CS Paper Radar

Interpreting Selective-Review Coverage for Head-and-Neck Auto-Contours

Jaden Moon, Caiwen Jiang, Songlin Zhao, Wei Liu

eess.IV ·submitted 2026-11-11 09:44 UTC · v1
unusual

Abstract

Selective-review systems aim to reduce human review by passing candidates predicted to be low risk. However, coverage (the fraction passed) can be misleading when measurements needed to interpret risk are unavailable. We separate structural evaluability (a nonempty mask with all required measurements available), computational-endpoint status, and pass-or-review decisions using archived Mayo records and controlled OpenKBP analyses. In 3,968 Mayo records, all 1,167 recorded empty predictions (predicted target-organ masks containing zero voxels despite nonempty reference masks) were endpoint-negative and passed both modules, accounting for approximately 76% of each pass set. In a held-out OpenKBP test, a logistic-regression router achieved an area under the receiver operating characteristic curve of 0.833 and average precision of 0.449 but passed all 544 non-evaluable candidates, including 542 prespecified empty-mask controls and 2 erosions that became empty. A structural gate removed those passes without changing scores or the threshold, preserved all evaluable passes, and assigned 98.71% of endpoint-positive candidates to review. Under the original preprocessing and in patient-disjoint development evaluation, a router trained only on evaluable candidates and a router modeling an unavailable state likewise passed no non-evaluable candidates, with similar evaluable discrimination and at least 99.0% of endpoint-positive candidates assigned to review in pooled outer-fold predictions. These results show that coverage should be interpreted jointly with candidate eligibility, endpoint scope, missingness handling, and routing rules; they do not establish clinical validity, deployment safety, or natural-failure prevalence.

Comment
5 pages, 2 figures, 3 tables. Submitted to IEEE ISBI 2027

Closest papers

Nearest neighbours by meaning across the whole index.

Risk Control Certifies Rates, Not Magnitudes: An Audit of Selective Fetal Biometry

cs.AI cs.CV ·2026-11-04 ·Zhengshuai Yang, Linna Jiang, Changyun Li, Guihu Zhao
theory similarity 0.58
Abstract · 10 pages, 2 figures, 3 tables

Prenatal ultrasound biometry must return a head circumference (HC) and refuse when the image cannot support one. Selective prediction trades coverage against error, but its finite-sample guarantees bound the rate of gross errors, not their magnitude. We audit a tool-grounded biometry pipeline on two separately pre-registered four-way splits of the 999 labelled HC18 images, retraining the segmenter three times on each. Calibrating the contour-completeness threshold by exact Clopper-Pearson risk control returns a certificate indistinguishable from a hand-set floor, yet the pipeline still emits a 271.3 mm error: a small, geometrically complete ring fitted to an image whose true HC is 324.6 mm. The accepted candidate scores 0.94 completeness, so the score cannot see the failure, and one outlier among $\approx 150$ answers leaves the certified risk bound ($α= 0.10$) intact. A second, untouched split reproduces the mechanism on a different image (233.3 mm). Constraining the admissibility region---the anatomical range in which the measurand is defined---removes the family instead: raising the lower bound from 50 to 55 mm costs 0.4 coverage points and cuts the worst-case error on both splits to 11.4 and 11.1 mm, whereas suppressing it through the completeness threshold costs 19.0 and 12.1 points. At an anatomically defined 70 mm the frozen tests give 1.91 and 1.81 mm MAE.

0.30

Target leakage, not model class, explains reported accuracy in survey-based cardiovascular screening: a leakage-tiered audit of glass-box and tabular foundation models

cs.CL ·2026-09-10 ·Raad Bin Tareaf, Murad Al-Rajab, Samia Loucif, Samer Ellaham, Cedric Schmitz
hot direction similarity 0.57
Abstract

Cardiovascular screening models trained on national health surveys routinely report areas under the receiver operating characteristic curve (AUROC) near 0.89. We asked whether that accuracy reflects learning or target leakage, whether tabular foundation models change the answer, and whether the properties deployment requires survive joint examination. We benchmarked ten classifiers spanning linear, tree-ensemble, neural, glass-box, and tabular foundation classes for prevalent myocardial infarction in 442,067 respondents of the 2022 Behavioral Risk Factor Surveillance System across five feature tiers of decreasing leakage risk. Each was audited for discrimination, calibration, fairness at an explicit screening threshold, conformal coverage, explanation faithfulness, and inference cost, then applied -- models and thresholds frozen -- to 430,755 respondents of 2023. Removing two post-diagnostic features cost every model 0.049-0.051 AUROC, collapsing the field into a 0.0045-wide band. The glass-box explainable boosting machine was non-inferior to every alternative within a pre-specified 0.005 margin while scoring the cohort roughly 104 times faster than the strongest foundation model. One threshold detected 75.4% of women's infarctions against 89.0% of men's; editing the model's shape functions reduced the gap to 0.010. Marginal conformal prediction gave 0.86 coverage to men and 0.82 to adults over 60; Mondrian calibration repaired every stratum. Frozen models transported within 0.002 AUROC. Reported headroom in this literature is a property of the feature set, not the learner. Transparency cost nothing measurable and made fairness repair and uncertainty conditioning directly auditable. Evaluation practice, not model capacity, is the binding constraint.

0.37

CHARTER: Auditing Reference Substitution in Hierarchical Compact-Evidence Evaluation for Computational Pathology

cs.CV cs.LG ·2026-10-06 ·Hyun Do Jung, Jungwon Choi, Soojung Choi, Yujin Oh, Hwiyoung Kim
similarity 0.57
Abstract

In digital pathology, compact evidence is often used to explain or audit predictions made by whole-slide image multiple instance learning models. In hierarchical compact-evidence pipelines, candidate filtering introduces a strategy-specific candidate-conditioned prediction alongside the original full-bag prediction. If the evaluation reference changes while the intended target remains the original full-bag prediction, however, not only can the measured fidelity of the same compact evidence change, but comparisons between competing candidate strategies can also change. To make this dependence explicit, we introduce CHARTER, a reference-aware evaluation charter that asks researchers to DECLARE the intended target and reference, QUANTIFY candidate-induced prediction shift, and AUDIT the stability of comparative conclusions. Across the 15 comparisons in our main five-seed Random-K audit, 4 showed determinate reversals; in a matched native-ranking stress test, the ACMIL comparison changed from REVERSED to PRESERVED. CHARTER turns otherwise implicit candidate-filtering and reference choices into an auditable evaluation specification, helping distinguish genuine preservation of the intended prediction from apparent gains induced by changing the prediction being explained.

0.17

Evaluator-Dependent Patient-Adaptive ECG Lead-Channel Allocation

cs.CV ·2026-08-27 ·Xiaoyang Li, Zeyan Tao
similarity 0.56
Abstract · 17 pages: 5-page main paper and 12-page supplementary material; 6 figures and 16 supplementary tables. Updated figures and supplementary mat…

The diagnostic value of an ECG channel depends on the model that interprets it. We test whether adaptive acquisition retains its advantage over fixed protocols when that model changes. Two policies developed with a logistic evaluator are frozen and assessed with a masked waveform ResNet1D, using exhaustive, metric-matched fixed comparators. On PTB-XL, replacing the evaluator reverses the mean adaptive advantage in negative log-likelihood and Brier score across the tested budgets, while calibration responds less uniformly. The shift persists with common fixed references and broader training-mask exposure. Training a policy against the stronger evaluator partly recovers the lost advantage. These retrospective exploratory results show that acquisition quality cannot be assessed independently of the downstream evaluator and motivate validating adaptive policies with the model intended for diagnosis.

0.26

The Ceiling Is in the Channel: Auditing Learner Gaps and Measurement Frontiers in Clinical Prediction

cs.AI ·2026-09-01 ·Sayeed Shafayet Chowdhury, Nusrat Jahan, Snehasis Mukhopadhyay, Shiaofen Fang, Vijay R. Ramakrishnan
similarity 0.55
Abstract

Clinical prediction can saturate for two different reasons: a fitted learner may fail to extract available information, or the recorded variables may impose a population frontier. We separate these quantities through the \emph{learner gap} and the \emph{measurement-channel ceiling}. Optimal balanced accuracy is characterized by total-variation separation, yielding architecture invariance, a sharp partial-identification result under replacement contamination, a cross-fitted ceiling estimator, and exact conditions for multimodal decision improvement. We add two finite-sample diagnostics, namely a label-permutation optimism floor and an underfit curve, and validate the audit on three real cohorts: UCI readmission ($n=99{,}343$), BRFSS diabetes ($n=253{,}680$), and NHANES HbA1c ($n=10{,}219$). Well-tuned gradient boosting nearly reaches the estimated frontier in UCI and BRFSS, whereas deliberately or practically deficient learners retain large gaps. NHANES yields a null difference between questionnaire and measured marginal frontiers but a significant joint complementarity gain, refining the simplistic claim that an objective modality must dominate. Across all cohorts, modest AUROC gains coexist with substantially larger Bayes decision-flip rates, and several architectures estimate similar frontiers while their achieved balanced accuracy differs sharply. A PRISMA-guided synthesis of 104 clinical tasks then shows that the same channel-level regularities recur across more than 18 disease categories: a broad but non-universal structured-clinical region, diminishing same-channel gains across model families, and higher performance when measurement channels change. The framework converts saturation from an empirical observation into an auditable decision: improve the learner when headroom remains; improve measurement when it does not.

0.18

CleanScore: Black-Box Benchmark Audits with Negative Controls and Sensitivity Bounds

cs.LG stat.ME ·2026-08-27 ·Jeffery Opoku, David Banahene
benchmarkcode/data similarity 0.55
Abstract · 47 pages, 5 figures, 27 tables. Revised version that supersedes v1. Code, items and pre-registrations: https://github.com/jopoku16/cleanscor…

Public benchmark scores reflect skill, prior exposure to the questions, or both, and for most models the training data are unknown. CleanScore is a black-box audit: the estimator needs only a correct-or-incorrect score for each form, not training data or weights. Each benchmark question becomes a parent item with one public form and two independently written fresh forms that keep its numbers, facts and answer. The audit reports an interval for the public-form advantage, not a verdict, and a private control bank with an explicit transport radius provides a proxy for the ordinary form gap that a rewrite alone can produce. A registered controlled-exposure experiment, a preliminary validation, detects planted exposure in one of two model families. A registered audit of five open models on 200 GSM8K and 200 ARC-Challenge items (ARC with stem-only rewrites, scored by option log probabilities) finds no exposure-consistent advantage, and two reruns declared before they were run (GSM8K at a longer token budget, ARC scored from generated letters) leave that conclusion unchanged. For four of the ten model-benchmark pairs the upper end of the interval is about five points or less, and for none is it above 21 points. The registered claim rule is much less sensitive than the primary interval: it flags a planted ten-point advantage in 5% to 11% of audits. Registered positive controls show what a null can mean. In four models, each trained under four seeds, items leaked into fine-tuning gained 25 points on average over unleaked items on the leaked wording and 19 points on paraphrases the model never saw, so a substantial share of the effect, estimated at 76% (95% interval 50% to 113%), is invisible to a paraphrase audit. A null on surface form says much less about contamination than the name suggests.

0.32

Auditing black-box clinical prediction models with a large language model through queries alone: a blinded test with planted flaws

cs.LG cs.AI ·2026-11-18 ·Zhiyu Liu, Xinyu Yang
code/data similarity 0.54
Abstract · 15 pages, 2 figures, 6 tables. Models, prompts, replies with tool calls, and code: https://github.com/Chth1z/llm-black-box-model-audit

Large language models (LLMs) are used to explain clinical prediction models, on the promise that they can say what a model computes, find its faults and even reveal new knowledge in it. We tested the three promises where the answers could be checked. From the International Stroke Trial we trained four kinds of model (logistic regression, explainable boosting machine, gradient-boosted trees, neural network) for two outcomes on patients randomised earlier, planted one flaw in each of 24 copies (an under-predicted subgroup, a reversed risk factor or an implausible step) and mixed them with the 8 clean models. GPT-6 Astra audited each model three times, blind, through a tool that only returned the model's predictions; the judging rules were committed before any run and applied by program. Its surrogate models, with a median of 128 terms, reproduced the audited models' log-odds with a mean $R^2$ of 0.976 (0.959 for an additive surrogate of 42 terms fitted by an analyst). It found the planted flaw in 69 of 72 runs (96%; 95% CI 80% to 99%); a script written for the purpose found all 24. It also reported many more problems: 60% of 1,089 checkable reports failed the pre-specified check against the model's average behaviour; post hoc, most of these were real but small steps, and 15% of the checkable reports were not found in the model. Of 601 unexpected relationships it read out of the clean models, 11% held in patients randomised later (random pairs 6%; a regression scan's shorter list of its strongest candidates, 28%); after a check on the training data, 33% against 30%. With query access alone, an LLM can describe a black-box model faithfully and find nearly every planted flaw, as a purpose-written script also did; its reports of problems must be checked on the model and its discoveries on data.

0.24

AGO AI Quality Gate: Evidence-First Release Decisions for Retrieval-Augmented Generation

cs.CL ·2026-10-01 ·Giulio Zeloni, Enrico Lo Conte, Salvatore Rionero, Giuseppe Santoro, Alessandro Rastelli +1 more
publishedbenchmark similarity 0.54
Abstract · 14 pages, 1 figure, 4 tables. Submitted version (pre-review). Accepted at NFMCP 2026, ECML PKDD 2026 Workshops

Enterprises adopting retrieval-augmented generation (RAG) face a recurring operational decision: promote, revise, or block a system version. The evidence is incomplete and the metrics come from fallible LLM judges. We report on AGO AI Quality Gate (AGO), an evidence-first quality-gate framework deployed in industrial RAG assessment engagements. AGO integrates four key components: a four-state decision model that treats missing data and judge errors as explicit outcomes; layered scoring combining deterministic checks, local guardrails, and structured LLM evaluation; a stratified beta-binomial gate that quantifies regression risk probabilistically; and a mandatory meta-evaluation protocol to validate the LLM judge before it influences decisions. Since engagement data is proprietary, we evaluate the judge layer on RAGBench, a public benchmark of 100k annotated RAG traces across 12 datasets. On identical stratified test samples (N=1200 per judge), a low-cost judge (gpt-4.1-nano) detects non-adherent answers barely above chance (AUROC 0.603 [0.570, 0.634]), despite producing flawless protocol output, while gpt-4o reaches 0.783 [0.756, 0.807] -- yet its per-domain performance still ranges from 0.62 to 0.88. A fixed-seed gate study spanning regression, no change, and improvement quantifies unsafe promotion, false-alarm cost, and improvement throughput. Under regression, the decision-grade profile reduces unsafe promotion to 22.2%-35.1%, against 29.3%-41.8% for a naive gate. These results support the design choices that judge quality must be measured per engagement and that point estimates alone are not a release decision.

0.32