Transferable Neuromorphic Protection for Distribution Networks

Saurabh Prabhakar, Yubo Song, Pascal Schirmer, Bijaya Ketan Panigrahi, Subham Sahoo

eess.SP ·submitted 2026-11-12 12:19 UTC · v1
benchmark

Abstract

Protection of converter-dominated distribution networks is challenging due to limited fault currents, operating-mode transitions, bidirectional power flow, and heterogeneous network configurations. This paper proposes a scale-invariant neuromorphic protection framework to enable transferable protection decisions across such networks. The framework integrates asset-based normalization, multi-domain disturbance representation, event-driven spike encoding, leaky integrate-and-fire (LIF) dynamics, adaptive threshold regulation, and directional supervision within a unified mathematical formulation. Local voltage, current, active power, and reactive power measurements are transformed into dimensionless disturbance representations, while latency encoding and membrane integration capture disturbance intensity and temporal evolution. The framework is evaluated across four heterogeneous network configurations: a two-DER inverter-interfaced microgrid, an islanded ring microgrid, the IEEE 13-node feeder, and the CIGRE European medium-voltage benchmark. Across 480 cases, it achieves a median operating time of 7.6 ms, with 94.2 % of cases operating within one power cycle. The results demonstrate selective protection across different electrical ratings and network topologies using a common parameterization without network-specific retuning, highlighting the potential of neuromorphic processing for physically interpretable, communication-free protection of converter-dominated distribution networks.

Comment
Submitted to IEEE Transactions on Smart Grid

Closest papers

Nearest neighbours by meaning across the whole index.

Directionally Supervised Neuromorphic Protection for Distribution Systems Using Local Measurements

eess.SP ·2026-11-12 ·Saurabh Prabhakar, Yubo Song, Pascal Schirmer, Bijaya Ketan Panigrahi, Subham Sahoo
similarity 0.77
Abstract · Submitted to IEEE Transactions on Smart Grid

Reliable protection under varying power system operating conditions requires rapid fault detection while preserving selectivity against external faults and non-fault disturbances. This requirement is particularly challenging in communication-free schemes, where relays must determine trip conditions solely from local electrical measurements. To address this challenge, this paper proposes a directionally supervised neuromorphic protection scheme that integrates disturbance-responsive leaky integrate-and-fire dynamics with a direction-dependent firing threshold to distinguish internal faults from reverse-direction events. The unified relay architecture combines local disturbance detection, directional discrimination, and spike-based trip generation without requiring inter-relay communication. Its performance is evaluated under grid-connected and islanded conditions using a ring microgrid and the IEEE 13-node distribution feeder. Across 240 evaluated fault scenarios, the framework achieves median operating times of 5.4--7.6 ms across the two networks, with 78% of cases operating within 10 ms and 95% within 20 ms. It also maintains protection security during load disturbances, while fault-resistance analysis confirms its response under high-resistance faults. Controller-hardware-in-the-loop (CHIL) experiments using an RTDS simulator and an external dSPACE controller demonstrate trip-command assertion in approximately 10 ms and 5 ms for the tested single-line-to-ground and three-phase-to-ground faults, respectively. The results establish real-time feasibility within the evaluated conditions and characterize operating-time variability across fault types and resistance levels for different network configurations.

0.30

Quantifying the Unintentional Islanding Risk: A Comparative Study on Active Distribution Network

eess.SY ·2026-09-10 ·Harshit Nayak, Edoardo Daccò, Jose Luis Rueda Torres, Davide Falabretti
similarity 0.60
Abstract

The growing share of Inverter-Based Resources (IBRs) is changing the operation of modern Active Distribution Networks (ADNs), raising concerns for grid stability, protection, and reliability. In this paper, we investigate the dynamic behavior of a Medium-Voltage (MV) portion of an ADN during the transition from grid-connected to islanded operation. The study considers a Grid-Following (GFL) converter and Synchronous Generators (SGs) operated under two distinct regulation modes: a fixed-setpoint, non-regulating condition representative of present-day distribution networks, and an active frequency/voltage-regulating condition representative of SGs equipped with governor and AVR control. Detailed electromagnetic transient (EMT) models of both technologies have been developed in DIgSILENT PowerFactory that quantifies the sensitivity of island persistence to SG regulation mode and inertia. The results show that when DERs operate at a fixed power setpoint, the risk of forming a sustained, undetected electrical island is limited, since the isolated network drifts out of the protection thresholds within tens of seconds. Conversely, enabling frequency and voltage regulation on the SGs is sufficient to sustain an unintentional island indefinitely without triggering conventional protection, regardless of system inertia.

0.28

EvEMTBench: An Open Benchmark for Machine Learning in Power System Protection

eess.SY cs.LG ·2026-09-23 ·Julian Oelhaf, Georg Kordowich, Christian Bergler, Andreas Maier, Johann Jäger +1 more
benchmarkcode/data similarity 0.57
Abstract · 15 pages, 3 figures. Supplementary information included. Code: https://github.com/EvEMTBench/evemtbench-benchmark

Studies of machine-learning-based power system protection are difficult to compare because task definitions, measurement access, data partitions, metrics, and generalization conditions often differ. EvEMTBench addresses this gap with an open, executable, and versioned benchmark that fixes these evaluation choices while leaving model design open. Across four grids spanning 20-345 kV, it defines 12 protection and event-analysis functions instantiated as 24 scored tasks and supports structured evaluation across observability conditions, predefined distribution shifts, and zero-shot and fine-tuned cross-grid transfer. Committed partitions, leakage controls, and reproducible reporting provide a common basis for comparing future methods. A reference evaluation spanning trivial, conventional, feature-based, and deep-learning baselines shows that wider observability is not uniformly beneficial, shifted conditions can reveal failures not apparent in-distribution, and cross-grid transfer is substantially stronger for fault detection than for fault localization. Protection-relevant diagnostics identify failure modes not apparent from primary metrics alone. EvEMTBench therefore makes generalization in machine-learning-based protection an explicit and reproducible evaluation problem.

0.22

Optimal Measurement Selection for Certifiable Voltage Monitoring in Power Distribution Systems

eess.SY ·2026-09-23 ·Peng Zhang, Line Roald, Manish K. Singh
similarity 0.53
Abstract · 10 pages, 4 figures, submitted to HICSS'60

Maintaining consumer-end voltages within mandated limits is a central task in operating power distribution systems. Rising penetration of distributed generation, electric vehicles, and flexible loads complicates this task, while a scarcity of real-time measurements leaves distribution networks largely unobservable. Operators commonly monitor a few bellwether meters, which indicate operational health but certify nothing about the unmeasured buses. This work asks how to select measurements that are reported in real time and can certify network-wide voltage-limit compliance. We first illustrate the geometry of the measurement values that certify voltage safety at unmeasured nodes. Building on this geometry, we formulate a bilevel optimization that selects measurements to maximize certification capability, introducing a novel safety-violation metric with favorable monotonicity properties. We derive a strong-duality-based single-level reformulation and two scenario-reduction schemes with quantifiable suboptimality. Numerical tests on the SCE 56-bus system corroborate the superior certification capability and computational efficiency of the proposed approach.

0.27

Equivalent Modeling of Load-Side Systems With Distributed Renewable Generation Considering Fault Responses and Nodal Voltage Coherence

eess.SY ·2026-09-21 ·Yuqi Cao, Chen Shen, Shaowei Huang, Ying Chen, Hongyi Zhu
similarity 0.53
Abstract · Submitted to IEEE Transactions on Power Systems

Operating conditions and fault severity change both the initial states and control modes of active distribution networks. Direct capacity aggregation can therefore lose the power responses required for transmission-system dynamic analysis. This paper develops a procedure for generating low-order physical electromagnetic transient equivalents from a small set of representative operating conditions. Device power, ride-through states, load mechanical states, and local sequence voltages are combined with electrical distance to form response families. Response reconstruction and terminal simulation errors determine the retained architecture, after which bounded sensitivity calculations determine effective dynamic coefficients. The architecture and coefficients are then fixed. For a new operating condition, capacity and power balances, voltage-dependent load relations, and an initialization correction generate the model parameters from static inputs and power-flow results. A representative severe fault establishes a template for each fault type, which is reused across fault depths. Aggregation and switching-time bounds explain the roles of voltage coherence and state separation. Comparisons with direct aggregation show improved terminal responses across operating conditions and several fault types, with the largest gains under severe unbalanced faults. The method provides a reusable physical equivalent for operating-condition studies and fault-depth screening.

0.17

AIDC Microgrid Vulnerability Assessment Under Computing-Power Coordinated Attacks

eess.SY ·2026-08-11 ·Ze Yu, Hongwei Zhen, Chao Shen, Mingyang Sun
similarity 0.53
Abstract

The rapid growth of large language model (LLM) services is expanding AI data centers (AIDCs), increasing electricity demand and associated carbon emissions. Renewable energy integration can mitigate these impacts but also strengthens the coupling between AIDC loads and inverter-interfaced generation, creating cross-domain cyber-physical vulnerabilities. Specifically, adversarial AI requests alter AIDC power demand, whereas inverter control tampering modifies source-side dynamics, and their combined impact on system stability varies with generation forecast and demand response uncertainties. To this end, we propose an uncertainty-aware AIDC microgrid vulnerability assessment framework under computing-power coordinated attacks. First, the framework maps adversarial AI requests to AIDC power variations and represents uncertainties in attack-induced demand responses and photovoltaic (PV) forecasts through confidence-weighted realizations. Then, impedance based stability analysis combines these realizations with bounded inverter parameter tampering to construct attack reachable domains and identify critical attack time windows. Furthermore, a separate criterion identifies fixed coordinated attack vectors that retain destabilizing capability throughout each selected window. Case studies demonstrate that, unlike either attack component applied alone, coordinated attacks within identified critical windows induce sustained inverter frequency oscillations with peak absolute deviations exceeding 20% of nominal frequency, whereas the evaluated out-of-window response remains bounded. The proposed method further identifies critical attack windows and the associated coordinated attack vectors.

0.04

Adaptive State Estimation Under Topological Uncertainty in Unobservable Primary Distribution Systems Using Strategically Placed Sensors

eess.SY ·2026-09-23 ·Farah Elsherif, Behrouz Azimian, Anamitra Pal
published similarity 0.52
Abstract · 6 pages, 6 figures, 4 tables. Accepted for presentation at the 2026 North American Power Symposium (NAPS)

The rapid integration of distributed energy resources is fundamentally altering power flow patterns in primary distribution networks and intensifying operational uncertainty. These problems are further compounded by lack of real-time situational awareness and frequent topology changes. To address these problems, this paper proposes an integrated deep learning framework for simultaneous topology identification (TI) and distribution system state estimation (DSSE) in real-time unobservable primary distribution networks instrumented by a minimal set of synchronized measurement devices (SMDs). A correlation-driven SMD placement algorithm is introduced first that jointly satisfies TI accuracy and DSSE performance requirements by exploiting temporal and spatial correlations in nodal voltage measurements. A dual deep neural network (DNN)-based DSSE model is developed next to estimate three-phase voltage magnitudes and angles across diverse operating conditions. To extend the framework beyond the base topology, fine-tuning-based transfer learning is employed to adapt the DSSE model to reconfigured topologies using limited retraining data. The framework is validated under both Gaussian and non-Gaussian measurement noise and benchmarked against a conventional estimation approach and a single DNN model.

0.35

Unifying Power Flow and Electromagnetic Transient Modeling

eess.SY ·2026-09-08 ·Tina Gao, Aayushya Agarwala, Timothy McNamara, Lawrence Pileggi
similarity 0.52
Abstract

Grid tools are separated by timescales: steady-state analysis is performed by power flow (PF), whereas the fastest dynamics are captured by electromagnetic transient (EMT) simulation. Although operating at varying timescales, different tools should produce consistent results when analyzing the same grid conditions. However, the PF steady-state solution does not match the time-to-infinity EMT response. This mismatch exists because simplified device models in PF are inconsistent with the "ground truth" EMT models derived from first principles. As inverter-based resources (IBRs) and data centers strip away inertia and operating reserves, approximations used in PF risk grid security by missing violations. To address this, we introduce a steady-state framework that uses full-physics EMT models for high-fidelity steady-state grid analysis. The challenge lies in systematically formulating algebraic frequency-domain representations of dynamic power devices that are naturally described in state-space form. Our tool, SALT (Steady-state After Last Transients), constructs steady-state representations that exactly capture grid device physics when embedded into transmission networks. The approach exploits the structural properties of power device models and the single-harmonic, balanced nature of the transmission system. Results demonstrate SALT achieves EMT steady-state accuracy while delivering a 1x10^6 times speedup. We demonstrate that SALT can capture security threats in contingency scenarios without exception --- whereas PF-based analyses reported 75% fewer rated line violations, 18% fewer Q-limit violations, and 7% fewer voltage violations.

0.20