CS Paper Radar

Selective Surgical Action-Center Localization:Retaining Localization Gains through Supervised Scoring

Yanchong Xue, Wanting Zhang, Lingtao Yu, Guochao Zhang

cs.CV ·submitted 2026-11-08 04:58 UTC · v1
hot direction

Abstract

Surgical action-center localization requires both an accurate reference point and a decision about whether to report it. When frames with and without a reportable center are mixed, the benefit of improved localization depends on which correct candidates survive selection. We present a selective localization pipeline combining heatmap and coordinate supervision with a logistic-regression scorer. The scorer learns to identify predictions with a reportable center and a localization error within a specified tolerance. The internal evaluation uses 5,000 frames from 50 surgical sources, five source-grouped folds and two random seeds. Matched locator and scoring comparisons track correct candidates and their rejection. At an 80% acceptance quota per source and a tolerance of 0.10 times the image diagonal, our method retains 46.08 correct outputs per 100 inputs. The baseline locator with the same scoring approach retains 44.20. The gain is 1.88 (descriptive 95% source-paired bootstrap interval, 0.94 to 2.79). Under entropy-based selection, increased rejection of correct predictions offsets the higher supply of correct predictions on average. For the coordinate-supervised locator, supervised scoring reduces these rejections from 6.15 to 2.99 per 100 inputs. Evaluating retained correct outputs reveals whether a selection rule preserves or erodes an improvement in localization.

Closest papers

Nearest neighbours by meaning across the whole index.

From Presence Labels to Bounding Boxes: Can Multimodal Large Language Models Scale Surgical Instrument Localization?

cs.CV ·2026-10-25 ·Mohamed Hamdy, Muraam Abdel-Ghani, Fatmaelzahraa Ahmed, Sifna Nasar, Mariam Ahmed +3 more
similarity 0.69
Abstract

Spatial localization of surgical instruments through bounding-box annotations is a foundational component of surgical scene understanding, supporting detection, tracking, interaction analysis, and grounded vision-language applications. Yet existing annotations often cover selected frames, video subsets, or dataset variants rather than complete procedures. Manual extension is time-consuming and expert-dependent. Additionally, weakly supervised and detector-based pseudo-labels require task-specific training and may be imprecise. In this study, we design a scalable MLLM-based annotation framework that converts surgical frames and existing instrument-presence labels into accurate bounding boxes, and systematically analyze its reliability, cost, and design sensitivity. We instantiate the framework using six MLLMs and a multi-call configuration on laparoscopic cholecystectomy in Cholec80. Using a carefully designed stratification scheme, two annotators independently label 1,000 frames, and an expert surgeon reviews one annotation set to establish the reference. Results show that instrument-set F1 ranges from 88.2 to 92.7,whereas mIoU ranges from 0.180 to 0.735, showing that comparable recognition can conceal large localization differences. A structured multi-stage annotation pipeline achieves 0.784 mIoU, compared with 0.735 for the best single-call baseline and 0.814 human-human agreement. Using the best accuracy pipeline, we create and publicly release SurgBox, a spatial extension of Cholec80 comprising 285,977 bounding boxes across all 184,498 annotated frames from the 80 videos. The annotations and human references are made available on GitHub

0.23

STEP: Surgical Point Tracking from Sparse Endpoints and Pseudo-trajectories

cs.CV ·2026-10-22 ·Bing Fan, Anwesa Choudhuri, Zhongpai Gao, Meng Zheng, Benjamin Planche +3 more
similarity 0.64
Abstract

Surgical point tracking requires persistent correspondence through tissue deformation and occlusion, yet dense trajectory annotations are costly to obtain. We present STEP, a two-stage framework that learns from surgical video and sparse physical endpoints. First, a frozen offline teacher generates candidate trajectories, and temporal reversibility and stereo consistency select dense supervision for a causal student. Second, a robust physical endpoint loss anchors terminal correspondence, while a round-trip loss constrains temporal consistency. A gradient-free prefix exposes training to accumulated drift, while a final differentiable window bounds activation memory. The trained tracker processes a single RGB stream with fixed weights. In STIR-to-VL-SurgPT transfer, temporal-stereo union selection reduces endpoint error by 7.0% relative to unfiltered trajectories. On a post-hoc diagnostic of 29 VL-SurgPT clips excluded from the endpoint-training manifest, STEP reduces endpoint error from 31.52 to 16.80 pixels relative to dense-label fine-tuning. These results support combining curated trajectories with physical observations to train surgical point trackers.

0.17

Instance-preserving graded semantic reporting for surgical action triplets

cs.CV ·2026-11-09 ·Yanchong Xue, Wanting Zhang, Lingtao Yu, Guochao Zhang
similarity 0.64
Abstract

Complete-or-reject reporting of surgical action triplets can discard a correctly identified instrument and action when the target is uncertain. We introduce instance-preserving graded semantic reporting, which separates instance selection from the choice of semantic detail. Each selected instance retains its predicted mask and labels while hierarchical correctness scores guide instrument (I), instrument-verb (IV), or complete instrument-verb-target (IVT) reporting. The utility-increment rule DELTA weighs the expected gain from finer reporting against its error cost. We compare three decision rules on 5,641 test frames from eight surgical videos using fixed predictions and scores. At the 10% development calibration target, DELTA retains correct partial reports for 80.0% of candidates rejected by a matched complete-or-reject baseline (5,329/6,662). Adding IV increases source-normalized weighted correct-report yield by 19.13 to 23.13 per 100 frames across all three rules relative to separately recalibrated I/IVT controls. Weighted reporting risk changes by -0.77 to +1.01 percentage points, with complete correct-triplet counts unchanged or reduced. Graded reporting makes partial surgical predictions available as localized descriptions, with an explicit trade-off between report utility and completeness.

0.17

Surgical Video Generation From Diffusion to World Models: A Survey

cs.CV ·2026-08-26 ·Fuxiang Huang, Chenxu Zhang, Liang Han, Lei Zhang
publishedsurvey similarity 0.63
Abstract · 4 pages, 1 figures, 3 tables. Accepted for oral presentation at the 2026 3rd International Conference on Intelligent Perception and Pattern …

Surgical video data provides the primary training resource for models of intraoperative perception, surgical workflow understanding, and robotic decision-making. However, clinical data acquisition remains constrained by privacy, cost, and class imbalance. Surgical video generation has emerged as a transformative approach to addressing data scarcity and as a foundation for surgical simulation, training, and robotic policy learning. The field has developed rapidly without a clear conceptual framework. This survey organizes the 2024-2026 literature into three categories: unconditional generation, conditional generation, and world modeling generation, revealing a fundamental shift in how the task is defined from synthesizing visually plausible frames to modeling the causal dynamics of surgical scenes. We examine the persistent gap between pixel-level fidelity and clinical plausibility, and identify generalization, physical realism, controllability, and interpretability as bottlenecks. We further summarize experimental results of representative methods on public datasets to provide a quantitative reference for the field. This survey provides a structured overview of the current state and open challenges, offering a reference for researchers working at the intersection of intelligent perception, multi-modal fusion, generative AI, and surgical data science.

0.18

SurgTransfer: Multi-Step Latent Action Modeling for Action Transfer in Surgical World Model

cs.CV cs.AIcs.LG ·2026-11-03 ·Saurabh Koju, Love Panta, Deepak Thapa, Rudra P. K. Poudel, Prajwal Ghimire +4 more
code/data similarity 0.63
Abstract

Surgical world models have the potential to provide intra-operative guidance, accelerate risk-free training and facilitate transfer of expert surgical maneuvers. However, the use of world models for transferring surgical expertise has been largely unexplored. Moreover, recent approaches in this domain have mainly relied on ground truth kinematics actions or expert annotations for specific tasks, limiting their applicability beyond the narrow range of tasks with ground-truth annotations. In contrast, existing works in the natural domain have shown promising results in learning latent actions solely from unlabeled videos and transferring the learned actions across contexts. We observe that this paradigm is short-sighted for the surgical domain, failing to capture the hierarchical and goal-directed structure of surgical procedures. Thus, we propose a novel multi-step action learning framework to learn context-invariant latent actions that are easily transferable across various surgical contexts. We perform extensive experiments on the publicly available datasets, SurgToolLoc-2022 and PitVis-2023, verifying our approach with both quantitative metrics and qualitative evaluation by surgical experts. We have published our code and the implementation details at https://github.com/bhattarailab/Surgical-Vision-World-Model.

0.26

Uni-Loc: Weakly Supervised 3D CT Pathology Localization via Spatially Grounded Vision-Language Classification

cs.CV ·2026-11-09 ·Hao-Chih Lee, Zahi A. Fayad, Xueyan Mei
similarity 0.63
Abstract

Accurate localization of abnormalities in three-dimensional (3D) CT scans is essential for linking automated predictions with clinically relevant pathological findings. We propose Uni-Loc, a vision-language framework that unifies pathology classification and 3D localization using scan-level supervision. Uni-Loc derives both predictions and localization maps from spatial similarities between pathology-conditioned queries and image features. A token-to-voxel upsampling module enables high-resolution localization, while gradient-guided thresholding identifies pathology regions without additional learned parameters. Evaluated on five localization tasks comprising 355 annotated CT scans, Uni-Loc achieves macro-averaged voxel-level AUROC/AUPR of 96.1\%/34.5\%, outperforming relevance propagation (80.7%/13.9%) and gradient saliency (88.7%/8.1%). Uni-Loc also achieves classification AUROC of 88.39% on CT-RATE and 78.03% on RAD-ChestCT, improving over a matched baseline. These results demonstrate effective 3D pathology localization without requiring pathology-specific voxel-level supervision.

0.12

Video Based Assessment of Surgical Skills Using Frozen Pretrained Video Foundation Models

eess.IV ·2026-09-17 ·Sangrock Lee, FNU Rahul, Suvranu De
publishedbenchmark similarity 0.62
Abstract · Accepted for publication in npj Digital Medicine

Automated video-based surgical skill assessment has advanced rapidly, yet rigorous evaluation of continuous standardized score prediction under participant-level generalization to unseen trainees remains limited. We introduce VBA-Net+, a video-only framework for Fundamentals of Laparoscopic Surgery (FLS) score regression and pass-fail classification using pretrained video foundation models as frozen feature extractors. We evaluate two FLS datasets, suturing and pattern cutting, using VideoPrism, V-JEPA2, and VideoMAE v2, with a frame-level SimCLR baseline. A lightweight fully convolutional head is trained on embeddings offline and evaluated using participant-level leave-one-user-out (LOUO) cross-validation within the standardized assessment protocol. For continuous score prediction, the best representation achieves $R^2$=0.6367 for suturing and 0.9261 for pattern cutting. For pass-fail classification at official FLS thresholds, area under the receiver operating characteristic curve (AUC) reaches 0.9073 and 0.9906, respectively. Frozen video-encoder pipelines generally outperformed the frame-level SimCLR pipeline, particularly for suturing, providing a benchmark for video-only FLS assessment.

0.24

SurgVIL: Scaling Surgical Robot Imitation Learning with Open-source Surgical Videos

cs.RO ·2026-08-17 ·Xinhao Chen, JuoTung Chen, Nigel Nelson, Antony Goldenberg, Jesse Haworth +2 more
code/data similarity 0.61
Abstract

Learning-based surgical robot autonomy requires large-scale demonstrations with synchronized videos and robot actions, but such data are exceedingly rare in clinical or realistic tissue settings because robot kinematics are typically inaccessible outside controlled research systems. In contrast, phantom data collected on research platforms provide accurate action labels but lack the visual diversity of real tissue. We propose SurgVIL, a framework for scaling surgical robot imitation learning using open-source surgical videos. SurgVIL combines kinematically labeled phantom robot demonstrations with surgical videos from open-source datasets and online sources for policy learning. Since these videos lack robot motion labels, we estimate approximate kinematics as weak supervision. We evaluate SurgVIL on two da Vinci robot tasks: needle pick-up and cholecystectomy cutting. Across ACT, $π_0$, and GR00T-H backbones, adding surgical videos substantially improves generalization to real-tissue and out-of-distribution settings, suggesting a scalable path from phantom training toward generalizable surgical robot policies.

0.48