CS Paper Radar

Directionally Supervised Neuromorphic Protection for Distribution Systems Using Local Measurements

Saurabh Prabhakar, Yubo Song, Pascal Schirmer, Bijaya Ketan Panigrahi, Subham Sahoo

eess.SP ·submitted 2026-11-12 12:29 UTC · v1

Abstract

Reliable protection under varying power system operating conditions requires rapid fault detection while preserving selectivity against external faults and non-fault disturbances. This requirement is particularly challenging in communication-free schemes, where relays must determine trip conditions solely from local electrical measurements. To address this challenge, this paper proposes a directionally supervised neuromorphic protection scheme that integrates disturbance-responsive leaky integrate-and-fire dynamics with a direction-dependent firing threshold to distinguish internal faults from reverse-direction events. The unified relay architecture combines local disturbance detection, directional discrimination, and spike-based trip generation without requiring inter-relay communication. Its performance is evaluated under grid-connected and islanded conditions using a ring microgrid and the IEEE 13-node distribution feeder. Across 240 evaluated fault scenarios, the framework achieves median operating times of 5.4--7.6 ms across the two networks, with 78% of cases operating within 10 ms and 95% within 20 ms. It also maintains protection security during load disturbances, while fault-resistance analysis confirms its response under high-resistance faults. Controller-hardware-in-the-loop (CHIL) experiments using an RTDS simulator and an external dSPACE controller demonstrate trip-command assertion in approximately 10 ms and 5 ms for the tested single-line-to-ground and three-phase-to-ground faults, respectively. The results establish real-time feasibility within the evaluated conditions and characterize operating-time variability across fault types and resistance levels for different network configurations.

Comment
Submitted to IEEE Transactions on Smart Grid

Closest papers

Nearest neighbours by meaning across the whole index.

Transferable Neuromorphic Protection for Distribution Networks

eess.SP ·2026-11-12 ·Saurabh Prabhakar, Yubo Song, Pascal Schirmer, Bijaya Ketan Panigrahi, Subham Sahoo
benchmark similarity 0.77
Abstract · Submitted to IEEE Transactions on Smart Grid

Protection of converter-dominated distribution networks is challenging due to limited fault currents, operating-mode transitions, bidirectional power flow, and heterogeneous network configurations. This paper proposes a scale-invariant neuromorphic protection framework to enable transferable protection decisions across such networks. The framework integrates asset-based normalization, multi-domain disturbance representation, event-driven spike encoding, leaky integrate-and-fire (LIF) dynamics, adaptive threshold regulation, and directional supervision within a unified mathematical formulation. Local voltage, current, active power, and reactive power measurements are transformed into dimensionless disturbance representations, while latency encoding and membrane integration capture disturbance intensity and temporal evolution. The framework is evaluated across four heterogeneous network configurations: a two-DER inverter-interfaced microgrid, an islanded ring microgrid, the IEEE 13-node feeder, and the CIGRE European medium-voltage benchmark. Across 480 cases, it achieves a median operating time of 7.6 ms, with 94.2 % of cases operating within one power cycle. The results demonstrate selective protection across different electrical ratings and network topologies using a common parameterization without network-specific retuning, highlighting the potential of neuromorphic processing for physically interpretable, communication-free protection of converter-dominated distribution networks.

0.30

Characterizing Cross-Relay Generalization Failure in Machine Learning-Based Power System Protection

cs.LG ·2026-10-20 ·Nithin Pradeep Nadayil Kizhakkethil, Julian Oelhaf, Christian Bergler, Andreas Maier, Siming Bayer
published similarity 0.65
Abstract · 6 pages, 3 figures. Accepted for presentation at the IEEE Power & Energy Student Summit (PESS 2026), Karlsruhe, Germany

Machine learning-based fault detectors are often evaluated at the relay locations used for training, although local voltage and current measurements vary across power networks. This work investigates cross-relay generalization for binary detection of faults anywhere in the network using local measurements, rather than line-selective tripping. Using 50 ms windows from a simulated 110 kV transmission network, we evaluate a multilayer perceptron across all 64 source target combinations of eight relays and five random seeds. A shared simulation-level split and source-only threshold selection provide a controlled held-out evaluation without target-specific calibration. Despite nearly unchanged mean F1-scores (0.730 within-relay versus 0.734 cross-relay), the mean false-positive rate (FPR) increases from 0.088 to 0.341, while the mean false-negative rate decreases from 0.399 to 0.318. The change is strongly directional: models trained at Bus 2 relays yield a mean FPR of 0.670 at Bus 1 and Bus 3 relays, compared with 0.096 for cross-relay transfers within the same bus group. Linear probing indicates that learned representations retain coarse bus-group information, while exploratory class-conditional latent distribution analysis shows no consistent monotonic association with transfer errors. These findings demonstrate that aggregate metrics can conceal location-structured changes in false-alarm behavior, highlighting the importance of evaluating error types separately when assessing cross-relay generalization.

0.23

A Systematic Evaluation of Machine Learning Methods for Fault Detection and Line Identification in Electrical Power Grids

cs.LG eess.SP ·2026-09-15 ·Julian Oelhaf, Georg Kordowich, Paula Andrea Pérez-Toro, Tomás Arias-Vergara, Andreas Maier +2 more
publishedhighly cited similarity 0.62
Abstract · Accepted at ICASSP 2025. 5 pages, 4 figures. Published version: DOI 10.1109/ICASSP49660.2025.10890544

The integration of renewable energy sources into the electrical grid introduces complex challenges in fault detection and coordination of grid recovery mechanisms. Traditional relay protection systems, which operate based on static rules and predefined thresholds, are inadequate for addressing these challenges, particularly in detecting and isolating faults such as short circuits. Consequently, the conventional methodologies applied to electrical network protection frequently fail to achieve optimal performance in fault detection, especially in terms of adherence to safety standards and the selective limitation of damage. Recent research indicates that machine learning (ML)-based approaches can effectively tackle these issues; however, variations in grid configurations and analysis windows have impeded consistent comparative assessments. In this study, we assess the efficacy of various ML models in detecting electrical faults and pinpointing defective transmission lines within a 10 ms measurement interval - a critical time-frame for real-time operational viability, for the first time. The most effective model attained an F1 score of 0.991 +/- 0.018 and demonstrated a processing time of 0.342ms +/- 0.509ms.

0.52

Protection-Oriented Assessment of Machine Learning-Based Fault Detection in Power Systems

cs.LG eess.SP ·2026-11-13 ·Julian Oelhaf, Georg Kordowich, Changhun Kim, Christian Bergler, Andreas Maier +2 more
publishedhot direction similarity 0.59
Abstract · 9 pages, 3 figures, 5 tables. Accepted for oral presentation at the 21st International Conference on Developments in Power System Protection…

Machine learning (ML)-based fault detectors are increasingly proposed for power system protection, yet aggregate metrics can obscure the consequences of false and missed trips. We present a protection-oriented assessment of three ML detectors and a sequence-current reference on PROTECT-90, comprising 9,022 simulated fault episodes on a 90 kV double-circuit line. The assessment combines five window conditions, causal window-end labelling, episode-grouped cross-validation, and operating-point selection under a fixed security budget. It reports security, dependability, detection timing, decision margins, and episode-level nuisance assertions. Gradient-boosted trees, a convolutional neural network, and logistic regression achieve AUC-ROC values above 0.999, yet at a security budget of $10^{-3}$ their developed-fault missed-trip rates range from 0.007% to 1.99%. Post-clearing false-trip rates of approximately 0.12-0.16% per window coexist with nuisance assertions in 11.3-19.1% of episodes. Among the analysed physical descriptors, missed trips are most consistently associated with higher fault resistance within the sampled range. An analytical current proxy suggests a fault-current gradient only partly reproduced by waveform-derived current (rank correlation 0.62). No single topology state or faulted phase consistently dominates within the sampled domain. Because PROTECT-90 contains fault episodes only, security is assessed on pre-fault and post-clearing windows rather than independent non-fault disturbances.

0.27

EvEMTBench: An Open Benchmark for Machine Learning in Power System Protection

eess.SY cs.LG ·2026-09-23 ·Julian Oelhaf, Georg Kordowich, Christian Bergler, Andreas Maier, Johann Jäger +1 more
benchmarkcode/data similarity 0.58
Abstract · 15 pages, 3 figures. Supplementary information included. Code: https://github.com/EvEMTBench/evemtbench-benchmark

Studies of machine-learning-based power system protection are difficult to compare because task definitions, measurement access, data partitions, metrics, and generalization conditions often differ. EvEMTBench addresses this gap with an open, executable, and versioned benchmark that fixes these evaluation choices while leaving model design open. Across four grids spanning 20-345 kV, it defines 12 protection and event-analysis functions instantiated as 24 scored tasks and supports structured evaluation across observability conditions, predefined distribution shifts, and zero-shot and fine-tuned cross-grid transfer. Committed partitions, leakage controls, and reproducible reporting provide a common basis for comparing future methods. A reference evaluation spanning trivial, conventional, feature-based, and deep-learning baselines shows that wider observability is not uniformly beneficial, shifted conditions can reveal failures not apparent in-distribution, and cross-grid transfer is substantially stronger for fault detection than for fault localization. Protection-relevant diagnostics identify failure modes not apparent from primary metrics alone. EvEMTBench therefore makes generalization in machine-learning-based protection an explicit and reproducible evaluation problem.

0.22

Robust Industrial Cyber Physical Classification Using Neuromorphic Temporal Embeddings and Hybrid SNN XGBoost Under Machine Unlearning Attacks

cs.LG cs.CRcs.NE ·2026-09-09 ·Ammar Kamoona, Sajad Koushkbaghi, Mahdi Jalili, Peter McTaggart, Xinghuo Yu
similarity 0.54
Abstract · 13 pages, first draft

The digitalisation of electrical distribution networks has increased the exposure of power-grid infrastructure to cyber attacks. Existing intrusion detection systems (IDSs), however, often rely on computationally expensive deep learning models that are difficult to deploy at the edge. Periodic retraining also exposes these systems to machine unlearning attacks, where selective data removal can degrade detection performance. We propose a hybrid Spiking Neural Network (SNN) and XGBoost architecture that combines efficient temporal encoding with a lightweight classifier and provides structural resilience to such attacks. The SNN is trained once on clean data and used as a fixed feature extractor, while only the XGBoost classifier is retrained during model updates. Evaluated on two real-world public power-system datasets, the proposed method achieves 99.9\% accuracy (F1-macro 0.999) on the Synchrophasor dataset and 95.0\% accuracy (F1-macro 0.943) on the MSU/ORNL dataset, outperforming standalone baselines. Under selective label-flipping attacks, the hybrid model loses only 0.9\% F1-macro at 10\% poisoning and delays target-class collapse from 60\% to 70\% poisoning compared with raw models. These results demonstrate that neuromorphic temporal encoding can provide both accurate cyber-attack detection and improved resilience to data poisoning in cyber-physical systems.

0.24

One-Cycle Fault Classification and Faulted-Line Identification on the PROTECT-90 Dataset: An Initial Application Benchmark

eess.SY cs.LG ·2026-10-02 ·Emad Abukhousa, Abdulaziz Qwbaiban, Saman Zonouz, A. P. Sakis Meliopoulos
benchmarkcode/data similarity 0.53
Abstract

Open electromagnetic-transient datasets are beginning to make reproducible learning-based protection studies possible, but the practical use of these datasets still requires application-level benchmarks that define timing, sensing, and validation assumptions. This paper presents an initial application benchmark on the recently released PROTECT-90 dataset for two protection-oriented tasks: fault-type classification and discrete faulted-line identification. A compact one-dimensional convolutional neural network (CNN) is evaluated using post-inception windows of 0.25, 0.5, 1, and 2 cycles under strict episode-wise splitting. A non-convolutional multilayer perceptron (MLP) is also trained as an architecture-control baseline. The results show that both tasks are nearly saturated under full observability, with one-cycle test accuracies of 99.84% for fault type and 100.00% for line identification. The main performance variation appears under reduced observability: current-only inputs preserve line identification accuracy at 100.00%, whereas voltage-only inputs reduce line identification accuracy to 53.09% with the CNN and 50.57% with the MLP. This indicates that the limiting factor is measurement information rather than neural architecture. Additional stratified checks show stable performance across topology states and fault-resistance bins, while CPU inference contributes only 0.528 ms to the one-cycle total decision time of 20.53 ms.

0.29

Multi-Library Feature Engineering and Statistically Validated Classification for Power Swing Detection and Stability Assessment

eess.SP cs.LG ·2026-11-16 ·Pallav Kumar Bera, Samita Rani Pani, Ranjeeta Patel
published similarity 0.53
Abstract · Accepted at Annual Conference of the IEEE Industrial Electronics Society (IECON) 2026; 52nd Edition; Doha, Qatar

Faults occurring during power swings, and the evolution of a swing into an unstable condition, cause distance-relay maloperation and cascaded outages. This paper identifies faults, faults during power swings, and power swings, and distinguishes stable from unstable swings in a 9-bus WSCC system modeled in PSCAD/EMTDC. Three time-series feature libraries (tsfresh, TSFEL, and tsfeatures) are applied to the 3-phase relay voltages and currents, giving 3286 statistical, temporal, spectral, and fractal descriptors per event window. A two-step feature selection (Boruta all-relevant filtering followed by RFECV- and SHAP-guided minimal-optimal pruning) reduces the feature set to 18 compact, non-redundant features. 14 classifiers spanning linear, kernel/instance-based, probabilistic, neural, and tree-ensemble/boosting families are then benchmarked under repeated stratified cross-validation, with model differences assessed by a Friedman/Nemenyi omnibus-and-post-hoc test and a Nadeau--Bengio corrected paired t-test. Rotation Forest (ROF) identifies the three event types with 99.98% and SVM-RBF distinguishes stable from unstable swings with 97.97% balanced accuracy. The results show that automated, library-driven feature extraction combined with rigorous statistical model comparison achieves near-perfect discrimination while retaining feature-level interpretability through SHAP importance.

0.28