CS Paper Radar

Dynamic State Estimation from Sparse PMUs via Physics-Informed Graph Neural Operators

Huy Hoang Le, Haoguang Wang, Christian Moya, Marcos Netto, Guang Lin

cs.LG eess.SY ·submitted 2026-11-07 04:37 UTC · v1
benchmark

Abstract

This paper proposes a physics-informed graph neural operator for power system dynamic state estimation. From a sparse, intermittent measurement window at a few generator buses, the operator estimates the rotor-angle and speed trajectories of all machines, unmeasured ones included, in one forward pass. A graph-attention encoder processes the measurements, and the swing equations are imposed as a hard constraint or as a soft one with a learned correction that absorbs model errors. It is trained on simulated measurements, without state labels. With several phasor measurement units, masked training hides one from the input but keeps it in the loss. On four transmission systems, simulations show that the operator is the most accurate estimator that neither optimizes per scenario nor uses state labels, except on the smallest system at large model errors, where tuned Kalman smoothers are better. Networks trained on simulated states are more accurate on the two smallest systems but not on the 118-bus system, where the operator is faster and more accurate than hard-constrained moving-horizon estimation. Under model errors, it matches or outperforms an optimization-based benchmark at a fraction of its cost. The results hold for a detailed machine model with exact parameters seen only through voltage phasors.

Comment
10 pages, 10 figures, 4 tables

Closest papers

Nearest neighbours by meaning across the whole index.

Unified Heterogeneous Graph Neural Network solver for Power Flow, Optimal Power Flow and State Estimation

eess.SY cs.LG ·2026-09-15 ·Ferran Bohigas-Daranas, Hamid Latif-Martínez, Eduardo Prieto-Araujo, Oriol Gomis-Bellmunt, Pere Barlet-Ros
similarity 0.66
Abstract

Power Flow (PF), Optimal Power Flow (OPF), and State Estimation (SE) are fundamental problems in power system analysis, but solving them is computationally expensive. Graph Neural Networks (GNNs) have been proposed as fast surrogates, yet existing solvers are trained for a single problem at a time, producing narrow models that must be rebuilt for each new task. We propose a more general approach: a single Heterogeneous Residual Gated Graph Convolutional Network that solves all three problems with one shared backbone. Rather than learning one mapping, the model learns a reusable representation of how the network behaves, from which PF, OPF, and SE can each be estimated. Trained jointly on the three problems across diverse topologies and loading conditions, and evaluated on the IEEE 14-bus and 118-bus systems, the shared model matches the accuracy of task-specific GNN solvers and stays robust on unseen loading levels and topologies. These results show that a single model can capture the basic operation of a power network and serve several analysis tasks at once, a first step toward a foundation model for power systems.

0.11

Toward Out-of-Distribution Generalization in Neural AC Power Flow

cs.LG cs.AI ·2026-11-18 ·Ojas Sanghi, Anvita Bhagavathula, Alvaro Carbonero, Priya L. Donti
published similarity 0.65
Abstract · 11 pages, 5 figures. Accepted as an oral presentation at the NeurIPS 2026 Workshop on AI Foundations for Power Grids: From Models to Deploym…

Growing uncertainty in power system operations from renewables integration, extreme weather, and data center loads challenges the reliability of traditional power flow solvers at scale. Machine learning-based proxies are a potentially promising alternative, but the prohibitive cost of generating training data for large grids makes out-of-distribution generalization a key capability for deployment; currently, models trained on small grids lack that capability. In this work, we systematically evaluate how physics-informed losses, multi-grid training, and perturbation-based data augmentation improve the zero-shot transfer of three graph neural network-based power flow models from smaller systems to a larger, unseen 500-bus system. We find that (1) physics-informed losses improve transfer relative to purely supervised objectives; (2) multi-grid training on smaller systems matches the best single grid but does not close the gap to target-grid training; (3) perturbation-based augmentation on edge attributes improves transfer by up to 54.6%; and (4) random line/generator dropout does not consistently improve performance.

0.40

Learning-Based Power Flow Estimation with Sparse PMU Deployment in Power Systems

eess.SY ·2026-10-09 ·Van-Hai Bui, Quang Manh Hoang, Akhtar Hussain, Wencong Su
similarity 0.63
Abstract · 14

Accurate monitoring of power flow is fundamental to the secure and reliable operation of modern power systems. Existing data-driven power flow estimation methods typically assume that synchronized measurements are available at every bus, requiring extensive deployment of phasor measurement units (PMUs). Such dense sensing infrastructures substantially increase installation, communication, and maintenance costs. This paper proposes a learning-based framework that minimizes the number of installed PMUs while maintaining high-accuracy systemwide power flow estimation. Instead of relying on measurements from all buses, the proposed method identifies an informative subset of buses whose synchronized measurements are sufficient to accurately reconstruct branch power flow across the network. To this end, a neural network is developed to learn the nonlinear relationship between PMU measurements and system-wide power flows, and multiple PMU deployment scenarios are evaluated to quantify the trade-off between measurement availability and estimation accuracy. The results enable utilities to identify cost-effective PMU placement strategies that balance deployment cost and prediction performance. Case studies on the IEEE 30-bus test system demonstrate that the proposed framework significantly reduces the number of required PMUs while maintaining accurate power flow estimation.

0.18

Machine Learning-Based State Estimation for an Actual Transmission System Using Field PMU Data

eess.SY ·2026-09-22 ·Shiva Moshtagh, Nihar Thakkar, Anamitra Pal, Evangelos Farantatos
published similarity 0.62
Abstract · Accepted for presentation at the 60th Hawaii International Conference on System Sciences (HICSS-60), 2027

Time-synchronized state estimation (SE) plays a critical role in ensuring real-time situational awareness in modern power systems. However, achieving full system observability using phasor measurement units (PMUs) is often impractical due to cost and deployment constraints. Moreover, SE operation at PMU timescales imposes stringent requirements on latency, robustness, and reliability that are difficult to satisfy using conventional iterative hybrid SE techniques under incomplete observability by PMUs. This paper evaluates the feasibility of deploying deep neural networks for PMU-timescale, time-synchronized SE in real-world PMU-unobservable transmission systems using actual data from a US power utility. Key contributions include a systematic assessment of estimation accuracy, scalability, and computational performance under realistic operating conditions.

0.34

Hard-Constrained Probabilistic Factor Graph Neural Network for Distribution System State Estimation under Non-Gaussian Uncertainty

eess.SY ·2026-09-28 ·M. Furqan Azam, Marta Vanin, Chris Hermans, Geert Deconinck
similarity 0.61
Abstract · Preprint. Submitted to Sustainable Energy, Grids and Networks

Robust and accurate state estimation is fundamental for the reliable operation and monitoring of active distribution networks. Conventional numerical estimators, such as weighted least squares, are computationally slower and often suffer from convergence issues in the presence of sparse measurements affected by non-Gaussian noise. Physics-informed neural networks have recently emerged as a promising alternative by incorporating physical principles through residual-based penalty terms in the objective, which can improve robustness to noise and computational efficiency. However, such penalty-based approaches do not guarantee strict enforcement of physical constraints during inference and provide limited support for principled uncertainty modeling. To address these limitations, we propose a novel Hard-Constrained, Physics-Informed Factor Graph Neural Network (HCP-PINN) that formulates distribution system state estimation as a probabilistic constrained estimation problem on a factor graph. The proposed approach explicitly models non-Gaussian (pseudo-)measurement uncertainty through flexible, closed-form likelihood-based loss functions. It further incorporates a differentiable optimization-based estimation layer that strictly enforces nonlinear equality constraints and measurement consistency, producing physically feasible state estimates during both training and inference. To the best of our knowledge, this is the first PINN-based DSSE framework to combine hard physical constraints with non-Gaussian uncertainty modeling for unbalanced three-phase networks. Numerical experiments demonstrate that the proposed method delivers more accurate and physically consistent state estimates than deep learning benchmarks and numerical estimators, while exhibiting greater robustness to network model errors and improved computational efficiency under realistic measurement scenarios.

0.31

Sensor-Aware Joint Data Fusion and State Estimation under Sparse Multi-rate Distribution Grid Sensing

cs.LG ·2026-10-10 ·Pooja Algikar, Stefano Fenu, Kumarsinh Jhala, Siby Plathottam
similarity 0.61
Abstract

Distribution-system state estimation is a growing necessity for the modern power grid as the addition of local storage and generation add system complexity that an operator or aggregator is not able to directly monitor. Classical methods work well when all system elements are time-synchronized and at least partly observable, but multi-rate monitoring of sparse heterogeneous sensors typically relies on machine learning approaches. It is a common practice in the literature to structure this task as a two-stage pipeline, first fusing data from disparate sensors and then feeding the fused pseudo-measurements to a separately trained state estimator. We propose a heterogeneous latent graph ODE in which measurement functions and sampling processes are typed and localized on specific buses, paired with a graph- transformer state estimator solving DSSE specifically for multi-rate heterogeneous sensor placements, and demonstrate its effectiveness across multiple IEEE standard topologies as observability degrades.

0.26

Learning-Based Augmentation and Adaptation for Grid Sim-to-Real Model Discrepancy

eess.SY ·2026-09-18 ·Sayak Mukherjee, Kyung-Bin Kwon, Ramij R. Hossain, Marcelo Elizondo
benchmark similarity 0.60
Abstract · 12 pages, 5 figures, 3 tables

Modern power systems can encounter increased discrepancy between the operators' simulation model and the actual true dynamics of the grid, driven by uncertainties caused by integration of new inverter-based resources (IBRs), large loads, unmodeled dynamics, parameter drifts, etc., to name a few. All of these impact the control room operations, where some critical oscillations may not be captured during the transient studies. To circumvent these issues, we propose a learning-augmented hybrid approach where the operator simulation model is supplemented with artificial intelligence (AI)-learned residual models using the phasor measurement unit (PMU)/ point-on-wave (PoW) based sensed trajectory data. The physics-based operator model provides interpretability and structural consistency, while the learned residual captures discrepancies caused by non-idealities. The learned model employs advanced neural architectures and consists of a backbone encoder and multi-head decoder layers for heterogeneous grid channels. Subsequently, we formulated a continual learning-motivated adaptation framework such that the baseline residual AI model can also be updated when the underlying real grid model changes in future conditions. Extensive numerical simulations are performed on the IEEE 68-bus benchmark model with a diverse set of disturbances, and different state-of-the-art predictive architectures involving recurrent learners, latent neural ODEs, and transformers are explored to demonstrate both residual learning and adaptation capabilities.

0.28

GridSFM: A Foundation Model for Solving AC Optimal Power Flow

eess.SY cs.LGmath.OC ·2026-09-24 ·Luke Bhan, Weiwei Yang, Margaret Capetz, Baosen Zhang
theory similarity 0.58
Abstract · 19 pages

We introduce GridSFM, a framework that combines a pretrained foundation model across grid topologies with physics-informed fine-tuning for solving AC Optimal Power Flow (AC-OPF) at scale. It is a $15$ million parameter physics-inspired graph neural network pretrained across $54$ topologies of $500$ to $4{,}000$ buses. Our model attains a $2.45\%$ zero-shot generation-cost error on a $10{,}000$ bus case held-out operating conditions with no degradation as system size grows. Building on this, we pair the pretrained backbone with a physics-informed fine-tuning design based on Newton's method for power flow. With only $100$ solved instances, GridSFM adapts to unseen grids up to $10{,}000$ buses. We show it out performs single topology, dedicated neural network models that are trained more data, both in terms of cost and solver iterations when deployed as warm starting points. In designing this foundation model, we overcome the fact that the feasible set for AC-OPF can be disconnected. This is an obstruction that prevents any continuous neural network from approximating the solution map. To do so, we lift the problem and relax its constraints with logarithmically penalized slacks. We prove that the resulting elastic feasible set is contractible, that the AC-OPF minimizers remain minimizers of the elastic problem above an explicit penalty threshold, and that projecting an approximate solution back onto the AC-OPF feasible set is well posed. We release all models, data, and code so that the community can build on a shared starting point for AC-OPF.

0.40