CS Paper Radar

One note in three: a verified census of three deployed AI scribes, and the instrument that counted it

Sebastian Fox, Luke Markham, Ryan Lail, Michael Karotsieris

cs.CL cs.AIcs.CY ·submitted 2026-08-31 16:00 UTC · v1
code/data

Abstract

Ambient AI scribes draft clinical notes under the reassurance that a clinician signs every note. We audited three commercial AI scribes on the same 142 consultations: 565 notes from recorded UK primary-care and US ambulatory encounters plus authored scenarios. Twelve discovery passes proposed 13,678 candidate errors; the 5,898 clearing an importance filter went to an adversarial panel of two models from different families, each told to refute what it could, and 618 survived. One note in three (31.3% [27.0, 35.6]) carries a verified failure, concentrated in allergy and medication information, invented patient identity, and history written up as examination on telephone consultations that can contain none. No product was given a patient record; setting aside the two classes a record would have prefilled, invented identity and dates, the rate is 24.8% [20.8, 29.0]. One failure mode did not fit our scheme, drawn from published scribe-error taxonomies: a treatment the clinician retracts, recorded as delivered care. Two clinicians adjudicated blind, disjoint samples: a physician author upheld 20 of 21 findings (95.2% [77.3, 99.2]) and an independent clinician, not an author, 12 of 12 ([75.8, 100]); both judged every sampled refusal genuine. A failure rate depends on the instrument as much as the scribes. With model, evidence and settings fixed, the review instruction alone moves the share of candidates verified from 9.3% to 79.0%, and the reviewing family moves it too: alone at that instruction the gentler flags 54.8% of notes against 27.8%. Between 28% and 97% of sampled notes carry a failure depending on the standard. Published audits disagree among themselves by a margin instrument differences alone can produce: omission is 54-86% of their errors against our 23.1%. We release all 618 findings with transcript-side evidence, every prompt and model version, and the re-runnable pipeline.

Comment
47 pages, 3 figures. Dataset: https://huggingface.co/datasets/ComposoAI/OmissionBench . Code: https://github.com/composo-ai/omission-bench . Companion paper: "LLM Judges Verify Presence, Not Absence: Omission Blindness in AI Clinical Notes and What Recovers It"

Closest papers

Nearest neighbours by meaning across the whole index.

Ninety-Six Ways to Measure a Scribe: Fragmented Evaluation of Ambient Scribes in Healthcare

cs.HC cs.AI ·2026-11-10 ·Amama Mahmood, Shiye Cao, Laura Fleig, Junan Jiang, Theodore Jensen +3 more
hot direction similarity 0.72
Abstract

Ambient artificial intelligence (AI) scribes have moved rapidly from experimental pilots to enterprise-wide deployment across health systems, promising reduced documentation burden and improved clinician experience. While research evaluating these tools has expanded quickly, there are no agreed-upon protocols or standardized metrics for assessing their performance, making it difficult to compare findings or cumulatively synthesize evidence across studies. Across 54 recent evaluation studies, we identify ten evaluation dimensions and 40 distinct metrics, operationalized in 96 different ways-35 of them (36%) used by only a single study. Assessment is dominated by documentation efficiency and time, measured in 44 of 54 studies. The other dimensions appear at broadly similar rates (16-24 studies each), and safety and clinical outcome least consistently of all. Ripple effects on the broader care system, such as impact on patients' care outcomes, redistribution of work, changes in billing and coding intensity, and downstream use of notes by other clinicians are rarely assessed. Moreover, the metrics used rely heavily on self-report and are fragmented and inconsistently operationalized, which limits comparability and hinders synthesis across studies. As an effort to support more rigorous and cumulative evaluation, in this paper we review the study designs, data sources, and metrics commonly used to evaluate ambient AI scribes in healthcare settings, discuss the limitations of current evaluation practice, and argue for a more holistic approach grounded in a standardized, multi-dimensional set of metrics.

0.30

LLM Judges Verify Presence, Not Absence: Omission Blindness in AI Clinical Notes and What Recovers It

cs.CL cs.AI ·2026-08-31 ·Sebastian Fox, Luke Markham, Ryan Lail, Michael Karotsieris
benchmarkcode/data similarity 0.63
Abstract · 97 pages, 8 figures. Dataset: https://huggingface.co/datasets/ComposoAI/OmissionBench . Code: https://github.com/composo-ai/omission-bench .…

Ambient AI scribes draft clinical notes, and published audits find their dominant error is omission: information the encounter established that the note fails to record. The standard check is an LLM judge: a second model reads the note against the transcript and flags problems. We ask whether judges detect omissions. Public corpora cannot supply the answer key: their clinician reference notes and transcripts are materially discrepant. Our benchmark has 500 single-error note pairs from audited fact sheets, 298 with a named fact certainly absent and 202 added-or-altered controls. Across eight judge designs, paired discrimination (the flawed note below its clean twin, 0.5 a coin flip) reads 0.79-0.94 on added or altered content and 0.50-0.63 on omissions. On single notes, no design flags omissions reliably more often than perfect notes. Wording changes, voting and GEPA prompt optimisation move the operating point without creating usable detection. Restructuring the task recovers it: list the facts the transcript establishes, then check the note for each. Two methods reach it independently and trade off: a per-fact pipeline, and a GEPA-evolved prompt doing the same in one call. The pipeline's flags name the missing fact and its severity at 2.7% false alarms. The single call detects more (36.9% against 24.6%, p=0.002) at 6.2% false alarms and a tenth of the cost per note. A physician author validated 70 items and, where the two routes disagree, sided with the pipeline on 10 of 10 (p=0.002). A second clinician, not an author, graded the severity rubric blind and agrees to within a grade. On real vendor notes from a companion census no benchmark threshold transfers, but the re-calibrated single call detects more than the best of the eight at half its false-alarm rate. Omissions whose fact is restated elsewhere defeat both routes. We release the benchmark, prompts and judgements.

0.73

Auditable Clinical Timeline Reconstruction with Provenance-Aware Evidence Graphs

cs.AI ·2026-10-05 ·Judith Jeyafreeda Andrew
similarity 0.60
Abstract · 30 pages, 11 Tables, 6 figures

A patient-timeline reconstruction system is auditable only if it keeps the mentions behind each answer, records how facts were revised, and declines to answer when the evidence is not in the text. This study tests these three properties on a fully synthetic corpus (1,000 patients, 3,353 notes, 220 revision edges). Two provenance-aware Evidence Graph operators reduced the node-plus-edge count to 67% and 63% (77-78% of serialized size) while preserving every answer and mention link across 6,813 query points answerable by recency; a fixed-window baseline returned no value for 53.4% of points, unflagged. On evidence-unavailable controls that announce the omission, a BioClinicalBERT gate and a zero-shot LLM gate responded mainly to the announcement. On marker-free controls, BERT abstained on 0 of 81 notes while its accuracy fell from 93.8% to 59.3% across all three relation classes; the LLM's coverage fell from 75.6% to 27.7% on notes its own model family judged undeterminable. Against 482 regenerated gold spans, the LLM's cited evidence reached recall 0.850 and precision 0.864; BERT's span head, trained without span labels, did not localize evidence. A temporally versioned provenance graph stored abstentions as typed, queryable edges. The clean task admits a 0.651-accuracy shortcut, and results describe implementation behaviour on synthetic data, not clinical performance.

0.11

Large language models are vulnerable to incidental information in clinical documentation and reasoning

cs.CL ·2026-10-06 ·Krithik Vishwanath, Brandon Ye, Anton Alyakin, John E. Markert, Aaron Hsieh +2 more
similarity 0.60
Abstract

Large language models (LLMs) are increasingly relied upon to support ambient documentation and clinical reasoning. Here we examine the impact of a failure mode shared between these two applications by assessing their sensitivity to information incidental to the patient encounter. In 576 patient-clinician dialogues, we found that frontier models inserted small-talk exchanges into 35% of notes, while mean quality scores changed by at most 0.20 points on five-point scales. In 3.7% of frontier notes, models misattributed the asides or used them clinically. In 57 mock recorded consultations, background speech from a separate patient encounter at -10 dB leaked into 48.2% of transcripts, with contamination detected in 5.3% of downstream notes generated by four open-weight models. We propose a dual encoding hypothesis of clinical reasoning and distraction in LLMs, with preliminary evidence that LLM components associated with disruption by incidental information also support clinical reasoning. These findings support evaluating resistance to incidental information before clinical use, with safeguards that prevent contamination while preserving clinical reasoning.

0.23

Auditing Escalation Reliability in Healthcare LLM Agents: A Perturbation-Controlled Benchmark of Workflow-State Failures

cs.AI cs.CL ·2026-10-15 ·Zihao Zheng, Junyi Yao, Baichuan Li, Jiayu Long
benchmark similarity 0.59
Abstract · 8 pages, 5 figures

Trustworthy biomedical AI requires reliable action selection when evidence is missing, stale, conflicting, or late, not only accurate answers on static inputs. We instantiate an episode-level evaluation protocol as 400 synthetic healthcare workflow episodes: 40 hand-authored semantic seeds across four task classes, two surface parameterizations, and five controlled variants, scored on ANSWER/ASK CLARIFICATION/ABSTAIN/ESCALATE under a pre-declared 5:1 missed-versus-unnecessary escalation cost. Reference actions are single-author study-policy labels, not clinician-adjudicated ground truth. Across five open-weight configurations (1.7B--9.7B), clean decision accuracy reaches 0.97, yet uncertainty-prompted models miss 32--97% of required escalations. The stronger 9.7B configuration narrows but does not remove the gap, falling from 0.97 clean accuracy to 0.78 under conflict. Verbalized confidence is inconsistent (ECE 0.10--0.54; failure AUROC 0.48--0.77), and a development-tuned confidence-only policy yields no utility gain. A transparent workflow-aware controller improves 5:1 utility for every model and reduces missed escalations to 0.12--0.24, at specificity 0.83--0.93. However, a 30-concept lexical stress test reduces each rule detector's recall from 1.00 on trigger phrases to 0.00 on unseen paraphrases, limiting the controller claim to this benchmark. Seed-clustered statistics, ablations, cross-task transfer, raw outputs, and manifests are packaged for audit. The results motivate explicit workflow-state evaluation while showing that apparently effective routing controls need their own generalization tests.

0.46

Objectify, Don't Delete: Complaint-Derived Evaluation of Ambient Clinical Notes

cs.AI cs.CL ·2026-11-14 ·Nikita Gupta, Narayanan Unny Edakunni, Vikram Okaly, Suranjana Datta, Navya Penubadi +2 more
publishedbenchmarkpositioncode/datahot direction similarity 0.59
Abstract · Accepted at the Third Workshop on GenAI for Health (GenAI4Health), NeurIPS 2026 (non-archival). 16 pages, 5 figures, 11 tables. Code and dat…

Evaluating the quality of AI-generated clinical notes is hard: standard metrics like ROUGE measure lexical similarity to reference notes, while expert checklists encode what committees believe matters. Neither captures what clinicians actually complain about. Recent work has shown that evaluation criteria can be mined from user feedback and filtered to criteria that LLM judges can reliably enforce. We argue that this is where much of the value is lost. The criteria that fail enforceability are disproportionately the ones clinicians raise most often, because high-frequency complaints are stated as several questions glued together. No yes/no judgment can grade such composites as posed. We introduce an objectification step that rewrites such criteria into sets of scoped, determinate decisions. We demonstrate the approach through an evaluation pipeline that mines criteria from complaints, objectifies them, and deploys LLM judges against both planted defects and production notes. Across eleven defects planted into ACI-bench reference notes, objectified judges localize violations with median recall of 0.95, while reference metrics change by at most 0.037. Given the complaint as one broad question, the same judges still find every planted defect, but they also flag 70% of the unperturbed reference notes; one section-pair question per call raises Youden's J from 0.30 to 0.72 (by 0.19 to 0.26 with prompt effort matched). We release ACI-Defect, a perturbation benchmark; clinician-reviewed instance-level labels showing quality gaps in the ACI-bench gold standard (32 of 40 notes contain hallucinations; 40 of 40 omit discussed facts); and grounding-judge verdicts. On 1,446 production notes, mean instance-rate burden falls at every clinician-rating step (rho=-0.15), a small association. Defect counts have to be kept per span rather than collapsed into one pass/fail bit per note.

0.47

Auditable Clinical Support with Decision Agents

cs.AI ·2026-11-18 ·Tiancheng Bao, Riga Wu, Jan Wienhold, Sebastian Billig, Patrick Winnersbach +11 more
similarity 0.58
Abstract · 74 pages, 6 main figures, 19 supplementary figures

Clinicians reviewing a diagnostic work-up will ask what was considered at each step and why the assessment changed. Agents powered by free text can reach physician-level diagnostic accuracy, but their written reasoning does not always reflect the factors that went into the decision. Here, we present Decision2Care, a decision agent that works up the acutely ill patient without producing any text. A decision model assigns a probability to each permitted EHR action, and fixed rules carry out the most probable one. We evaluated Decision2Care on the records of 546 emergency admissions across 12 diseases. Decision2Care reached a diagnostic accuracy of 86.5%, compared with 86.1% for the MIRA-v2 agent, and required a median of 2.2 s per work-up, compared with 92-100 s. Each work-up tracked which options Decision2Care was considering at each step. In 10 of the 12 diseases, the differential diagnosis changed most at the test on which the guideline bases the diagnosis. Where Decision2Care was most confident after a single work-up, all but four of its diagnoses were correct (98.5%). We traced each of these four errors back to a single imaging report. Three of them were corrected when that report was removed. The same kind of decision was used to select the treatments, and Decision2Care's drug orders were judged guideline-adherent more often than MIRA-v2's. In emergency patients, its prediction of death was comparable to that of three intensivists on the same cases. In five of the eight intensive care cohorts, it exceeded the best of the three 24-h severity scores within 2-6 h of records. Our results show that decision agents can carry out clinical work-ups while recording the options, probabilities, and execution rules behind each action for audit.

0.30

AI Morbidity and Mortality: A Framework for Clinical AI Failure Review

cs.AI cs.HC ·2026-08-31 ·Paulius Mui, Dean F. Sittig, Steve Labkoff, Sanjay Basu
similarity 0.58
Abstract

Clinical artificial intelligence is increasingly embedded in real-world care, yet existing safety mechanisms are poorly suited to reconstructing and learning from individual AI-related errors and near-misses. Aggregate model monitoring can identify performance changes, and traditional patient safety reporting can capture adverse events, but neither is designed to explain how risk emerges across the interaction among AI systems, clinicians, workflows, and institutional controls. We propose AI Morbidity and Mortality (AI M&M), a structured, blameless framework for case-based review of clinical AI failures. The framework combines standardized case intake, evidence preservation and investigator-level reconstruction, tool-in-loop attribution, and corrective-action tracking. Each event is classified across four linked dimensions: Trigger - Mechanism - Clinical Pathway - Corrective Action, separating the condition that exposed a vulnerability from the process that produced risk, its consequence for care, and the remediation assigned. We demonstrate the framework using five illustrative outpatient medication and clinical decision-support cases; two clinician reviewers independently applied all four classification axes and reached agreement across all 20 axis-level classifications. AI M&M is intended to complement, rather than replace, model monitoring, patient safety reporting, and regulatory oversight by converting individual AI-in-workflow failures into actionable institutional learning. Prospective evaluation across institutions, AI systems, and clinical settings is needed.

0.13