Abstract

Typical diagnosis of Parkinson's disease (PD) occurs only after significant dopaminergic loss, while resting-state EEG abnormalities like alpha slowing and reduced coherence occur earlier. While many published EEG-based PD detectors claim accuracy greater than 95%, many use epoch-level splits which leak subject identity. I introduce MambaPD, a bidirectional selective state space model for resting-state EEG-based PD detection, blending the channel mixing, patch tokenization and bidirectional Mamba encoder. It is compared with four baselines (TCN, BiLSTM with attention, EEGNet and a patch Transformer) in two public datasets (UNM, SanDiego) using subject-independent 5-fold cross-validation (checkpoints were selected on the held-out fold, so absolute estimates are optimistic). On UNM the accuracy is between 0.67 and 0.71, and MambaPD (0.714) is not statistically distinguishable from the Transformer (0.715), and TCN (0.708), with the highest sensitivity (0.82), while the lowest specificity (0.52). For the smaller SanDiego cohort, accuracy is in the range of 0.60 to 0.70, with the highest scores (0.703) from TCN and the lowest (0.601) from EEGNet, while MambaPD scores 0.631, with the lowest specificity (0.46) among the five models. The differences among the models on UNM are minor compared to the differences among folds. I report the whole pipeline, per-fold results, and the shortcomings of the protocol.

Comment
17 pages, 11 figures, 9 tables

Closest papers

Nearest neighbours by meaning across the whole index.

NOMAD-EEG: Native Omni-Montage Adaptive Diffusion

cs.LG eess.SP ·2026-10-26 ·Abdulkader Helwan, Khadidja Henni, Lina Abou-Abbas
similarity 0.60
Abstract · 37 pages and 7 figures

Purpose. Electroencephalography (EEG) montages, channel counts and recording lengths vary widely, but most EEG foundation models are bound to the channel set and input length they were trained on. We aimed to build a generative EEG foundation model independent of the number, identity and order of electrodes and of the input length. Methods. NOMAD-EEG is a 12.0 M-parameter diffusion model that alternates state-space layers along time, without patches, with attention across electrodes identified only by their 3D scalp position. It was pre-trained on 147 h of unlabelled EEG from a single corpus and evaluated with frozen linear probes on ten datasets with 1 to 64 electrodes against seven foundation models run under one protocol, and on two unseen populations. Results. Despite its small size (12.0 M parameters against 69 M for REVE) and single pre- training corpus, NOMAD-EEG outperformed all seven foundation models on EEGMMIDB mo- tor imagery (balanced accuracy 0.442), Siena seizure detection (macro F1 0.622) and Bonn seizure detection (AUROC 0.999), had the highest accuracy of the seven compared models on TUEP epilepsy diagnosis (0.640) and, after fine-tuning, the highest \k{appa} (0.635) and weighted F1 (0.814) on TUEV event classification. It was the best of five models on P300 detection in autism with an unseen eight-electrode montage (AUROC 0.718). With only 5 of 19 electrodes, its mean AUROC fell only from 0.942 to 0.891. Conclusion. Identifying electrodes by position and modelling time without patches let one small model, pre-trained on one corpus, outperform much larger EEG foundation models on seizure detection, epileptiform event classification, epilepsy diagnosis and motor imagery.

0.14

Evaluating the Generalization of Neuroimaging Foundation Models on African Brain MRI

cs.CV ·2026-09-21 ·Oluwatobi Iyanuoluwa Akinmuleya, Olatokun Shamsudeen Akano, Samuel Danquah Ankapong, Olamide Lawal, Toufiq Musah
published similarity 0.60
Abstract · MICCAI AFRICAI Workshop, Strasbourg, France, 2026, 10 Pages, 1 Figure, 2 Tables

Neuroimaging foundation models pretrained on large, predominantly western cohorts are increasingly proposed as general-purpose backbones for brain MRI analysis. Yet, their ability to generalize to underrepresented clinical populations remains largely untested. We evaluate four recent foundation models (BrainIAC, Neuro-JEPA, NeuroVFM, and Primus) on a three-way diagnostic classification task (Control, Dementia, Parkinson's disease) using a cohort of 88 subjects from a Nigerian clinical brain MRI dataset, across four modality configurations (T1w, T2w, T1w+T2w, FLAIR), and compare against an end-to-end trained ViT3D baseline. The frozen backbones collapse to majority-class predictions, while Neuro-JEPA on FLAIR shows modest but still limited discrimination. In contrast, the end-to-end trained ViT3D achieves higher accuracy and MCC on every task (up to 53.4% accuracy, MCC=0.27) and is the only model with non-trivial recall. Our findings suggest that these frozen neuroimaging foundation models are insufficient for fine-grained diagnostic classification in small, non-western clinical cohorts, motivating parameter-efficient adaptation and broader multi-site external validation for equitable deployment in global health settings.

0.29

Aggregate, Don't Adapt: Subject-Level Posterior Aggregation and Transductive Calibration for Cross-Site Parkinsonian Gait Severity

cs.CV cs.AI ·2026-08-20 ·Junlong Shen
benchmark similarity 0.59
Abstract

We describe the winning entry to the MoCha 2026 Benchmark and Challenge on Parkinsonian Gait, which predicts MDS-UPDRS gait severity from canonicalized SMPL motion recorded at clinical sites unseen during training. The system reaches 0.6945 macro-F1 on the hidden test and ranked first of 58 entries, ahead of the runner-up at 0.5807 and the organizers' baseline at 0.4289, on a frozen public motion encoder with a single $4\times512$ linear layer. Nearly all of the margin comes from three stages usually treated as bookkeeping: reproducing the reference benchmark's exact head recipe, averaging per-walk posteriors within the subject grouping the organizers ship, and a label-free transductive calibration of the feature mean and the decision operating point. Fine-tuning the encoder lost in four distinct forms, and ten alternative encoders were worse. Every ablation number is a paid read on the hidden test, because our own leave-two-cohort-out cross-validation proved anti-correlated with the deciding score over eleven configurations. We give the negative record in full, and identify our largest gain, subject-level aggregation, as the binding ceiling on this benchmark.

0.35

Separating Diagnosis from Disease Representation: Dual-View EEG Learning with Neural-Dynamics-Guided Deformation

cs.AI ·2026-09-26 ·Jiaying Wang, Shouqian Shi, Yutong Chen, Xu Yang, Jie Chen +3 more
similarity 0.58
Abstract

Electroencephalography (EEG)-based closed-loop neuromodulation calls for a subject-specific structured state, as opposed to a single disease probability, specifying which brain regions are deviant, at which frequencies, and at which lags. Sensor-space models keep the strongest diagnostic evidence without anatomy, source-space models give anatomy at a loss of predictive signal, and post-hoc attributions stay outside the prediction. We separate the two instead of forcing them into one representation, and propose DMD-EEG (Dual-view Multiscale Deformation for EEG), which keeps a fixed scalp spectral expert for diagnosis and models the source-space disease-related representation as a low-rank, sparse, iterative deformation of a healthy neural-dynamics prior in a $46$-region-of-interest (ROI) $\times$ $5$-frequency $\times$ $4$-lag (autocorrelation-timescale) space. The two experts meet only at a fixed decision level, so the source state is architecturally separate from the scalp expert. Across major depressive disorder (MDD), first-episode psychosis (FEP), and Parkinson's disease (PD), decision-level fusion matches the strongest single expert on MDD and FEP and exceeds the source branch on PD. On FEP the source expert is the strongest branch, the task where the deformation contributes most. The source state is an explicit ROI-frequency-lag attribution defined in a shared source coordinate system across montages, which we treat as an anatomically-coordinated predictive representation whose coordinates are directly readable and hypothesis-generating. The highest-saliency coordinates align with established disease circuitry (fronto-limbic-temporal regions in MDD, motor-cortex beta in PD), and the MDD state transfers by rank to an unseen cohort recorded with a different montage.

0.27

Leveraging a Foundation Model for the EEG-Based Diagnosis of Alzheimer's Disease

cs.LG q-bio.NC ·2026-08-27 ·Maggie Lin, Chung-Lin Hou, Tzyy-Ping Jung
published similarity 0.58
Abstract · 7 pages, 9 figures, 1 table. Accepted and presented at the 48th Annual International Conference of the IEEE Engineering in Medicine and Biol…

Biological heterogeneity in Alzheimer's Disease (AD) poses a critical diagnostic challenge, particularly for traditional linear methods that fail to capture non-linear neural dynamics. To address this, we propose a diagnostic framework utilizing the Large Brain Model (LaBraM), pretrained on over 2,500 hours of EEG data. By integrating these high-dimensional latent embeddings with a non-linear Random Forest classifier, our approach effectively isolates robust disease markers. Under a rigorous subject-independent 5-fold cross-validation protocol, the method achieves an ROC-AUC of 89.36% +/- 3.49%, PR AUC of 81.45% +/- 4.43%, and Balanced Accuracy of 82.44% +/- 4.34% in distinguishing dementia patients from healthy controls. Notably, this performance uses only 8-second EEG segments, surpassing traditional spectral baselines, including band-power and parameterized oscillatory features (FOOOF). Post-hoc occlusion analysis confirms the model captures clinically validated biomarkers, specifically occipital-frontal Alpha and Theta rhythm degradation. Additional neurophysiological alignment analysis demonstrated that higher LaBraM-predicted dementia probability significantly correlated with worse cognitive performance, greater clinical severity, increased theta and alpha relative power, and higher aperiodic exponent. These findings demonstrate that deep latent representations extract clinically relevant signatures from noisy signals, enabling precise, rapid, and data-efficient diagnosis.

0.30

Lightweight Semantic EEG Foundation Model for Frozen Cross-Disorder Transfer

cs.LG eess.SPq-bio.NC ·2026-10-04 ·Rita Huan-Ting Peng, Nhat Bui
similarity 0.58
Abstract

Large-scale EEG foundation models have demonstrated promising transferability across neurological disorders, but often require millions of parameters and substantial computational resources. In this paper, we present the Universal Semantic EEG Foundation Model (USE-FM), a lightweight EEG foundation model that learns transferable neural representations through self-supervised signal reconstruction on the Temple University Hospital EEG Corpus (TUEG). After pretraining, the encoder is frozen and evaluated on two clinically distinct downstream tasks, abnormal EEG detection (TUAB) and epileptic seizure recognition (TUEP), using a unified frozen-transfer protocol against recent EEG foundation models, including LUNA-Base and CBraMod. With only 1.46 million parameters, approximately one-fifth the size of existing models, USE-FM achieves competitive overall performance, including strong sensitivity and F1-score on TUEP (SEN $75.00 \pm 14.14$, F1 $70.37 \pm 4.01$), while maintaining competitive performance on TUAB (AUC $85.24 \pm 5.61$). Beyond downstream classification, latent representation analysis using $k$-means clustering together with PCA and t-SNE demonstrates that USE-FM learns organized semantic EEG representations comparable to substantially larger foundation models. These results suggest that large-scale self-supervised pretraining enables lightweight architectures to learn transferable semantic EEG representations, providing a computationally efficient foundation for cross-disorder analysis and future clinical decision support in neurological disorders.

0.06

Lightweight Adaptation of EEG Foundation Models for Stroke Motor Imagery Decoding: Domain Shift and Subject-Level Robustness

cs.CE cs.LG ·2026-08-31 ·Anh T. Nguyen, Zihua Sun, Michelle J. Johnson
benchmark similarity 0.57
Abstract

Motor imagery (MI) electroencephalography (EEG) decoding could support post-stroke rehabilitation, but models developed on healthy cohorts may not transfer reliably to pathological EEG. We evaluated whether Low-Rank Adaptation (LoRA) can efficiently adapt three pretrained EEG foundation models (i.e., LaBraM-base, REVE-base, and REVE-large) for binary left- versus right-hand MI decoding. Frozen-backbone head-only baselines and LoRA adaptation were evaluated using subject-wise five-fold cross-validation on the PhysioNet EEG Motor Movement/Imagery Dataset and a binary subset of the UET175 dataset comprising 30 stroke participants. On EEGMMIDB, LoRA increased accuracy to 0.822 for LaBraM-base and 0.957 for REVE-base. On UET175, all head-only models performed near chance. With LoRA, LaBraM-base remained near chance (0.499$\pm$0.009), whereas REVE-base reached 0.847$\pm$0.194 and outperformed REVE-large (0.806$\pm$0.178), indicating that increased model capacity alone did not improve stroke-domain adaptation. The strongest stroke configuration, REVE-base LoRA, was further evaluated using within-cohort leave-one-subject-out cross-validation (LOOCV), showing 0.952 mean accuracy, but subject-wise accuracy ranged from 0.586 to 1.000, revealing a small low-performing tail. Zero-shot transfer from EEGMMIDB to UET175 remained near chance (0.464$\pm$0.072). These findings show that healthy-benchmark performance does not ensure transfer to stroke EEG. Translation of EEG foundation models to pseudo-online or real-time rehabilitation BCIs should therefore include target-domain adaptation and subject-level assessment of temporal informativeness, spatial sensitivity, and physiological discriminability.

0.28

Exploiting Speech LLM Representations for Multilingual and Cross-Lingual Parkinson's Disease Detection

cs.SD eess.AS ·2026-09-13 ·Sarthak Giri, Zi Haur Pang, Tatsuya Kawahara
hot direction similarity 0.57
Abstract · Accepted at IEEE Spoken Language Technology Workshop (SLT) 2026

Speech Large Language Models (Speech LLMs) have shown strong performance across diverse tasks, yet their utility for pathological speech analysis remains underexplored. In this work, we investigate the effectiveness of internal representations from encoder and decoder components of Speech LLMs for Parkinson's Disease (PD) detection across multilingual and cross-lingual settings. Our findings reveal that encoder representations consistently outperform their decoder counterparts in most models and settings and that pathological cues may be progressively attenuated as audio representations are projected into the language model space. We further show that generative outputs are less reliable for clinical tasks compared to internal representations. To leverage information spread across multiple layers, we propose a Squeeze-and-Excitation (SE)-based dynamic layer aggregation framework, which surpasses best-layer selection in multiple experiments, suggesting that PD-relevant acoustic cues are distributed across transformer layers rather than concentrated in one.

0.27