulation-Based Inference

cs.LG stat.ML ·2026-09-24 ·Simon Carter, Zeming Kuang, Lilianne R. Mujica-Parodi, Helmut H. Strey
similarity 0.63
Abstract · 29 pages, 4 figures

Optimizing fMRI scan duration and spatial resolution is critical for experimental design, yet traditional correlation-based approaches cannot quantify uncertainty or disentangle scanner measurement noise from true neural variability across subjects. Without principled uncertainty bounds, researchers cannot know whether a protocol is long enough to reliably estimate connectivity, or whether between-subject differences reflect biological variation or noise. We present a Bayesian framework modeling BOLD dynamics as coupled Ornstein-Uhlenbeck processes, using Sequential Neural Posterior Estimation to obtain connectivity posteriors while accounting for frequency-independent measurement noise across the BOLD spectrum. Applied to N = 28 healthy controls (55 scans) at 7T using a functional network atlas (65 DMN regions), the framework quantifies uncertainty across its sources: scanner noise, subject variability, and acquisition length. Spatial analysis identifies a mean of 46 voxels per ROI, roughly half of typical region sizes, as sufficient to achieve 90% of asymptotic precision. At the single-subject level, 7T reaches its within-session precision plateau in approximately 7 minutes versus 10 minutes for 3T, a 40% reduction in required scan time, providing the first direct, model-based quantification of the scan-time advantage conferred by higher field strength. At the population level, 3T requires roughly 37 times more per-subject scan time than 7T for the pooled curves to converge, confirming a consistent advantage of higher field strength at every timescale. Together these findings provide concrete, scanner-specific guidance for protocol optimization, with direct implications for reducing acquisition costs and improving the reliability of connectivity-based clinical biomarkers. We provide code enabling researchers to derive these bounds from their own data.

0.28

Consecutive Posterior Fusion for Diffusive Recovery of Unobservable Image Structures

cs.CV cs.AI ·2026-10-02 ·Elena Morotti, Davide Evangelista, Elena Loli Piccolomini
similarity 0.61
Abstract · 21 pages, 7 figures, 2 tables

Solving severely ill-posed imaging inverse problems requires recovering image structures that are unobservable or weakly constrained by the measurements. Diffusion models provide expressive learned priors for inferring such missing information, while posterior sampling incorporates measurement consistency along the reverse process. Standard diffusion posterior samplers, however, rely on instantaneous measurement-aware estimates, without explicitly exploiting information carried by previous posterior corrections. We introduce Consecutive Posterior Fusion Denoising Diffusion Null-Space Models (CPF-DDNM), an inference-time strategy that fuses consecutive measurement-aware estimates to improve the diffusive recovery of unobservable image structures, without requiring retraining or additional denoiser evaluations. We instantiate this principle within DDNM, whose range/null-space decomposition reveals that consecutive fusion preserves the measurement-determined component while acting exclusively on the prior-driven null-space estimate. We thus provide a geometric interpretation of CPF-DDNM and a local error analysis that characterizes the optimal time-dependent fusion coefficient, including the extrapolative regime. Experiments on sparse-view and simulated low-dose computed tomography, as well as medical image super-resolution, show consistent improvements over DDNM and competitive performance against diffusion-based inverse solvers.

0.14

Identifying Neural Source Dynamics from Unknown Local Interventions

cs.LG ·2026-09-28 ·Ayana Mussabayeva, Jiaqi Sun, Anuar Aimoldin, Olivier Oullier, Kun Zhang
similarity 0.61
Abstract · 11 pages main text, 52 pages total including references and appendices; 3 figures

Electroencephalography (EEG) records mixtures of brain-source activity. Even with a known anatomical forward model, experiments that excite only part of the source-state space leave the dynamics unidentified, and repetition cannot resolve the ambiguity. We show that unknown local mechanism changes can supply the missing information. We consider linear dynamics among fixed anatomical sources with known source-state initialization patterns. Changing one source's update rule for one transition leaves a rank-one, source-specific signature in subsequent EEG: subtracting matched baseline responses isolates it, and the forward model identifies the source and calibrates its response history. Combining these histories with initialization responses recovers source interactions without baseline reachability and without first identifying the intervention coefficients. We establish sufficient recovery conditions, a direct estimator, and a noise-sensitivity bound conditional on correct source labels. Simulated EEG on anatomy derived from magnetic resonance imaging confirms the information gain: with baseline excitation confined to four of twelve source coordinates, eight unknown changes recover all dynamics in 32/32 systems, whereas baseline realization, baseline regression through an invertible forward model, and changes that leave the tested states unexposed all fail, and explicitly constructed alternative dynamics reproduce every baseline mean. Where baseline information suffices, direct reconstruction is also more reliable than a matched-information spectral estimator. Nonlocal changes and forward-model error limit accuracy even when source labels are correct.

0.34