Dexterous robotic fingers require coordinated joint motion and adaptability to object contact, while independently actuating multiple joints increases the complexity of the transmission mechanism. This paper presents a hybrid tendon--linkage robotic finger with four mechanical degrees of freedom driven by three actuators. The MCP abduction/adduction joint is driven through a bevel gear, while MCP and PIP flexion/extension are driven by separate bidirectional tendon transmissions. The DIP joint is not independently actuated but is coupled to the PIP joint through a four-bar linkage with a torsional spring and mechanical stopper. The tendon routing also introduces mechanical coupling between the MCP and PIP joints. Kinematic analysis was conducted to describe the coupled and adaptive motions, and experiments were performed to evaluate the joint motion characteristics. ArUco-based measurements showed that the coupled motion closely matched the theoretical prediction, whereas the adaptive motion was partially limited by interference between linkage components. The fabricated finger demonstrated different contact postures with cylindrical, cuboid, and irregularly shaped objects, and the mean peak fingertip force was 4.56 N. The proposed mechanism provides both coupled motion and contact-dependent adaptation without requiring an additional actuator for the DIP joint.

Comment
This manuscript has been submitted for possible publication

Closest papers

Nearest neighbours by meaning across the whole index.

Design of a Fully Actuated 4-DOF Robotic Finger With Joint-Specific Hybrid Remote Actuation

cs.RO ·2026-10-07 ·Hyojae Kang, Hyun-mok Jung, Joonho Lee, Dongil Park, Hyunmin Do +2 more
similarity 0.78
Abstract · 10 pages, 10 figures. This manuscript has been submitted for possible publication

This paper presents a fully actuated 4-DOF robotic finger using a joint-specific hybrid remote-actuation architecture. The metacarpophalangeal (MCP) joint is driven by two coordinated rigid-link transmission sets, whereas the proximal interphalangeal (PIP) and distal interphalangeal (DIP) joints are independently actuated by closed-loop wire transmissions incorporating circular rolling-contact joints (RCJs). A larger transmission radius is used at the PIP joint than at the DIP joint. The RCJ wire geometry maintains the total wire-loop length during joint rotation, and the DIP wire routing is designed so that PIP motion does not affect its differential actuation for a fixed MCP configuration. The distal wire transmission, MCP linkage, and fingertip kinematics are analytically modeled. In experiments, the transmission behavior was quantitatively evaluated from the ball-screw displacements measured using ArUco-marker tracking. MCP actuation produced measurable displacements of the PIP and DIP transmission units, whereas isolated PIP and DIP actuation with the MCP fixed supported the intended mechanical decoupling between the distal transmissions. The mean peak fingertip forces under isolated MCP, PIP, and DIP actuation were 21.28 N, 9.22 N, and 5.75 N, respectively. The resulting finger postures were also examined using objects of different geometries and sizes.

0.37

Design and Validation of an Antagonistic Tendon-Driven Dexterous Robotic Hand with Bidirectional Operation

cs.RO ·2026-09-28 ·Chunghyeon Lee, Hyukjun Kwon, Sungeon Kim, Saehyun Moon, Seokhwan Jeong
similarity 0.72
Abstract

Dexterous robotic hands typically reproduce human hand morphology but inherit its one-sided grasping workspace, requiring wrist or arm reorientation to grasp from the opposite side. Existing reversible hands generally rely on non-anthropomorphic, soft, or task-specific finger arrangements, whereas conventional five-digit anthropomorphic hands remain designed primarily for palmar-side grasping. This paper presents an anthropomorphic, human-scale (200 mm length), lightweight (220 g), 3D-printed, 17-DoF robotic hand built on a bidirectional antagonistic tendon-routing mechanism, in which flexion/extension (except the coupled joint) and abduction/adduction at joints are actively driven without passive return springs. The proposed routing mechanism allows all degrees of freedom to cross their neutral configuration and form grasp closures on either the palmar or dorsal side. Experimental evaluation demonstrates an average motor-to-joint transmission error of 3.0%, an average joint transmission bandwidth of 13.2 Hz, a maximum fingertip force of 29 N, and a positioning repeatability up to 0.15 mm. The hand further achieves a Kapandji score of 8, successfully performs all 33 GRASP Taxonomy grasp types, and performs palmar- and dorsal-side grasping tasks, validating bidirectional operation in a compact, human-scale platform.

0.34

A Compact Robotic Finger with 2-DoF MCP Joint Embedding DoF-Selective Passive Continuously Variable Transmission for Wide Force-Speed Operating Range

cs.RO ·2026-09-01 ·JaeHyung Jang, Jee-Hwan Ryu
similarity 0.71
Abstract · 9 pages, 4 figures

This letter presents a compact two-degree-of-freedom (DoF) robotic finger with a flexion-selective passive continuously variable transmission (CVT) to achieve a wide force-speed operating range. Inspired by the functional differentiation of the human metacarpophalangeal (MCP) joint, the proposed mechanism realizes DoF-specific transmission differentiation by selectively assigning passive CVT to the flexion-extension DoF while preserving direct transmission for abduction-adduction. For a wide force-speed operating range, a force-responsive passive CVT is embedded in the flexion pathway, while direct transmission is preserved for the abduction-adduction pathway. To selectively realize transmission adaptation within a multi-DoF MCP mechanism, an output-side passive CVT employing a moving-pulley-inspired wire-routing structure is introduced. The resultant force generated by the wire tensions acting on the pulley that passively increases the flexion moment arm and transmission ratio according to the applied load without additional actuators, sensors, or control. Experimental results demonstrate a maximum output-force amplification of 4.19-fold and a mean amplification of 3.6-fold across the tested flexion angles ranging from 15 degrees to 75 degrees through moment-arm adaptation, thereby substantially expanding the achievable force-speed operating range. Furthermore, dexterous ball-rolling experiments verify that passive transmission adaptation can be achieved while preserving abduction-adduction functionality. These results demonstrate a scalable transmission design strategy for compact multi-DoF robotic hands.

0.23

PACT: Pose-Robust Actuation Co-Design for Tendon-Driven Robotic Hands

cs.RO ·2026-11-03 ·Prashant Kumar, Rachael Granberry, Taylor Niehues, Andrew A. Stanley, Gabe Pirie
similarity 0.70
Abstract

Humanoid robotic hands must provide sufficient force, speed, and backdrivability within a human-scale envelope. Tendon-driven transmissions address this challenge by relocating actuators to the palm and forearm, but routing paths, moment arms, and capstan dimensions jointly determine both force capability and joint speed, so selecting them sequentially satisfies one requirement at the expense of the other. This paper presents a pose-robust actuation co-design for tendon-driven robot hands (PACT) framework that optimizes tendon routing, moment arms, and capstan dimensions under pose-dependent force requirements and drivetrain-bandwidth constraints. A feasible-force formulation enforces actuator bounds and equilibrium at all joints, while a max-min objective maximizes task-force coverage at the weakest pose. Applied to a four-degree-of-freedom finger, the framework produces an asymmetric N + 1 tendon topology using quasi-direct-drive actuators. Across eight poses, the design achieves task-force coverage of 0.88-1.00 and a predicted 5 Hz minimum isolated-joint flexion/extension bandwidth within a 70th-percentile human-size envelope. Prototype measurements deviate from predictions by up to 24.5%, primarily due to unmodeled transmission losses. These results indicate that co-designing routing with the drivetrain can meet pose-dependent force requirements without relaxing the bandwidth constraint, paving the way for human-sized robotic hands with human-level performance.

0.08

PHD-Hand: A Printable Humanoid Dexterous Hand with Linkage-Driven 3-DOA Digits

cs.RO cs.AI ·2026-10-21 ·Neel Adwani, Muhaiminul Islam Akash, Saffia Ouali, Ethan Liu, Cong Wang
published similarity 0.68
Abstract · Submitted and Accepted at IEEE-RAS International Conference on Humanoid Robots (Humanoids 2026). 8 pages. Supplementary video: https://lnkd.…

Currently, dexterous humanoid robot hands are widely considered the final hardware bottleneck that hampers generalist robots from physically assisting people at home and work. As conventional tendon-driven designs suffer from high cost, demanding maintenance, poor reliability, and short durability, alternative linkage-driven designs have increasingly gained attention. Despite their potential to avoid the weaknesses of tendon-driven hands, integrating multiple degrees of actuation (DOA) in a single digit with linkage drivetrains is a challenge for design and fabrication. Only a few studies have managed to present functional humanoid hands that are completely linkage-driven and have at least three DOAs per digit without compromising actuator placement and other design preferences. Our work introduces a new linkage-driven hand featuring a unique flexure hinge. Together with elastic drive rods made of spring steel, the linkage drivetrains are significantly simplified. Unlike other linkage-driven designs of similar dexterity, our design does not require many miniature moving parts. As a result, the hand can be fabricated easily with a budget 3D printer. This not only significantly lowers the barrier to entry for using and developing dexterous humanoid robot hand functions, but also allows the hands to be sized much closer to regular human hands. The design offers desirable kinematic advantages as well. A prototype is evaluated for grasping and object manipulation. In addition, this paper presents our latest findings on kinematics and control of the hand.

0.25

A fully articulated humanoid dexterous hand with human-level joint structure enabled by linkage-based actuation

cs.RO ·2026-10-27 ·Jihao Li, Jianguo Wang, Haotian Guo, Yanzhe Wang, Guodong Lu +1 more
similarity 0.68
Abstract

Humanoid dexterous hands are a core component of embodied intelligence, enabling robots to translate high-level intent into rich and adaptive physical interaction. However, existing designs remain constrained by a persistent trade-off among anthropomorphic kinematic complexity, mechanical robustness, load capacity and control simplicity, limiting dexterous manipulation in unstructured environments. Here we present Torch-Hand, a fully articulated humanoid dexterous hand that replicates the joint structure and motion hierarchy of the human hand with 21 degrees of freedom (DOF), comprising a highly articulated five-DOF thumb and four DOF in each of the remaining fingers. The differentiated thumb integrates multi-axis CMC motion to provide broad opposition and flexible contact orientation relative to the four fingers. Unlike tendon-driven or hybrid actuation approaches, Torch-Hand adopts an entirely linkage-based transmission architecture. By integrating screw-linkage actuation, the hand achieves high grasping force and substantial payload capacity while maintaining a compact anthropomorphic form. Its actuation architecture is optimized for control tractability, with all actuators integrated within the palm and arranged in a serial-robot-like configuration that establishes a direct correspondence between motor motion and joint kinematics. This architecture mechanically decouples functional DOF to reduce unintended inter-joint motion propagation, while allowing independently addressable DOF to be actively coordinated into coupled multi-joint motion patterns during complex manipulation. Comprehensive experiments assess reachable workspace, coordinated fingertip trajectories, thumb opposition, 33-grasp taxonomy coverage, grasping force, payload capacity and task-level manipulation. These results establish Torch-Hand as a robust hardware foundation for dexterous embodied manipulation.

0.22

Development of a Voice-Controlled Tendon-Driven Bionic Hand

cs.RO cs.HCeess.SY ·2026-08-25 ·Urja Kohli, Shagata Chanda, Kritika Gandhi, Charu Nigam, Aditi Surya Kamal +1 more
similarity 0.63
Abstract · 20 pages, 11 figures, 6 tables. Open-access preprint intended for journal or conference submission

The impairment of the hands can seriously affect the abilities of every individual to perform the every-day activity, so the design of stable and controllable support devices is a significant field of study. This paper is about the design and implementation of an automated bionic hand which is dedicated to the coordinated finger movement through the simplified and efficient actuation mechanism. The method that the proposed system was designed on is the tendon-based method whereby the servo motors generate the movement of the fingers, with assistance of the angular control which is calibrated. An actuation is controlled by a microcontroller that will be programmed by use of an Arduino-based microcontroller to carry out programmed gestures that include open hand, fist, pinch and half flexion. It has an interface that is voice command enabled to make it easy to interact with a Bluetooth based sender receiver architecture which offers an option of executing trained commands which are immediately converted to finger actions. To explore the motions behavior, finger coordination and control response to the input, the behavior of the experiment system is tested. The actuation of the fingers was found to take a total of about 7-8 seconds to achieve full flexion of all fingers in a sequence. The system showed repetitive and constant motion throughout several actuation cycles without loss of any apparent tension or precision of control. There was a stable grasp of objects of different shapes and sizes, which implied consistent coordination between the fingers. These findings indicate that the proposed system offers predictable and steady control behavior and has a simple and efficient mechanical and control architecture.

0.28

H-PAC Hand: Control-Oriented Modeling and Tendon-Elasticity Compensation for an Underactuated Robotic Hand

cs.RO ·2026-08-17 ·Teng Yan, Jiongxu Chen, Teng Wang, Yue Yu, Qixiang Hua +3 more
similarity 0.62
Abstract · 7 pages, 6 figures. Extended preprint

Underactuated tendon-driven hands offer compact actuation and passive compliance, but tendon elongation under restoring-spring loading introduces configuration-dependent joint deviations. This paper presents H-PAC, a modular 6-actuator, 15-DoF robotic hand with a control-oriented modeling and implementation framework. A sparse analytical actuator-joint model is derived from the tendon-routing geometry, and a mechanics-based compensation model is developed to account for tendon-elasticity-induced joint errors. The proposed method is implemented in a hierarchical architecture: a host computer performs workspace-constrained posture mapping and compensation, while an ESP32 generates synchronized commands for six position-controlled servos. The same control parameters and execution strategy are used across all tasks without task-specific retuning. Monotonic servo-sweep experiments show that the compensation substantially improves joint-angle prediction. The MAE of the index DIP joint decreases from 1.15 degrees to 0.18 degrees, and all nine evaluated joints achieve an MAE below 0.23 degrees. Representative postures and grasping configurations are further executed using the same control pipeline without external joint or force sensing in the control loop. The results demonstrate a practical approach to improving posture reproducibility in compact underactuated robotic end-effectors.