CS Paper Radar

Different Models, Shared Failures: Auditing Frozen-Encoder Pools for Medical Segmentation

Eunseob Choi, Kyeonghun Kim, Hyuk-Jae Lee, Nam-Joon Kim

cs.CV cs.AI ·submitted 2026-10-30 14:21 UTC · v1
top venuecode/datahot direction

Abstract

Average segmentation accuracy and model count do not reveal whether models fail on the same cases. We present CoFailMed, an audit of correlated failures in pretrained-encoder pools for medical segmentation. Across five 2D tasks, we evaluate 11 public pretrained encoders (a controlled sample, not a census) using frozen features and separately trained $1\times 1$ readouts with four seeds per encoder. Shared-checkpoint pairs have the highest mean per-case Dice correlation. An expanded 17-encoder analysis shows that distinct checkpoints within the same encoder family remain more correlated than cross-family pairs. At the pooled 33rd-percentile Dice threshold, four-member pools drawn from distinct encoders have mean effective sizes of 1.56-2.92, estimated from failure correlations in pools with enough failures and passes per member. In the primary pool, richer readouts and fine-tuning narrow the Dice-correlation gap between pairs sharing a checkpoint (or the DINOv2-B/S release) and all other pairs. Yet dependence between different encoders can increase, and fine-tuning does not consistently increase effective pool size at 33rd-percentile thresholds recomputed for each training recipe. A smaller between-group gap can coexist with greater dependence. Pool evaluation should therefore report absolute dependence and threshold-specific effective size alongside accuracy and nominal pool size. The CoFailMed release provides aligned per-case traces, analysis scripts and study code to reproduce the central audit results.

Comment
Accepted at NeurIPS 2026, Track on Evaluations and Datasets. 47 pages, 8 figures. Code and data: https://github.com/eunseobchoi/CoFailMed

Closest papers

Nearest neighbours by meaning across the whole index.

CRS-Bench: A Reference-Relative Reliability Benchmark for Medical Image Encoders

eess.IV cs.AIcs.CV ·2026-08-22 ·Xingtao Lin, Hangqi Ren, Caiwan Sun, You Chen
benchmark similarity 0.63
Abstract · 10 pages, 7 figures. Submitted to WACV 2027

Pretrained image encoders are central to medical image classification, where expert annotation is costly and task-specific cohorts are often limited. As the model space expands from general-purpose to broad-medical and specialty-specific encoders, selecting the representation becomes a substantive modeling decision. Clean-test discrimination alone is insufficient for this purpose: encoders with similar AUROC can differ in calibration, label efficiency, and stability under acquisition perturbations or distribution shift. We introduce CRS-Bench, a controlled benchmark for multi-objective medical encoder selection. CRS-Bench evaluates 15 pretrained encoder families across dermatology, ophthalmology, and radiology using ISIC 2019, APTOS 2019, and CheXpert, with CheXpert-to-MIMIC-CXR as an observed institutional shift, yielding 17,575 controlled run records and 3,515 seed-aggregated metric rows. Each encoder is characterized along four operational reliability dimensions: discrimination, calibration, label efficiency, and robustness. We summarize these dimensions using the Clinical Reliability Score (CRS), a Pareto-aware, reference-relative score combining dominance, profile balance, and worst-axis performance. AUROC and CRS are positively associated but not decision-equivalent: 21 of 105 pairwise orderings reverse, with a mean absolute rank displacement of 1.87. Paired-seed bootstrap analysis identifies PanDerm, MedSigLIP, and MedGemma as a stable leading reliability tier rather than a statistically resolved single leader. CRS-Bench provides a controlled framework for selecting medical image encoders from multi-axis reliability profiles rather than clean-test AUROC alone.

0.33

Readout and Operating-Point Sensitivity in Event-Stream Candidate Selection

cs.CV ·2026-10-27 ·Yifan Shuai
similarity 0.61
Abstract · 12 pages, 4 figures, including supplementary material

Event-triggered recording needs a useful combination of target capture and false triggers, yet representation comparisons can change with readout and threshold calibration. We evaluate real event accumulations from 520 DailyDVS-200 clips and 47 participants using participant-disjoint training, validation, and testing. The original study varies frozen encoder scale, accumulation duration, and temporal view count; a post-review extension adds two supervised-pretrained convolutional encoders, a 61,586-parameter trained CNN with three seeds, ten repeated participant partitions, and calibration sensitivity. At 50 ms/eight views under the primary handshake-or-fall policy, DINO-S CLS captures 101/132 targets with 40/388 false triggers, versus 78/132 and 35/388 for patch mean. DINO-B CLS has lower selected-threshold capture but higher fold-wise low-FPR partial AUC (0.746 versus 0.732). MobileNetV3-Small captures 97/132 with 53/388 false triggers, demonstrating why lightweight baselines and actual operating points matter. Across ten dependent repartitions, mean normalized partial AUC is 0.738 for DINO-B CLS and 0.674 for MobileNet. The original LeJEPA S-to-B capture difference is 8.3 points, but its multiplicity-adjusted interval includes zero. Duration and view-count effects remain policy dependent. We find no established JEPA-specific advantage. The evidence concerns offline action-defined candidate selection on previously used development data; it does not establish personal recording value, continuous false alarms per hour, or eyewear energy.

0.36

Representation Risk in Pretrained Image Encoders

cs.CV econ.GN ·2026-09-28 ·Ardyn Nordstrom, Morgan Nordstrom, Vamuyan Sesay, Matthew D. Webb
benchmark similarity 0.61
Abstract

Applied researchers increasingly convert images into features with pretrained encoders, then use those features in a downstream prediction model. The encoder is often treated as an implementation detail. We show that it can instead be a consequential source of model uncertainty. We call this uncertainty representation risk: plausible pretrained encoders map the same images into different feature spaces and can yield sharply different out-of-sample conclusions from predictive performance. We compare ten modern and legacy frozen encoders across applications involving house prices, racehorse performance, breast-cancer histology, chest radiographs, continuous facial age, and rice disease. With common dimension control, heads, and group-safe splits, validation selects SigLIP 2 for houses, raising test $R^2$ from 0.396 for ResNet50 to 0.629, and DINOv2 for horses, raising $R^2$ from 0.029 to 0.105. No encoder is best in every task. Candidate procedures are constructed using training data and compared on a separate validation partition. The selected procedure reaches 0.658 for houses and 0.979 accuracy for pneumonia. Fixed-split gains are small for horses and rice, while repeated partitions reveal instability in horse feature union. Continuous age selects SigLIP 2 at 4.786 years MAE. The principal representation gaps persist with neural heads, similarly sized DINOv2 and ViT models, and limited adaptation. These results support a simple workflow: benchmark plausible representations, select on locked validation data, combine only when separate validation evidence justifies the additional cost, and report paired and split-level uncertainty. We implement this workflow in LOOKAGAIN-ML, the software package used to conduct the analyses in this paper.

0.31

Exact Dice Degradation Envelopes for Label-Free Segmentation Update Selection

eess.IV cs.LG ·2026-10-01 ·Yuvraj Verma
similarity 0.60
Abstract · 18 pages, 7 figures, 6 tables. Includes mathematical proofs and a three-seed study on ClinicDB, Massachusetts Buildings, and Kvasir-SEG

Test-time segmentation updates can improve an unlabeled input while damaging another. Confidence and transformation consistency can rank candidates, but do not in themselves bound the loss caused by returning a changed mask. We derive the exact largest decrease in binary Dice between a baseline and a candidate, maximized over every possible unknown reference mask on the same pixels. A maximizing reference always lies inside baseline foreground: three observable mask counts reduce the problem to at most four reference-cardinality checks. Accepting an output only when its envelope is below a budget gives a deterministic, per-case Dice degradation limit relative to the baseline. A finite grid of logit interpolations permits partial candidate outputs without extra network forwards. Exhaustive and randomized validation checks 5,026,592 reference masks with no discrepancy. We evaluate six independently trained MK-UNet sources, three seeds per task, on ClinicDB, Massachusetts Buildings and the external Kvasir-SEG cohort, including appearance corruptions. Across 17,808 case-condition-seed evaluations, 0 certificate violations occur in the checked candidate comparisons. At a one-point Dice budget, exact versus loose interpolation changes the returned mask in the following fractions of episodes (ClinicDB: 51.0% versus 38.7%; Buildings: 62.1% versus 53.1%; Kvasir-SEG: 52.3% versus 34.9%). Mean Dice effects and useful-update rejection are reported separately from admissibility. An exploratory oracle-presence-bit ablation examines how weak supervision relaxes the empty-baseline restriction. The envelope quantifies relative mask-change risk; it does not certify anatomical correctness, preserve other metrics, or guarantee adaptation benefit.

0.33

MedSegBenchmarker: A Raw-Count-First Framework for Controlled 2D Medical Image Segmentation Benchmarks

cs.CV cs.AI ·2026-08-30 ·Vanessa Borst, Lukas Horn, Daniel Grillmeyer, Thomas Prantl, Samuel Kounev
benchmark similarity 0.60
Abstract · 10 pages, 4 figures;

Despite rapid advances in MIS, fair and reproducible comparisons of segmentation models remain challenging due to heterogeneous datasets, inconsistent evaluation protocols, and rapidly evolving architectures. In particular, comparisons often implicitly assume that model rankings are invariant to data partitioning, preprocessing, metric aggregation, uncertainty estimation, and computational constraints. The lack of extensible and unified evaluation frameworks further limits systematic investigation of new models, datasets, and training paradigms. We present MEDSEGBENCHMARKER (MSB), a configuration-driven framework for controlled benchmarking of 2D MIS. It integrates duplicate and near-duplicate image detection, group-aware data splitting, YAML study specifications, resumable training, hyperparameter optimization, cross-validation, and checkpoint-based evaluation. Rather than retaining only aggregate performance measures, MSB exports sample- and class-level pixel counts and predictions together with the evaluation context. These elementary artifacts enable post-hoc analyses without repeated inference. We demonstrate MSB in a case study involving three heterogeneous 2D datasets and multiple MIS and general-purpose vision models evaluated at 256- and 512-pixel input resolutions. Reaggregation of identical predictions changes the top-ranked architecture in three of six dataset-resolution settings, despite high rank correlations between aggregation strategies. Increasing input resolution produces model- and dataset-dependent performance gains and losses that must be considered alongside empirically measured inference complexity. These results show that seemingly minor choices in evaluation and experimental setup can affect benchmark conclusions. MSB, available at GitHub, provides a practical and extensible basis for making benchmark conditions and evaluation choices explicit and reproducible.

0.46

Leveraging Segmentation Representations for Efficient Classification: A Self-Configuring Framework Based on nnU-Net

cs.CV cs.AI ·2026-11-17 ·Renjun Cai, Antonio Javier Gallego, Félix Fuentes-Hurtado
benchmark similarity 0.60
Abstract

We propose a self-configuring framework that extends the nnU-Net workflow to both segmentation and classification in 3D medical imaging. Building on nnU-Net's self-configuring method, the framework reuses representations learned by a segmentation model for image-level classification. Its encoder features and predicted segmentation probabilities are used by a lightweight classifier. Two information-sharing strategies are investigated. In the frozen-backbone branch, features are augmented with region-of-interest information, predicted foreground volume, and segmentation confidence. In the adaptation branch, the final encoder stage is partially fine-tuned for classification, with an auxiliary segmentation loss to preserve segmentation-related information. Additional five-fold experiments showed that more complex configurations did not consistently improve classification performance. On the public validation leaderboard, our selected framework achieved an Overall score of 0.8056. In the official FLARE 2026 Task 2 final evaluation, our framework ranked first overall, achieving the highest DSC, NSD, and AUROC across all four testing tasks, including two hidden testing tasks. Local inference measurements also remained below the challenge limits of $60 \mathrm{s}$ per case and $4 \mathrm{GB}$ GPU memory. These results demonstrate the practical value of reusing segmentation representations for classification while maintaining a simple and efficient framework.

0.18

BRACHIO: Broad Representations Across Centres for Head-and-neck Imaging Oncology (HECKTOR 2026)

cs.CV ·2026-10-29 ·Roxanne De Maeyer, Ine Dirks, Yannick Brackenier, Simon DeKeyser, Jef Vandemeulebroucke +1 more
published similarity 0.60
Abstract · HECKTOR Challenge 2026, MICCAI, head and neck cancer, PET imaging

The HECKTOR 2026 challenge benchmarks machine learning for head and neck cancer, where teams delineate primary and nodal tumour volumes, perform TN staging, and predict recurrence-free survival (RFS). This report describes the submissions for the HECKTOR challenge of team nucli. As the three tasks span both dense and global information from multicentric PET/CT scans, we utilise self-supervised pre-trained encoders, training a 2D DINOv2 encoder (PET-DINOv2-MIPs) on HECKTOR 2026's PET scans. Our final test submission ensembles a DynUNet trained from scratch with a SwinUNETR whose Swin trunk was initialised from a SimMIM-pre-trained checkpoint for segmentation, reaching a mean Dice of 0.5409. For TN staging, GTVp/GTVn geometric features from the segmentation masks are fit to stage probabilities by logistic regression (LR) and fused with PET-DINOv2-MIPs deep features (PCA + LR) via a second-level LR, reaching balanced accuracies of 0.3962 (T-stage) and 0.6432 (N-stage). For the RFS prognosis task, we fine-tune the last two blocks of the PET-DINOv2-MIPs ViT-S encoder jointly with an MLP head under a CoxPH loss, concatenating clinical covariates with the imaging features, reaching a test Harrell's C-index of 0.6577 and a weighted challenge score of 0.5802. The prognosis result is comparable to the best entry of the previous edition and consistent with our internal cross-validation, while our segmentation result is well below it and limits the staging results that depend on it.

0.32

HippoMamba: A Mamba-augmented network for hippocampal segmentation and serial volumetry in Alzheimers disease

cs.CV cs.LG ·2026-10-26 ·Dawa Chyophel Lepcha, Sophie A. Martin, Pierrick Coupe, Shabbir Syed-Abdul
similarity 0.59
Abstract · 22 pages, 7 figures, 5 tables

Hippocampal atrophy is among the earliest structural markers of Alzheimer's disease, and reliable hippocampal segmentation across serial MRI visits is a prerequisite for measuring it. We present HippoMamba, a network that combines a 3D convolutional encoder and decoder with a Mamba selective state space block at the bottleneck, designed to process one or more MRI visits of a subject. On the Medical Segmentation Decathlon hippocampus dataset (260 subjects, five-fold cross-validation), HippoMamba obtained a mean Dice similarity coefficient of 0.8861 $\pm$ 0.0094, the highest among six convolutional and transformer-based methods trained with the same folds and patch size, and its per-subject Dice was significantly higher than that of each method (Holm-corrected Wilcoxon tests, $p \leq 0.013$). Its mean 95th percentile Hausdorff distance (1.45 mm) and average surface distance (0.44 mm) were the lowest of the compared methods, although they did not differ significantly from those of Attention U-Net, and the Hausdorff distance did not differ significantly from that of SegResNet. Without retraining, the five-fold ensemble was applied to 600 T1-weighted sessions from 150 participants of the OASIS-3 cohort. In sessions meeting a registration quality criterion, predicted hippocampal volumes ranked consistently with FreeSurfer volumes (Pearson r = 0.778, 95% CI 0.699 to 0.838; ICC(3,1) = 0.772) but were systematically smaller by about 27%. In a pre-specified analysis of participants followed for at least two years, annualised volume change derived from per-visit segmentation was moderately correlated with that of FreeSurfer (r = 0.503, 95% CI 0.319 to 0.659), with a larger mean rate. These results support the use of HippoMamba for hippocampal segmentation and for ranking hippocampal volume within a cohort, with absolute volumes and rates of change interpreted relative to the reference method.

0.30