CS Paper Radar

HippoMamba: A Mamba-augmented network for hippocampal segmentation and serial volumetry in Alzheimers disease

Dawa Chyophel Lepcha, Sophie A. Martin, Pierrick Coupe, Shabbir Syed-Abdul

cs.CV cs.LG ·submitted 2026-10-26 13:01 UTC · v1

Abstract

Hippocampal atrophy is among the earliest structural markers of Alzheimer's disease, and reliable hippocampal segmentation across serial MRI visits is a prerequisite for measuring it. We present HippoMamba, a network that combines a 3D convolutional encoder and decoder with a Mamba selective state space block at the bottleneck, designed to process one or more MRI visits of a subject. On the Medical Segmentation Decathlon hippocampus dataset (260 subjects, five-fold cross-validation), HippoMamba obtained a mean Dice similarity coefficient of 0.8861 $\pm$ 0.0094, the highest among six convolutional and transformer-based methods trained with the same folds and patch size, and its per-subject Dice was significantly higher than that of each method (Holm-corrected Wilcoxon tests, $p \leq 0.013$). Its mean 95th percentile Hausdorff distance (1.45 mm) and average surface distance (0.44 mm) were the lowest of the compared methods, although they did not differ significantly from those of Attention U-Net, and the Hausdorff distance did not differ significantly from that of SegResNet. Without retraining, the five-fold ensemble was applied to 600 T1-weighted sessions from 150 participants of the OASIS-3 cohort. In sessions meeting a registration quality criterion, predicted hippocampal volumes ranked consistently with FreeSurfer volumes (Pearson r = 0.778, 95% CI 0.699 to 0.838; ICC(3,1) = 0.772) but were systematically smaller by about 27%. In a pre-specified analysis of participants followed for at least two years, annualised volume change derived from per-visit segmentation was moderately correlated with that of FreeSurfer (r = 0.503, 95% CI 0.319 to 0.659), with a larger mean rate. These results support the use of HippoMamba for hippocampal segmentation and for ranking hippocampal volume within a cohort, with absolute volumes and rates of change interpreted relative to the reference method.

Comment
22 pages, 7 figures, 5 tables

Closest papers

Nearest neighbours by meaning across the whole index.

Evidence Before Accuracy: A MRI-PET Fusion Network for Alzheimer Disease Classification with Causal Regional Validation

cs.CV ·2026-09-28 ·Saeid Firouzi Daghigh, Saeed Ayat
similarity 0.65
Abstract

Deep learning models for Alzheimer disease (AD) classification routinely report near-perfect discrimination, yet few are shown to rest on AD-relevant neurobiology rather than on dataset artifacts, subject-level leakage, or non-brain image content. We present a fusion network combining T1 MRI and FDG PET across axial, coronal, and sagittal planes, trained on ADNI consists of 554 paired subjects. The fusion model reaches AUC 0.962, accuracy 0.909, and F1 0.891, competitive with recent 3D CNN and multimodal transformer systems at substantially lower cost. We first quantify how much modality, plane and slice geometry matter. A validation-only search over slice centres and neighbour spacings moves AUC by 0.180 for MRI and 0.078 for PET, selecting narrow spacing for MRI and wide spacing for PET, with the chosen coronal centres falling on the hippocampal body and on the posterior cingulate respectively. The contribution, however, is the evidence layer built around that number. Shortcut controls collapse the model to AUC 0.622 (silhouette), 0.608 (exterior), and 0.500 (blank), and a label-permutation null yields 0.456. Forward region-of-interest (ROI) ablation shows that masking medial temporal cortex in MRI and the posterior default-mode network (DMN) in PET produces the largest shift in the AD logit, while area-matched controls remain indistinguishable from that null. Reverse ROI ablation shows that the medial temporal lobe alone retains 89.2% of above-chance discrimination in MRI and the posterior DMN alone retains 79.0% in PET. A quantitative comparison of attribution methods shows occlusion sensitivity reaching 3.5-5.0* enrichment inside a priori AD regions against 0.10-0.43* in controls. Ablation and attribution independently establish a biologically correct double dissociation: hippocampal evidence is carried by MRI, posterior cingulate evidence by PET.

0.12

AG-JEPA: Anatomically Guided Joint Embedding Predictive Architecture for Neurodegenerative Representation Learning

cs.CV cs.AI ·2026-11-13 ·Azad Singh, Ayantika Das, Amog Rao, Aiman Farooq, Anirban Porya +5 more
similarity 0.62
Abstract

Brain MRI can reveal early signs of Alzheimers disease (AD) before measurable cognitive decline becomes apparent. However, during the transition from cognitively normal (CN) to mild cognitive impairment (MCI), the disease-related signals are often subtle and confined to only a few brain regions. Existing Joint Embedding Predictive Architecture (JEPA) models learn general structural representations but do not explicitly capture the anatomical regions affected in AD. We propose Anatomically Guided JEPA (AG-JEPA), which introduces anatomical tokens that interact with patch tokens during pretraining to learn region-specific representations from brain regions relevant to neurodegeneration. Building on this representation space, we further propose Prog-AG-JEPA, which models disease progression trajectory as a conditioned latent displacement within this space. We evaluate AG-JEPA across five downstream tasks spanning Alzheimer's disease diagnosis and progression prediction. AG-JEPA improves diagnosis and MCI prognosis, achieving an 8.4 percentage point AUROC gain over the strongest baseline on CN/MCI classification and a 7.1 percentage point gain on out-of-distribution CN/AD classification on the MR-RATE dataset, highlighting its effectiveness across both early-stage detection and cross-cohort generalization. For disease progression modeling, Prog-AG-JEPA consistently outperforms all baselines on future diagnosis and brain volume change prediction, demonstrating the value of anatomically grounded neurodegeneration representations for diagnosis and prognosis.

0.09

Evaluation of Uncertainty-Aware Multi-Software Ensembles for Hippocampal Segmentation

cs.CV ·2026-10-22 ·Gabriel Oliveira-Stahl, Anna Schroder, James Moggridge, Hamza A. Salhab, Caroline Micallef +4 more
top venue similarity 0.61
Abstract · Accepted for publication at the Journal of Machine Learning for Biomedical Imaging (MELBA) https://melba-journal.org/2026:030

Accurate hippocampal segmentation can be a useful tool for diagnosing and monitoring neurological conditions such as Alzheimer's disease and epilepsy. While numerous automated segmentation methods exist, their clinical adoption remains limited. Reliable uncertainty assessment can enhance trust and facilitate clinical translation. This study evaluates ensembles of five heterogeneous hippocampal segmentation methods - InnerEye, ASHS, FastSurfer, HippoSeg, and FreeSurfer - across two dementia datasets and one epilepsy dataset. The sub-ensemble containing InnerEye, FastSurfer, and HippoSeg emerged as both accurate and efficient, highlighting the feasibility of balancing computational cost and performance. Additionally, ensemble-derived uncertainty quantification with sample variance, mutual information, and predictive entropy is shown to reduce inaccurate segmentations by flagging low-confidence cases, potentially providing a mechanism for automatically escalating ambiguous cases for expert assessment. Lastly, this study explores the downstream clinical utility of ensemble-derived uncertainty, finding a significant correlation with motion artefact severity and a modest contribution to Alzheimer's disease classification.

0.49

Anatomical Grounding and Leakage-Aware Multimodal Contrastive Learning for Alzheimer's Disease Classification from Structural MRI

cs.CV cs.AI ·2026-09-14 ·Paul-Gabriel Nicolae, Irina Georgiana Mocanu
theory similarity 0.61
Abstract · 13 pages, 4 figures

Deep networks trained on structural MRI for Alzheimer's disease (AD) staging often reach reasonable accuracy while attending to anatomically irrelevant regions, and multimodal models that add clinical tables frequently rely on variables that were used to assign the diagnostic label in the first place. We study both issues with a deliberately lightweight slice-based encoder (ResNet18 with a one-layer Transformer over slices) on 1,075 baseline T1-weighted scans from ADNI-1. First, we use FastSurfer segmentations as an anatomical reference: YOLOv8 models trained on segmentation-derived labels localize Alzheimer-relevant structures with mAP_50 above 0.96, and a Grad-CAM comparison shows that the image-only classifier frequently attends to the skull, orbits and background. Second, we adapt a CLIP-style image - tabular contrastive framework and organize ADNIMERGE variables along a label-leakage spectrum. Fusion with cognitive scores yields 87.3% three-way accuracy, which we treat as a leakage-driven upper bound rather than an imaging result; fusion with regional volumes yields 73.0%. We observe that the choice of contrastive target changes what the image encoder learns: on MCI vs. CN, the image-only head reaches 52.4% when the encoder is aligned to cognitive scores and 73.8\% when aligned to volumes, although no tabular input is used at inference. Third, restricting the input to a per-subject crop of the medial temporal lobe raises image-only three-way accuracy from 58.7% to 65.1%. All results come from single runs on a small balanced test set, and we report confidence intervals and the protocol differences that prevent direct comparison with published numbers.

0.16

GraM-Diff: A Unified Graph-Mamba Diffusion Framework for EEG-Based Alzheimer's Disease Data Generation and Diagnosis

cs.LG ·2026-08-30 ·M. Tanveer, Ayush Singh Rana, Sanskriti Jain, Arnav Kumar, Aryaman Tiwari +3 more
top venue similarity 0.60
Abstract

Electroencephalography (EEG) is a promising, non-invasive, and cost-effective modality for Alzheimer's disease (AD) detection, but deep learning methods are limited by small and imbalanced clinical datasets. Generative augmentation offers a solution, yet existing approaches rely on inefficient class-specific models or fail to capture complex spatial and temporal brain dynamics. To address this, we propose GraM-Diff, a unified classifier-guided Graph-Mamba diffusion framework for EEG synthesis. It embeds Graph Convolutional Networks within a diffusion U-Net to model inter-electrode connectivity and Bidirectional Mamba state-space blocks for linear-complexity long-range temporal modeling. Latent-space classifier guidance lets a single model generate both healthy and pathological EEG within a shared representation, avoiding fragmented per-cohort pipelines. Across four EEG-based AD benchmarks, synthetic augmentation improves classification, yields superior Context-FID and correlation scores over strong generative baselines, and enhances robustness in data-scarce settings.

0.32

Leakage-Controlled Multimodal Learning for Diagnosis and Progression Prediction in Alzheimer's Disease Research

cs.LG ·2026-10-07 ·Akeem Temitope Otapo, Ghazaleh Khodabandelou, Zuheng Ming, Alice Othmani
similarity 0.60
Abstract

Alzheimer's disease prediction involves irregular visits, heterogeneous measurements and incomplete modalities. This study presents a multimodal multitask framework combining an adapted SFCN MRI encoder, four causal clinical Transformers, shared fusion and task-specific ODE-GRU dynamics. Fine-tuning and LoRA adapt the final two MRI blocks. Task-DRO balances task losses, while Group-CVaR targets cohort and comorbidity strata. Branch-specific input controls, subject-grouped partitions and empirical causality checks support longitudinal evaluation. Across 2,649 subjects and 17,317 visits from ADNI, OASIS-2 and MIRIAD, internal validation yields diagnosis, stage-1 progression and first-stage-1-visit progression AUROCs of 0.935 +/- 0.002, 0.884 +/- 0.003 and 0.870 +/- 0.005, respectively (mean +/- SD across three seeds). Corresponding hybrid AUROCs are 0.951, 0.909 and 0.896. Next-visit MMSE mean absolute error (MAE) is 1.61 points; worst-stratum diagnosis AUROC is 0.827 +/- 0.008. Sampled ADNI explanations identify task-specific input dependence. OASIS-3 external validation yields network and hybrid diagnosis AUROCs of 0.763 and 0.767, hybrid next-visit progression AUROC of 0.764, diagnosis calibration error decreasing from 0.197 to 0.052, and next-visit MMSE MAE of 0.86. Seed-42 paired ablations of six components yield pooled diagnosis and progression AUROC differences between -0.004 and +0.004; removing clinical encoder inputs lowers diagnosis AUROC by 0.272. The framework integrates longitudinal prediction, missing-modality handling, auxiliary comorbidity modelling and subgroup evaluation within a common pipeline.

0.11

A Multimodal Explainable Deep Learning Framework for Alzheimer's Disease Diagnosis using 3D Magnetic Resonance Imaging and Clinical Data

cs.CV stat.ML ·2026-09-11 ·Yusuf Brima, Marcellin Atemkeng, Lakshmana Rao Namamula, Antoine Vacavant
similarity 0.60
Abstract

Dementia is a major and growing global health burden, with Alzheimer's disease (AD) accounting for most cases. Timely and accurate diagnosis is central to managing this burden and increasingly depends on integrating complementary clinical and imaging information. Multimodal deep learning can combine these modalities for AD diagnosis, but how its explanations behave across modalities, fusion strategies, and cohorts remains unclear. We developed an explainable multimodal framework pairing a 3D CNN encoder for T1-weighted MRI with a feedforward network for harmonized clinical and demographic data, comparing varied model setups on three-way and pairwise diagnostic tasks using 6,479 internal records from the ADNI and 1,703 independent records from the OASIS-3. On ADNI, the tabular-only model achieved the highest three-class AUC-ROC of 0.879 and best discriminated cognitively normal (CN) versus mild cognitive impairment (MCI; 0.903), while cross-attention performed best for MCI versus AD (0.861); CN versus AD was highly discriminative overall. On OASIS-3, the vision-only model performed best (three-class AUC-ROC 0.910); CN versus MCI remained difficult, and no fusion strategy consistently outperformed single modalities across tasks and cohorts. SHAP and Integrated Gradients identified the MMSE as the dominant tabular feature in both cohorts, with global feature rankings agreeing strongly in ADNI ($ρ=0.94$) and OASIS-3 ($ρ=0.96$); CAM-based explanations, however, changed with model configuration and cohort. These findings show that multimodal performance and explanations are task, modality, fusion, and cohort-dependent: a dominant cognitive signal persisted across cohorts, but feature contributions and CAM explanations did not, underscoring the need to evaluate explainability under cohort shift rather than as a stable, intrinsic property.

0.10

Different Models, Shared Failures: Auditing Frozen-Encoder Pools for Medical Segmentation

cs.CV cs.AI ·2026-10-30 ·Eunseob Choi, Kyeonghun Kim, Hyuk-Jae Lee, Nam-Joon Kim
top venuecode/datahot direction similarity 0.59
Abstract · Accepted at NeurIPS 2026, Track on Evaluations and Datasets. 47 pages, 8 figures. Code and data: https://github.com/eunseobchoi/CoFailMed

Average segmentation accuracy and model count do not reveal whether models fail on the same cases. We present CoFailMed, an audit of correlated failures in pretrained-encoder pools for medical segmentation. Across five 2D tasks, we evaluate 11 public pretrained encoders (a controlled sample, not a census) using frozen features and separately trained $1\times 1$ readouts with four seeds per encoder. Shared-checkpoint pairs have the highest mean per-case Dice correlation. An expanded 17-encoder analysis shows that distinct checkpoints within the same encoder family remain more correlated than cross-family pairs. At the pooled 33rd-percentile Dice threshold, four-member pools drawn from distinct encoders have mean effective sizes of 1.56-2.92, estimated from failure correlations in pools with enough failures and passes per member. In the primary pool, richer readouts and fine-tuning narrow the Dice-correlation gap between pairs sharing a checkpoint (or the DINOv2-B/S release) and all other pairs. Yet dependence between different encoders can increase, and fine-tuning does not consistently increase effective pool size at 33rd-percentile thresholds recomputed for each training recipe. A smaller between-group gap can coexist with greater dependence. Pool evaluation should therefore report absolute dependence and threshold-specific effective size alongside accuracy and nominal pool size. The CoFailMed release provides aligned per-case traces, analysis scripts and study code to reproduce the central audit results.

0.63