Adaptive State Estimation Under Topological Uncertainty in Unobservable Primary Distribution Systems Using Strategically Placed Sensors

Farah Elsherif, Behrouz Azimian, Anamitra Pal

eess.SY ·submitted 2026-09-23 22:34 UTC · v1
published

Abstract

The rapid integration of distributed energy resources is fundamentally altering power flow patterns in primary distribution networks and intensifying operational uncertainty. These problems are further compounded by lack of real-time situational awareness and frequent topology changes. To address these problems, this paper proposes an integrated deep learning framework for simultaneous topology identification (TI) and distribution system state estimation (DSSE) in real-time unobservable primary distribution networks instrumented by a minimal set of synchronized measurement devices (SMDs). A correlation-driven SMD placement algorithm is introduced first that jointly satisfies TI accuracy and DSSE performance requirements by exploiting temporal and spatial correlations in nodal voltage measurements. A dual deep neural network (DNN)-based DSSE model is developed next to estimate three-phase voltage magnitudes and angles across diverse operating conditions. To extend the framework beyond the base topology, fine-tuning-based transfer learning is employed to adapt the DSSE model to reconfigured topologies using limited retraining data. The framework is validated under both Gaussian and non-Gaussian measurement noise and benchmarked against a conventional estimation approach and a single DNN model.

Comment
6 pages, 6 figures, 4 tables. Accepted for presentation at the 2026 North American Power Symposium (NAPS)

Closest papers

Nearest neighbours by meaning across the whole index.

Bayesian Distribution System State Estimation with Flow Matching

cs.LG cs.AIeess.SP ·2026-10-29 ·Nan Lin, Peter Palensky, Pedro Vergara Barrios
similarity 0.74
Abstract · 10 pages

Medium-voltage feeders have few real-time measurements, so distribution system state estimation (DSSE) rests on pseudo-measurements of the secondary substations, a prior in Bayesian terms. Weighted least squares keeps the power flow exact but reduces this prior to a mean and variance, while supervised deep learning estimators also learn the power flow and are tied to one measurement set. We propose PoSE (posterior sampling for state estimation), which keeps the Bayesian structure of DSSE and learns only what the distribution system operator does not know, namely the distribution of substation injections, modelled by a neural network trained with flow matching on historical data. The power flow equations, grid topology and measurements enter only at sampling, through a noise-aware Kalman-type correction. The neural network therefore never approximates the power flow, but every posterior sample is a physically consistent operating point, and one trained prior serves any measurement set, noise level and topology. On the IEEE 33-bus feeder, PoSE lowers the probabilistic injection error (CRPS) by 6.7-7.5% against a full-covariance Gaussian prior in all 12 tested settings. It provides reliable uncertainty: the 90% intervals contain the true injection almost exactly as often as exact posterior samples would, whereas those of supervised estimators contain it in only 37-78% of cases. On the 240-bus unbalanced three-phase Iowa feeder, it gives the lowest injection, voltage and branch-current errors of all estimators. A fast variant matches this accuracy at 0.2-0.6s per snapshot and, without retraining, beats Gaussian priors and retrained supervised estimators on seven reconfigured topologies.

0.17

Machine Learning-Based State Estimation for an Actual Transmission System Using Field PMU Data

eess.SY ·2026-09-22 ·Shiva Moshtagh, Nihar Thakkar, Anamitra Pal, Evangelos Farantatos
published similarity 0.69
Abstract · Accepted for presentation at the 60th Hawaii International Conference on System Sciences (HICSS-60), 2027

Time-synchronized state estimation (SE) plays a critical role in ensuring real-time situational awareness in modern power systems. However, achieving full system observability using phasor measurement units (PMUs) is often impractical due to cost and deployment constraints. Moreover, SE operation at PMU timescales imposes stringent requirements on latency, robustness, and reliability that are difficult to satisfy using conventional iterative hybrid SE techniques under incomplete observability by PMUs. This paper evaluates the feasibility of deploying deep neural networks for PMU-timescale, time-synchronized SE in real-world PMU-unobservable transmission systems using actual data from a US power utility. Key contributions include a systematic assessment of estimation accuracy, scalability, and computational performance under realistic operating conditions.

0.34

Learning-Based Power Flow Estimation with Sparse PMU Deployment in Power Systems

eess.SY ·2026-10-09 ·Van-Hai Bui, Quang Manh Hoang, Akhtar Hussain, Wencong Su
similarity 0.69
Abstract · 14

Accurate monitoring of power flow is fundamental to the secure and reliable operation of modern power systems. Existing data-driven power flow estimation methods typically assume that synchronized measurements are available at every bus, requiring extensive deployment of phasor measurement units (PMUs). Such dense sensing infrastructures substantially increase installation, communication, and maintenance costs. This paper proposes a learning-based framework that minimizes the number of installed PMUs while maintaining high-accuracy systemwide power flow estimation. Instead of relying on measurements from all buses, the proposed method identifies an informative subset of buses whose synchronized measurements are sufficient to accurately reconstruct branch power flow across the network. To this end, a neural network is developed to learn the nonlinear relationship between PMU measurements and system-wide power flows, and multiple PMU deployment scenarios are evaluated to quantify the trade-off between measurement availability and estimation accuracy. The results enable utilities to identify cost-effective PMU placement strategies that balance deployment cost and prediction performance. Case studies on the IEEE 30-bus test system demonstrate that the proposed framework significantly reduces the number of required PMUs while maintaining accurate power flow estimation.

0.18

Beyond Accuracy: Physics-Informed Evaluation of ANN-based Power Flow Solvers under System Shift

eess.SY ·2026-11-10 ·Dong Liu, Jochen Stiasny, Jochen Cremer, Pedro P. Vergara
similarity 0.68
Abstract

Recent advances in artificial deep learning-based power flow (PF) solvers have primarily focused on improving estimation accuracy, while their physical feasibility and operational reliability under realistic system variations remain insufficiently evaluated. This paper proposes a physics-informed evaluation framework for deep learning-based PF solvers under topology and load distribution shifts. Beyond conventional voltage-domain errors, the framework incorporates KCL gaps, branch-flow gaps, KVL residuals, continuous feasibility scores, and strict, practical, and relaxed PF feasibility rates. Four case studies are designed to investigate topology shifts, mixed topology training, load distribution shifts, and combined topology distribution shifts. Eight ANN architectures, including graph input models, load-only baselines, and physics-informed neural networks, are evaluated under consistent settings. The results demonstrate that low estimation errors do not necessarily correspond to physically feasible or operationally reliable PF solutions, particularly under combined system shifts. The proposed framework establishes an initial foundation and analysis for the development and verification of trustworthy deep learning-based PF solvers, providing support for their reliable deployment in future AI-enabled power system analysis.

0.09

Real-Time Edge-based Detection of Correlated AI Data-Center Load Episodes

eess.SY ·2026-08-24 ·Chandan Chaudhary, Abanish Tiwari, Yansong Pei, Mohammed Ben-Idris, Joydeep Mitra
similarity 0.65
Abstract · Submitted to 2027 IEEE PES Grid Edge, to be held in 19-22 April, Salt Lake City, Utah, USA

Artificial-intelligence data centers running bulk-synchronous training can impose sub-second power swings. When several facilities synchronize their training cycles, these load variations become spatially correlated and amplify the aggregate disturbance on the grid. A grid operator without access to data-center telemetry must infer this correlation from electrical measurements alone. However, the required observation time and the feasibility of detection on substation-deployable hardware remain uncharacterized. This paper develops a correlation-based detection method to classify the multi-facility operating regime from cross-facility power measurements. Analytical derivations and experimental validation show that the resulting detection confidence increases with the observation-window length at a rate governed by the load correlation time. The method is demonstrated in a real-time hardware-in-the-loop testbed, where load setpoints generated from a validated semi-Markov data-center load model are applied to an electromagnetic-transient grid simulation on a Real-Time Digital Simulator. A compact classifier built on pairwise power correlations runs on an edge device in this loop and determines whether the data-center load variations are independent or spatially correlated. The cross-facility correlation separates the independent and correlated cases across independent realizations. The held-out detection accuracy improves with the observation window, consistent with the predicted relation. A raw-waveform network fails to generalize, supporting pairwise correlation as the discriminative signal. The detector executes in real time on commodity edge hardware. A closed-loop demonstration against the running simulator tracks a regime change within one observation window.

0.43

Topology-adaptive Estimation of Maximum Voltage Unbalance for Distribution Networks with Finite-sample Guarantee

eess.SY ·2026-10-14 ·Jinbao Wang, Jun Liu, Shiliang Zhang, Xuehui Ma, He Zhang
similarity 0.63
Abstract

High penetration of single-phase distributed power production and frequent topology changes can significantly increase voltage unbalance in distribution networks. Reliable probabilistic power flow (PPF) assessment for the network, therefore, must account for topology-dependent power-flow equations, numerical error in the voltage unbalance factor (VUF), and finite-sample uncertainty in power measurements. In this paper, we propose Topology-Adaptive Certified Quantile Estimation (TACQE) to estimate the maximum VUF across monitored electric buses. Following a local network change, TACQE updates the cross-couplings among power-flow sequences, and certifies candidate PPF solutions against the updated nonlinear equations. The resulted power-flow state enclosures provide rigorous bounds on the maximum VUF. Furthermore, we derive independent reference-solver evaluations to calibrate discrepancies from the reference PPF solution. This leads to a uniform sampling bound that yields simultaneous upper-tail probabilities and quantiles, which provides a finite-sample guarantee for the estimated maximum-VUF distribution over an entire range of VUF thresholds. From our numerical simulations across 101 fixed-topology quantiles, it demonstrates that the designed TACQE can provide a fast candidate post-change power flow solution where it reuses most of the previous network model and modifies only the affected bus blocks.

0.17

Hierarchical Graph Neural Network for Probabilistic Power Flow with Grid Topology Contingencies

eess.SY cs.GR ·2026-10-09 ·Jinbao Wang, Jun Liu, Shiliang Zhang, Xuehui Ma, Lin Yan +2 more
published similarity 0.63
Abstract

Data-driven surrogates reduce the nonlinear solves required for probabilistic power flow (PPF), but models tied to a fixed bus--branch graph often generalize poorly when outages change electrical coupling. This paper proposes a topology-decomposition-driven hierarchical bidirectional graph neural network (TDD--HBGNN) for PPF under unseen topologies. For each realized topology, the network is decomposed into fundamental topological units (FTUs), dynamically homogeneous voltage clusters (DHVCs), and a core backbone sub-grid (CBSG), with equivalent-admittance representations preserving electrical ports between units. A sensitivity-based linear prior captures the first-order voltage-magnitude and phase-angle response, while the HBGNN learns topology-dependent nonlinear residuals. Impedance- and uncertainty-aware bottom-up aggregation condenses local perturbations, while mode-modulated top-down broadcasting restores system context at buses. We evaluate our approach on the IEEE 118-bus and Polish 2746-bus systems under unseen N--1 and N--2 contingencies against six baseline methods. Compared with these methods, TDD--HBGNN achieves 2.47--4.20-fold lower all-bus phase-angle errors and lower phase-angle errors in every held-out event. Its voltage-magnitude advantage is concentrated near the outaged branches, where paired error ratios reach 1.75--2.58 on the IEEE system and 1.87--1.97 in Polish N--2 events. All system--contingency--baseline comparisons favor TDD--HBGNN in joint voltage--angle error. Moreover, shared hierarchical operators keep the model size at 0.658 million parameters across both grids and yield 0.161--1.793~ms forward latency per probabilistic case. These results demonstrate system-wide angular accuracy, outage-local voltage accuracy, and parameter-efficient scaling across unseen topologies.

0.56

PowerModels-ACOPF-AI: On-the-Fly Machine Learning Approach for Solving AC Optimal Power Flow Integrating Renewable Energy Sources

eess.SY ·2026-09-16 ·Bhuban Dhamala, Jose Tabarez, Anup Pandey
benchmark similarity 0.62
Abstract

The increasing complexity of modern power systems, driven by high renewable penetration, load variability, and operational uncertainty, demands fast and reliable solutions to the AC optimal power flow problem (AC-OPF). Traditional optimization methods, though accurate, often struggle with scalability and high computational burdens, making them impractical for real-time use in large networks. This paper introduces PowerModels-ACOPF-AI, a two-stage Bayesian Neural Network (BNN) surrogate designed to predict generator set points, bus voltages, and phase angles with uncertainty. The framework integrates a performance-sensitive on-the-fly learning mechanism that identifies regions of degraded prediction accuracy and dynamically retrains with additional AC-OPF solutions generated by PowerModels.jl. This self-adaptive loop ensures robust performance, enabling the model to maintain accuracy under novel or highly variable operating conditions. Validation on benchmark test systems of different sizes, namely the 30-bus, 200-bus, and 500-bus networks, demonstrates strong generalization capability, efficient handling of stochastic renewable injections, and the ability to provide rapid, uncertainty-aware predictions. Beyond predictive accuracy, the proposed approach offers practical value as both a real-time advisory tool for system operators and a fast initializer for conventional solvers, thus supporting resilient and efficient grid operation in future power systems.

0.16