CS Paper Radar

Optimal Measurement Selection for Certifiable Voltage Monitoring in Power Distribution Systems

Peng Zhang, Line Roald, Manish K. Singh

eess.SY ·submitted 2026-09-23 21:03 UTC · v1

Abstract

Maintaining consumer-end voltages within mandated limits is a central task in operating power distribution systems. Rising penetration of distributed generation, electric vehicles, and flexible loads complicates this task, while a scarcity of real-time measurements leaves distribution networks largely unobservable. Operators commonly monitor a few bellwether meters, which indicate operational health but certify nothing about the unmeasured buses. This work asks how to select measurements that are reported in real time and can certify network-wide voltage-limit compliance. We first illustrate the geometry of the measurement values that certify voltage safety at unmeasured nodes. Building on this geometry, we formulate a bilevel optimization that selects measurements to maximize certification capability, introducing a novel safety-violation metric with favorable monotonicity properties. We derive a strong-duality-based single-level reformulation and two scenario-reduction schemes with quantifiable suboptimality. Numerical tests on the SCE 56-bus system corroborate the superior certification capability and computational efficiency of the proposed approach.

Comment
10 pages, 4 figures, submitted to HICSS'60

Closest papers

Nearest neighbours by meaning across the whole index.

Topology-adaptive Estimation of Maximum Voltage Unbalance for Distribution Networks with Finite-sample Guarantee

eess.SY ·2026-10-14 ·Jinbao Wang, Jun Liu, Shiliang Zhang, Xuehui Ma, He Zhang
similarity 0.61
Abstract

High penetration of single-phase distributed power production and frequent topology changes can significantly increase voltage unbalance in distribution networks. Reliable probabilistic power flow (PPF) assessment for the network, therefore, must account for topology-dependent power-flow equations, numerical error in the voltage unbalance factor (VUF), and finite-sample uncertainty in power measurements. In this paper, we propose Topology-Adaptive Certified Quantile Estimation (TACQE) to estimate the maximum VUF across monitored electric buses. Following a local network change, TACQE updates the cross-couplings among power-flow sequences, and certifies candidate PPF solutions against the updated nonlinear equations. The resulted power-flow state enclosures provide rigorous bounds on the maximum VUF. Furthermore, we derive independent reference-solver evaluations to calibrate discrepancies from the reference PPF solution. This leads to a uniform sampling bound that yields simultaneous upper-tail probabilities and quantiles, which provides a finite-sample guarantee for the estimated maximum-VUF distribution over an entire range of VUF thresholds. From our numerical simulations across 101 fixed-topology quantiles, it demonstrates that the designed TACQE can provide a fast candidate post-change power flow solution where it reuses most of the previous network model and modifies only the affected bus blocks.

0.17

Robustness of Local Energy Markets to Cyberattacks: Case Study of False Data Injection

cs.CR ·2026-09-29 ·Mehran Moradi, Reza Zamani, Phil Aupke, Andreas Theocharis, Andreas Kassler
similarity 0.58
Abstract

Market clearing in community-based local energy markets relies on power demand and PV forecasts, making it vulnerable to coordinated false data injection (FDI) attacks. This paper proposes a bilevel optimization framework to identify worst-case bus-level FDI against interconnected multi-community electricity markets within a distribution network. The upper level attacker maximizes physical impact, measured by cumulative voltage deviation, while accounting for detectability. The lower level re-clears the interconnected multi-community markets subject to operational and network constraints. The bilevel model is reformulated as a single-level mixed-integer program through Karush-Kuhn-Tucker conditions and solved using the epsilon constraint method to characterize the trade-off between physical impact and detectability. Case studies on the IEEE 33-bus system with three communities show that even bounded, system-level zero-sum attacks can reshape local trading, reduce voltage security margins, and produce asymmetric community-level market outcomes. The results further show that vulnerability depends strongly on the spatiotemporal placement of falsified data rather than on uniform spreading across buses and time periods.

0.26

Safety Screening for Voltage Control in Active Distribution Grids via Distributionally Robust Conformal Screening

eess.SY cs.AIcs.LG ·2026-08-31 ·Sarra Bouchkati, Petros Ellinas, Adriana Geisler, Steffen Kortmann, Johanna Vorwerk +2 more
similarity 0.57
Abstract · Sarra Bouchkati, Petros Ellinas, and Adriana Geisler contributed equally to this work

Deploying a new control policy for voltage control in active distribution grids requires evidence that physical limits will be satisfied before the policy is tested on the physical grid. This assessment is difficult for two reasons. First, simulations cannot capture every disturbance, modeling error, and device interaction present in the real grid. Second, historical measurements reflect operation under existing control policies, whereas a new policy may drive the grid into different operating conditions. To address these challenges, we propose Distributionally Robust Conformal Safety Screening (DR-CSS), a policy-agnostic framework for pre-deployment, scenario-by-scenario screening of a new control policy using historical data and a nominal simulator. For each new scenario, the simulator predicts a future voltage trajectory for the whole grid; DR-CSS then constructs a conformal safety interval around this prediction using historical simulation-to-reality errors. The interval is further enlarged to account for closed-loop changes induced by the deployment of the new policy and its interactions with the remaining controllers. To the best of our knowledge, DR-CSS is the first framework in power systems to combine historical data from an existing control policy with an imperfect simulator for pre-deployment safety screening of a new policy. Experiments on the IEEE 33-bus and IEEE 141-bus systems evaluate the deployment of learning-based voltage control policies and show that DR-CSS identifies all unsafe test scenarios. To reduce unnecessary warnings on safe scenarios, we adapt the safety intervals to different operating conditions and gradually introduce new policies with recalibration after each stage. These extensions increase the informational value of the safety screening and support safer deployment decisions in active distribution grids.

0.21

Reducing Data-Center Load Transfers with Ride-Through-Aware Voltage Control

eess.SY ·2026-11-05 ·Siyu Lu, Yang Weng
similarity 0.57
Abstract · 10 pages, 5 figures

Fault-induced transfers of large data centers to backup supply can cause abrupt reductions in grid-served demand. Coordinating reactive-power support to mitigate these transfers requires consideration of facility-specific voltage--duration ride-through characteristics, particularly when support capacity is limited. This paper develops a ride-through-aware extension of quadratic voltage control that assesses voltage deviations relative to the admissible margins specified by these characteristics. We establish four design requirements that jointly express envelope-based severity, duration dependence, and preventive voltage-restoration incentives. Within a multiplicatively gated quadratic class, we derive necessary and sufficient conditions for satisfying these requirements and construct an explicit family of envelope-normalized objectives. We apply the proposed objectives to reactive-power coordination and evaluate their performance on the IEEE 14-bus, New England 39-bus, and NPCC 140-bus systems. Comparisons with Volt/VAR control, conventional nominal-voltage tracking, and recent data-center voltage-control methods demonstrate improved data-center retention under matched reactive-power support constraints. In the IEEE 14-bus study, the proposed controller reduces the mean data-center disconnection rate by 44.8\% and grid-demand loss by 27.4\% compared with the best-performing baseline. These results highlight the benefit of incorporating data-center ride-through requirements into reactive-power allocation.

0.50

AC-Aware Steady-State Security Region Characterization via Exclusion Refinement

eess.SY ·2026-10-12 ·Zhirou Wang, Zhengshuo Li, Shuo Yang
similarity 0.57
Abstract

As active power dispatch becomes increasingly coupled with reactive power support and voltage security in modern power systems, AC security regions (AC-SRs) under exact steady-state AC power flow (AC-PF) constraints provide valuable insights into admissible operating boundaries and security margins for security assessment. However, the nonconvexity of exact AC-PF constraints makes it difficult to achieve both accuracy and computational efficiency in AC-SR characterization. To this end, this paper proposes an AC-aware iterative exclusion refinement (AC-ITER) approach that refines a given convex-relaxed AC-SR toward the exact AC-SR by progressively constructing and removing convexlocal exclusion subregions around numerically identified insecure points. Boundary-point searches and dual-based local exclusion cuts provide a tractable approximation of relaxation-induced insecure portions. A statistical certification method based on uniform sampling is developed to support high-confidence assessment of residual-region security and guide termination, while an AC-PF security similarity-based acceleration (AC-SSA) approach is introduced to further accelerate the sampling-based search for insecure operating points. Numerical studies on academic test systems and real-world systems demonstrate the characterization accuracy of AC-ITER and the computational efficiency gained through AC-SSA.

0.27

Critical Weather Scenario Screening Using Weather-to-Voltage (W2V) Predictive Modeling

eess.SY ·2026-08-24 ·Sol Lim, Min-Seung Ko, Hao Zhu
published similarity 0.57
Abstract · 6 pages, 2 figures. Accepted to IEEE SmartGridComm 2026

This paper proposes a critical weather scenario screening framework for identifying weather conditions that can trigger high-voltage (HV) events in the power grid. Unlike conventional weather-aware contingency analysis limited to component-level outage risk, our framework screens weather scenarios as potential drivers of grid-level voltage violations. Given a non-critical weather scenario, we seek the perturbation over the high-dimensional weather space to maximize a pre-defined voltage criticality score, by using a differentiable weather-to-voltage (W2V) predictive model to facilitate the gradient update over a compact latent space. Specifically, a non-negativity constraint is used for achieving physically-consistent perturbations, with another L1-norm based constraint for bounded perturbation. The latter could promote sparse and interpretable perturbations, and this uniform budget also yields a sensitivity-aware vulnerability ranking across different weather scenarios. Numerical experiments on a 6717-bus synthetic Texas system have effectively demonstrated the potential of weather uncertainty in triggering HV events, and this potential cannot be represented by the voltage analysis of individual weather scenarios. Interestingly, the most vulnerable scenarios are characterized by wind-dominated perturbation patterns concentrated in high wind-capacity regions, coinciding with observations from actual power flow data and experiences in real system operations.

0.40

Agreement Is Not Assurance: Evidence-Independent Safety Gates for Agentic AI in DER-Rich Distribution Grids

eess.SY ·2026-11-11 ·Qianxue Xia
similarity 0.56
Abstract · 10 pages, 3 figures, 4 tables

Physics-based safety gates for large language model (LLM) agents can approve unsafe actions when the agent and gate rely on the same corrupted measurements or network records. We formulate this shared-evidence failure for voltage-constrained distributed energy resource (DER) export decisions and analyze how nearly critical DER telemetry can bias state estimation while evading residual-based bad-data detection. We propose evidence-independent verification (EIV), which combines advanced metering infrastructure (AMI) voltage readings, measurement selection based on predicted voltage rise, and bounded physical probes. An IEEE 123-bus hidden-truth testbed evaluates 1,654 near-limit requests under telemetry attacks and record errors. For telemetry attacks targeting the nominal gate, an AC-twin gate with bad-data detection approved 95% of unsafe requests, compared with 3.1% for EIV; EIV rejected 22% of safe clean requests. At matched false-rejection settings, direct AMI checks outperformed incorporating the same readings into state estimation. Gate-targeted attacks exposed a vulnerability in telemetry-based response prediction. Command-based prediction removed that route, but targeted attacks on fresh validation cases still produced a 20% unsafe-approval rate under the tested attack pool. LLM agents frequently sought independent evidence voluntarily, but injected instructions and phase-label errors caused unsafe decisions. When offered the EIV checker as a tool, they used it in 93-100% of episodes; mandatory use did not reduce observed violations, which primarily reflected checker errors. These results distinguish enforcement of verification from reliability of the verifier itself.

0.27

Calibrating Ambiguity Set via Diagnostic Transport for Distributionally Robust Optimization

cs.LG stat.MLmath.OC ·2026-10-07 ·Wenbin Zhou, Elizabeth Cucuzzella, Shixiang Zhu
similarity 0.56
Abstract

Distributionally robust optimization (DRO) protects decisions against distributional uncertainty by optimizing over an ambiguity set, but poorly aligned set geometry can require large radii and yield overly conservative decisions. We introduce diagnostic-transport DRO (DT-DRO), which uses held-out calibration data to adapt the ambiguity-set geometry to observed predictive errors. DT-DRO uses the conditional probability integral transform cumulative distribution function to diagnose systematic probability misallocation and translates this information into an outcome-level transport that jointly adjusts the ambiguity-set center and ground cost. The resulting formulation admits a computationally tractable dual reformulation. Theoretically, we derive valid ambiguity radii and decision-risk guarantees that tighten as estimation and approximation errors vanish, and show that DT-DRO can eliminate the nonvanishing robustness floor caused by model misspecification. Synthetic experiments and a power-outage application demonstrate improved decision quality, particularly under structural and tail misspecification.

0.22