CS Paper Radar

Topology-adaptive Estimation of Maximum Voltage Unbalance for Distribution Networks with Finite-sample Guarantee

Jinbao Wang, Jun Liu, Shiliang Zhang, Xuehui Ma, He Zhang

eess.SY ·submitted 2026-10-14 11:43 UTC · v1

Abstract

High penetration of single-phase distributed power production and frequent topology changes can significantly increase voltage unbalance in distribution networks. Reliable probabilistic power flow (PPF) assessment for the network, therefore, must account for topology-dependent power-flow equations, numerical error in the voltage unbalance factor (VUF), and finite-sample uncertainty in power measurements. In this paper, we propose Topology-Adaptive Certified Quantile Estimation (TACQE) to estimate the maximum VUF across monitored electric buses. Following a local network change, TACQE updates the cross-couplings among power-flow sequences, and certifies candidate PPF solutions against the updated nonlinear equations. The resulted power-flow state enclosures provide rigorous bounds on the maximum VUF. Furthermore, we derive independent reference-solver evaluations to calibrate discrepancies from the reference PPF solution. This leads to a uniform sampling bound that yields simultaneous upper-tail probabilities and quantiles, which provides a finite-sample guarantee for the estimated maximum-VUF distribution over an entire range of VUF thresholds. From our numerical simulations across 101 fixed-topology quantiles, it demonstrates that the designed TACQE can provide a fast candidate post-change power flow solution where it reuses most of the previous network model and modifies only the affected bus blocks.

Closest papers

Nearest neighbours by meaning across the whole index.

Efficient Quantile-Resolved Hosting Capacity Assessment on Nodal Level for Low-Voltage Grids

eess.SY ·2026-09-08 ·Maximilian Köhler, Edwin Mora, Mathias Duckheim, Stefan Niessen
similarity 0.71
Abstract · Submitted to IEEE PES ISGT Europe 2026. 5 pages, 3 figures. Keywords: Hosting Capacity, Uncertainty, Distribution Grid, Distributed Energy R…

Hosting capacity - the maximum additional capacity a network can accommodate without violating operational limits - is a key metric in distribution system planning and operation. Decisions on grid reinforcements and the deployment of flexibility management require not only the worst-case HC but also an understanding of the distribution of HC under different likelihoods in load and generation patterns. Quantile-resolved HC distributions provide this view by expressing HC as a function of an acceptable operational limit exceedance likelihood. Monte Carlo sampling is the established approach for computing such distributions but demands large computational resources. Approximations sacrifice either accuracy, the ability to capture uncertainty correlations, or scalability when assessing real-world networks. This paper introduces a computationally efficient method for calculating distributions for quantile-resolved HC. It uses a representation of load samples as multivariate normal distribution, propagated through a linearized power flow model. This allows for leveraging a re-parametrized AC-OPF problem for each hosting capacity quantile. Benchmarking against Monte Carlo-based methods on realistic LV networks demonstrates that the proposed method achieves comparable accuracy with a mean deviation of approx. 3%, while reducing computational time by orders of magnitude. For the exemplary networks the computational time decreases from 11 min to 2 s, and 38 h to 50 s, respectively. The method's scalability is also suitable for recalculation in 15-minute cycles encountered in DSO practice for e.g., real-time grid management.

0.21

Adaptive State Estimation Under Topological Uncertainty in Unobservable Primary Distribution Systems Using Strategically Placed Sensors

eess.SY ·2026-09-23 ·Farah Elsherif, Behrouz Azimian, Anamitra Pal
published similarity 0.63
Abstract · 6 pages, 6 figures, 4 tables. Accepted for presentation at the 2026 North American Power Symposium (NAPS)

The rapid integration of distributed energy resources is fundamentally altering power flow patterns in primary distribution networks and intensifying operational uncertainty. These problems are further compounded by lack of real-time situational awareness and frequent topology changes. To address these problems, this paper proposes an integrated deep learning framework for simultaneous topology identification (TI) and distribution system state estimation (DSSE) in real-time unobservable primary distribution networks instrumented by a minimal set of synchronized measurement devices (SMDs). A correlation-driven SMD placement algorithm is introduced first that jointly satisfies TI accuracy and DSSE performance requirements by exploiting temporal and spatial correlations in nodal voltage measurements. A dual deep neural network (DNN)-based DSSE model is developed next to estimate three-phase voltage magnitudes and angles across diverse operating conditions. To extend the framework beyond the base topology, fine-tuning-based transfer learning is employed to adapt the DSSE model to reconfigured topologies using limited retraining data. The framework is validated under both Gaussian and non-Gaussian measurement noise and benchmarked against a conventional estimation approach and a single DNN model.

0.35

A Bayesian Adaptive Spectral Surrogate Model for Efficient Probabilistic Optimal Power Flow Evaluation

eess.SY ·2026-09-01 ·Xiaoting Wang, Xiaozhe Wang, Gregory Kish, Yunwei, Li
top venue similarity 0.63
Abstract · 18 pages, 15 figures. To appear in IEEE Transactions on Power Systems

This paper presents an adaptive stochastic spectral embedding (ASSE) method to solve the probabilistic AC optimal power flow (AC-OPF), a critical aspect of power system operation. The proposed method can efficiently and accurately estimate the probabilistic characteristics (e.g., mean, variance, median, and quantile-based metrics) of AC-OPF solutions while minimizing power losses. Based on estimated AC-OPF decisions (i.e., generator outputs), the confidence interval (CI)-based production cost index can be determined. Specially, an adaptive domain partition strategy is adopted to guide refinement domain selection and partition. The Bayesian compressive sensing-based coefficient calculation algorithm is integrated to enhance its performance. Numerical studies on modified IEEE 9-bus and IEEE 118-bus systems demonstrate that the proposed ASSE method offers accurate and fast evaluations compared to Monte Carlo simulations. Comparisons with a sparse polynomial chaos expansion, Gaussian process regression, and deep neural networks, further illustrate its efficacy in accurately assessing the responses with strongly localized behavior and non-symmetric distributions, providing practical decision-making bounds for generator outputs and operating costs under uncertainty.

0.42

EPIGRIDS: Documentation and Validation of Seven Open Synthetic Transmission Grid Cases

eess.SY math.OC ·2026-11-13 ·Jonathan M. Snodgrass, Scott Greene, Thomas J. Overbye, Christopher L. DeMarco, Bernard C. Lesieutre
benchmark similarity 0.62
Abstract · 10 pages, 2 figures, 6 tables. Submitted to the IEEE Open Access Journal of Power and Energy. Cases: https://doi.org/10.5281/zenodo.23814538…

This paper documents and checks EPIGRIDS, seven open synthetic transmission grid cases from four independently built networks, made with an optimization-based construction method instead of the graph-statistics method behind most large public synthetic grids. The cases range from 250 to 78,484 buses, with geolocated substations, voltages up to 765 kV, and line parameters taken from conductor data. Each ships under an open license in three common power flow formats that agree at the solved operating point, and the six larger cases have a companion hourly, bus-level load series for one year. The Texas, Florida, and Michigan, Ohio, and Indiana cases are sub-networks of the Eastern case. Every case solves an alternating-current power flow from its stored operating point. With parallel circuits merged, the Eastern and Western cases are 9 and 16% denser than the real interconnections, while graph-statistics cases on the same footprints lie within 6% and meet more published realism criteria. A full single-outage contingency analysis completes on every case, and in an optimal power flow benchmark every case except the New England base case and one of its 12 operating points solves in polar form.

0.39

A Multi-Stage Linear Programming Framework for Three-Phase State Estimation in Low-Voltage Distribution Grids

eess.SY ·2026-09-24 ·Mohsen Banaei, Eghbal Hosseini, Ahlam Jameel, Konstantin Filonenko, Shahrzad Pour +1 more
published similarity 0.61
Abstract · Presented at the International Energy Future Conference, 2025, Rome

Low-voltage (LV) distribution feeders are increasingly difficult to monitor because real-time load data are unavailable, historical measurements are sparsely sampled, and high-rate voltage sensors cover only a few nodes. This paper proposes a multi-stage linear programming (MSLP) estimator for three-phase unbalanced LV grids that reconstructs per-phase nodal voltages under such limited observability. The estimator linearises the three-phase power flow through voltage-to-power sensitivity matrices and adjusts the nodal active and reactive power injections so that the resulting voltages match the available measurements. To limit the error introduced by linearisation, the sensitivities are rebuilt and the power corrections refined over successive iterations, and power-balance constraints at intermediate metered nodes are added to tighten the feasible region. The method is validated on a real 50-node Danish LV feeder, where it attains a mean absolute error of 0.641V, a standard deviation of 0.816V, a root-mean-square error of 0.842~V, and a maximum error of 3.437V. Compared with a single-stage linear estimator, MSLP lowers the error metrics by roughly 16 percent on average, and additional studies quantify the influence of the input-preparation strategy and of the number of estimation meters.

0.32

Optimal Measurement Selection for Certifiable Voltage Monitoring in Power Distribution Systems

eess.SY ·2026-09-23 ·Peng Zhang, Line Roald, Manish K. Singh
similarity 0.61
Abstract · 10 pages, 4 figures, submitted to HICSS'60

Maintaining consumer-end voltages within mandated limits is a central task in operating power distribution systems. Rising penetration of distributed generation, electric vehicles, and flexible loads complicates this task, while a scarcity of real-time measurements leaves distribution networks largely unobservable. Operators commonly monitor a few bellwether meters, which indicate operational health but certify nothing about the unmeasured buses. This work asks how to select measurements that are reported in real time and can certify network-wide voltage-limit compliance. We first illustrate the geometry of the measurement values that certify voltage safety at unmeasured nodes. Building on this geometry, we formulate a bilevel optimization that selects measurements to maximize certification capability, introducing a novel safety-violation metric with favorable monotonicity properties. We derive a strong-duality-based single-level reformulation and two scenario-reduction schemes with quantifiable suboptimality. Numerical tests on the SCE 56-bus system corroborate the superior certification capability and computational efficiency of the proposed approach.

0.27

Bayesian Distribution System State Estimation with Flow Matching

cs.LG cs.AIeess.SP ·2026-10-29 ·Nan Lin, Peter Palensky, Pedro Vergara Barrios
similarity 0.60
Abstract · 10 pages

Medium-voltage feeders have few real-time measurements, so distribution system state estimation (DSSE) rests on pseudo-measurements of the secondary substations, a prior in Bayesian terms. Weighted least squares keeps the power flow exact but reduces this prior to a mean and variance, while supervised deep learning estimators also learn the power flow and are tied to one measurement set. We propose PoSE (posterior sampling for state estimation), which keeps the Bayesian structure of DSSE and learns only what the distribution system operator does not know, namely the distribution of substation injections, modelled by a neural network trained with flow matching on historical data. The power flow equations, grid topology and measurements enter only at sampling, through a noise-aware Kalman-type correction. The neural network therefore never approximates the power flow, but every posterior sample is a physically consistent operating point, and one trained prior serves any measurement set, noise level and topology. On the IEEE 33-bus feeder, PoSE lowers the probabilistic injection error (CRPS) by 6.7-7.5% against a full-covariance Gaussian prior in all 12 tested settings. It provides reliable uncertainty: the 90% intervals contain the true injection almost exactly as often as exact posterior samples would, whereas those of supervised estimators contain it in only 37-78% of cases. On the 240-bus unbalanced three-phase Iowa feeder, it gives the lowest injection, voltage and branch-current errors of all estimators. A fast variant matches this accuracy at 0.2-0.6s per snapshot and, without retraining, beats Gaussian priors and retrained supervised estimators on seven reconfigured topologies.

0.17

Reinsertion-Aware Parameter Estimation of the WECC Composite Load Model via Closed-Loop Equivalent-Network Co-Estimation

eess.SY ·2026-10-25 ·Jong Ha Woo, Victor Daldegan Paduani, Zishuo Yang, Yu Ma, Qi Xiao +1 more
benchmark similarity 0.60
Abstract · 10 pages, 10 figures, 7 tables. Submitted to IEEE Transactions on Power Systems

Measurement-based parameter estimation of the WECC composite load model (CMLD) commonly relies on voltage replay, where measured voltage is imposed on an isolated CMLD and its parameters are optimized to reproduce measured active and reactive power. However, this open-loop formulation neglects the two-way dynamic interaction between the load and grid, potentially causing large errors when the estimated model is reinserted into dynamic grid simulations. To address this limitation, we propose a closed-loop parameter estimation framework that alternately estimates the CMLD parameters and a five-parameter equivalent network representing the external grid. This framework restores load-grid interaction during estimation and enables voltage, active power, and reactive power to jointly constrain the parameter estimation. Compared with four baseline methods, the proposed approach achieves the highest reinsertion accuracy in both the CMLD benchmark and transmission and distribution (T&D) co-simulation environments. In the T&D case, it reduces active-power, reactive-power, and voltage errors by 73%, 64%, and 62%, respectively. The identified model also maintains improved reinsertion accuracy under disturbances not used for estimation, demonstrating transferability beyond the identification event.

0.26