CS Paper Radar

Ninety-Six Ways to Measure a Scribe: Fragmented Evaluation of Ambient Scribes in Healthcare

Amama Mahmood, Shiye Cao, Laura Fleig, Junan Jiang, Theodore Jensen, Yee-Yin Choong, Kristen Greene, Chien-Ming Huang

cs.HC cs.AI ·submitted 2026-11-10 16:26 UTC · v2
hot direction

Abstract

Ambient artificial intelligence (AI) scribes have moved rapidly from experimental pilots to enterprise-wide deployment across health systems, promising reduced documentation burden and improved clinician experience. While research evaluating these tools has expanded quickly, there are no agreed-upon protocols or standardized metrics for assessing their performance, making it difficult to compare findings or cumulatively synthesize evidence across studies. Across 54 recent evaluation studies, we identify ten evaluation dimensions and 40 distinct metrics, operationalized in 96 different ways-35 of them (36%) used by only a single study. Assessment is dominated by documentation efficiency and time, measured in 44 of 54 studies. The other dimensions appear at broadly similar rates (16-24 studies each), and safety and clinical outcome least consistently of all. Ripple effects on the broader care system, such as impact on patients' care outcomes, redistribution of work, changes in billing and coding intensity, and downstream use of notes by other clinicians are rarely assessed. Moreover, the metrics used rely heavily on self-report and are fragmented and inconsistently operationalized, which limits comparability and hinders synthesis across studies. As an effort to support more rigorous and cumulative evaluation, in this paper we review the study designs, data sources, and metrics commonly used to evaluate ambient AI scribes in healthcare settings, discuss the limitations of current evaluation practice, and argue for a more holistic approach grounded in a standardized, multi-dimensional set of metrics.

Closest papers

Nearest neighbours by meaning across the whole index.

One note in three: a verified census of three deployed AI scribes, and the instrument that counted it

cs.CL cs.AIcs.CY ·2026-08-31 ·Sebastian Fox, Luke Markham, Ryan Lail, Michael Karotsieris
code/data similarity 0.72
Abstract · 47 pages, 3 figures. Dataset: https://huggingface.co/datasets/ComposoAI/OmissionBench . Code: https://github.com/composo-ai/omission-bench .…

Ambient AI scribes draft clinical notes under the reassurance that a clinician signs every note. We audited three commercial AI scribes on the same 142 consultations: 565 notes from recorded UK primary-care and US ambulatory encounters plus authored scenarios. Twelve discovery passes proposed 13,678 candidate errors; the 5,898 clearing an importance filter went to an adversarial panel of two models from different families, each told to refute what it could, and 618 survived. One note in three (31.3% [27.0, 35.6]) carries a verified failure, concentrated in allergy and medication information, invented patient identity, and history written up as examination on telephone consultations that can contain none. No product was given a patient record; setting aside the two classes a record would have prefilled, invented identity and dates, the rate is 24.8% [20.8, 29.0]. One failure mode did not fit our scheme, drawn from published scribe-error taxonomies: a treatment the clinician retracts, recorded as delivered care. Two clinicians adjudicated blind, disjoint samples: a physician author upheld 20 of 21 findings (95.2% [77.3, 99.2]) and an independent clinician, not an author, 12 of 12 ([75.8, 100]); both judged every sampled refusal genuine. A failure rate depends on the instrument as much as the scribes. With model, evidence and settings fixed, the review instruction alone moves the share of candidates verified from 9.3% to 79.0%, and the reviewing family moves it too: alone at that instruction the gentler flags 54.8% of notes against 27.8%. Between 28% and 97% of sampled notes carry a failure depending on the standard. Published audits disagree among themselves by a margin instrument differences alone can produce: omission is 54-86% of their errors against our 23.1%. We release all 618 findings with transcript-side evidence, every prompt and model version, and the re-runnable pipeline.

0.79

Symphony for Text Generation: Benchmarking Clinical Note Generation

cs.LG cs.AIcs.CL ·2026-10-06 ·Daniel Varab, Victor Petrén Bach Hansen, Asbjørn W. Helge, Kevin Pelgrims, Mathias Baltzersen +6 more
benchmarkdataset similarity 0.68
Abstract

Ambient documentation systems are rapidly gaining adoption, yet their impact on clinical note quality remains poorly characterized. We introduce MedConv, a multilingual dataset of 300 clinical encounters in English, Danish, and German, and use it alongside the Ambient Clinical Intelligence benchmark (ACI-BENCH) to compare Corti, a clinical AI platform, with two leading, accessible ambient scribe software applications built on general-purpose AI. We present a controlled clinical evaluation framework that combines entailment metrics with LLM-judged pairwise comparisons across eight dimensions adopted from PDSQI-9. Results show that Corti's API-based text-generation infrastructure is on par with or outperforms leading commercial scribes. We further show that Corti's configurable API provides the flexibility necessary to fine-tune quality dimensions for specific documentation use cases. We present the evaluation methodology and release a dataset to support future reproducible comparison of ambient documentation systems.

0.06

Assessment of Non-Institutional AI Tool Usage Among Clinicians

cs.AI physics.soc-ph ·2026-09-08 ·Sarah Pungitore, Jarrod Mosier
survey similarity 0.67
Abstract

Generative artificial intelligence (AI) tools are increasingly accessible and have the potential to improve efficiency across clinical workflows. However, clinicians may also use non-institutional AI tools that are not provided, managed, or governed by their healthcare institutions, creating potential concerns related to privacy, security, accuracy, and clinician-AI interaction. Little is known about how clinicians currently use these tools for work-related tasks. We conducted a descriptive survey of clinicians recruited from the University of Arizona College of Medicine-Tucson and Banner University Medical Center-Tucson between May 20 and June 26, 2026. Participants reported their use of AI tool categories and the frequency with which they used AI for specific tasks across five workload categories: administrative work, clinical work, research, studying/continued education, and teaching. Forty-four respondents completed the survey. Forty-three respondents reported using AI for at least one work-related task during the preceding 6 months. Conversational AI and clinical decision support/diagnostic AI were the most used tool categories, each reported by 28 respondents. Administrative and clinical tasks demonstrated the most frequent use. AI was also used for higher-risk activities, including diagnostic assistance and clinical decision support. Non-institutional AI use was common among surveyed clinicians and extended across a broad range of work-related activities, including tasks with potential implications for clinical reasoning and patient care. Further research is needed to characterize how clinicians use these tools, how they evaluate AI-generated outputs, and how AI can be safely and effectively integrated into clinical workflows.

0.34

KnowBench: Effort Reduction as a Unified, Deployment-Grounded Benchmark for Clinical AI

cs.AI ·2026-09-14 ·Jocelyn Kang, Caroline Zhang
benchmark similarity 0.64
Abstract · 7 pages, 1 table. Contact: jocelyn@knowtex.ai

Clinical AI systems are evaluated with instruments built for research settings (reference-based similarity metrics and expert rubric panels) that measure resemblance to an artifact rather than reduction of a burden. We introduce KnowBench, pioneered by Knowtex, whose unifying metric is Effort Reduction (ER): the proportion of system-generated clinical work product accepted by the responsible clinician under expert and safety review. ER is defined once and instantiated per task across the administrative workload clinical AI automates: visit notes, diagnosis and billing codes, orders, EHR chart summarization, patient after-visit summaries, and clinical decision support. In every instantiation the construction is identical: the clinician's review-and-attestation event is the ground truth, every accepted unit is work the system completed, and every correction is residual effort returned to the clinician. The primary contribution of this paper is the benchmark itself: the metric, its degenerate cases, and a reporting protocol under which ER claims are auditable and cross-system comparable. Alongside it we report an initial headline measurement from the documentation instantiation: over one million signed encounters across a production window exceeding six months and thirteen medical specialties, Knowtex's proprietary fine-tuned clinical foundation models operating inside a closed feedback architecture achieve an aggregate ER of 97.99%, with per-specialty aggregates spanning 96.8-98.9%. This release reports the protocol's checklist partially, and states which companion statistics are withheld; the benchmark is offered so that this figure, and every figure reported after it, can be held to the same standard.

0.19

CareGraph: An Auditable Hybrid AI Framework for Evidence-Grounded Personalized Longitudinal Health Intelligence

cs.AI cs.IRcs.MA ·2026-08-25 ·Pratik Ghawate, Tanvi Patil
benchmarkcode/data similarity 0.64
Abstract · 21 pages, 7 figures, Code and data: https://github.com/PratikGhawate/ai-personalized-health-intelligence

Artificial intelligence is transforming personalized healthcare, yet fragmented clinical, self reported, and wearable evidence remains difficult to interpret and trace. We present CareGraph, an auditable hybrid AI framework that converts heterogeneous records into prioritized trends, missing context indicators, bounded next steps, discussion questions, and provenance linked explanations. CareGraph organizes evidence without diagnosing, predicting outcomes, selecting treatment, or making autonomous clinical decisions. Its pipeline covers deterministic analysis, context detection, graph construction, constrained language model synthesis, evidence validation, safety controls, and release gating. Tests used synthetic cohorts of 400 patients each for development, validation, and holdout. On holdout data, a frozen ordinary least squares trend rule with a sufficiency gate achieved 0.827 accuracy, 0.837 macro F1 with a 95 percent confidence interval of 0.819 to 0.854, and 0.974 insufficient data F1. Missing context detection achieved 0.815 strict micro F1 versus 0.318 for the legacy detector. On an authored holdout benchmark, safety ruleset version 1.2 achieved 1.000 precision, 0.950 recall, and 0.974 F1. An audit requiring graph retrieval across 80 patients yielded 79 syntheses and 78 presentations without fallback; one output was blocked and one failed closed because of an invalid evidence key. Against monolithic GPT 5.6 on 56 matched patients, CareGraph was faster at 40.15 versus 49.62 seconds, shorter at 661 versus 1,163 words, and showed better exploratory lexical alignment with longitudinal targets; the baseline used fewer tokens and cited more raw evidence. Graph auditing verified provenance and deterministic retrieval; incremental graph effects on generation require paired evaluation. CareGraph offers a safety bounded foundation for intelligent personalized health systems.

0.42

When Clinical Judgment Becomes a Predictive Shortcut: Two Questions Clinical AI Must Answer Before Deployment

cs.AI ·2026-09-22 ·Jing Yang, Long R. Jiao, Zongjiu Zhang, Xiujun Cai
similarity 0.64
Abstract · 27 pages, 1 figure, 3 tables, 1 box; includes Multimedia Appendix 1

Clinical AI can predict outcomes using information generated by existing clinical judgment. Such performance alone cannot establish usefulness before recognition or across care processes. We propose evidence requirements matched to intended use and information conditions, with additional state-reference and proxy-relative timing tests for stronger recognition claims. This framework helps hospitals assess whether the conditions supporting performance hold when assistance is most needed. These questions remain outside current evaluation practice leakage checks, overall predictive performance, and external validation do not address them; the framework makes them explicit and specifies the direct evidence required to answer them.

0.19

Verify, Offload, Extend & Recommend: Selective Complementarity in AI Support for Physical Activity Planning with Longitudinal Patient Data

cs.HC ·2026-09-16 ·Pavithren V S Pakianathan, Rania Islambouli, Diogo Branco, Gil Batista Rosa, Rita Pinto +3 more
similarity 0.63
Abstract

Self-tracking technologies create longitudinal patient-generated health data, yet integrating these data into clinical decision-making can increase information-processing demands. Generative AI may support sensemaking, but its value depends on clinical context and expertise. We investigate AI augmentation of a clinical decision support system for physical-activity planning in cardiovascular disease. In a counterbalanced within-subjects study, 26 exercise physiologists developed plans for four real cardiovascular cases with and without AI support, followed by evaluation of an AI exercise-plan generator. AI did not significantly improve workload, usability, confidence, or plan quality overall; however, its effect on plan quality increased as visualization literacy decreased and its effect on workload increased as visualisation literacy increased. Interviews and 152 chatbot queries revealed three recurring uses: verifying, offloading, extend and generate. Our findings position AI support as a selective complement to professional expertise while highlighting validation challenges when clinicians seek support precisely where their own knowledge is limited.

0.29

Objectify, Don't Delete: Complaint-Derived Evaluation of Ambient Clinical Notes

cs.AI cs.CL ·2026-11-14 ·Nikita Gupta, Narayanan Unny Edakunni, Vikram Okaly, Suranjana Datta, Navya Penubadi +2 more
publishedbenchmarkpositioncode/datahot direction similarity 0.63
Abstract · Accepted at the Third Workshop on GenAI for Health (GenAI4Health), NeurIPS 2026 (non-archival). 16 pages, 5 figures, 11 tables. Code and dat…

Evaluating the quality of AI-generated clinical notes is hard: standard metrics like ROUGE measure lexical similarity to reference notes, while expert checklists encode what committees believe matters. Neither captures what clinicians actually complain about. Recent work has shown that evaluation criteria can be mined from user feedback and filtered to criteria that LLM judges can reliably enforce. We argue that this is where much of the value is lost. The criteria that fail enforceability are disproportionately the ones clinicians raise most often, because high-frequency complaints are stated as several questions glued together. No yes/no judgment can grade such composites as posed. We introduce an objectification step that rewrites such criteria into sets of scoped, determinate decisions. We demonstrate the approach through an evaluation pipeline that mines criteria from complaints, objectifies them, and deploys LLM judges against both planted defects and production notes. Across eleven defects planted into ACI-bench reference notes, objectified judges localize violations with median recall of 0.95, while reference metrics change by at most 0.037. Given the complaint as one broad question, the same judges still find every planted defect, but they also flag 70% of the unperturbed reference notes; one section-pair question per call raises Youden's J from 0.30 to 0.72 (by 0.19 to 0.26 with prompt effort matched). We release ACI-Defect, a perturbation benchmark; clinician-reviewed instance-level labels showing quality gaps in the ACI-bench gold standard (32 of 40 notes contain hallucinations; 40 of 40 omit discussed facts); and grounding-judge verdicts. On 1,446 production notes, mean instance-rate burden falls at every clinician-rating step (rho=-0.15), a small association. Defect counts have to be kept per span rather than collapsed into one pass/fail bit per note.

0.47